Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-G-BRA-03: PCA Based Imaging Angle Optimization for 2D Cine MRI Based Radiotherapy Guidance

Purpose: To develop an imaging angle optimization methodology for orthogonal 2D cine MRI based radiotherapy guidance using Principal Component Analysis (PCA) of target motion retrieved from 4DCT. Methods: We retrospectively analyzed 4DCT of 6 patients with lung tumor. A radiation oncologist manually contoured the target volume at the maximal inhalation phase of the respiratory cycle. An object constrained deformable image registration (DIR) method has been developed to track the target motion along the respiration at ten phases. The motion of the center of the target mass has been analyzed using the PCA to find out the principal motion components that were uncorrelated with each other. Two orthogonal image planes for cineMRI have been determined using this method to minimize the through plane motion during MRI based radiotherapy guidance. Results: 3D target respiratory motion for all 6 patients has been efficiently retrieved from 4DCT. In this process, the object constrained DIR demonstrated satisfactory accuracy and efficiency to enable the automatic motion tracking for clinical application. The average motion amplitude in the AP, lateral, and longitudinal directions were 3.6mm (min: 1.6mm, max: 5.6mm), 1.7mm (min: 0.6mm, max: 2.7mm), and 5.6mm (min: 1.8mm, max: 16.1mm), respectively. Based on PCA, the optimal orthogonal imaging planes were determined for cineMRI. The average angular difference between the PCA determined imaging planes and the traditional AP and lateral imaging planes were 47 and 31 degrees, respectively. After optimization, the average amplitude of through plane motion reduced from 3.6mm in AP images to 2.5mm (min:1.3mm, max:3.9mm); and from 1.7mm in lateral images to 0.6mm (min: 0.2mm, max:1.5mm), while the principal in plane motion amplitude increased from 5.6mm to 6.5mm (min: 2.8mm, max: 17mm). Conclusion: DIR and PCA can be used to optimize the orthogonal image planes of cineMRI to minimize the through plane motion during radiotherapy guidance.

60 APPLIED LIFE SCIENCES↗

Software for precise tracking of cell proliferation

Highlights: Black-Right-Pointing-Pointer We developed software for analyzing cultured cells that divide as well as migrate. Black-Right-Pointing-Pointer The active contour model (Snakes) was used as the core algorithm. Black-Right-Pointing-Pointer The time backward analysis was also used for efficient detection of cell division. Black-Right-Pointing-Pointer With user-interactive correction functions, the software enables precise tracking. Black-Right-Pointing-Pointer The software was successfully applied to cells with fluorescently-labeled nuclei. -- Abstract: We have developed a multi-target cell tracking program TADOR, which we applied to a series of fluorescence images. TADOR is based on an active contour model that is modified in order to be free of the problem of locally optimal solutions, and thus is resistant to signal fluctuation and morphological changes. Due to adoption of backward tracing and addition of user-interactive correction functions, TADOR is used in an off-line and semi-automated mode, but enables precise tracking of cell division. By applying TADOR to the analysis of cultured cells whose nuclei had been fluorescently labeled, we tracked cell division and cell-cycle progression on coverslips over an extended period of time.

60 APPLIED LIFE SCIENCES↗

Production of diverse PET probes with limited resources: 24 18 F-labeled compounds prepared with a single radiosynthesizer

Significance Molecular imaging with PET can provide a dynamic, whole-body picture of the rate of biological processes or distribution of biological targets by tracking the distribution of radiolabeled molecules or particles in the body over time. Continual efforts to develop new PET probes are expanding the variety of processes and targets that can be visualized, facilitating basic research, drug development, and patient care. However, access to these probes at all stages of their development is hindered by high costs arising, in large part, from the significant resources that are typically dedicated to production of a single probe. Emerging technologies with increased synthesis flexibility are allowing increased probe diversity with fewer resources and could significantly increase access to new molecular imaging agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

Autonomous Selective Parts-Based Tracking

Object tracking from videos is still a challenging task due to various changes throughout a video sequence including occlusions, motion blur, scale and other deformation changes. In this paper, we propose a selective parts-based approach, using correlation filters, that makes choices based on a consensus of the parts and global tracking. Moreover, we further enhance our parts-based approach by introducing a segmentation-assisted parts initialization. In addition, we present a genetic algorithm-based method to autonomously select various parameters of the tracking algorithm, as opposed to the common practice of manually tuning those parameters. In contrast to existing part-based methods, the proposed method does not dilute accurate tracking by averaging results over multiple parts at every frame. Instead, we take a selective approach based on the relative weight of the responses across parts. Moreover, we only make location corrections when a part diverges, and rely on these location corrections to maintain an accurate appearance model. In the case of occlusions, which are among the main reasons for using a parts-based approach, our proposed approach consistently achieves the best performance. It is due to the ability to handle occlusion and not dilute decisions with incorrect parts, that our proposed approach enables state-of-the-art performance. The approach we propose was evaluated on videos from three different challenging benchmark datasets. Our approach has resulted in better overall precision and success rates for three different base tracking approaches.

