Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effective Kitchen Ventilation for Healthy Zero Net Energy Homes with Natural Gas

Past studies indicate that kitchen ventilation that minimally complies with California’s Residential Building Code is inadequate at controlling combustion pollutants from natural gas burners and particulate matter produced during cooking. Effectiveness is further limited by misperceptions that kitchen ventilation is infrequently needed. This project developed the technical basis for updating kitchen ventilation requirements to protect health in new California homes, especially in smaller homes common among low-income renters. Tasks included (1) a field study of ventilation equipment performance and indoor air quality in 23 low-income apartments at four sites; (2) analysis of range hood use related to cooking time and household parameters using data from 54 houses and 17 low-income apartments; (3)a measurement-based study to quantify performance of over-the-range microwave ovens with integrated exhaust fans;and (4) pollutant exposure simulations to inform capture efficiency standards.The field study found operational deficiencies with mechanical ventilation systems in a substantial fraction of low-income apartments that affected performance, resulting in higher exposures to pollutants generated indoors. Using gas cooking burners produced high short-term and weekly time-averaged nitrogen dioxide in apartments.Range hoods were used more frequently with cooking in houses (36percent) than apartments (28percent); use increased with overall cooking frequency in a home and with duration of cooktop but not oven events; actual use was correlated to, but lower than,self-reported use;and use was more frequent in houses when cooking generated any fine particulate matter (PM2.5)or when high PM2.5resulted from cooking in apartments. Performance of over-the-range microwaves with integrated exhaust fans was similar to that of range hoods of comparable price. Simulation analysis found that performance standards need to be updated to ensure that kitchen exhaust ventilation adequately protects for substantial cooking in new California residences.

03 NATURAL GAS↗

Spool Valve for Switching Air Flows Between Two Beds

U.S. Patent 6,142,151 describes a dual-bed ventilation system for a space suit, with emphasis on a multiport spool valve that switches air flows between two chemical beds that adsorb carbon dioxide and water vapor. The valve is used to alternately make the air flow through one bed while exposing the other bed to the outer-space environment to regenerate that bed through vacuum desorption of CO2 and H2O. Oxygen flowing from a supply tank is routed through a pair of periodically switched solenoid valves to drive the spool valve in a reciprocating motion. The spool valve equalizes the pressures of air in the beds and the volumes of air flowing into and out of the beds during the alternations between the adsorption and desorption phases, in such a manner that the volume of air that must be vented to outer space is half of what it would be in the absence of pressure equalization. Oxygen that has been used to actuate the spool valve in its reciprocating motion is released into the ventilation loop to replenish air lost to vacuum during the previous desorption phase of the operating cycle.

Dean, W. Clark↗

Thermal Performance Testing of EMU and CSAFE Liquid Cooling Garments

Future exploration missions require the development of a new liquid cooling garment (LCG) that offers greater system reliability, is more comfortable, and maximizes thermal performance. To inform the development of a future LCG a thermal performance test was conducted to evaluate three factors: (1) the effect of the thermal comfort undergarment (TCU) on tactile and thermal comfort, (2) the comparable thermal performance of an CSAFE developed engineering evaluation unit (EEU) LCG, which uses a commercial-off-the-shelf (COTS) wicking garment as the base, and (3) the performance of a torso or upper body only LCG configuration to evaluate a proposed auxiliary loop configuration. To evaluate the thermal performance of each configuration a metabolic suit test was conducted, utilizing suited subjects to generate metabolic heat by walking on a treadmill at various speeds. Three (3) test subjects of similar height and weight produced a metabolic load for five tests by either resting (300-600 BTU/hr), walking at a slow pace (1200 BTU/hr), and walking at a brisk pace (2200 BTU/hr). During the test, data was collected that would allow us to track the heat transfer to the LCG and ventilation system to determine the thermal performance of the LCG configurations. Four different test configurations were tested, with one configuration tested twice. The test results show that the CSAFE EEU LCG and EMU LCG had comparable performance. The testing also showed that an auxiliary loop LCG, sized similarly to the shirt-only configuration, should provide adequate cooling for contingency scenarios. Finally, the testing showed the previous analysis that assumed a UA deterioration from the TCU was too conservative and the TCU may prove to be acceptable for future development with additional analysis and testing.

