Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TRAJECTORY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Properties of the optimal trajectories for coplanar, aeroassisted orbital transfer

The optimization of trajectories for coplanar, aeroassisted orbital transfer (AOT) from a high earth orbit (HEO) to a low earth orbit (LEO) is examined. In particular, HEO can be a geosynchronous earth orbit (GEO). During the atmospheric pass, the trajectory is controlled via the lift coefficient in such a way that the total characteristic velocity is minimized. First, an ideal optimal trajectory is determined analytically for lift coefficient unbounded. This trajectory is called a grazing trajectory. For the grazing trajectory, the lift coefficient varies in such a way that the lift, the contrifugal force due to the earth's curvature, the weight, and the Coriolis force due to the earth's rotation are in static balance. Also, the grazing trajectory minimizes the total characteristic velocity and simultaneously nearly minimizes the peak values of the altitude drop, dynamic pressure, and heating rate. Next, starting from the grazing trajectory results, a real optimal trajectory is determined numerically for the lift coefficient bounded from both below and above. This trajectory is characterized by atmospheric penetration with the smallest possible entry angle, followed by flight at the lift coefficient lower bound. The real optimal trajectory minimizes the total characteristic velocity and simultaneously nearly minimizes the peak values of the altitude drop, the dynamic pressure, and the heating rate.

Miele, A.↗

A Distributed Trajectory-Oriented Approach to Managing Traffic Complexity

In order to handle the expected increase in air traffic volume, the next generation air transportation system is moving towards a distributed control architecture, in which ground-based service providers such as controllers and traffic managers and air-based users such as pilots share responsibility for aircraft trajectory generation and management. While its architecture becomes more distributed, the goal of the Air Traffic Management (ATM) system remains to achieve objectives such as maintaining safety and efficiency. It is, therefore, critical to design appropriate control elements to ensure that aircraft and groundbased actions result in achieving these objectives without unduly restricting user-preferred trajectories. This paper presents a trajectory-oriented approach containing two such elements. One is a trajectory flexibility preservation function, by which aircraft plan their trajectories to preserve flexibility to accommodate unforeseen events. And the other is a trajectory constraint minimization function by which ground-based agents, in collaboration with air-based agents, impose just-enough restrictions on trajectories to achieve ATM objectives, such as separation assurance and flow management. The underlying hypothesis is that preserving trajectory flexibility of each individual aircraft naturally achieves the aggregate objective of avoiding excessive traffic complexity, and that trajectory flexibility is increased by minimizing constraints without jeopardizing the intended ATM objectives. The paper presents conceptually how the two functions operate in a distributed control architecture that includes self separation. The paper illustrates the concept through hypothetical scenarios involving conflict resolution and flow management. It presents a functional analysis of the interaction and information flow between the functions. It also presents an analytical framework for defining metrics and developing methods to preserve trajectory flexibility and minimize its constraints. In this framework flexibility is defined in terms of robustness and adaptability to disturbances and the impact of constraints is illustrated through analysis of a trajectory solution space with limited degrees of freedom and in simple constraint situations involving meeting multiple times of arrival and resolving a conflict.

