Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TREATMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

"Sequential” Boron Neutron Capture Therapy (BNCT): A Novel Approach to BNCT for the Treatment of Oral Cancer in the Hamster Cheek Pouch Model

Boron Neutron Capture Therapy (BNCT) is a binary treatment modality that involves the selective accumulation of 10B carriers in tumors followed by irradiation with a thermal or epithermal neutron beam. The minor abundance stable isotope of boron, 10B, interacts with low energy (thermal) neutrons to produce high linear energy transfer (LET) a-particles and 7Li ions. These disintegration products are known to have a high relative biological effectiveness (RBE). Their short range (<10 {micro}m) would limit the damage to cells containing 10B (1,2). Thus, BNCT would target tumor tissue selectively, sparing normal tissue. Clinical trials of BNCT for the treatment of glioblastoma multiforme and/or melanoma and, more recently, head and neck tumors and liver metastases, using boronophenylalanine (BPA) or sodium mercaptoundecahydrododecaborane (BSH) as the 10B carriers, have been performed or are underway in Argentina, Japan, the US and Europe (e.g. 3-8). To date, the clinical results have shown a potential, albeit inconclusive, therapeutic advantage for this technique. Contributory translational studies have been carried out employing a variety of experimental models based on the implantation of tumor cells in normal tissue (e.g. 5).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Extreme Decentralized Water Treatment: Exploring the Future of Premise-Scale Water Treatment and Reuse

Access to an adequate quantity of piped water and management of wastewater produced in homes and businesses is an expectation of city dwellers in wealthy countries, and an aspiration for many people living in rapidly developing cities in low- and middle-income countries. It is also crucial to public health and protection of the environment. For well over a century, municipal drinking water provision and wastewater management have been made possible by large investments in centralized systems in which fresh water passes through a small number of drinking water treatment plants before being distributed through a vast underground pipe network to buildings throughout the city (Sedlak 2014). After it is used, wastewater is collected in underground sewers that route it to treatment plants prior to its discharge to the environment. In some water-stressed cities, a fraction of the treated wastewater undergoes additional treatment prior to reuse. This recycled water often is returned to users through another dedicated water distribution system, which is designated in many places with purple pipes (non-potable water reuse). Alternatively, treated wastewater may be subjected to advanced treatment (e.g., reverse osmosis followed by advanced oxidation) prior to being returned to the drinking water supply (potable water reuse).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A new WRF-Chem treatment for studying regional-scale impacts of cloud processes on aerosol and trace gases in parameterized cumuli

A new treatment of cloud effects on aerosol and trace gases within parameterized shallow and deep convection, and aerosol effects on cloud droplet number, has been implemented in the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) version 3.2.1 that can be used to better understand the aerosol life cycle over regional to synoptic scales. The modifications to the model include treatment of the cloud droplet number mixing ratio; key cloud microphysical and macrophysical parameters (including the updraft fractional area, updraft and downdraft mass fluxes, and entrainment) averaged over the population of shallow clouds, or a single deep convective cloud; and vertical transport, activation/resuspension, aqueous chemistry, and wet removal of aerosol and trace gases in warm clouds. These changes have been implemented in both the WRF-Chem chemistry packages as well as the Kain–Fritsch (KF) cumulus parameterization that has been modified to better represent shallow convective clouds. Testing of the modified WRF-Chem has been completed using observations from the Cumulus Humilis Aerosol Processing Study (CHAPS). The simulation results are used to investigate the impact of cloud–aerosol interactions on regional-scale transport of black carbon (BC), organic aerosol (OA), and sulfate aerosol. Based on the simulations presented here, changes in the column-integrated BC can be as large as –50% when cloud–aerosol interactions are considered (due largely to wet removal), or as large as +40% for sulfate under non-precipitating conditions due to sulfate production in the parameterized clouds. The modifications to WRF-Chem are found to account for changes in the cloud droplet number concentration (CDNC) and changes in the chemical composition of cloud droplet residuals in a way that is consistent with observations collected during CHAPS. Efforts are currently underway to port the changes described here to the latest version of WRF-Chem, and it is anticipated that they will be included in a future public release of WRF-Chem.

