Wind tunnel turning vanes of modern design

Rehabilitation of the Altitude Wind Tunnel includes the need for new corner turning vanes to match its upgraded performance. The design and experimental performance results from a 0.1-full scale model of the highest speed corner (M = 0.35) are presented and discussed along with some two dimensional inviscid analyses of two vaned corners. With a vane designed by an inverse two dimensional technique, the overall corner loss was about 12 percent of the inlet dynamic pressure of which about 4 percent was caused by vane skin friction. Comparable values with a conventionally designed circular arc vane were about 14 percent overall with about 7 percent due to skin friction.

Gelder, T. F.↗

A theoretical study of fluid forces on a centrifugal impeller rotating and whirling in a vaned diffuser

The fluid forces on a centrifugal impeller rotating and whirling in a vaned diffuser are analyzed on the assumption that the number of impeller and diffuser vanes is so large that the flows are perfectly guided by the vanes. The flow is taken to be two dimensional, inviscid, and incompressible, but the effects of impeller and diffuser losses are taken into account. It is shown that the interaction with the vaned diffuser may cause destabilizing fluid forces. From these discussions, it is found that the whirling forces are closely related to the steady head-capacity characteristics of the impeller. This physical understanding of the whirling forces can be applied also to the cases with volute casings. At partial capacities, it is shown that the impeller forces change greatly when the flow rate and whirl velocity are near to the impeller or vaned diffuser attributed rotating stall onset capacity, and the stall propagation velocity, respectively. In such cases the impeller forces may become destabilizing for impeller whirl.

Tsujimoto, Yoshinobu↗

Experimental investigation of rotor-stator interaction in a centrifugal pump with several vaned diffusers

Steady and unsteady diffuser vane pressure measurements have been conducted with a two-dimensional test impeller, in an experimental investigation of rotor-stator interaction within a centrifugal pump having several vaned diffusers, under conditions of different flow coefficients and different radial gaps between the impeller blade trailing edge and the diffuser vane leading edge. The largest pressure fluctuations on the diffuser vanes and the impeller blades were found to be of the same order of magnitude as the total pressure rise across the pump. Increasing the number of diffuser vanes was found to result in a significant decrease of impeller blade pressure fluctuations.

Arndt, N.↗

Experimental measurements and analytical analysis related to gas turbine heat transfer. Part 1: Time-averaged heat-flux and surface-pressure measurements on the vanes and blades of the SSME fuel-side turbine and comparison with prediction. Part 2: Phase-resolved surface-pressure and heat-flux measurements on the first blade of the SSME fuel-side turbine

Time averaged Stanton number and surface-pressure distributions are reported for the first-stage vane row, the first stage blade row, and the second stage vane row of the Rocketdyne Space Shuttle Main Engine two-stage fuel-side turbine. Unsteady pressure envelope measurements for the first blade are also reported. These measurements were made at 10 percent, 50 percent, and 90 percent span on both the pressure and suction surfaces of the first stage components. Additional Stanton number measurements were made on the first stage blade platform blade tip, and shroud, and at 50 percent span on the second vane. A shock tube was used as a short duration source of heated and pressurized air to which the turbine was subjected. Platinum thin-film heat flux gages were used to obtain the heat flux measurements, while miniature silicon-diaphragm flush-mounted pressure transducers were used to obtain the pressure measurements. The first stage vane Stanton number distributions are compared with predictions obtained using a version of STAN5 and a quasi-3D Navier-Stokes solution. This same quasi-3D N-S code was also used to obtain predictions for the first blade and the second vane.

Source record↗

The Effect of Vane-Blade Spacing on Transonic Turbine Stage Performance

This paper presents the results of a computational study on the effect of axial spacing between the vane and blade rows of a transonic turbine stage. The study was performed on the mid-span section of a high-pressure turbine stage using a quasi-3D, unsteady Navier-Stokes solver that provides a fully interactive vane-blade unsteady flow solution. Three different cases were considered, corresponding to axial spacings of 20%, 40%, and 60% of the vane axial chord. The calculated vane and blade pressure distributions for the 40 percent case were found to compare favorably with experimental measurements acquired in a short-duration shock tunnel. In addition, the analysis shows a marked increase in the amplitude of the unsteady pressure fluctuations on the vane and blade surfaces as the spacing decreases. Time-averaged stage adiabatic efficiency predictions for each case are presented to show the effect of spacing on aerodynamic performance.

F J Kelecy↗

Active Control of Fan Noise by Vane Actuators

An active noise control system for ducted fan noise was built that uses actuators located in stator vanes. The actuators were piezoelectric benders manufactured using the THUNDER technology and were custom designed for the application. The active noise control system was installed in the NASA ANCF rig. Four actuator array with a total of 168 actuators in 28 stator vanes were used. Simultaneous reductions of acoustic power in both the inlet and exhaust duct were demonstrated for a fan disturbance that contained two radial mode orders in both inlet and exhaust. Total power levels in the target modes were reduced by up to 9 dB in the inlet and total tone levels by over 6 dB while exhaust power levels were reduced by up to 3 dB. Far field sound pressure level reductions of up to 17 dB were observed. A simpler control system, matched to the location of the disturbance with two radial actuator arrays, was demonstrated to control total acoustic power in four disturbance modes simultaneously in inlet and exhaust. The vane actuator met the requirements given for the ANCF, although in practice the performance of the system was limited by the constraints of the power amplifiers and the presence of control spillover. The vane actuators were robust. None of the 168 vane actuators failed during the tests.

