Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ultrasensitive detection of mode splitting in active optical microcavities

Scattering-induced mode splitting in active microcavities is demonstrated. Below the lasing threshold, quality factor enhancement by optical gain allows resolving, in the wavelength-scanning transmission spectrum, of resonance dips of the split modes which otherwise would not be detected in a passive resonator. In the lasing regime, mode splitting manifests itself as two lasing modes with extremely narrow linewidths. Mixing these lasing modes in a detector leads to a heterodyne beat signal whose frequency corresponds to the mode-splitting amount. Lasing regime not only allows ultra-high sensitivity for mode-splitting measurements but also provides an easily accessible scheme by eliminating the need for wavelength scanning around resonant modes. Mode splitting in active microcavities has an immediate impact in enhancing the sensitivity of subwavelength scatterer detection and in studying light-matter interactions in a strong-coupling regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasensitive phase estimation with white light

An improvement of the scheme by Brunner and Simon [Phys. Rev. Lett. 105, 010405 (2010)] is proposed in order to show that quantum weak measurements can provide a method to detect ultrasmall longitudinal phase shifts, even with white light. By performing an analysis in the frequency domain, we find that the amplification effect will work as long as the spectrum is large enough, irrespective of the behavior in the time domain. As such, the previous scheme can be notably simplified for experimental implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasensitive search for long-lived superheavy nuclides in the mass range A=288 to A=300 in natural Pt, Pb, and Bi

Theoretical models of superheavy elements (SHEs) predict a region of increased stability around the proton and neutron shell closures of Z = 114 and N = 184. Therefore a sensitive search for nuclides in the mass range from A = 288 to A = 300 was performed in natural platinum, lead, and bismuth, covering long-lived isotopes of Eka-Pt (Ds, Z = 110), Eka-Pb (Z = 114), and Eka-Bi (Z = 115). Measurements with accelerator mass spectrometry (AMS) at the Vienna Environmental Research Accelerator (VERA) established upper limits for these SHE isotopes in Pt, Pb, and Bi with abundances of <2x10{sup -15}, <5x10{sup -14}, and <5x10{sup -13}, respectively. These results complement earlier searches for SHEs with AMS at VERA in natural thorium and gold, which now amounts to a total number of 37 SHE nuclides having been explored with AMS. In none of our measurements was evidence found for the existence of SHEs in nature at the reported sensitivity level. Even though a few events were observed in the window for {sup 293}Eka-Bi, a particularly strong pileup background did not allow a definite SHE isotope identification. The present result sets limits on nuclides around the center of the island of stability, essentially ruling out the existence of SHE nuclides with half-lives longer than {approx}150 million years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification

We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400{+-}200 frad and the linear travel of a piezo actuator down to 14{+-}7 fm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contorted acene ribbons for stable and ultrasensitive neural probes

Organic materials that conduct both electrons and ions are integral to implantable bioelectronics because of their conformable nature. There is a dearth of these materials that are highly sensitive to cations, which are the majority ions on the surface of neurons. This manuscript offers a solution using an extended ribbon structure that is defect-free, providing high electronic mobility along its fused backbone, while the edge structure of these ribbons promotes high ionic conductivity. We incorporated these mixed ion/electron conductors into neural probes and implanted them in a rodent brain where they offer a suite of useful properties: high cation sensitivity, stability over several weeks after implantation, and biocompatibility. These materials represent an innovative class of implantable biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functional Gene Array-Based Ultrasensitive and Quantitative Detection of Microbial Populations in Complex Communities