Idris, Husni↗

Aerocapture Trajectory Design for Uranus Orbiter

Introduction: The recently released National Academies Planetary Science and Astrobiology Decadal Survey 2023-2032 [1] identified the Ice Giants as the top priority science destination. While the survey acknowledged the potential for either a Uranus Orbiter and Probe (UOP) mission or a Neptune-Triton Odyssey mission, it ultimately identified the former as the highest priority new flagship mission. UOP missions calls for a launch window of opportunity between 2031-2038 with 12-15 year interplanetary cruise time along with a fully-propulsive Uranus Orbit Insertion burn on the order of a few km/s. However, a mission to Uranus with the same science payload could utilize aerocapture for orbit insertion to achieve both a significant reduction in the interplanetary cruise time and reduction in propulsive burn costs. Why Aerocapture: Aerocapture is a promising propellant and time-saving orbital insertion technique for planetary destinations with an atmosphere. Although not flight-proven, previous aerocapture systems studies in the literature have demonstrated both the validity and robustness of the technique at various planetary destinations. With respect to the Ice Giant planets, Neptune has seen more of the analysis in the literature. For science missions at Neptune, aerocapture can enable 1.4 times more delivered mass to orbit than an all-propulsive mission for the same launch vehicle while reducing interplanetary cruise times by more than 3 years [2] Additionally with modern guidance and control, Neptune aerocapture with blunt-body aeroshells is realizable [3][4]. There are limited papers in the literature investigating Uranus aerocapture with those available providing a preliminary feasibility assessment [5]. Consequently, the two-year funded NASA Space Technology Mission Directorate (STMD)-funded project, titled Aerocapture System as an Enabling Technology for Ice Giants Missions, aims to mature the analysis and technology state of Uranus aerocapture. Trajectory Design: This paper presents the current state of the trajectory design in support of the new aerocapture project. The project design philosophy is inspired from recent Neptune aerocapture studies, which employed modern guidance and control, in the sense that blunt-body aeroshells are analyzed. An assessment of the theoretical flight path angle corridor width is conducted for a range of ballistic coefficients and lift-to-drag ratios for both Space Launch System and Falcon Heavy Launch Vehicle interplanetary trajectory solutions. The results from the corridor width assessment provide an assessment of the aerocapture design-space and qualitative metrics on trajectory design considerations. The Program to Optimize Simulated Trajectories II (POST2) is utilized to run Monte Carlo simulations of Uranus aerocapture three-degree-of-freedom bank angle modulated trajectories using a closed-loop numerical-predictor corrector guidance algorithm. UranusGRAM 2021 is utilized as the atmospheric model [6]. A Uranus-developed aerodatabase, originally derived from Mars Science Laboratory (MSL), is utilized to provide vehicle aerodynamics over a wide range of hypersonic flow regimes. A MSL-derived 70 deg 4.5m diameter sphere-cone aeroshell that houses the UOP payload mass is assumed. Robustness testing and performance analysis is conducted, including the assessment of entry state errors, atmosphere density variations, and aerodynamic dispersions. Post-aerocapture Delta-V and aerothermal statistics are formulated into propellant mass and TPS requirements. The results presented in the paper will demonstrate the trajectory viability of Uranus aerocapture. Preliminary Results: Preliminary trajectory design results indicates successful Uranus aerocapture with a blunt-body aeroshell housing the same payload mass as the UOP mission from an Earth-to-Uranus interplanetary trajectory arriving in less than 7 years. From this interplanetary trajectory, aerocapture provides an orbit insertion Delta-V capability of 6.9 km/s requiring less than 300 m/s for post-aerocapture correction burns (15% of wet mass allocated to propellant). To put this into perspective, the UOP study utilized an Earth-to-Uranus trajectory that arrives in 13 years and requires more than 1000 m/s for fully-propulsive orbit insertion (40% of wet mass allocated to propellant). Achieving the same 6.9 km/s Delta-V capability fully-propulsively is mass prohibitive (97% of wet mass allocated to propellant). Nevertheless, aerocapture has the potential to reduce interplanetary transit times to Uranus by half while delivering the same payload mass to orbit in a reduced propellant mass footprint.

