Preliminary Tests in the NACA Tank to Investigate the Fundamental Characteristics of Hydrofoils
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.
Powering desalination processes with renewable energy is a promising solution to address the global issue of water shortage with minimum carbon footprint and environmental impact. Here, we experimentally investigate a sustainable reverse osmosis (RO) desalination system directly powered by wave energy. In this system, seawater is pressurized and pumped to a RO desalination module via a piston pump directly driven by an oscillating surge wave energy converter (OSWEC). An accumulator is adopted on the feed inlet to mitigate the pressure fluctuations under time-varying ocean conditions. Meanwhile, a needle valve on the brine outlet is used to adjust the system pressure and water recovery. A 1:10 scaled model was designed, fabricated, and tested in a wave tank based on the Froude scaling law. Further, the optimal specific water productivity (SWP) obtained in the tank tests with 3.5 g/L feed salinity was 2.23m 3 /kWh, indicating a full-scale specific water productivity of 0.22m 3 /kWh for 35g/L seawater salinity. The influence of needle valve tuning on the specific water productivity was experimentally investigated and analyzed. Under a specific operational condition, tuning this valve improved specific water productivity by about 17% and reduced the system pressure by 24%, thereby avoiding extreme pressure and improving the system’s capability. This pilot study demonstrates that ocean wave energy is a promising source to sustainably power reverse osmosis desalination and provide freshwater water for coastal regions.
Heat transfer rates and pressures were measured on a 0.0175-scale model of the space shuttle external tank (ET), model MCR0200. Tests were conducted with the ET model separately and while mated with a 0.0175-scale model of the orbiter, model 21-OT (Grumman). The tests were conducted in the AEDC-VKF Hypervelocity Wind Tunnel (F) at Mach numbers 16 and 19. The primary data consisted of the interaction heating rates experienced by the ET while mated with the orbiter in the flight configuration. Data were taken for a range of Reynolds numbers from 50,000 to 65,000 under laminar flow conditions.
Self pressurization by propellant boiloff is experimentally studied as an alternate pressurization concept for the Space Shuttle external tank (ET). The experimental setup used in the study is an open flow system which is composed of a variable area test tank and a recovery tank. The vacuum jacketed test tank is geometrically similar to the external LOx tank for the Space Shuttle. It is equipped with instrumentation to measure the temperature and pressure histories within the liquid and vapor, and viewports to accommodate visual observations and Laser-Doppler Anemometry measurements of fluid velocities. A set of experiments were conducted using liquid Nitrogen to determine the temperature stratification in the liquid and vapor, and pressure histories of the vapor during sudden and continuous depressurization for various different boundary and initial conditions. The study also includes the development and calibration of a computer model to simulate the experiments. This model is a one-dimensional, multi-node type which assumes the liquid and the vapor to be under non-equilibrium conditions during the depressurization. It has been tested for a limited number of cases. The preliminary results indicate that the accuracy of the simulations is determined by the accuracy of the heat transfer coefficients for the vapor and the liquid at the interface which are taken to be the calibration parameters in the present model.
Metal corrosion prevention methods for Centaur launch vehicle liquid propellant tanks
This data and report details the findings from a wave tank test focused on production of useful work of a wave energy converter (WEC) device. The experimental system and test were specifically designed to validate models for power transmission throughout the WEC system. Additionally, the validity of co-design informed changes to the power take-off (PTO) were assessed and shown to provide the expected improvements in system performance. These data describe the "MASK4" wave tank test of the Sandia WaveBot device. The WaveBot device has been tested a number of times in different permutations at the US Navy's Maneuvering and Sea Keeping (MASK) basin. Each test in this series is referred to as MASK1, MASK2, etc. The WaveBot device was first tested in one degree of freedom (heave) in 2016. This MASK1 test focused primarily on system identification and modeling. After MASK1, major modifications were performed to improve the overall real-time control and measurement system, improve the heave drive train, and add surge and pitch degrees of freedom. The second set of testing, which was broken up in to two stages: MASK2A and MASK2B, focused on bench testing and closed-loop control performance as well as nonlinear modeling. MASK3 then focused on multi-input, multi-output modeling and control for maximization of electrical power. The attached report presents the results from MASK4, which focuses on detailed modeling of the power conversion chain and validation co-design principles by way of the introduction of a magnetic spring. The test log, report, and data from the MASK4 test of the WaveBot augmented with a tunable magnetic spring. Processing codes can be found at the Github link below.
The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing, both thermal and structural was performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.
The development of long duration orbital cryogenic storage systems will require the reduction of heat loads into the storage tank. In the case of liquid hydrogen, complete elimination of the heat load at 20 K is currently impractical due to the limitations in lift available on flight cryocoolers. In order to reduce the heat load, without having to remove heat at 20 K, the concept of Reduced Boil-Off uses cooled shields within the insulation system at approximately 90 K. The development of Load-Bearing Multilayer Insulation (LB-MLI) allowed the 90 K shield with tubing and cryocooler attachments to be suspended within the MLI and still be structurally stable. Coupon testing both thermally and structurally were performed to verify that the LB-MLI should work at the tank applied level. Then tank applied thermal and structural (acoustic) testing was performed to demonstrate the functionality of the LB-MLI as a structural insulation system. The LB-MLI showed no degradation of thermal performance due to the acoustic testing and showed excellent thermal performance when integrated with a 90 K class cryocooler on a liquid hydrogen tank.
Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.
The applicability of the RF Mode Counting technique for gauging liquid oxygen and liquid hydrogen under all attitude conditions was demonstrated using a vacuum jacketed test tank mounted on a remotely controlled gimbaling mechanism. In addition, the technique was successfully tested using liquid oxygen in a large NASA test tank as the tank was filled and emptied. To further substantiate the capabilities of the RF Mode Counting technique as applied to applications involving zero gravity conditions, a test system using benzene as a test fluid was flight tested in a KC-135 test aircraft. This testing involved a number of zero "g" maneuvers with various quantities of the test fluid. A series of tests were also performed to evaluate the relative effects of the presence of capillary liquid retention screens on the RF Gauging technique. These tests involved considerations of system Q reductions, RF leakage through retention screens, and surface wetting effects.
Tests were conducted on scale models of the space shuttle orbiter and external tank (ET) to determine the aerodynamic interactions during a return to launch site abort separation. The orbiter model was built to vehicle 3 configuration lines (139B) and the ET model approximated the vehicle 5 configurations with protuberances and attach hardware. For these investigations the orbiter was mounted on the primary support system and the external tank was mounted on the captive trajectory system. Six-component data were obtained for each vehicle at various orbiter angles of attack and sideslip for a range of relative angular and linear displacements of the ET from the orbiter.
NASA Lewis Research has been investigating the no-vent fill method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. 22 tests were conducted, 10 with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia, transfer pressures of 20, 30, and 45 psia, and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool down of the higher starting wall temperature fills.
NASA Lewis Research has been investigating the no-vent till method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. Twenty two tests were conducted, ten with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia; transfer pressures of 20, 30, and 45 psia; and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool-down of the higher starting wall temperature fills.
Foam multilayer insulation (FMLI), a reusable thermal control system (TCS), was evaluated in a simulated orbit hold environment on a test tank of 3.0 ft diameter, 5.6 ft length, and 34.5 cu ft volume. The TCS consisted of a 0.44-inch thick foam and a 16-layer (17 sheet) MLI blanket attached to the tank barrel and lower bulkhead, with the upper bulkhead covered with a 2.7-inch foam and a 31-layer (32 sheets) MLI blanket. Average insulation heating rates during orbit hold simulations ranged from 10.5 to 28.1 Btu/hr for warm boundary temperatures from 300 to 460 R, respectively. These rates corresponded to liquid losses of 0.9 and 2.3 percent of the tank's volume per day. This liquid loss rate would be significantly reduced for full size vehicle tanks due to the decreased surface area-to-volume ratio as compared to the test tank.
This paper presents a numerical benchmark study of wave propagation due to a paddle motion using different high-fidelity numerical models, which are capable of replicating the nearly actual physical wave tank testing. A full time series of the measured wave generation paddle motion which was used to generate wave propagation in the physical wave tank will be utilized in each of the models contributed by IEA OES Task 10's participants, which includes both computational fluid dynamics (CFD) and smooth hydrodynamic particle (SPH). The high-fidelity simulations of the physical wave testcase will allow for the evaluation of the initial transient effects from wave ramp-up and its evolution in the wave tank over time for two representative regular waves with varying levels of nonlinearity. A couple of interesting metrics like the predicted wave surface elevation at select wave probes, wave period, and phase-shift in time will be assessed to evaluate the relative accuracy of numerical models versus experimental data within specified time intervals. These models will serve as a guide for modelers in the wave energy community and provide a base case to allow further and more detailed numerical modeling of the fixed Kramer Sphere Cases under wave excitation force wave tank testing.
The power reactant storage assembly (PRSA) hydrogen tank test data were reviewed. Two hundred and nineteen data points illustrating the effect of flow rate, temperature ratio and configuration were identified. The test data were reduced to produce the thermal acoustic oscillation parameters. Frequency and amplitude were determined for model correlation. A comparison of PRSA hydrogen tank test data with the analytical models indicated satisfactory agreement for the supply and poor agreement for the full line.
Slush hydrogen is currently being considered as a fuel for the National AeroSpace Plane (NASP) because it offers the potential for decreased vehicle size and weight. However, no large scale data was available on the production, transfer, and tank pressure control characteristics required to use the fuel for the NASP. Therefore, experiments were conducted at NASA-Lewis K-Site Facility to improve the slush hydrogen data base. Slush hydrogen was produced using the evaporative cooling, or freeze-thaw, technique in batches for approx. 800 gallons. This slush hydrogen was pressure transferred to a 5 ft diameter spherical test tank following production, and flow characteristics were measured during this transfer process. The slush hydrogen in the test tank was pressurized and expelled using a pressurized expulsion technique to obtain information on tank pressure control for the NASP. Results from the production, transfer, pressurization, and pressurized expulsion tests are described.