Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Utility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Climate Adaptation Approaches for Water and Electric Utilities: A compendium of existing strategies in a changing climate

Report analyzes plans developed by water and electric utilities to address the impacts of changes in the climate within their service territories. The analysis identifies the main types of changes that utilities address, such as sea level rise, extreme heat, and compound events such as freezing rain/show and extreme wind events. It then identifies adaptation approaches utilities have proposed or adopted to address the changes that are anticipated in their service territories. The report also identifies the mechanisms utilities (and in some cases the governments which the utilities are part of) use to ensure that energy or environmental equity is increased as a result of the resilience program. In summary, the report provides a compendium of adaptation strategies that can be used by others as they review their own need to increase climate resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utility Perspective on Protection Challenges with High Penetration of IBRs

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report / presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Dataset For: A Guide to Residential Energy Storage and Rooftop Solar: State Net Metering Policies and Utility Rate Tariff Structures

Federal and state decarbonization goals have led to numerous financial incentives and policies designed to increase access and adoption of renewable energy systems. In combination with the declining cost of both solar photovoltaic and battery energy storage systems and rising electric utility rates, residential renewable adoption has become more favorable than ever. However, not all states provide the same opportunity for cost recovery, and the complicated and changing policy and utility landscape can make it difficult for households to make an informed decision on whether to install a renewable system. This paper is intended to provide a guide to households considering renewable adoption by introducing relevant factors that influence renewable system performance and payback, summarized in a state lookup table for quick reference. Five states are chosen as case studies to perform economic optimizations based on net metering policy, utility rate structure, and average electric utility price; these states are selected to be representative of the possible combinations of factors to aid in the decision-making process for customers in all states. The results of this analysis highlight the dual importance of both state support for renewables and price signals, as the benefits of residential renewable systems are best realized in states with net metering policies facing the challenge of above-average electric utility rates. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit. Suggested modifications include: location, household load profile, rate tariff structure, and renewable energy system design.

14 SOLAR ENERGY↗

Why Terminology Matters for Successful Rollout of Carbon Dioxide Utilization Technologies

To realize their full sustainability potential, carbon dioxide utilization technologies (carbon capture and utilization/CCU) presently require policy support. Consequently, they require acceptance among a variety of stakeholders in industry, policy making, and in the public sphere alike. While CO 2 utilization is already a topic of discourse among these stakeholders, there is a lack of common terminology to describe such technologies. On the contrary: The present article shows that terminology in the field of CO 2 utilization technologies is currently used inconsistently, and that different designations such as CCU, CCUS, or CDR convey different meanings and contexts. These ambiguities may cause communication problems with regard to policy making, funding proposals, and especially in public discourse. In order to initiate and accompany a goal-oriented and knowledge-based debate on CO 2 utilization technologies in the future, actors in the field are asked to question their own choices of terminology and to assess its accuracy. Acronyms and technical abbreviations are the chief cause of potential misunderstandings, and so should be avoided whenever possible or else include a brief explanation. Consistent and precise use of terminology will facilitate transparent dialogue concerning CO 2 utilization in the future.

54 ENVIRONMENTAL SCIENCES↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

Command and Control of Utilities Systems

The utilities systems that encompass the Y-12 National Security Complex are an integral part of the entire campus, and are essential to maintaining critical mission focus for the site. Although the utilities systems each differ in function, the central production and distribution model creates a common thread on which each system is run. Several incidents in FY 2018 and FY 2019 documented a lack of overall systems control and highlighted the need to create a better command system that could maintain system availability and decrease possible impacts to the surrounding environment. An initial system was started in September of 2019 to better control mechanical utility distribution systems. The measurement of the system can be modeled against a standard command and control related incident. The corresponding work hours from a typical control-related incident were used as key component to this system model. System effectiveness is modeled against utility’s incidents that demonstrate a loss of command and control. The increased simulations of the model also document control can only be effectively contained within the stated time (3-5 years) by yielding more engineers to complete alignments, or drastically reducing the amount of time for alignments. The total control points of the model document a clear correlation between alignments, control points, and the amount of man-hours per incident. Current data shows that actual incident man-hours (1.88 manhours/ incident since initial system implementation) are near expected incident man-hours (1.81 manhours/ incident) with command and control for October 2021, which documents a 33.3% reduction in man-hours/incident since initial system implementation. A conclusion can be drawn that focus on increasing the amount of controlled points in the system can reduce incidents and the decrease the amount of non-value added work to employee’s day-to-day lives, while also achieving a culture that enhances and sustains utilities reliability.

