Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermal Performance of Low Layer Density Multilayer Insu1ation Using Liquid Nitrogen

In order to support long duration cryogenic propellant storage, the Cryogenic Fluid Management (CFM) Project of the Exploration Technology Development Program (ETDP) is investigating the long duration storage propertie$ of liquid methane on the lunar surface. The Methane Lunar Surface Thermal Control (MLSTC) testing is using a tank of the approximate dimensions of the Altair ascent tanks inside of a vacuum chamber to simulate the environment in low earth orbit and on the lunar surface. The thermal performance testing of multilayer insulation (MLI) coupons that are fabricated identically to the tank applied insulation is necessary to understand the performance of the blankets and to be able to predict the performance of the insulation prior to testing. This coupon testing was completed in Cryostat-100 at the Cryogenics Test Laboratory. The results showed the properties of the insulation as a function of layer density, number of layers, and warm boundary temperature. These results aid in the understanding of the performance parameters o fMLI and help to complete the body of literature on the topic.

Johnson, Wesley L.↗

Thermal Performance of LANDSAT-7 ETM+ Instruments During First Year in Flight

Landsat-7 was successfully launched into orbit on April 15, 1999. After devoting three months to the t bakeout and cool-down of the radiative cooler, and on- t orbit checkout, the Enhanced Thematic Mapper Plus (ETM+) began the normal imaging phase of the mission in mid-July 1999. This paper presents the thermal performance of the ETM+ from mid-July 1999 to mid-May 2000. The flight temperatures are compared to the yellow temperature limits, and worst cold case and worst hot case flight temperature predictions in the 15-orbit mission design profile. The flight temperature predictions were generated by a thermal model, which was correlated to the observatory thermal balance test data. The yellow temperature limits were derived from the flight temperature predictions, plus some margins. The yellow limits work well in flight, so that only several minor changes to them were needed. Overall, the flight temperatures and flight temperature predictions have good agreement. Based on the ETM+ thermal vacuum qualification test, new limits on the imaging time are proposed to increase the average duty cycle, and to resolve the problems experienced by the Mission Operation Team.

Choi, Michael K.↗

In-Flight Thermal Performance of the OCO-2 Instrument

The Orbiting Carbon Observatory-2 (OCO-2), launched on July 2, 2014, continues to operate nominally after successfully completing its primary mission of two years in space. It is hoped that, following a Senior Review and proposal phase, NASA will fund a two year extended mission, which would start in June 2017. The thermal design provides three temperature zones required by the instrument, specifically at 120 K, 267 K and 297 K. A single-stage pulse tube cryocooler provides refrigeration to three focal plane arrays to 120 K, via a high conductance flexible thermal strap. A variable conductance heat pipe (VCHP) based heat rejection system transports waste heat from the instrument, located inside the spacecraft, to the space-viewing radiators, providing tight temperature control of the spectrometer optics to 267 K, and maintains the electronics and cryocooler at 297 K. Soon after entering the A-Train on August 3, 2014, the optics and focal planes were cooled to their operating temperatures. Ice contamination of the cryogenic surfaces led to increased cryocooler loads and drove the need for two focal plane decontamination cycles between September 2014 and October 2014. A decrease in the radiometric gain of the O2 A-Band channel led to five additional focal plane decontamination cycles, between January 2015 and February 2017, and is now the primary driver of decontamination cycles. This paper provides a general overview of the thermal and cryogenic system design and reviews the inflight thermal performance for the mission.

Na-Nakornpanom, Arthur↗

Thermal Performance of the XRS Helium Insert

The X-Ray Spectrometer (XRS) is an instrument on the Japanese Astro-E satellite, scheduled for launch early in the year 2000. The XRS Helium Insert comprises a superfluid helium cryostat, an Adiabatic Demagnetization Refrigerator (ADR), and the XRS calorimeters with their cold electronics. The calorimeters are capable of detecting X-rays over the energy range 0.1 to 10 keV with a resolution of 12 eV. The Helium Insert completed its performance and verification testing at Goddard in January 1999. It was shipped to Japan, where it has been integrated with the neon dewar built by Sumitomo Heavy Industries. The Helium Insert was given a challenging lifetime requirement of 2.0 years with a goal of 2.5 years. Based on the results of the thermal performance tests, the predicted on-orbit lifetime is 2.6 years with a margin of 30%. This is the result of both higher efficiency in the ADR cycle and the low temperature top-off, more than compensating for an increase in the parasitic heat load. This paper presents a summary of the key design features and the results of the thermal testing of the XRS Helium Insert.

Breon, Susan R.↗

Indoor test and long-term weathering effects on the thermal performance of the solar energy system (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on a liquid solar collector are presented. The narrow flat plate collector with reflective concentrating mirrors uses water as the working fluid. The double-covered collector weighs 137 pounds and has overall dimensions of about 35" by 77" by 6.75". The test program was conducted to obtain the following information: thermal performance data under simulated conditions, structural behavior under static load, and the effects of long term exposure to natural weathering.

