Space Shuttle External Tank Gaseous Oxygen Vent System

Two problems had to be solved to assure successful elimination of ice on the External Tank (ET). First, an access/support structure was provided from the Launch Complex 39A Fixed Service Structure to the vicinity of the nose cone on the ET approximately 82.3 meters (270 feet) above the surface of the pad and 22.9 meters (75 feet) from the face of the FSS. Second, an umbilical was designed and tested that would seal around the ET gaseous oxygen (GOX) vent louvers and not allow ice to form on the tank or the umbilical. A modified Apollo service arm was chosen. An inflatable vent seal subsystem was chosen, providing a cloth seal around each vent louver with an internal annulus to provide a path for the gaseous oxygen from the ET to a hard duct on the swing arm.

Franklin, W. G.↗

Ground test of a large scale 'D' vented thrust deflecting nozzle

Future V/STOL aircraft will require efficient techniques for changing the thrust vector from the vertical direction for VTOL operation to the horizontal direction for conventional flight. Most V/STOL concepts utilize thrust vectoring nozzles to provide this variation in the thrust vector direction. An experimental test program was initiated to demonstrate the capabilities of a large scale 'D' vented thrust deflecting system coupled with a high bypass ratio turbofan engine. Data were obtained for a 'D' vented nozzle mounted behind a YTF-34-F5 turbofan engine. Preliminary data are presented for a variety of test conditions. Attention is given to aspects of 'D' vented nozzle design, the test apparatus, engine-nozzle compatibility, exit area variation, longitudinal vectoring performance, nozzle temperature distribution, and large scale - small scale comparisons.

Rosenberg, E. W.↗

Sulphur isotopic compositions of deep-sea hydrothermal vent animals

The S-34/S-32 ratios of tissues from vestimentiferan worms, brachyuran crabs, and giant clams living around deep hydrothermal vents are reported. Clean tissues were dried, ground, suspended in 0.1 M LiCl, shaken twice at 37 C to remove seawater sulfates, dried at 60 C, combusted in O2 in a Parr bomb. Sulfur was recovered as BaSO4, and the isotopic abundances in SO2 generated by thermal decomposition of 5-30-mg samples were determined using an isotope-ratio mass spectrometer. The results are expressed as delta S-34 and compared with values measured in seawater sulfates and in normal marine fauna. The values ranged from -4.7 to 4.7 per thousand, comparable to vent sulfide minerals (1.3-4.1 per thousand) and distinct from seawater sulfates (20.1 per thousand) and normal marine fauna (about 13-20 per thousand). These results indicate that vent sulfur rather than seawater sulfur is utilized by these animals, a process probably mediated by chemoautotrophic bacteria which can use inorganic sulfur compounds as energy sources.

Fry, B.↗

Vent modification of large ribbon parachutes to enhance cluster performance

Due to uneven load sharing and lagging inflation rates, the design of the Large Main Parachute (LMP) cluster, used to recover the Space Shuttle steel case Solid Rocket Boosters, had to be modified. The cause of the problem was excessive variation in effective porosity in the crown area of the LMP during first stage inflation. The design modification consisted of adding horizontal ribbons above the existing vent band to reduce the vent porosity and better control the position and attitude of the vent lines. Performance of modified LMP's since introduction indicates that the load sharing between the clustered chutes has been significantly improved.

Kolega, D. J.↗

Passive venting system for modifying cavity flowfields at supersonic speeds

The drag of airfoils in transonic flow can be reduced through the use of a passive venting system that employs a porous plate for part of the airfoil upper surface with a vent chamber underneath the porous plate Attention is given to the results obtained with a wind tunnel model employing such a porous floor system. This passive venting system has been used to extend the length/height value before the onset of high drag-producing closed cavity flow at supersonic speeds.

Wilcox, Floyd J., Jr.↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing state, but then becomes less significant.

Chato, David J.↗

Improved thermodynamic modelling of the no-vent fill process and correlation with experimental data

The United States plans to establish a permanent manned presence in space and to explore the Solar System have created the need to efficiently handle large quantities of subcritical cryogenic fluids, particularly propellants such as liquid hydrogen and liquid oxygen, in low- to zero-gravity environments. One of the key technologies to be developed for fluid handling is the ability to transfer the cryogens between storage and spacecraft tanks. The no-vent fill method has been identified as one way to perform this transfer. In order to understand how to apply this method, a model of the no-vent fill process is being developed and correlated with experimental data. The verified models then can be used to design and analyze configurations for tankage and subcritical fluid depots. This paper discusses the development of an improved macroscopic thermodynamic model of the no-vent fill process and correlates the analytical results from the computer program implementation of the model with experimental results for two different test tanks at NASA Lewis Research Center.

Taylor, W. J.↗

Improved thermodynamic modeling of the no-vent fill process and correlation with experimental data

The United States' plans to establish a permanent manned presence in space and to explore the Solar System created the need to efficiently handle large quantities of subcritical cryogenic fluids, particularly propellants such as liquid hydrogen and liquid oxygen, in low- to zero-gravity environments. One of the key technologies to be developed for fluid handling is the ability to transfer the cryogens between storage and spacecraft tanks. The no-vent fill method was identified as one way to perform this transfer. In order to understand how to apply this method, a model of the no-vent fill process is being developed and correlated with experimental data. The verified models then can be used to design and analyze configurations for tankage and subcritical fluid depots. The development of an improved macroscopic thermodynamic model is discussed of the no-vent fill process and the analytical results from the computer program implementation of the model are correlated with experimental results for two different test tanks.

