Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transfer functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Neural Network‐Based Methods for Ocean Surface Wave Measurement Using Submarine Distributed Acoustic Sensing (DAS)

Two new data-driven models for estimating ocean surface waves from distributed acoustic sensing (DAS) submarine cable strain rate are developed using supervised machine learning on a 10-day data set collected offshore of Oliktok Point, Alaska. The new models were trained on target data from seafloor pressure moorings at three sites spaced evenly along 27.1 km of cable and were benchmarked against an empirical transfer function method previously used to estimate waves from DAS. A model which uses convolutional neural networks to transform 2-km frequency-wavenumber strain spectra to seafloor pressure spectra outperforms the benchmark in wave height prediction (RMSE of 0.15 vs. 0.41 m) and period prediction (0.29 vs. 0.37 s) when evaluated on a held-out test data set. When applied to a DAS data set collected on the same cable 2 years prior, the CNN-based model maintained similar significant wave height performance (RMSE = 0.23 m) relative to available satellite altimetry data. A two-hidden-layer, fully connected neural network which transforms 1-D strain spectra to seafloor pressure spectra also outperforms the benchmark in wave height prediction (RMSE of 0.19 vs. 0.41 m), but does not generalize as well to the prior data. Regression-based machine learning is useful for estimating waves from DAS data when the pressure-strain relationship varies temporally and spatially across different wave conditions. Models can be applied to DAS data to measure waves with higher spatial resolution and longer temporal coverage than traditional methods, which often measure waves only at a single point.

Davis, Jacob R. [Univ. of Washington, Seattle, WA ↗

2D perovskite-based high spatial resolution X-ray detectors

Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.

2D perovskite↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Local measurement of bulk thermal diffusivity using photothermal radiometry

Here, an experimental methodology using photothermal radiometry is developed for the accurate measurement of bulk thermal diffusivity of nuclear fuels and materials irradiated to high doses. Under these conditions, nuclear fuels, such as uranium oxide, and moderator materials, such as graphite, become friable, which requires characterization techniques that can accommodate irregularly shaped fragments. Photothermal radiometry, a good candidate for this application, involves locally heating a sample by using a laser and measuring the temperature field by monitoring blackbody radiation. The interaction volume for this study, less than a millimeter, is carefully chosen to sample a statistically significant number of large-scale structural features, such as pores and gas filled bubbles, and is small enough that the sample fragments can be treated as a thermal half-space. The thermal diffusivity standards considered in this study cover a range of thermal diffusivities representative of both fresh and spent nuclear fuels. We also consider a sample having a porous microstructure representative of large-scale structures found in materials irradiated to high doses. Our measurement methodology circumvents complex thermal wave models that address optical diffraction, nonlinear transfer function associated with blackbody radiation, and finite sample size effects. Consequently, the large measurement uncertainty associated with modeling these effects can be avoided. While the emphasis here is on nuclear fuels and materials, this measurement approach is well suited to measure thermal transport in a variety of technologically important materials associated with advanced synthesis techniques. Examples range from small, exotic single crystals grown using hydrothermal growth techniques to additively manufactured components having complex geometries.

36 MATERIALS SCIENCE↗

Characterization of a 1D-imaging high-energy x-ray backlighter driven by the National Ignition Facility Advanced Radiographic Capability laser

Plastic deformation of samples compressed to Mbar pressures at high strain rates at the National Ignition Facility (NIF) forms the basis of ongoing material strength experiments in conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Hard x-ray radiography is the primary means of measuring the evolution of these samples, typically employing a slit-collimated high-Z microdot driven by the NIF laser to generate >40 keV x rays [E. Gumbrell et al., Rev. Sci. Instrum. 89, 10G118 (2018) and C. M. Huntington et al., Rev. Sci. Instrum. 89, 10G121 (2018)]. Alternatively, a dysprosium “micro-flag” target driven by the Advanced Radiographic Capability laser (~2 kJ, 10 ps) can deliver significantly higher spatiotemporal resolution [M. P. Hill et al., Rev. Sci. Instrum. 92, 033535 (2021)], especially in high-opacity samples. Here, initial experiments revealed problematic brightness and spectral gradients from this source, but by radiographing a set of diamond-turned, 105 µm-thick Pb test objects and supported by simulations using the 3D Monte Carlo code GEANT4, these geometry-dependent gradients across the field of view are quantified and mitigation strategies are assessed. In addition to significantly enhancing the modulation transfer function compared to the existing system, image stacking from multiple layers of image plate is shown to almost double the signal to noise ratio that will reduce uncertainties in future dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