ABSTRACT While functional gene arrays (FGAs) have greatly expanded our understanding of complex microbial systems, specificity, sensitivity, and quantitation challenges remain. We developed a new generation of FGA, GeoChip 5.0, using the Agilent platform. Two formats were created, a smaller format (GeoChip 5.0S), primarily covering carbon-, nitrogen-, sulfur-, and phosphorus-cycling genes and others providing ecological services, and a larger format (GeoChip 5.0M) containing the functional categories involved in biogeochemical cycling of C, N, S, and P and various metals, stress response, microbial defense, electron transport, plant growth promotion, virulence, gyrB , and fungus-, protozoan-, and virus-specific genes. GeoChip 5.0M contains 161,961 oligonucleotide probes covering >365,000 genes of 1,447 gene families from broad, functionally divergent taxonomic groups, including bacteria (2,721 genera), archaea (101 genera), fungi (297 genera), protists (219 genera), and viruses (167 genera), mainly phages. Computational and experimental evaluation indicated that designed probes were highly specific and could detect as little as 0.05 ng of pure culture DNAs within a background of 1 μg community DNA (equivalent to 0.005% of the population). Additionally, strong quantitative linear relationships were observed between signal intensity and amount of pure genomic (∼99% of probes detected; r > 0.9) or soil (∼97%; r > 0.9) DNAs. Application of the GeoChip to a contaminated groundwater microbial community indicated that environmental contaminants (primarily heavy metals) had significant impacts on the biodiversity of the communities. This is the most comprehensive FGA to date, capable of directly linking microbial genes/populations to ecosystem functions. IMPORTANCE The rapid development of metagenomic technologies, including microarrays, over the past decade has greatly expanded our understanding of complex microbial systems. However, because of the ever-expanding number of novel microbial sequences discovered each year, developing a microarray that is representative of real microbial communities, is specific and sensitive, and provides quantitative information remains a challenge. The newly developed GeoChip 5.0 is the most comprehensive microarray available to date for examining the functional capabilities of microbial communities important to biogeochemistry, ecology, environmental sciences, and human health. The GeoChip 5 is highly specific, sensitive, and quantitative based on both computational and experimental assays. Use of the array on a contaminated groundwater sample provided novel insights on the impacts of environmental contaminants on groundwater microbial communities.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrasensitive measurement of microcantilever displacement below the shot-noise limit

The displacement of micro-electro-mechanical-systems (MEMs) cantilevers is used to measure a variety of phe- nomena in devices ranging from force microscopes for single spin detection[1] to biochemical sensors[2] to un- cooled thermal imaging systems[3]. The displacement readout is often performed optically with segmented de- tectors or interference measurements. Until recently, var- ious noise sources have limited the minimum detectable displacement in MEMs systems, but it is now possible to minimize all other sources[4] so that the noise level of the coherent light eld, called the shot noise limit (SNL), becomes the dominant source. Light sources dis- playing quantum-enhanced statistics below this limit are available[5, 6], with applications in gravitational wave astronomy[7] and bioimaging[8], but direct displacement measurements of MEMS cantilevers below the SNL have been impossible until now. Here, we demonstrate the rst direct measurement of a MEMs cantilever displace- ment with sub-SNL sensitivity, thus enabling ultratrace sensing, imaging, and microscopy applications. By com- bining multi-spatial-mode quantum light sources with a simple dierential measurement, we show that sub-SNL MEMs displacement sensitivity is highly accessible com- pared to previous eorts that measured the displacement of macroscopic mirrors with very distinct spatial struc- tures crafted with multiple optical parametric ampliers and locking loops[9]. We apply this technique to a com- mercially available microcantilever in order to detect dis- placements 60% below the SNL at frequencies where the microcantilever is shot-noise-limited. These results sup- port a new class of quantum MEMS sensor whose ulti- mate signal to noise ratio is determined by the correla- tions possible in quantum optics systems.

47 OTHER INSTRUMENTATION↗

Ultrasensitive, amplification-free assays for detecting pathogens

Hybridization of nucleic acid probes has the potential to directly detect pathogens without requiring resource-intensive amplification steps, but conventional approaches to direct hybridization are typically slow or suffer from low sensitivity. In this work, we have characterized a novel approach for rapid detection of low-abundance nucleic acids by direct hybridizati on in solution, with sensitive analysis enabled by electrophoretic preconcentration of nucleic acids at a nanoporous m embrane. We performed proof-of-concept testing of the assay using a m odel DNA virus, showing direct detection of as little as 400 amol (~240 m illion copies) with current (un optimized) hardware. We extensively char acterized the preconcentration process for DNA, and determ ined rates of preconcentrat ion and efficiency of recovery as a function of preconcentration conditions, membrane formulation, and DNA size. The membrane preconcentration device also en ables rapid, ultra-sensitive size-based separation of nucleic acids, and has been demonstrated for multiplex PCR analysis of drug resistance genes in bacteria.

Meagher, Robert J.↗

Ultrasensitive directional microphone arrays for military operations in urban terrain.