Taylor, William J.↗

Hydrogen no-vent fill testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injection

A total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.

Moran, Matthew E.↗

Vented Tank Resupply Experiment (VTRE) for In-space Technology Experiment Program (IN-STEP)

An overview of the Vented Tank Resupply Experiment (VTRE) program is presented in outline and graphical form. The goal of the program is to develop, design, build and provide flight and post flight support for a Shuttle Hitchhiker Experiment to investigate and demonstrate vented tank venting in space. Program schedules and experiment subsystem schematics are presented and specific technical objectives, power requirements, payload assemblies, Hitchhiker canister integration, and orbiter mission approach are addressed.

Source record↗

Pressure dither in venting analyses

Venting analyses simulate the time-dependent flow of air or another gas from one compartment to another, or to an ambient profile. The flow through the vent connecting the compartments is assumed to be one-dimensional, quasi-steady, and isentropic with an empirical discharge coefficient included to account for irreversible flow losses. When a venting analysis is performed numerically, an upper limit on the accuracy exists due to the effects of the numerical integration method. Because this manifests itself in a first-order method by a rapid oscillation about the true answer, this phenomenon is referred to as pressure dither. This paper explores the origin of the phenomenon and gives simple formulae for predicting when it will occur and the greatest achievable accuracy for a given time step.

Fay, John F.↗

Ground testing for the no-vent fill of cryogenic tanks - Results of tests for a 71 cubic foot tank

NASA Lewis Research has been investigating the no-vent till method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. Twenty two tests were conducted, ten with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia; transfer pressures of 20, 30, and 45 psia; and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool-down of the higher starting wall temperature fills.

Chato, David J.↗

The Prevention of Ice Formation on Gasoline Tank Vents

This investigation was conducted in the refrigerated wind tunnel at the Langley Memorial Aeronautical Laboratory, Langley Field, Va., to determine a suitable method for preventing the formation of ice on the vents of airplane gasoline tanks. Tests were made on a variety of vent forms arranged in a number of different orientations relative to the direction of the air stream. Both the size of the tube and its orientation were found to be of great importance. Small tubes, under equal circumstances, were found to freeze over far more rapidly than large ones. Tubes pointing downstream, or shielded in other ways, appear to be perfectly immune against this hazard. A tube 3/4 inch in diameter with the opening pointing downstream is finally recommended as being the safest choice of gas tank vent.

Theodorsen, Theodore↗

Ground testing for the no-vent fill of cryogenic tanks: Results of tests for a 71 cubic foot tank

NASA Lewis Research has been investigating the no-vent fill method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. 22 tests were conducted, 10 with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia, transfer pressures of 20, 30, and 45 psia, and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool down of the higher starting wall temperature fills.

Chato, David J.↗

Experiments On No-Vent Filling Of A Tank With Liquid H(2)

Report describes experiments on no-vent filling of insulated, vacuum-jacketed tank with liquid hydrogen. Experiments conducted to ascertain feasibility of no-vent filling of tanks with cryogenic liquids in zero gravity, where filling with venting as in normal gravity could cause substantial loss of liquids.

Chato, D. J.↗

Spacecraft Compartment Venting

At various time concerns have been expressed that rapid decompressions of compartments of gas pockets and thermal blankets during spacecraft launches may have caused pressure differentials across their walls sufficient to cause minor structural failures, separations of adhesively-joined parts, ballooning, and flapping of blankets. This paper presents a close form equation expressing the expected pressure differentials across the walls of a compartment as a function of the external to the volume pressure drops, the pressure at which the rates occur and the vent capability of the compartment. The pressure profiles measured inside the shrouds of several spacecraft propelled by several vehicles and some profiles obtained from ground vacuum systems have been included. The equation can be used to design the appropriate vent, which will preclude excessive pressure differentials. Precautions and needed approaches for the evaluations of the expected pressures have been indicated. Methods to make a rapid assessment of the response of the compartment to rapid external pressure drops have been discussed. These are based on the evaluation of the compartment vent flow conductance, the volume and the length of time during which the rapid pressure drop occurs.

Scialdone, John J.↗

Medium Fidelity Simulation of Oxygen Tank Venting

The item to he cleared is a medium-fidelity software simulation model of a vented cryogenic tank. Such tanks are commonly used to transport cryogenic liquids such as liquid oxygen via truck, and have appeared on liquid-fueled rockets for decades. This simulation model works with the HCC simulation system that was developed by Xerox PARC and NASA Ames Research Center. HCC has been previously cleared for distribution. When used with the HCC software, the model generates simulated readings for the tank pressure and temperature as the simulated cryogenic liquid boils off and is vented. Failures (such as a broken vent valve) can be injected into the simulation to produce readings corresponding to the failure. Release of this simulation will allow researchers to test their software diagnosis systems by attempting to diagnose the simulated failure from the simulated readings. This model does not contain any encryption software nor can it perform any control tasks that might be export controlled.

Sweet, Adam↗