54 ENVIRONMENTAL SCIENCES↗

Effects of inlet treatment location and treatment cavity depth on compressor noise

The ability of acoustic liners to reduce compressor noise inside and in front of an inlet was studied. An axial flow research compressor and a specially designed inlet were used inside an anechoic chamber. Acoustic and performance data were obtained for a range of inlet treatment locations and cavity depths to determine their effects on inlet noise over a range of blade passing frequencies. The greatest noise reductions in front of the inlet were obtained with acoustic treatment located close to the compressor and backed with the deepest cavities tested. Inside the inlet the maximum noise level reductions were obtained in the area of the treatment regardless of treatment location. No appreciable losses in compressor performance were measured.

Clark, L. R.↗

Glioblastoma Treatment: Bypassing the Toxicity of Platinum Compounds by Using Liposomal Formulation and Increasing Treatment Efficiency With Concomitant Radiotherapy

Purpose: Treatments of glioblastoma with cisplatin or oxaliplatin only marginally improve the overall survival of patients and cause important side effects. To prevent adverse effects, improve delivery, and optimize the tumor response to treatment in combination with radiotherapy, a potential approach consists of incorporating the platinum agent in a liposome. Methods and Materials: In this study, cisplatin, oxaliplatin, carboplatin, Lipoplatin (the liposomal formulation of cisplatin), and Lipoxal (the liposomal formulation of oxaliplatin) were tested on F98 glioma orthotopically implanted in Fischer rats. The platinum compounds were administered by intracarotid infusion and were assessed for the ability to reduce toxicity, improve cancer cell uptake, and increase survival of animals when combined or not combined with radiotherapy. Results: The tumor uptake was 2.4-fold more important for Lipoxal than the liposome-free oxaliplatin. Lipoxal also improved the specificity of oxaliplatin as shown by a higher ratio of tumor to right hemisphere uptake. Surprisingly, Lipoplatin led to lower tumor uptake compared with cisplatin. However, Lipoplatin had the advantage of largely reducing the toxicity of cisplatin and allowed us to capitalize on the anticancer activity of this agent. Conclusion: Among the five platinum compounds tested, carboplatin showed the best increase in survival when combined with radiation for treatment of glioma implanted in Fischer rats.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictive Treatment Management: Incorporating a Predictive Tumor Response Model Into Robust Prospective Treatment Planning for Non-Small Cell Lung Cancer

Purpose: We hypothesized that a treatment planning technique that incorporates predicted lung tumor regression into optimization, predictive treatment planning (PTP), could allow dose escalation to the residual tumor while maintaining coverage of the initial target without increasing dose to surrounding organs at risk (OARs). Methods and Materials: We created a model to estimate the geometric presence of residual tumors after radiation therapy using planning computed tomography (CT) and weekly cone beam CT scans of 5 lung cancer patients. For planning purposes, we modeled the dynamic process of tumor shrinkage by morphing the original planning target volume (PTV{sub orig}) in 3 equispaced steps to the predicted residue (PTV{sub pred}). Patients were treated with a uniform prescription dose to PTV{sub orig}. By contrast, PTP optimization started with the same prescription dose to PTV{sub orig} but linearly increased the dose at each step, until reaching the highest dose achievable to PTV{sub pred} consistent with OAR limits. This method is compared with midcourse adaptive replanning. Results: Initial parenchymal gross tumor volume (GTV) ranged from 3.6 to 186.5 cm{sup 3}. On average, the primary GTV and PTV decreased by 39% and 27%, respectively, at the end of treatment. The PTP approach gave PTV{sub orig} at least the prescription dose, and it increased the mean dose of the true residual tumor by an average of 6.0 Gy above the adaptive approach. Conclusions: PTP, incorporating a tumor regression model from the start, represents a new approach to increase tumor dose without increasing toxicities, and reduce clinical workload compared with the adaptive approach, although model verification using per-patient midcourse imaging would be prudent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flue Gas Desulfurization Wastewater Composition and Implications for Regulatory and Treatment Train Design

The U.S. Environmental Protection Agency is currently revising its regulations on trace element discharges from flue gas desulfurization (FGD) wastewater.<br>In this work, we expand a predictive model of trace element behavior at coal-fired power plants (CFPPs) to estimate the trace element concentration of FGD wastewater at the plant level. We demonstrate that variation in trace element concentrations in FGD wastewater can span several orders of magnitude and is a function of both coal rank and installed air pollution control devices. This conclusion suggests that the benefits and costs of FGD wastewater treatment for the median plant will poorly describe the actual benefits and costs over the full range of existing CFPPs.