99 GENERAL AND MISCELLANEOUS↗

Seamlessly Fuel Flexible Heat Pump with Optimal Model-based Control Strategies to Reduce Peak Demand, Utility Cost and CO2 Emission

This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.

Li, Zhenning↗

Utility Perspective on Protection Challenges with High IBR Penetration [Slides]

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, this report looks broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the report summarizes on gathered data and internal experiences.

14 SOLAR ENERGY↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility Programs Supporting Customer-Sited Battery Storage: Program Design to Ensure Mutual Benefits

Behind-the-meter (BTM) battery storage, when paired with solar, can benefit customers, utilities, and the electric grid. Some utility-sponsored programs have been implemented offset the cost of customer-owned batteries and recognize the value of batteries to the utility and the grid. This factsheet summarizes existing utility-sponsored battery programs and the value to the stakeholders. It then highlights Wattsmart, the customer-owned battery program offered by Rocky Mountain Power in Utah, and provides lessons-learned from a close look at the impact of the program design on commercial customer participation.

battery↗

Tuning Catalyst Activation and Utilization Via Controlled Electrode Patterning for Low-Loading and High-Efficiency Water Electrolyzers

An anode electrode concept of thin catalyst-coated liquid/gas diffusion layers (CCLGDLs), by integrating Ir catalysts with Ti thin tunable LGDLs with facile electroplating in proton exchange membrane electrolyzer cells (PEMECs), is proposed. The CCLGDL design with only 0.08 mg Ir cm -2 can achieve comparative cell performances to the conventional commercial electrode design, saving ~97% Ir catalyst and augmenting a catalyst utilization to ~24 times. CCLGDLs with regulated patterns enable insight into how pattern morphology impacts reaction kinetics and catalyst utilization in PEMECs. A specially designed two-sided transparent reaction-visible cell assists the in situ visualization of the PEM/electrode reaction interface for the first time. Oxygen gas is observed accumulating at the reaction interface, limiting the active area and increasing the cell impedances. In this work, it is demonstrated that mass transport in PEMECs can be modified by tuning CCLGDL patterns, thus improving the catalyst activation and utilization. The CCLGDL concept promises a future electrode design strategy with a simplified fabrication process and enhanced catalyst utilization. Furthermore, the CCLGDL concept also shows great potential in being a powerful tool for in situ reaction interface research in PEMECs and other energy conversion devices with solid polymer electrolytes.

08 HYDROGEN↗

Improved CO 2 utilization efficiency using membrane carbonation in outdoor raceways

Membrane carbonation, the delivery of CO 2 by diffusion through non-porous hollow fiber membranes, was successfully integrated into outdoor raceways (5.6 m 2 , 900 L) and operated continuously for up to 45 days. Biomass productivity associated with membrane carbonation was similar to using traditional sparging, but the average carbon utilization efficiencies for membrane carbonation was 3-fold higher than for sparging when 100% CO 2 was delivered to both systems. Here, when the pH setpoint was 8.5, growth on ammonium bicarbonate using membrane carbonation achieved a carbon utilization efficiency of 106 ± 45% due to uptake of some carbon from bicarbonate. Using nitrate as the N source had a 78 ± 55% carbon utilization efficiency, due to dissolved inorganic carbon accumulation as the medium alkalinity increased. Lowering the pH setpoint to 8.0 created a carbon-rich environment that decreased the carbon utilization efficiency to 51 ± 27% due to CO 2 off-gassing, but it still was 3-fold higher than with sparging.