Source record↗

Thermal performance trade-offs for point focusing solar collectors

Solar thermal conversion performance is assessed in this paper for representative point focusing distributed systems. Trade-off comparisons are made in terms of concentrator quality, solar receiver operating temperature, and power conversion efficiency. Normalized system performance is presented on a unit concentrator area basis for integrated annual electric energy production.

Wen, L.↗

Thermal performance evaluation of the Calmac (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the S. N. 1, (liquid) solar collector are presented. The flat plate collector uses water as the working fluid. The absorber plate is aluminum with plastic tubes coated with urethane black. The glazing consists of .040 in fiberglass reinforced polyester. The collector weight is 78.5 pounds with overall external dimensions of approximately 50.3in. x 98.3in. x 3.8in. The following information is given: thermal performance data under simulated conditions, structural behavior under static loading, and the effects of long term exposure to natural weathering. These tests were conducted using the MSFC Solar Simulator.

Usher, H.↗

Thermal Performance of Common Bulk-Fill Cryogenic Insulation Materials in Helium and Hydrogen Background Gases

Maritime shipping of vast quantities of liquid hydrogen (LH 2 ) will be necessary to facilitate a global hydrogen ecosystem; with some studies estimating volumes up to 172,000 m 3 for individual tanker ships, and requiring stationary storage tanks at terminals of 50,000 m 3 to 100,000 m 3 —ten to fifteen times larger than the current largest tank, located at launch pad B at NASA Kennedy Space Center (KSC). Such a radical scale-up will push the boundary of traditional, vacuum-insulated tank designs. Hence, a potential need exists for non-vacuum solutions, which necessitates exploring the thermal performance of insulation materials in non-condensable background gasses at LH 2 temperatures, namely helium and hydrogen. Testing of two bulk-fill insulation materials common to large LH 2 storage tanks, perlite and glass bubbles, in helium and hydrogen was recently conducted by the Cryogenics Test Laboratory at KSC using the Cryostat-100 liquid nitrogen boiloff calorimeter per the ASTM C1774 standard methodology. Effective thermal conductivity (k e ) and heat flux (q) results for each insulation/gas combination are presented across the full vacuum range, as well as thermal profiles through the insulation thickness between 78 K and 293 K.

A M Swanger↗

Thermal performance evaluation of the Semco (liquid) solar collector

Procedures used and results obtained during the evaluation test program on a flat plate collector which uses water as the working fluid are discussed. The absorber plate is copper tube soldered to copper fin coated with flat black paint. The glazing consists of two plates of Lo-Iron glass; the insulation is polyurethane foam. The collector weight is 242.5 pounds with overall external dimensions of approximately 48.8 in. x 120.8 in. x 4.1 in. The test program was conducted to obtain thermal performance data before and after 34 days of weather exposure test.

Source record↗

Mars Exploration Rover surface mission flight thermal performance

NASA launched two rovers in June and July of 2003 as a part of the Mars Exploration Rover (MER) project. MER-A (Spirit) landed on Mars in Gusev Crater at 15 degrees South latitude and 175 degree East longitude on January 4, 2004 (Squyres, et al., Dec. 2004)). MER-B (Opportunity) landed on Mars in Terra Meridiani at 2 degrees South latitude and 354 degrees East longitude on January 25, 2004 (Squyres, et al., August 2004) Both rovers have well exceeded their design lifetime (90 Sols) by more than a factor of 4. Spirit and Opportunity are still healthy and continue to execute their roving science missions at the time of this writing. This paper discusses rover flight thermal performance during the surface missions of both vehicles, covering roughly the time from the MER-A landing in late Southern Summer (Ls = 328, Sol 1A) through the Southern Winter solstice (Ls = 90, Sol 255A) to nearly Southern Vernal equinox (Ls = 160 , Sol 398A).

thermal design↗

In-Flight Thermal Performance of the Geoscience Laser Altimeter System (GLAS) Instrument

The Geoscience Laser Altimeter System (GLAS) instrument is NASA Goddard Space Flight Center's first application of Loop Heat Pipe technology that provides selectable/stable temperature levels for the lasers and other electronics over a widely varying mission environment. GLAS was successfully launched as the sole science instrument aboard the Ice, Clouds, and Land Elevation Satellite (ICESat) from Vandenberg AFB at 4:45pm PST on January 12, 2003. After SC commissioning, the LHPs started easily and have provided selectable and stable temperatures for the lasers and other electronics. This paper discusses the thermal development background and testing, along with details of early flight thermal performance data.