Acoustic sensing systems are critical elements in detection of sniper events. The microphones developed in this project enable unique sensing systems that benefit significantly from the enhanced sensitivity and extremely compact foot-print. Surface and bulk micromachining technologies developed at Sandia have allowed the design, fabrication and characterization of these unique sensors. We have demonstrated sensitivity that is only available in 1/2 inch to 1 inch studio reference microphones--with our devices that have only 1 to 2mm diameter membranes in a volume less than 1cm{sup 3}.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

P- and PN-Doped Nanotubes for Ultrasensitive and Selective Molecular Detection

A first-principles approach is used to establish that substitutional phosphorus atoms strongly modify the chemical properties of the surface of carbon nanotubes, creating highly-localized sites with specific affinity towards acceptor molecules. Phosphorus-nitrogen co-dopants have a similar effect for acceptor molecules, but the P-N bond can also accept charge, resulting in affinity towards donor molecules. This molecular selectivity is illustrated in CO and NH3 adsorbed on PN doped nanotubes, O2 on P-doped nanotubes, and NO2 and SO2 on both P- and PN-doped nanotubes. The adsorption of different chemical species onto the doped nanotubes modifies the dopant-induced localized states, which subsequently alter electronic conductance. Although SO2 and CO adsorption cause minor shifts in electronic conductance; NH3, NO2, and O2 adsorptions induce the suppression of a conductance dip. Conversely, the adsorption of NO2 on PN-doped nanotubes is accompanied with the appearance of an additional dip in conductance, correlated with a shift of the existing ones. Overall these changes in electric conductance provide an efficient way to detect selectively the presence of specific molecules. Additionally, the high oxidation potential of the P-doped nanotubes makes them good candidates for electrode materials in hydrogen fuel cells.

Cruz Silva, Eduardo↗

Ultrasensitive microanalytical diagnostic methods for rickettsial pathogens

A strategic CRADA was established between Sandia National Laboratories (SNL) and the University of Texas Medical Branch (UTMB) at Galveston to address pressing needs for US protection against biological weapons of mass destruction (WMD) and emerging infectious diseases. The combination of unique expertise and facilities at UTMB and SNL enabled interdisciplinary research efforts in the development of rapid and accurate diagnostic methods for early detection of trace priority pathogen levels. Outstanding postdoctoral students were also trained at both institutions to help enable the next generation of scientists to tackle the challenging interdisciplinary problems in the area of biodefense and emerging infectious diseases. Novel approaches to diagnostics were developed and the both the speed of assays as well as the detection sensitivity were improved by over an order of magnitude compared to traditional methods. This is a significant step toward more timely and specific detection of dangerous infections. We developed in situ polymerized porous polymer monoliths that can be used as (1) size exclusion elements for capture and processing of rickettsial infected cells from a sample, (2) photopatternable framework for grafting high densities of functionalized antibodies/fluorescent particles using novel monolith chemistry. Grafting affinity reagents specific to rickettsial particles enables rapid, ultra-sensitive assays by overcoming transport limitations of traditional planar assay approaches. We have selectively trapped particles and bacteria at the cell trap and have also detected picomolar mouse IL-6 captured with only 20 minutes total incubation times using the densely patterned monolith framework. As predicted, the monolith exhibits >10x improvements in both capture speed and capture density compared to traditional planar approaches. The most significant advancements as part of this CRADA is the optimization of techniques allowing the detection of <10 rickettsial cells in a whole blood sample. This detection limit is over 2 orders of magnitude more sensitive that previously reported methods and overcomes a key hurdle in ability to sense dangerous infections before they are too late to treat and contain. We also showed that in the new format, cross-reactivity with interfering species is reduced thereby increasing the specificity of such tests. Promising options to treat whole blood and avoid clogging and non-specific fouling of sensors were also developed.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Ultrasensitive biochemical sensing device and method of sensing analytes

Systems and methods biochemically sense a concentration of a ligand using a sensor having a substrate having a metallic nanoparticle array formed onto a surface of the substrate. A light source is incident on the surface. A matrix is deposited over the nanoparticle array and contains a protein adapted to binding the ligand. A detector detects s-polarized and p-polarized light from the reflective surface. Spacing of nanoparticles in the array and wavelength of light are selected such that plasmon resonance occurs with an isotropic point such that -s and -p polarizations of the incident light result in substantially identical surface Plasmon resonance, wherein binding of the ligand to the protein shifts the resonance such that differences between the -S and -P polarizations give in a signal indicative of presence of the ligand.

47 OTHER INSTRUMENTATION↗