Single radio frequency bucket injection in the 88-Inch Cyclotron using a pulsed high voltage chopper

A single radio frequency bucket of the 88-Inch Cyclotron is filled using a fast chopper located in the axial line. The bucket then accelerates until it reaches the deflector, at which point, it is extracted as a train of bunches. This phenomenon can be attributed to the characteristic multi-turn extraction of the cyclotron and, by simplifying the complex dynamics of a cyclotron, corresponds to the conceptual transfer function of the cyclotron. In conclusion, the confirmation of the single radio frequency bucket injection was achieved by operating the cyclotron in the third harmonic mode and observing the absence of intermediate bunches during the multiple-bunch extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot in-line x-ray phase-contrast imaging of void-shockwave interactions in fusion energy materials

Recent breakthroughs in nuclear fusion, specifically the report of reactions exceeding scientific breakeven at the National Ignition Facility (NIF), highlight the potential of inertial fusion energy (IFE) as a sustainable and virtually limitless energy source. However, further progress in IFE requires characterization of defects in ablator materials and how they affect fuel capsule compression. Voids within the ablator can degrade energy yield, but their impact on the density distribution has primarily been studied through simulations, with limited high-resolution experimental validation. To address this, we used the x-ray free-electron laser (XFEL) at the matter in extreme conditions (MECs) instrument at the Linac coherent light source (LCLS) to capture 2D x-ray phase-contrast (XPC) images of a void-bearing sample with a composition similar to inertial confinement fusion (ICF) ablators. By driving a compressive shockwave through the sample using MEC's long-pulse laser system, we analyzed how voids influence shockwave propagation and density distribution during compression. To quantify this impact, we extracted phase information using two phase retrieval algorithms. First, we applied the contrast transfer function (CTF) method, paired with Tikhonov regularization and a fast optimization approach to generate an initial phase estimate. We then refined the result using a projected gradient descent (PGD) method that works directly with the sample's refractive index. Comparing these results with radiation adaptive grid Eulerian (xRAGE) radiation hydrodynamic simulations enables identification of model validation needs or improvements. By calculating phase maps in situ, it becomes possible to reconstruct areal density maps, improving understanding of laser-capsule interactions and advancing IFE research.

Hodge, D. S. [Colorado State Univ., Fort Collins, ↗

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

Nonlocal elastic metasurfaces: Enabling broadband wave control via intentional nonlocality

While elastic metasurfaces offer a remarkable and very effective approach to the subwavelength control of stress waves, their use in practical applications is severely hindered by intrinsically narrow band performance. In applications to electromagnetic and photonic metamaterials, some success in extending the operating dynamic range was obtained by using nonlocality. However, while electronic properties in natural materials can show significant nonlocal effects, even at the macroscales, in mechanics, nonlocality is a higher-order effect that becomes appreciable only at the microscales. This study introduces the concept of intentional nonlocality as a fundamental mechanism to design passive elastic metasurfaces capable of an exceptionally broadband operating range. The nonlocal behavior is achieved by exploiting nonlocal forces, conceptually akin to long-range interactions in nonlocal material microstructures, between subsets of resonant unit cells forming the metasurface. These long-range forces are obtained via carefully crafted flexible elements, whose specific geometry and local dynamics are designed to create remarkably complex transfer functions between multiple units. The resulting nonlocal coupling forces enable achieving phase-gradient profiles that are functions of the wavenumber of the incident wave. The identification of relevant design parameters and the assessment of their impact on performance are explored via a combination of semianalytical and numerical models. The nonlocal metasurface concept is tested, both numerically and experimentally, by embedding a total-internal-reflection design in a thin-plate waveguide. Results confirm the feasibility of the intentionally nonlocal design concept and its ability to achieve a fully passive and broadband wave control.

