Life support and internal thermal control system design for the Space Station Freedom

A Review of the Space Station Freedom Environmental Control and Life Support System (ECLSS) as well as the Internal Thermal Control System (ITCS) design, including recent changes resulting from an activity to restructure the program, is provided. The development state of the original Space Station Freedom ECLSS through the restructured configuration is considered and the selection of regenerative subsystems for oxygen and water reclamation is addressed. A survey of the present ground development and verification program is given.

Humphries, R.↗

An Analysis of an Automatic Coolant Bypass in the International Space Station Node 2 Internal Active Thermal Control System

A challenging part of International Space Station (ISS) thermal control design is the ability to incorporate design changes into an integrated system without negatively impacting performance. The challenge presents itself in that the typical ISS Internal Active Thermal Control System (IATCS) consists of an integrated hardware/software system that provides active coolant resources to a variety of users. Software algorithms control the IATCS to specific temperatures, flow rates, and pressure differentials in order to meet the user-defined requirements. What may seem to be small design changes imposed on the system may in fact result in system instability or the temporary inability to meet user requirements. The purpose of this paper is to provide a brief description of the solution process and analyses used to implement one such design change that required the incorporation of an automatic coolant bypass in the ISS Node 2 element.

Clanton, Stephen E.↗

Verification of an analytic modeler for capillary pump loop thermal control systems

A number of computer programs have been written to model two-phase heat transfer systems for space use. These programs support the design of thermal control systems and provide a method of predicting their performance in the wide range of thermal environments of space. Predicting the performance of one such system known as the capillary pump loop (CPL) is the intent of the CPL Modeler. By modeling two developed CPL systems and comparing the results with actual test data, the CPL Modeler has proven useful in simulating CPL operation. Results of the modeling effort are discussed, together with plans for refinements to the modeler.

Schweickart, R. B.↗

International Space Station Internal Thermal Control System Lab Module Simulator Build-Up and Validation

As part of the Sustaining Engineering program for the International Space Station (ISS), a ground simulator of the Internal Thermal Control System (ITCS) in the Lab Module was designed and built at the Marshall Space Flight Center (MSFC). To support prediction and troubleshooting, this facility is operationally and functionally similar to the flight system and flight-like components were used when available. Flight software algorithms, implemented using the LabVIEW(Registered Trademark) programming language, were used for monitoring performance and controlling operation. Validation testing of the low temperature loop was completed prior to activation of the Lab module in 2001. Assembly of the moderate temperature loop was completed in 2002 and validated in 2003. The facility has been used to address flight issues with the ITCS, successfully demonstrating the ability to add silver biocide and to adjust the pH of the coolant. Upon validation of the entire facility, it will be capable not only of checking procedures, but also of evaluating payload timelining, operational modifications, physical modifications, and other aspects affecting the thermal control system.

Paul Wieland↗

Overview of the Altair Lunar Lander Thermal Control System Design

NASA's Constellation Program has been developed to successfully return humans to the Lunar surface by 2020. The Constellation Program includes several different project offices including Altair, which is the next generation Lunar Lander. The planned Altair missions are very different than the Lunar missions accomplished during the Apollo era. These differences have resulted in a significantly different thermal control system architecture. The current paper will summarize the Altair mission architecture and the various operational phases. In addition, the derived thermal requirements will be presented. The paper will conclude with a brief description of the thermal control system designed to meet these unique and challenging thermal requirements.

Stephan, Ryan A.↗

Space station freedom resource nodes internal thermal control system

This paper presents an overview of the design and operation of the internal thermal control system (ITCS) developed for Space Station Freedom by the NASA-Johnson Space Center and McDonnell Douglas Aerospace to provide cooling for the resource nodes, airlock, and pressurized logistics modules. The ITCS collects, transports and rejects waste heat from these modules by a dual-loop, single-phase water cooling system. ITCS performance, cooling, and flow rate requirements are presented. An ITCS fluid schematic is shown and an overview of the current baseline system design and its operation is presented. Assembly sequence of the ITCS is explained as its configuration develops from Man Tended Capability (MTC), for which node 2 alone is cooled, to Permanently Manned Capability (PMC) where the airlock, a pressurized logistics module, and node 1 are cooled, in addition to node 2. A SINDA/FLUINT math model of the ITCS is described, and results of analyses for an MTC and a PMC case are shown and discussed.