Mauter, Meagan↗

SU-E-T-504: Intensity-Modulated Radiosurgery Treatments Derived by Optimizing Delivery of Sphere Packing Treatment Plans

Purpose To minimize the number of monitor units required to deliver a sphere packing stereotactic radiosurgery (SRS) plan by eliminating overlaps of individual beam projections. Methods An algorithm was written in C{sup ++} to calculate SRS treatment doses using sphere packing. Three fixed beams were used to approximate each arc in a typical SRS treatment plan. For cases involving multiple isocenters, at each gantry and table angle position beams directed to individual spheres overlap to produce regions of high dose, resulting in intensity modulated beams. These high dose regions were dampened by post-processing of the combined beam profile. The post-process dampening involves removing the excess overlapping fluence from all but the highest contributing beam. The dampened beam profiles at each table and gantry angle position were then summed to produce the new total dose distribution. Results Delivery times for even the most complex multiple sphere plans can be reduced to consistent times of about 20 to 30 minutes. The total MUs required to deliver the plan can also be reduced by as much as 85% of the original plan’s MUs. Conclusion Regions of high dose are removed. Dampening overlapping radiation fluence can produce the new beam profiles that have more uniform dose distributions using less MUs. This results in a treatment that requires significantly fewer intensity values than traditional IMRT or VAMT planning.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRB-03: Coverage-Based Treatment Planning to Accommodate Organ Deformable Motions and Contouring Uncertainties for Prostate Treatment

The accepted clinical method to accommodate targeting uncertainties inherent in fractionated external beam radiation therapy is to utilize GTV-to-CTV and CTV-to-PTV margins during the planning process to design a PTV-conformal static dose distribution on the planning image set. Ideally, margins are selected to ensure a high (e.g. >95%) target coverage probability (CP) in spite of inherent inter- and intra-fractional positional variations, tissue motions, and initial contouring uncertainties. Robust optimization techniques, also known as probabilistic treatment planning techniques, explicitly incorporate the dosimetric consequences of targeting uncertainties by including CP evaluation into the planning optimization process along with coverage-based planning objectives. The treatment planner no longer needs to use PTV and/or PRV margins; instead robust optimization utilizes probability distributions of the underlying uncertainties in conjunction with CP-evaluation for the underlying CTVs and OARs to design an optimal treated volume. This symposium will describe CP-evaluation methods as well as various robust planning techniques including use of probability-weighted dose distributions, probability-weighted objective functions, and coverage optimized planning. Methods to compute and display the effect of uncertainties on dose distributions will be presented. The use of robust planning to accommodate inter-fractional setup uncertainties, organ deformation, and contouring uncertainties will be examined as will its use to accommodate intra-fractional organ motion. Clinical examples will be used to inter-compare robust and margin-based planning, highlighting advantages of robust-plans in terms of target and normal tissue coverage. Robust-planning limitations as uncertainties approach zero and as the number of treatment fractions becomes small will be presented, as well as the factors limiting clinical implementation of robust planning. Learning Objectives: To understand robust-planning as a clinical alternative to using margin-based planning. To understand conceptual differences between uncertainty and predictable motion. To understand fundamental limitations of the PTV concept that probabilistic planning can overcome. To understand the major contributing factors to target and normal tissue coverage probability. To understand the similarities and differences of various robust planning techniques To understand the benefits and limitations of robust planning techniques.

60 APPLIED LIFE SCIENCES↗

Dimensional changes of Nb 3 Sn Rutherford cables during heat treatment

In high field magnet applications, Nb 3 Sn coils undergo a heat treatment step after winding. During this stage, coils radially expand and longitudinally contract due to the Nb 3 Sn phase change. In order to prevent residual strain from altering superconducting performances, the tooling must provide the adequate space for these dimensional changes. The aim of this paper is to understand the behavior of cable dimensions during heat treatment and to provide estimates of the space to be accommodated in the tooling for coil expansion and contraction. In addition, this paper summarizes measurements of dimensional changes on strands, single Rutherford cables, cable stacks, and coils performed between 2013 and 2015. These samples and coils have been performed within a collaboration between CERN and the U.S. LHC Accelerator Research Program to develop Nb 3 Sn quadrupole magnets for the HiLumi LHC. The results are also compared with other high field magnet projects.