Curtis, Alan R. D.↗

Infrared Low Temperature Turbine Vane Rough Surface Heat Transfer Measurements

Turbine vane heat transfer distributions obtained using an infrared camera technique are described. Infrared thermography was used because noncontact surface temperature measurements were desired. Surface temperatures were 80 C or less. Tests were conducted in a three vane linear cascade, with inlet pressures between 0.14 and 1.02 atm., and exit Mach numbers of 0.3, 0.7, and 0.9, for turbulence intensities of approximately 1 and 10%. Measurements were taken on the vane suction side, and on the pressure side leading edge region. The designs for both the vane and test facility are discussed. The approach used to account for conduction within the vane is described. Midspan heat transfer distributions are given for the range of test conditions.

Boyle, R. J.↗

Comparison of Predicted and Measured Turbine Vane Rough Surface Heat Transfer

The proposed paper compares predicted turbine vane heat transfer for a rough surface over a wide range of test conditions with experimental data. Predictions were made for the entire vane surface. However, measurements were made only over the suction surface of the vane, and the leading edge region of the pressure surface. Comparisons are shown for a wide range of test conditions. Inlet pressures varied between 3 and 15 psia, and exit Mach numbers ranged between 0.3 and 0.9. Thus, while a single roughened vane was used for the tests, the effective rougness,(k(sup +)), varied by more than a factor of ten. Results were obtained for freestream turbulence levels of 1 and 10%. Heat transfer predictions were obtained using the Navier-Stokes computer code RVCQ3D. Two turbulence models, suitable for rough surface analysis, are incorporated in this code. The Cebeci-Chang roughness model is part of the algebraic turbulence model. The k-omega turbulence model accounts for the effect of roughness in the application of the boundary condition. Roughness causes turbulent flow over the vane surface. Even after accounting for transition, surface roughness significantly increased heat transfer compared to a smooth surface. The k-omega results agreed better with the data than the Cebeci-Chang model. However, the low Reynolds number k-omega model did not accurately account for roughness when the freestream turbulence level was low. The high Reynolds number version of this model was more suitable when the freestream turbulence was low.

Boyle, R. J.↗

Infrared Low-Temperature Turbine Vane Rough Surface Heat Transfer Measurements

Turbine vane heat transfer distributions obtained using an infrared camera technique are described. Infrared thermography was used because noncontact surface temperature measurements were desired. Surface temperatures were 80 C or less. Tests were conducted in a three-vane linear cascade, with inlet pressures between 0.14 and 1.02 atm, and exit Mach numbers of 0.3, 0.7, and 0.9, for turbulence intensities of approximately 1 and 10 percent. Measurements were taken on the vane suction side, and on the pressure side leading edge region. The designs for both the vane and test facility are discussed. The approach used to account for conduction within the vane is described. Midspan heat transfer distributions are given for the range of test conditions.

Boyle, R. J.↗

An MDOE Assessment of Nozzle Vanes for High Bypass Ratio Jet Noise Reduction

The effect of airfoil-shaped vanes placed in the fan stream of a BPR 8 coannular nozzle model system on the resulting jet noise was investigated. The experiments used a Modern Design of Experiments approach to investigate the impact of a range of vane parameters on the noise reduction achieved at representative takeoff conditions. The experimental results showed that the installation of the vanes decreased low frequency noise radiation in the downstream peak-noise direction and increased high frequency noise in the upstream direction. Results also showed that improper selection of the vane configuration resulted in increased low frequency noise radiation in the upstream direction. Large angles of attack are shown to reduce noise near the peak jet noise angle and increase noise in the upstream direction. The MDOE analysis yields an optimum design that minimizes perceived noise levels. Limited data taken with a BPR 5 nozzle system showed that the vanes result in better effective perceived noise reduction for lower bypass ratio nozzles than for the BPR 8 model.

Henderson, Brenda↗

Improving the Hydrodynamic Performance of Diffuser Vanes via Shape Optimization

The performance of a diffuser in a pump stage depends on its configuration and placement within the stage. The influence of vane shape on the hydrodynamic performance of a diffuser has been studied. The goal of this effort has been to improve the performance of a pump stage by optimizing the shape of the diffuser vanes. The shape of the vanes was defined using Bezier curves and circular arcs. Surrogate model based tools were used to identify regions of the vane that have a strong influence on its performance. Optimization of the vane shape, in the absence of manufacturing, and stress constraints, led to a nearly nine percent reduction in the total pressure losses compared to the baseline design by reducing the extent of the base separation.