42 ENGINEERING↗

Measurement, reporting and Verification (MRV) of non-CO 2 greenhouse gases: International Best Practices and Suggestions for China

Measurement, Reporting, and Verification (MRV) is a systematic approach to tracking and documenting greenhouse gas (GHG) emissions and emission reductions. MRV can be used across all sectors and for all GHGs to track emissions patterns, evaluate programs, and promote transparency. As methane and other short-lived climate pollutants become critical to mitigating near-term climate change impacts, MRV systems become critical in improving emission inventories; facilitating the development of climate change policies and targets, and tracking and demonstrating progress towards sustainable development. This report focuses on current sectoral issues – including the emerging roles for satellites and remote sensing technologies - and international best practices in MRV policies and programs for non-carbon dioxide (CO 2 ) GHGs including methane, nitrous oxide (N 2 O), and hydrofluorocarbons (HFCs) in specific sectors. Based on international best practices and a review of China’s current MRV system, we offer suggestions for a possible path forward for developing and implementing a stronger non-CO 2 MRV system.

54 ENVIRONMENTAL SCIENCES↗

Tracking Error Learning Control for Precise Mobile Robot Path Tracking in Outdoor Environment

This article presents a Tracking-Error Learning Control (TELC) algorithm for precise mobile robot path tracking in off-road terrain. In traditional tracking error-based control approaches, feedback and feedforward controllers are designed based on the nominal model which cannot capture the uncertainties, disturbances and changing working conditions so that they cannot ensure precise path tracking performance in the outdoor environment. In TELC algorithm, the feedforward control actions are updated by using the tracking error dynamics and the plant-model mismatch problem is thus discarded. Therefore, the feedforward controller gradually eliminates the feedback controller from the control of the system once the mobile robot has been ontrack. In addition to the proof of the stability, it is proven that the cost functions do not have local minima so that the coefficients in TELC algorithm guarantee that the global minimum is reached. The experimental results show that the TELC algorithm results in better path tracking performance than the traditional tracking error-based control method. The mobile robot controlled by TELC algorithm can track a target path precisely with less than 10 cm error in off-road terrain.

42 ENGINEERING↗

SU-E-J-42: Evaluation of Fiducial Markers for Ultrasound and X-Ray Images Used for Motion Tracking in Pancreas SBRT

Purpose Ultrasound tracking of target motion relies on visibility of vascular and/or anatomical landmark. However this is challenging when the target is located far from vascular structures or in organs that lack ultrasound landmark structure, such as in the case of pancreas cancer. The purpose of this study is to evaluate visibility, artifacts and distortions of fusion coils and solid gold markers in ultrasound, CT, CBCT and kV images to identify markers suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment. Methods Two fusion coils (1mm × 5mm and 1mm × 10 mm) and a solid gold marker (0.8mm × 10mm) were embedded in a tissue–like ultrasound phantom. The phantom (5cm × 12cm × 20cm) was prepared using water, gelatin and psyllium-hydrophilic-mucilloid fiber. Psylliumhydrophilic mucilloid acts as scattering medium to produce echo texture that simulates sonographic appearance of human tissue in ultrasound images while maintaining electron density close to that of water in CT images. Ultrasound images were acquired using 3D-ultrasound system with markers embedded at 5, 10 and 15mm depth from phantom surface. CT images were acquired using Philips Big Bore CT while CBCT and kV images were acquired with XVI-system (Elexta). Visual analysis was performed to compare visibility of the markers and visibility score (1 to 3) were assigned. Results All markers embedded at various depths are clearly visible (score of 3) in ultrasound images. Good visibility of all markers is observed in CT, CBCT and kV images. The degree of artifact produced by the markers in CT and CBCT images are indistinguishable. No distortion is observed in images from any modalities. Conclusion All markers are visible in images across all modalities in this homogenous tissue-like phantom. Human subject data is necessary to confirm the marker type suitable for real-time ultrasound tracking of tumor motion in SBRT pancreas treatment.