43 PARTICLE ACCELERATORS↗

Characterisation and heat treatment of chloride-contaminated and humidified PuO2 samples

To mimic the reactions that have occurred between plutonium dioxide (PuO2) and degraded polyvinyl chloride during prolonged storage, batches of PuO2 powders with varying specific surface area (4-38m2 g1) were exposed to dry hydrogen chloride gas forming a surface-sorbed exchangeable chloride species that was readily leached by dilute caustic solution. One batch was also humidified under a 95% relative humidity atmosphere. Heat treatment at temperatures between 100 and 950 C steadily reduced the leachable chloride content at least when the initial leachable chloride surface coverage was calculated to be > 0.5 monolayer (ML). Variations between samples are attributed to differences in surface area as well as production route and period of interim storage in air or humidified atmospheres. The data are consistent with surface species and reactions proposed in the literature for HCl adsorption on to TiO2. This indicates that it is interactions between hydrogen chloride/chloride and water/hydroxyl species on the PuO2 surface that are key to understanding the behaviour of these materials when heated in a furnace. These data will inform the design of a future thermal stabilisation process for chloride-contaminated PuO2.

Sutherland-Harper, Sophie↗

The Power Reclamation of Utilizing Micro-Hydro Turbines in the Aeration Basins of Wastewater Treatment Plants

Upgrading the aeration basin technology can improve the oxygen transfer efficiency (OTE), while keeping the energy consumption at its minimum level. Therefore, this paper introduces a new idea of installing micro-propeller turbines in the aeration basin of a wastewater treatment plant (WWTP) to extract power from the high-velocity location in the water column. This extracted power can be used to operate a mixer at the top of the membrane to induce the mixing in that region, which will drive the less oxygenated wastewater into the water column. The rest of the extracted power will rotate microturbine rotors for electric power generation. By applying the proposed microturbines to the 13 audited facilities, it was demonstrated to achieve a gross annual energy-savings of 3,836.9 MWh, a gross annual cost-saving of $260,497, and total CO 2 emissions that would be reduced by 2,714 metric tons/year. Generally, the addition of the proposed microturbines can save up to 15.7% of the annual plant electricity consumption (1.3–12.8% of the plant annual electricity bills).

13 HYDRO ENERGY↗

Evaluation of Ammonium and Iodine Decontamination Factors for Hanford's Waste Treatment and Immobilization Plant Feed in the Effluent Treatment Facility

Savannah River National Laboratory (SRNL) reviewed the unit operations in the Effluent Treatment Facility (FTP) at the Hanford site to estimate the partitioning of iodine and ammonia when processing Waste Treatments and Immobilization Plant (WTP) feed. The evaluation consisted of literature and vendor data reviews and no experiments were performed. A list of the unit operations reviewed, along with estimated decontamination factors (DFs) for both iodine and ammonium are shown in the table below. With the exception of the Peroxide Decomposer, reasonable estimations of the decontamination factors for all operations are provided.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refractory Cystobiliary Fistula Secondary to Percutaneous Treatment of Hydatid Cyst: Treatment with N-Butyl 2-Cyanoacrylate Embolization

A 27-year-old female with a type 2 hydatid cystic lesion in the liver according to the Gharbi classification (CE 3A according to the WHO classification) was referred for percutaneous treatment after albendazole treatment for 1 year. A catheterization technique was performed but hypertonic saline and alcohol were not given into the cavity due to cystobiliary leakage. During the 4-month follow-up period, sequential cavitography revealed biliary fistula, and bile-stained drainage had not been ceased despite the sphincterotomy, nasobiliary drainage catheter, and plastic stent. Since the patient refused to surgery, we embolized the biliary fistula using N-butyl 2-cyanoacrylate for the first time in the literature. At the 3-month follow-up, the patient's course was uneventful and ultrasound, multidetector-row CT, and MRI examinations revealed no collection in or adjacent to the cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Treatment of an Infected Aneurysmal Sac Secondary to Aortoesophageal Fistula with a History of Stent-Graft Treatment for Thoracic Aortic Aneurysm

A 68-year-old man who was subjected to stent-grafting of a descending thoracic aortic aneurysm (TAA) 4 months previously was admitted to our hospital with constitutional symptoms, including high fever, sweating, nausea, vomiting, weight loss, and backache. An infected aneurysmal sac was suspected based on computed tomography (CT) findings, and an aortoesophageal fistula (AEF) was identified during esophagoscopy. CT-guided aspiration was performed using a 20-G Chiba needle, confirming the presence of infection. For treatment of the infected aneurysmal sac, CT-guided percutaneous catheter drainage in a prone position was performed under general anesthesia with left endobronchial intubation. Drainage catheter insertion was successfully performed using the Seldinger technique, which is not a standard treatment of an infected aneurysmal sac. Improvement in the patient's clinical condition was observed at follow-ups, and CT showed total regression of the collection in the aneurysmal sac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