Rhodes, Richard↗

Quantitative and three-dimensional assessment of holdup material

Nuclear material deposited in equipment, transfer lines, and ventilation systems of a processing facility is usually referred to as holdup. Operators need to know the location and amount of holdup in their facility for radiation safety and material accountability. In this work, we propose to use an array of detectors co-axial to the inspected pipe to measure the holdup material. This method is implementable into an automated system capable of crawling on surfaces and pipes of various curvatures, which would enable faster, easier, and more accurate holdup safeguards measurements. We first demonstrated that the current holdup assay procedure could lead to a non-negligible bias in the estimate of special nuclear material mass, due to the simplified assumption of deposited geometry introduced by the Generalized Geometry Holdup (GGH) model. The new approach consists of imaging the inner holdup material by characterizing the detector array’s response and unfolding it from the measured light output. Our experimental proof of principle consists of three NaI(Tl) detectors surrounding an aluminum pipe containing two cesium-137 ( 137 Cs) sources. We derived the source distribution inside the pipe by first calculating the detector response matrix using a method adaptive to the surface geometry of the object containing the measured holdup material. Creating a matrix of the detector array’s measured counts, we then proceed to solve an inverse problem, resulting in an accurately located source position and activity distribution within the response matrix’s spatial resolution. Furthermore, we then developed a simulated model of the envisioned experimental setup, which accurately described both the activity and position of the source in 2D. Finally, we extended our model onto a discretized three-dimensional model of the system, encompassing 36 detectors. The model was simulated to measure the source distribution and activity of multiple sources in pipes of varied geometries, which could then be conveniently translated to a real-time holdup measurement protocol. For the 3D simulation of four different source geometries, the model accurately localized the source position in 3D, while the activity retained a maximum relative error of ±5.32%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cyclic Background Noise Variations on Infrasound Microbarometers From Micrometeorology and Human Activity

Infrasound microbarometers deployed on the Earth's surface capture pressure fluctuations and acoustic signatures, revealing trends in surface wind speed and cycles in ambient sound. Previous studies investigated wind noise trends at quarter day resolution and urban acoustic background variations on hourly to weekly scales. Cyclic variations at sub-hourly resolution over local distances remain unaddressed. We show that topography-driven micrometeorology impacts diurnal background noise levels below 10 Hz. Anthropogenic noise occurs over daily and weekly cycles, with inputs from traffic, ventilation systems, and power lines. These noise patterns vary at stations spaced less than a kilometer apart. We observe these phenomena by using a circular spectrogram to visualize frequency trends over a periodic temporal scale. This study demonstrates that infrasound microbarometer deployments can highlight localized wind patterns and time scales of human activity. The results suggest that future microbarometer deployments may benefit from site noise surveys before selecting final sensor locations.

Malach, Amrit Kaur [Sandia National Lab. (SNL-CA),↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A Scoping Study to Develop a Computational Fluid Dynamics Based Model to Predict Radiological Materials Packaging Temperatures within a Generic Staging Building

The objective of this work is to perform computational fluid dynamics simulations of a ventilated radiological-material-package staging building to determine the effect of including or excluding a variety of physical effects and computational methods on both the predicted package temperatures and required computational resources. The generic building contains 640 drum-packages containing heat-generating, radiological material supported on four racks that are eight levels tall. Additionally, there is a forced ventilation system, lighting, and insulated walls. Computational models were constructed that included or excluded (a) shelving, (b) effects of unsteadiness, and (c) radiation heat transfer. Simulations with each drum modeled separately were compared to simpler simulations with sets of four drums represented by an equivalent box-package. These models employed between 106 to 107 elements. Steady state simulations predicted package temperatures that were within 0.1°C of simulations that included transient effects and required only one-eighth the computational resources. Calculations that excluded shelving predicted temperatures within 0.6°C of simulations that included shelving and required one-fourth the computational resources. Excluding radiation heat transfer systematically increased temperatures by around 1.5°C but reduced computational resources by a factor of four. The box-package model reduced the computational resources by a factor of 3, but systematically predicted higher temperatures by around 1.1°C. These results will be used to develop an efficient computational fluid dynamics model to assess the ability of different staging building designs to prevent the temperature of package components from exceeding specified limits.