Merhoff, Paul↗

Assessment of Microbiologically Influenced Corrosion Potential in the International Space Station Internal Active Thermal Control System Heat Exchanger Materials: A 6-Momths Study

The fluid in the Internal Active Thermal Control System (IATCS) of the International Space Station (ISS) is water based. The fluid in the ISS Laboratory Module and Node 1 initially contained a mix of water, phosphate (corrosion control), borate (pH buffer), and silver sulfate (Ag2SO4) (microbial control) at a pH of 9.5+/-0.5. Over time, the chemistry of the fluid changed. Fluid changes included a pH drop from 9.5 to 8.3 due to diffusion of carbon dioxide (CO2) through Teflon(reistered Trademark) (DuPont) hoses, increases in dissolved nickel (Ni) levels, deposition of silver (Ag) to metal surfaces, and precipitation of the phosphate (PO4) as nickel phosphate (NiPO4). The drop in pH and unavailability of a antimicrobial has provided an environment conducive to microbial growth. Microbial levels in the fluid have increased from >10 colony-forming units (CFUs)/100 ml to 10(exp 6) CFUs/100 ml. The heat exchangers in the IATCS loops are considered the weakest point in the loop because of the material thickness (=7 mil). It is made of a Ni-based braze filler/CRES 347. Results of a preliminary test performed at Hamilton Sundstrand indicated the possibility of pitting on this material at locations where Ag deposits were found. Later, tests have confirmed that chemical corrosion of the materials is a concern for this system. Accumulation of micro-organisms on surfaces (biofilm) can also result in material degradation and can amplify the damage caused by the chemical corrosion, known as microbiologically influenced corrosion (MIC). This paper will discuss the results of a 6-mo test performed to characterize and quantify the damage from microbial accumulation on the surface of the ISS/ATCS heat exchanger materials. The test was designed to quantify the damage to the materials under worst-case conditions with and without micro-organisms present at pH 8.3 and 9.5.

Roman, Monsi C.↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit of the ammonia leak were the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Thermal Control↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool the majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit for the ammonia leak was the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Thermal Control↗

Internal Active Thermal Control System (IATCS) Sodium Bicarbonate/Carbonate Buffer in an Open Aqueous Carbon Dioxide System and Corollary Electrochemical/Chemical Reactions Relative to System pH Changes

The International Space Station (ISS) Internal Active Thermal Control System (IATCS) experienced a number of chemical changes driven by system absorption of CO2 which altered the coolant’s pH. The natural effects of the decrease in pH from approximately 9.2 to less than 8.4 had immediate consequences on system corrosion rates and corrosion product interactions with specified coolant constituents. The alkalinity of the system was increased through the development and implementation of a carbonate/bicarbonate buffer that would increase coolant pH to 9.0 – 10.0 and maintain pH above 9.0 in the presence of ISS cabin concentrations of CO2 up to twenty times higher than ground concentrations. This paper defines how a carbonate/bicarbonate buffer works in an open carbon dioxide system and summarizes the analyses performed on the buffer for safe and effective application in the on-orbit system. The importance of the relationship between the cabin environment and the IATCS is demonstrated as the dominant factor in understanding the system chemistry and pH trends before and after addition of the carbonate/bicarbonate buffer. The paper also documents the corollary electrochemical and chemical reactions the system has experienced and the rationale for remediation of these effects with the addition of the carbonate/bicarbonate buffer.

Stegman, Thomas W.↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high-definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit of the ammonia leak were the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Darnell Cowan↗

Shuttle active thermal control system development testing. Volume 1: Overall summary

A summary is given of a series of thermal vacuum tests designed to support the development of the orbiter active thermal control system (ATCS) and included testing of a wide heat load range modular radiator system (MRS) configured to the March 1973 orbiter baseline system, a candidate weight reducing radiator/water cooling system, and a smaller radiator system with a high performance radiator coating. The tests verified the performance of the baseline system and obtained detailed design information for application of a wide heat load range modular radiator system to the orbiter. The two candidate ATCS weight reducing designs have undergone extensive concept verification testing and their system operating characteristics have been determined in sufficient detail for application to the orbiter. Design information has been obtained for an integrated radiator/water cooling system that provides for vehicle heat rejection as well as water management of the excess fuel cell water. Processing techniques have been developed and verified for the application of a high performance thermal control coating to large radiator areas subjected to a temperature range of -280 F to +160 F.