54 ENVIRONMENTAL SCIENCES↗

Customer trust in their utility company and interest in household-level battery storage

Here we seek to contribute to understanding household interest in battery storage, particularly the role of customer trust in their utility company. Using data from a survey of California households, we examine whether customers’ trust in their utility company is associated with their interest in battery storage. We find that customer trust that their utility company acts in their best interest is associated with lower levels of interest. Trust that the utility company is competent has some effect. Perceptions that battery storage has financial and environmental benefits and low nonmonetary costs are also associated with higher levels of interest.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Piecewise Linear Optimization for Public EV Charging Depots in Different Utility Environments

With the proliferation of electric vehicles (EVs), EV supply equipment technology is being pushed to increasingly higher power levels, such as extreme fast charging (XFC) at 300kW or more. As more public XFC depots are connected to electric distribution systems, utility operators will mitigate their impact with pricing schemes and programs such as demand response, demand charges, and time-varying prices. In this paper we describe an XFC management system that combines an on-site battery energy storage system and an optimization application that minimizes the cost to operate the depot in light of the utility pricing programs. We have designed the optimizer specially to use fast and simple linear programming so that it can be deployed to low-cost computing platforms. We also describe how several utility pricing schemes are integrated into a single piecewise model, reducing the engineering effort to implement the optimizer in different utility environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UTILITY CONTRIBUTION TO ARC FLASH STUDIES

The utility contribution input to an arc flash study has a significant effect on the output incident energy. Accurate input data can be difficult to obtain from serving utilities or is not consistently available. Defaulting to infinite bus can provide non-conservative results. This focus session poster will discuss the challenges with utility contribution with examples and suggest approaches to calculate conservative incident energy when the utility contribution data is not made available.

Arc flash study, utility contribution data, incide↗

Substitution or Shared Utilization? Intrahousehold Vehicle Use in Mixed-Powertrain Households

While previous research has focused heavily on understanding the factors deriving alternative fuel vehicle adoption rates, there remains a significant gap in understanding how households distribute mileage across different powertrains. This study utilizes data from the 2022 Next Generation National Household Travel Survey to investigate vehicle miles traveled within a sample of 150 plug-in electric vehicle (PEV)-owning households (in which at least one battery electric vehicle is present), characterizing how different powertrains are integrated into daily mobility. Leveraging a Seemingly Unrelated Regression (SUR) framework the study jointly models the utilization of PEVs, hybrid electric vehicles (HEV), and internal combustion engine vehicles (ICEVs) while accounting for household-level substitution effects. The results provide evidence of an asymmetric substitution effect. In households with mixed-powertrain configurations, the ICEV captures a substantially higher share of household miles (compared with the PEV), acting as a utility sponge. Conversely, the model identifies specific socioeconomic and geographic cohorts that prioritize PEV as the primary household workhorse, indicating a systematic sorting effect. Although the sample size limits broader generalizability, these findings suggest that PEVs are used for frequent, specific routine-intensive roles, whereas the ICEV remains a specialized utility vehicle. These insights highlight distinct intrahousehold vehicle use behaviors that are often obscured by aggregate fleetwide statistics.

25 ENERGY STORAGE↗

Utility Finder (U-Finder) Tool

U-Finder allows users to search for and identify local utility partners and electric vehicle charger incentives by state or ZIP code. U-Finder pulls from the Homeland Infrastructure Foundation-Level Database of Electric Retail Service Territories to identify utility service territories. Utility incentive listings are provided by utility associations, and state government incentive listings are pulled from the Alternative Fuels Data Center Laws and Incentives website. ![U Finder landing page](ufinder-landing.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility Rate Database

The Utility Rate Database is a free storehouse of rate structure information from utilities in the United States. The database includes rates for utilities based on the authoritative list of U.S. utility companies maintained by the U.S. Department of Energy’s Energy Information Administration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