Goel, Tushar↗

Sideload vanes for fluid pump

A fluid pump assembly includes a rotatable component that can be rotated about an axis and a static vane assembly located adjacent to the rotatable component. The static vane assembly includes a circumferential surface axially spaced from the rotatable component, and one or more vanes extending from the circumferential surface toward the rotatable component. The one or more vanes are configured to produce a radial load on the rotatable component when the rotatable component is rotating about the axis and a fluid is present between the static vane assembly and the rotatable component.

Erler, Scott R.↗

Reduction of Unsteady Forcing in a Vaned, Contra-Rotating Transonic Turbine Configuration

HPT blade unsteadiness in the presence of a downstream vane consistent with contra-rotation is characterized by strong interaction at the first harmonic of downstream vane passing. E An existing stage-and-one-half transonic turbine rig design was used as a baseline to investigate means of reducing such a blade-vane interaction. E Methods assessed included: Aerodynamic shaping of HPT blades 3D stacking of the downstream vane Steady pressure-side blowing E Of the methods assessed, a combination of vane bowing and steady pressure-side blowing produced the most favorable result. E Transonic turbine experiments are planned to assess predictive accuracy for the baseline turbine and any design improvements.

Clark, John↗

Preliminary Study of Heat Pipe Turbine Vane Cooling in the NASA N+3 Reference Engine

This paper investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.

Gas Turbine↗

Preliminary Study of Heat Pipe Turbine Vane Cooling in the NASA N+3 Reference Engine

This investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.

Gas Turbine↗

Benchmark Performance Metrics of a Vane Propellant Management Device for a 0.15 m3 Liquid Hydrogen Tank

The use of cryogenic propellants has and will continue to play an integral role in manned-space exploration due the high specific impulses offered and its ubiquity through in-situ resource utilization. But guaranteeing vapor-free transfer of such low-surface tension liquids is difficult for traditional capillary-action propellant management devices (PMDs). Screen-channel liquid acquisition devices and compliant origami bladders are potential solutions, but to quantify the benefits these technologies offer, this paper present a cast study analyzing the performance metrics of an orthodox vane PMD as a benchmark for comparison. A 0.15 m3 liquid hydrogen tank at 20.3 K and 103 kPa was selected for study. Then assuming no body forces and no heat transfer (for simplicity), a steady-state 1-D differential equation was numerically solved in tandem with four possible wetted area configurations to yield an expulsion efficiency for a theoretically maximum inputted expulsion flow rate. Maximization of the flow rate was constrained by the onset of choked flow. Additional inputs, including vane height and vane number, were parametrically varied between 0.1 – 10 cm and 4 – 28 vanes, respectively.

Liquid Acquisition Device↗

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

vaned diffuser↗

Experimental and Numerical Investigation of the NASA High Efficiency Centrifugal Compressor Vaned Stage Geometry and Aerodynamic Performance

Since its inception in the early 2010s, the NASA High Efficiency Centrifugal Compressor (HECC) has been enigmatic for the propulsion research community: experimental data and numerical simulations of the stage have generally not aligned in their quantifications of performance metrics. Typically, the fault for these disagreements is assigned to the numerical simulations as the simulations are models, and models are inherently incomplete representations of the experiment. This “incompleteness” may manifest in assumptions regarding roughness or heat transfer, simplifications of the flow path (i.e., neglecting bleed flows), or the oft-scapegoated turbulence model. In the case of HECC, recent work showed unexpected discrepancies between the intended impeller geometry defined in the design report (termed Design-Intent) and the manufactured impeller used in the experimental campaigns (termed As-Manufactured). That work used numerical simulations to establish that the geometric differences between the Design-Intent and As-Manufactured impellers were significant enough to result in drastically different performance predictions for the HECC vaneless diffuser configuration. The Design-Intent impeller simulations over predicted the performance relative to the experiment, whereas the As-Manufactured simulations better represented the experimental data, both in terms of one-dimensional performance metrics and spanwise flow profiles. This effort expands on that work by examining in detail the geometry and aerodynamic performance of the HECC vaned diffuser configuration. Further differences between the Design-Intent and As-Manufactured geometries have been discovered in the vaned diffuser and exit guide vanes, and these differences are documented herein. The summations of the geometric differences for all of the components were used to create two numerical models of HECC vaned diffuser configuration: the Design-Intent simulations which are generated from the original geometry definitions given in the design report and the As-Manufactured simulations which are the best available representation of the manufactured compressor hardware used in the experimental test campaigns. In congruence with the earlier vaneless diffuser work, the numerical predictions of the Design-Intent choked mass flow rate, total pressure ratio, and efficiency were notably greater than that of the As-Manufactured simulations. To increase confidence in the experimental dataset, measurements from a recent test campaign conducted in 2024 are used to validate the original experimental data acquired from 2012 to 2014 with good repeatability overall, especially considering the passage of time and differences in the data acquisition systems between the test campaigns. Both numerical simulations were then extensively evaluated against the experimental data. The As-Manufactured simulations provided better estimates of the stage performance than the Design-Intent cases in terms of most performance metrics. Nonetheless, more detailed results still show opportunities for improvement. Despite a more accurate representation of the physical hardware, characterization of the impeller work input remains a challenge even for rigorously developed numerical models.

centrifugal compressor↗