36 MATERIALS SCIENCE↗

Improving initialization and evolution accuracy of cosmological neutrino simulations

Neutrino mass constraints are a primary focus of current and future large-scale structure (LSS) surveys. Non-linear LSS models rely heavily on cosmological simulations — the impact of massive neutrinos should therefore be included in these simulations in a realistic, computationally tractable, and controlled manner. Here, a recent proposal to reduce the related computational cost employs a symmetric neutrino momentum sampling strategy in the initial conditions. We implement a modified version of this strategy into the Hardware/Hybrid Accelerated Cosmology Code (HACC) and perform convergence tests on its internal parameters. We illustrate that this method can impart Script $\mathcal{O}$(1%) numerical artifacts on the total matter field on small scales, similar to previous findings, and present a method to remove these artifacts using Fourier-space filtering of the neutrino density field. Moreover, we show that the converged neutrino power spectrum does not follow linear theory predictions on relatively large scales at early times at the 15% level, prompting a more careful study of systematics in particle-based neutrino simulations. We also present an improved method for backscaling linear transfer functions for initial conditions in massive neutrino cosmologies that is based on achieving the same relative neutrino growth as computed with Boltzmann solvers. Our self-consistent backscaling method yields sub-percent accuracy in the total matter growth function. Comparisons for the non-linear power spectrum with the Mira-Titan emulator at a neutrino mass of m ν = 0.15 eV are in very good agreement with the expected level of errors in the emulator and in the direct N-body simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular momentum of vacuum bubbles in a first-order phase transition

The formation of primordial black holes (PBHs) during a first-order phase transition (FOPT) in a dark sector has been of recent interest. A quantity that characterizes a black hole is its spin. We carry out the first step towards determining the spin of such PBHs, by calculating the spin of spherical false vacuum bubbles induced by cosmological perturbations. The angular momentum is given by the product of density and velocity perturbations. We carefully track the evolution of background quantities and calculate the transfer functions during the FOPT. We find that the dimensionless spin parameter s = J /(G N M 2 ) of false vacuum bubbles of mass M and angular momentum J , take a wide range of values from 𝒪(10 -5 ) to 𝒪(10) for FOPTs between 10 keV and 100 GeV and a dark sector that is 0.1 to 0.4 times cooler than the visible sector. We also find a scaling relation between the root-mean-square value of the spin, the FOPT time scale, the bubble wall velocity, and the dark sector-to-visible sector temperature ratio.

cosmological phase transitions↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗

$\rm {H\,\small {I}}$ constraints from the cross-correlation of eBOSS galaxies and Green Bank Telescope intensity maps