60 APPLIED LIFE SCIENCES↗

Projection-based circular constrained state estimation and fusion over long-haul links

In this paper, we consider a scenario where sensors are deployed over a large geographical area for tracking a target with circular nonlinear constraints on its motion dynamics. The sensor state estimates are sent over long-haul networks to a remote fusion center for fusion. We are interested in different ways to incorporate the constraints into the estimation and fusion process in the presence of communication loss. In particular, we consider closed-form projection-based solutions, including rules for fusing the estimates and for incorporating the constraints, which jointly can guarantee timely fusion often required in realtime systems. We test the performance of these methods in the long-haul tracking environment using a simple example.

Liu, Qiang↗

SU-D-18A-04: Quantifying the Ability of Tumor Tracking to Spare Normal Tissue

Purpose: Tumor tracking allows for smaller tissue volumes to be treated, potentially reducing normal tissue damage. However, tumor tracking is a more complex treatment and has little benefit in some scenarios. Here we quantify the benefit of tumor tracking for a range of patients by estimating the dose of radiation to organs at risk and the normal tissue complication probability (NTCP) for both standard and tracking treatment plans. This comparison is performed using both patient 4DCT data and extended Cardiac-Torso (XCAT) digital phantoms. Methods: We use 4DCT data for 10 patients. Additionally, we generate digital phantoms with motion derived from measured patient long tumor trajectories to compare standard and tracking treatment plans. The standard treatment is based on the average intensity projection (AIP) of 4DCT images taken over a breath cycle. The tracking treatment is based on doses calculated on images representing the anatomy at each time point. It is assumed that there are no errors in tracking the target. The NTCP values are calculated based on RTOG guidelines. Results: The mean reduction in the mean dose delivered was 5.5% to the lungs (from 7.3 Gy to 6.9 Gy) and 4.0% to the heart (from 12.5 Gy to 12.0 Gy). The mean reduction in the max dose delivered was 13% to the spinal cord (from 27.6 Gy to 24.0 Gy), 2.5% to the carina (from 31.7 Gy to 30.9 Gy), and 15% to the esophagus (from 69.6 Gy to 58.9 Gy). The mean reduction in the probability of 2nd degree radiation pneumonitis (RP) was 8.7% (3.1% to 2.8%) and the mean reduction in the effective volume was 6.8% (10.8% to 10.2%). Conclusions: Tumor tracking has the potential to reduce irradiation of organs at risk, and consequentially reduce the normal tissue complication probability. The benefits vary based on the clinical scenario. This study is supported by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

Stationary and drone-assisted methane plume localization with dispersion spectroscopy

This work presents stationary and mobile retroreflector-based remote sensing techniques for methane leak localization and quantification using chirped laser dispersion spectroscopy equipped with a custom laser transceiver capable of continuous tracking of a flying drone and coupled with inverse atmospheric gas dispersion modeling. The techniques demonstrate the ability to localize leaks as low as 0.13 g CH 4 ·s -1 , which are up to 25 times smaller than those typically observed at natural gas facilities, as well as actively track a moving retroreflector mounted on a lightweight (~250 g) drone to enable spatial plume reconstruction. This system exhibited a 2.3 ppm-m sensitivity over pathlengths of 40–150 m. Source localization to within ±7 m is demonstrated using a modified horizontal radial plume mapping technique with a stationary retroreflector grid. Meanwhile, the mobile system utilizing a drone-mounted retroreflector is able to localize a controlled release within ±1 m of its source location and estimate leak rates using inversion techniques assuming type B Gaussian plume stability class within ±30% error with respect to the actual low flow rate releases.

47 OTHER INSTRUMENTATION↗

Fast track, dynein-dependent nuclear targeting of human immunodeficiency virus Vpr protein; impaired trafficking in a clinical isolate

Nuclear import of the accessory protein Vpr is central to infection by human immunodeficiency virus (HIV). We previously identified the Vpr F72L mutation in a HIV-infected, long-term non-progressor, showing that it resulted in reduced Vpr nuclear accumulation and altered cytoplasmic localisation. Here we demonstrate for the first time that the effects of nuclear accumulation of the F72L mutation are due to impairment of microtubule-dependent-enhancement of Vpr nuclear import. We use high resolution imaging approaches including fluorescence recovery after photobleaching and other approaches to document interaction between Vpr and the dynein light chain protein, DYNLT1, and impaired interaction of the F72L mutant with DYNLT1. The results implicate MTs/DYNLT1 as drivers of Vpr nuclear import and HIV infection, with important therapeutic implications. - Highlights: • HIV-1 Vpr utilizes the microtubule network to traffic towards the nucleus. • Mechanism relies on interaction between Vpr and dynein light chain protein DYNLT1. • Long-term non-progressor derived mutation (F72L) impairs this interaction. • Key residues in the vicinity of F72 contribute to interaction with DYNLT1.