Howell, H. R.↗

Study of plate-fin heat exchanger and cold plate for the active thermal control system of Space Station

Plate-fin heat exchangers will be employed in the Active Thermal Control System of Space Station Freedom. During ground testing of prototypic heat exchangers, certain anomalous behaviors have been observed. Diagnosis has been conducted to determine the cause of the observed behaviors, including a scrutiny of temperature, pressure, and flow rate test data, and verification calculations based on such data and more data collected during the ambient and thermal/vacuum tests participated by the author. The test data of a plate-fin cold plate have been also analyzed. Recommendation was made with regard to further tests providing more useful information of the cold plate performance.

Chyu, MING-C.↗

(abstract) Mars Pathfinder Active Thermal Control System: Ground and Flight Performance of a Mechanically Pumped Cooling Loop

A key element of the Mars Pathfinder thermal control system is the Heat Rejection System (HRS). The HRS of Mars Pathfinder is designed to actively control the temperatures of the various parts of the spacecraft.This is achieved by mechanically circulating single-phase Freon 11 liquid through the lander and cruise electronics box heat exchangers and transferring the heat to an external radiator on the cruise stage. This is the first time in spacecraft history that a mechanically pumped cooling loop has been used on a long duration spacecraft mission. Many lessons have been learned during the testing and ground and flight operation of the HRS. This paper will present the performance of the mechanically pumped cooling loop during the ground and flight operations. Based on the lessons learned from this experience, recommendations on the design and operation of the pumped cooling loops for future space missions will be made.

Mars↗

Orion Active Thermal Control System Dynamic Modeling Using Simulink/MATLAB

This paper presents dynamic modeling of the crew exploration vehicle (Orion) active thermal control system (ATCS) using Simulink (Simulink, developed by The MathWorks). The model includes major components in ATCS, such as heat exchangers and radiator panels. The mathematical models of the heat exchanger and radiator are described first. Four different orbits were used to validate the radiator model. The current model results were compared with an independent Thermal Desktop (TD) (Thermal Desktop, PC/CAD-based thermal model builder, developed in Cullimore & Ring (C&R) Technologies) model results and showed good agreement for all orbits. In addition, the Orion ATCS performance was presented for three orbits and the current model results were compared with three sets of solutions- FloCAD (FloCAD, PC/CAD-based thermal/fluid model builder, developed in C&R Technologies) model results, SINDA/FLUINT (SINDA/FLUINT, a generalized thermal/fluid network-style solver ) model results, and independent Simulink model results. For each case, the fluid temperatures at every component on both the crew module and service module sides were plotted and compared. The overall agreement is reasonable for all orbits, with similar behavior and trends for the system. Some discrepancies exist because the control algorithm might vary from model to model. Finally, the ATCS performance for a 45-hr nominal mission timeline was simulated to demonstrate the capability of the model. The results show that the ATCS performs as expected and approximately 2.3 lb water was consumed in the sublimator within the 45 hr timeline before Orion docked at the International Space Station.

Wang, Xiao-Yen J.↗

Thermal Control System Architecture and Technology Challenges for a Lunar Surface Habitat

NASA’s current plans for exploration of the Lunar South Pole region include a Surface Habitat (SH) to provide up to 60-day habitability for a crew of four. The SH concept is comprised of several elements including an inflatable volume for the habitable space and a metallic airlock for access to a pressurized rover and other surface assets. A conceptual architecture for the SH Thermal Control System (TCS) is presented. A TCS dual loop design is utilized with a water/propylene glycol mix for the internal crew spaces and an external loop with low temperature coolant. The internal loop is partitioned into low and moderate temperature service with a sublimator available for operational scenarios prior to thermal radiator deployment (or redeployment). Waste heat is rejected through thermal radiators contained in the external loop. Optimization of the thermal radiator geometry/orientation as well as the TCS internal/external loop architecture is accomplished via analytical models of the system. Low mass, dust tolerant, deployable/retractable thermal radiators (in partial gravity) and thermal control surfaces, along with accommodating infrequent eclipse periods lasting up to 100 hours, present the major technology challenges. Mitigation strategies to reduce the energy needed to maintain the SH and associated systems above survival temperature limits during the eclipse period are considered in the paper. Options include retractable radiators, re-generable heat exchangers, temperature excursions, thermal energy storage and optimized inflatable optical properties. TCS sensitivity to potential SH Electrical Power System (EPS) growth is also a consideration for both operational and dormant mission phases.

Thermal Control System↗