We present the joint analysis of Neutral Hydrogen ($\rm {H\,\small {I}}$) Intensity Mapping observations with three galaxy samples: the Luminous Red Galaxy (LRG) and Emission Line Galaxy (ELG) samples from the eBOSS survey, and the WiggleZ Dark Energy Survey sample. The $\rm {H\,\small {I}}$ intensity maps are Green Bank Telescope observations of the redshifted $21\rm cm$ emission on $100 \, {\rm deg}^2$ covering the redshift range 0.6 < z < 1.0. We process the data by separating and removing the foregrounds present in the radio frequencies with FastI ICA. We verify the quality of the foreground separation with mock realizations, and construct a transfer function to correct for the effects of foreground removal on the $\rm {H\,\small {I}}$ signal. We cross-correlate the cleaned $\rm {H\,\small {I}}$ data with the galaxy samples and study the overall amplitude as well as the scale dependence of the power spectrum. We also qualitatively compare our findings with the predictions by a semianalytical galaxy evolution simulation. The cross-correlations constrain the quantity $\Omega _{\rm {H\,\small {I}}} b_{\rm {H\,\small {I}}} r_{\rm {H\,\small {I}},{\rm opt}}$ at an effective scale k eff , where $\Omega _\rm {H\,\small {I}}$ is the $\rm {H\,\small {I}}$ density fraction, $b_\rm {H\,\small {I}}$ is the $\rm {H\,\small {I}}$ bias, and $r_{\rm {H\,\small {I}},{\rm opt}}$ the galaxy–hydrogen correlation coefficient, which is dependent on the $\rm {H\,\small {I}}$ content of the optical galaxy sample. At $k_{\rm eff}=0.31 \, h\,{\rm Mpc^{-1}}$ we find $\Omega _{\rm {H\,\small {I}}} b_{\rm {H\,\small {I}}} r_{\rm {H\,\small {I}},{\rm Wig}} = [0.58 \pm 0.09 \, {\rm (stat) \pm 0.05 \, {\rm (sys)}}] \times 10^{-3}$ for GBT-WiggleZ, $\Omega _{\rm {H\,\small {I}}} b_{\rm {H\,\small {I}}} r_{\rm {H\,\small {I}},{\rm ELG}} = [0.40 \pm 0.09 \, {\rm (stat) \pm 0.04 \, {\rm (sys)}}] \times 10^{-3}$ for GBT-ELG, and $\Omega _{\rm {H\,\small {I}}} b_{\rm {H\,\small {I}}} r_{\rm {H\,\small {I}},{\rm LRG}} = [0.35 \pm 0.08 \, {\rm (stat) \pm 0.03 \, {\rm (sys)}}] \times 10^{-3}$ for GBT-LRG, at z ≃ 0.8. We also report results at $k_{\rm eff}=0.24$ and $k_{\rm eff}=0.48 \, h\,{\rm Mpc^{-1}}$. With little information on $\rm {H\,\small {I}}$ parameters beyond our local Universe, these are amongst the most precise constraints on neutral hydrogen density fluctuations in an underexplored redshift range.

79 ASTRONOMY AND ASTROPHYSICS↗

Accurate effective fluid approximation for ultralight axions

Ultralight axions are theoretically interesting and phenomenologically rich dark sector candidates, but they are difficult to track across cosmological timescales because of their fast oscillations. We resolve this problem by developing a novel method to evolve them efficiently and accurately. We first construct an exact effective fluid which at late times matches the axion but which evolves in a simple way. We then approximate this evolution with a carefully chosen equation of state and sound speed. With our scheme we find that we can obtain subpercent accuracy for the linear theory suppression of axion density fluctuations relative to that of cold dark matter without tracking even a single complete oscillation of the axion field. Furthermore, we use our technique to test other approximation schemes and to provide a fitting formula for the transfer function for the matter power spectrum in linear theory in axion models. Implementing our approach in existing cosmological axion codes is straightforward and will help unleash the potential of high-precision next-generation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmic structure strikes back: The elimination of vector-mediated nonstandard interaction models as a mechanism for sterile neutrino dark matter production

We revisit sterile neutrino production enabled by nonstandard interactions (NSIs) among active neutrinos mediated by new bosons. We focus on vector mediators, including neutrinophilic, gauged 𝐿 𝜇 −𝐿 𝜏 , and 𝐵−𝐿 realizations, that modify in-medium dispersion and scattering, thereby altering the active-sterile conversion history. Building on a novel production framework with NSI thermal potentials and collision integrals, we compute nonthermal phase-space distributions across sterile neutrino mixing and NSI parameters and map each point to an equivalent thermal warm dark matter particle mass 𝑚 th via linear theory transfer function fitting with the cosmological structure formation Boltzmann solver. This enables a direct reinterpretation of state-of-the-art structure formation limits from Milky Way satellites, strong lensing, and the Lyman-𝛼 forest. These limits, in conjunction with x-ray decay searches, as well as results from a wide variety of particle physics experiments allow for a more complete examination of these models. We find that these vector-mediated models are ruled out when the full combination of current constraints, listed above, are taken into account. NSI scalar-mediated models and models with low reheating temperatures remain viable.

cosmology↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