60 APPLIED LIFE SCIENCES↗

Improved Clinical Outcomes With High-Dose Image Guided Radiotherapy Compared With Non-IGRT for the Treatment of Clinically Localized Prostate Cancer

Purpose: To compare toxicity profiles and biochemical tumor control outcomes between patients treated with high-dose image-guided radiotherapy (IGRT) and high-dose intensity-modulated radiotherapy (IMRT) for clinically localized prostate cancer. Materials and Methods: Between 2008 and 2009, 186 patients with prostate cancer were treated with IGRT to a dose of 86.4 Gy with daily correction of the target position based on kilovoltage imaging of implanted prostatic fiducial markers. This group of patients was retrospectively compared with a similar cohort of 190 patients who were treated between 2006 and 2007 with IMRT to the same prescription dose without, however, implanted fiducial markers in place (non-IGRT). The median follow-up time was 2.8 years (range, 2-6 years). Results: A significant reduction in late urinary toxicity was observed for IGRT patients compared with the non-IGRT patients. The 3-year likelihood of grade 2 and higher urinary toxicity for the IGRT and non-IGRT cohorts were 10.4% and 20.0%, respectively (p = 0.02). Multivariate analysis identifying predictors for grade 2 or higher late urinary toxicity demonstrated that, in addition to the baseline Internatinoal Prostate Symptom Score, IGRT was associated with significantly less late urinary toxicity compared with non-IGRT. The incidence of grade 2 and higher rectal toxicity was low for both treatment groups (1.0% and 1.6%, respectively; p = 0.81). No differences in prostate-specific antigen relapse-free survival outcomes were observed for low- and intermediate-risk patients when treated with IGRT and non-IGRT. For high-risk patients, a significant improvement was observed at 3 years for patients treated with IGRT compared with non-IGRT. Conclusions: IGRT is associated with an improvement in biochemical tumor control among high-risk patients and a lower rate of late urinary toxicity compared with high-dose IMRT. These data suggest that, for definitive radiotherapy, the placement of fiducial markers and daily tracking of target positioning may represent the preferred mode of external-beam radiotherapy delivery for the treatment of prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal control of the electron temperature profile in DIII-D using machine learning surrogate models

The viability of the tokamak as a potential fusion reactor depends on the ability to keep the plasma in a stable regime while achieving temperatures, densities, and confinement times that are as high as possible. Tokamak scenario development attempts to find plasma regimes that achieve all of these conditions and are accessible with a given set of hardware constraints. This requires the ability to control plasma properties such as the normalized beta, the internal inductance, safety factor, rotation, etc. One property that has received less attention than some of the others, but is no less critical to achieving high performance, is the electron temperature (T e ) profile. In this work, Linear Quadratic Integral (LQI) control is used to develop a controller for the electron temperature profile in DIII-D. The controller is based on a linearized model derived from the transport equation that describes the evolution of the electron temperature, and includes contributions from the neural network surrogate models NubeamNet and MMMnet. Furthermore, the controller is tested in simulation using COTSIM, and is proven capable of tracking a target T e profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methods for optical calibration of the BigBite hadron spectrometer

In this study, the techniques for the optical calibration of Jefferson Lab's large-acceptance magnetic hadron spectrometer, BigBite, have been examined. The most consistent and stable results were obtained using a method based on singular value decomposition. In spite of the complexity of the optics, the particles' positions and momenta at the target have been precisely reconstructed from the coordinates measured in the detectors by means of a single back-tracing matrix. The technique is applicable to any similar magnetic spectrometer and any particle type. For 0.55 GeV/c protons, we have established a vertex resolution of 1.2 cm, angular resolutions of 7 mrad and 13 mrad (in-plane and out-of-plane, respectively), and a relative momentum resolution of 1.6%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the 2-Phase Bubble Tracking Model for Liquid Mercury Target Simulation with Machine Learning Surrogate Models

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is one of the most powerful accelerator-driven neutron sources in the world. The intense protons strike on SNS's mercury target to provide bright neutron beams, which also leads to severe fluid-structure interactions inside the target. Prediction of resultant loading on the target is difficult particularly when helium gas is injected into mercury to reduce the loading and mitigate the pitting damage on vessel walls. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this multi-physics problem. However, several uncertain parameters in the R-P model require intensive simulations to determine their optimal values. With the help of machine learning and the measured target strain, we have studied the major uncertain parameters in this R-P model and developed a framework to identify optimal parameters that significantly reduce the discrepancy between simulations and experimental strains. The preliminary results show the possibility of using this mercury/helium mixture and surrogate models to predict a better match of target strain response when the helium gas is injected.

Lin, Lianshan↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