42 ENGINEERING↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NSRD-20, Functional Testing of Novel MTC HEPA Filtration Media

To improve the safety of Department of Energy (DOE) nuclear facilities, this project aimed to develop ceramic high efficiency particulate air (HEPA) filters that also create a low pressure-drop (dP) in use. The filters under consideration use mini-tubular ceramic (MTC) HEPA filtration media made with different architectures. Once successful, this project will reduce life-cycle costs, including safety basis, operational, and waste-disposal costs. The technology’s mini-tubular geometry is known to reduce dP when compared to flow through membranes of equivalent mass and surface area. Low dP facilitates retrofitting advanced filters into existing DOE facilities to make them safer while simultaneously reducing operational costs. Operations of ventilation systems are a key cost driver for DOE nuclear facilities; reducing dP can significantly reduce DOE’s operational costs. However, the filtration efficiency (FE) of this type of filtration media depends on the architecture of the filter media in an unknown way and requires testing. Functional testing of filtration media with different architectures will establish the performance of the filtration media and will enable development of guidance on design requirements to optimize filter performance.

36 MATERIALS SCIENCE↗

White Paper on Lithium-Ion Battery Safety for use in Safety Planning at the Waste Isolation Pilot Plant

The Waste Isolation Pilot Plant (WIPP) is an underground facility designed to safely dispose of radioactive waste. The WIPP uses many heavy vehicles to transport materials and equipment underground. Most of these vehicles are powered by traditional internal combustion engines (ICE) with diesel fuel. Recently, electric vehicles (EVs) powered with batteries have been used at the WIPP. EVs have very low operational and maintenance costs, not considering battery replacements, and they have zero emissions during operation. This absence of emissions makes them ideal for underground facilities with limited ventilation. Even if a facility has robust ventilation normally, ventilation systems can break down leading to restrictions in ICE powered operations. Figure 1 shows a rendering of the WIPP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY↗

Initial Testing of a Small Gamma Detector (GR1+) for Detection of Holdup in HEPA Filters

Measuring and assessing holdup is a key component of proper inventorying of a Material Balance Area (MBA). The Nuclear Material Control and Accountability (NMC&A) group at the Savannah River Site is responsible for ensuring that the methods used to determine holdup in the MBAs are valid for the conditions of that MBA. Holdup can be contained inside processing equipment or inside ventilation systems that that pulls air out of the glovebox through HEPA filters and stainless steel piping.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles

This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO 2 accumulation patterns are of great interest because CO 2 can have negative cognitive effects at higher concentrations and also since CO 2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO 2 levels inside the vehicle’s cabin. The CO 2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h –1 ]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) – 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.

passive sensing↗

Numerical techniques in linear duct acoustics

Both finite difference and finite element analyses of small amplitude (linear) sound propagation in straight and variable area ducts with flow, as might be found in a typical turboject engine duct, muffler, or industrial ventilation system, are reviewed. Both steady state and transient theories are discussed. Emphasis is placed on the advantages and limitations associated with the various numerical techniques. Examples of practical problems are given for which the numerical techniques have been applied.

Baumeister, K. J.↗

Design and development of a trace contaminant removal canister for Spacelab

The paper describes the overall approach used by NASA-MSFC to design and develop a trace contaminant removal canister for Spacelab. The elements of this approach include the establishment of a trace contaminant load model, analysis and testing to define a preliminary design, development testing to verify the adequacy of the selected design, and testing to define a suitable canister location in the transfer tunnel ventilation system. The canister utilizes a catalyst material which is effective in removing carbon monoxide at room temperature, as well as plain and acid treated charcoal. The canister alone will control all contaminants in the load model below their maximum allowable concentration (MAC) levels without assistance from the baseline environmental control system (ECS) except for methyl alcohol and ammonia.

Ray, C. D.↗

Measurements of cabin and ambient ozone on B747 airplanes

In response to recent concerns over possibly high ozone levels in the cabins of aircraft flying in the stratosphere, simultaneous measurements of the cabin and ambient ozone levels have been made as part of the NASA Global Atmospheric Sampling Program. Examples of the data taken on commercially operated Boeing 747-100 and 747SP airplanes are given for selected flights, together with summary statistics of over 5600 observations. Cabin ozone levels vary with the ambient level and, for unmodified aircraft, are higher on the 747SP than on the 747-100. Modifications to the ventilation system of the 747SP reduced cabin ozone levels by varying amounts up to a factor of 14.

Nastrom, G. D.↗

Numerical techniques in linear duct acoustics - A status report

A review is presented covering both finite difference and finite element analysis of small amplitude (linear) sound propagation in straight and variable area ducts with flow, as might be found in a typical turbojet engine duct, muffer, or industrial ventilation system. Both 'steady' state and transient theories are discussed. Emphasis is placed on the advantages and limitations associated with the various numerical techniques. Examples of practical problems are given for which the numerical techniques have been applied.

Baumeister, K. J.↗