Grob, Eric↗

Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

Source record↗

Thermal Performance of Aged and Weathered Spray-On Foam Insulation (SOFI) Materials Under Cryogenic Vacuum Conditions (Cryostat-4)

The NASA Cryogenics Test Laboratory at Kennedy Space Center conducted long-term testing of SOFI materials under actual-use cryogenic conditions with Cryostat-4. The materials included in the testing were NCFI 24-124 (acreage foam), BX-265 (close-out foam, including intertank flange and bipod areas), and a potential alternate material, NCFI 27-68, (acreage foam with the flame retardant removed). Specimens of these materials were placed at two locations: a site that simulated aging (the Vehicle Assembly Building [VAB]) and a site that simulated weathering (the Atmospheric Exposure Test Site [beach site]). After aging/weathering intervals of 3, 6, and 12 months, the samples were retrieved and tested for their thermal performance under cryogenic vacuum conditions with test apparatus Cryostat-4.

Source record↗

Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft

The Terra spacecraft is the flagship of NASA's Earth Science Enterprise. It provides global data on the state of atmosphere, land and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport System (CPHTS) for temperature control: Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.

Ku, Jentung↗

Design and Preliminary Thermal Performance of the Mars Science Laboratory Rover Heat Exchangers

The challenging range of proposed landing sites for the Mars Science Laboratory Rover requires a rover thermal management system that is capable of keeping temperatures controlled across a wide variety of environmental conditions. On the Martian surface where temperatures can be as cold as -123 degrees Centigrade and as warm as 38 degrees Centigrade, the Rover relies upon a Mechanically Pumped Fluid Loop (MPFL) and external radiators to maintain the temperature of sensitive electronics and science instruments within a -40 degrees Centigrade to 50 degrees Centigrade range. The MPFL also manages significant waste heat generated from the Rover power source, known as the Multi Mission Radioisotope Thermoelectric Generator (MMRTG). The MMRTG produces 110 Watts of electrical power while generating waste heat equivalent to approximately 2000 Watts. Two similar Heat Exchanger (HX) assemblies were designed to both acquire the heat from the MMRTG and radiate waste heat from the onboard electronics to the surrounding Martian environment. Heat acquisition is accomplished on the interior surface of each HX while heat rejection is accomplished on the exterior surface of each HX. Since these two surfaces need to be at very different temperatures in order for the MPFL to perform efficiently, they need to be thermally isolated from one another. The HXs were therefore designed for high in-plane thermal conductivity and extremely low through-thickness thermal conductivity by using aerogel as an insulator inside composite honeycomb sandwich panels. A complex assembly of hand welded and uniquely bent aluminum tubes are bonded onto the HX panels and were specifically designed to be easily mated and demated to the rest of the Rover Heat Recovery and Rejection System (RHRS) in order to ease the integration effort. During the cruise phase to Mars, the HX assemblies serve the additional function of transferring heat from the Rover MPFL to the separate Cruise Stage MPFL so that heat generated deep inside the Rover can be dissipated via the Cruise Stage radiators. Significant fabrication challenges had to be overcome in order to make the HX design a reality. The cruise phase thermal performance of the Rover HXs was verified in the cruise phase system level thermal vacuum test that was performed at JPL in January of 2009. The Rover HXs were modeled in I-DEAS TMG and predictions are compared to actual data from the test.

Heat Rejection System↗

The Submillimeter-Wave Astronomy Satellite: On-Orbit Thermal Performance and Design Retrospective

A large telescope aperture, stringent thermal stability and temperature range requirements, and a passively-cooled 1500K module presented major challenges in thermal design and hardware fabrication of this Small Explorer satellite. This paper reviews briefly the thermal design of the SWAS science instrument, and examines the first three months of on-orbit thermal history. Measured temperatures for both the science payload and the spacecraft module and solar arrays are compared with those predicted by the correlated analytical model. Similarities and differences are interpreted in terms of the major uncertainties remaining after thermal-balance testing, especially those of MLI performance and telescope aperture properties. Review of the thermal model adequacy and thermal design verification are included to suggest improvements in the thermal design process for future missions.

Boyd, David A.↗

The Submillimeter-Wave Astronomy Satellite: On-Orbit Thermal Performance and Design Retrospective

A large telescope aperture, stringent thermal stability and temperature range requirements, and a passively-cooled 150 K module presented major challenges in thermal design and hardware fabrication of this Small Explorer satellite. This paper reviews briefly the thermal design of the SWAS science instrument, and examines the first three months of on-orbit thermal history. Measured temperatures for both the science payload and the spacecraft module and solar arrays are compared with those predicted by the correlated analytical model. Similarities and differences are interpreted in terms of the major uncertainties remaining after thermal-balance testing, especially those of MLI performance and telescope aperture properties. Review of the thermal model adequacy and thermal design verification are included to suggest improvements in the thermal design process for future missions.

Boyd, David A.↗

On-Orbit Thermal Performance of a Submillimeter Telescope Primary Reflector Panel

A detailed thermal analysis has been performed for a panel of a segmented primary mirror which is closest to the high side of the telescope sunshade. This panel was selected because the spatial temperature distribution was expected to be the worst. The JPL90-10 primary reflector panel configuration was investigated because of its superior figure error performance in ground-based testing.

SMILS↗