Rohan Deshmukh↗

A Method to Estimate Mean Position, Motion Magnitude, Motion Correlation, and Trajectory of a Tumor From Cone-Beam CT Projections for Image-Guided Radiotherapy

Purpose: To develop a probability-based method for estimating the mean position, motion magnitude, and trajectory of a tumor using cone-beam CT (CBCT) projections. Method and Materials: CBCT acquisition was simulated for more than 80 hours of patient-measured trajectories for thoracic/abdominal tumors and prostate. The trajectories were divided into 60-second segments for which CBCT was simulated by projecting the tumor position onto a rotating imager. Tumor (surrogate) visibility on all projections was assumed. The mean and standard deviation of the tumor position and motion correlation along the three axes were determined with maximum likelihood estimation based on the projection data, assuming a Gaussian spatial distribution. The unknown position component along the imager axis was approximated by its expectation value, determined by the Gaussian distribution. Transformation of the resulting three-dimensional position to patient coordinates provided the estimated trajectory. Two trajectories were experimentally investigated by CBCT acquisition of a phantom. Results: The root-mean-square error of the estimated mean position was 0.05 mm. The root-mean-square error of the trajectories was <1 mm in 99.1% of the thorax/abdomen cases and in 99.7% of the prostate cases. The experimental trajectory estimation agreed with the actual phantom trajectory within 0.44 mm in any direction. Clinical applicability was demonstrated by estimating the tumor trajectory for a pancreas cancer case. Conclusions: A method for estimation of mean position, motion magnitude, and trajectory of a tumor from CBCT projections has been developed. The accuracy was typically much better than 1 mm. The method is applicable to motion-inclusive, respiratory-gated, and tumor-tracking radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion

Purpose: To develop and evaluate accurate and objective on-line patient setup based on a novel semiautomatic technique in which three-dimensional marker trajectories were estimated from two-dimensional cone-beam computed tomography (CBCT) projections. Methods and Materials: Seven treatment courses of stereotactic body radiotherapy for liver tumors were delivered in 21 fractions in total to 6 patients by a linear accelerator. Each patient had two to three gold markers implanted close to the tumors. Before treatment, a CBCT scan with approximately 675 two-dimensional projections was acquired during a full gantry rotation. The marker positions were segmented in each projection. From this, the three-dimensional marker trajectories were estimated using a probability based method. The required couch shifts for patient setup were calculated from the mean marker positions along the trajectories. A motion phantom moving with known tumor trajectories was used to examine the accuracy of the method. Trajectory-based setup was retrospectively used off-line for the first five treatment courses (15 fractions) and on-line for the last two treatment courses (6 fractions). Automatic marker segmentation was compared with manual segmentation. The trajectory-based setup was compared with setup based on conventional CBCT guidance on the markers (first 15 fractions). Results: Phantom measurements showed that trajectory-based estimation of the mean marker position was accurate within 0.3 mm. The on-line trajectory-based patient setup was performed within approximately 5 minutes. The automatic marker segmentation agreed with manual segmentation within 0.36 {+-} 0.50 pixels (mean {+-} SD; pixel size, 0.26 mm in isocenter). The accuracy of conventional volumetric CBCT guidance was compromised by motion smearing ({<=}21 mm) that induced an absolute three-dimensional setup error of 1.6 {+-} 0.9 mm (maximum, 3.2) relative to trajectory-based setup. Conclusions: The first on-line clinical use of trajectory estimation from CBCT projections for precise setup in stereotactic body radiotherapy was demonstrated. Uncertainty in the conventional CBCT-based setup procedure was eliminated with the new method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRF-07: Non-Circular Scanning Trajectories with Varian Developer Mode

Purpose: Cone-beam CT (CBCT) in image-guide radiation therapy (IGRT) typicallyacquires scan data via the circular trajectory of the linearaccelerator's (linac) gantry rotation. Though this lends itself toanalytic reconstruction algorithms like FDK, iterative reconstructionalgorithms allow for a broader range of scanning trajectories. Weimplemented a non-circular scanning trajectory with Varian's TrueBeamDeveloper Mode and performed some preliminary reconstructions toverify the geometry. Methods: We used TrueBeam Developer Mode to program a new scanning trajectorythat increases the field of view (FOV) along the gantry rotation axiswithout moving the patient. This trajectory consisted of moving thegantry in a circle, then translating the source and detector along theaxial direction before acquiring another circular scan 19 cm away fromthe first. The linear portion of the trajectory includes an additional4.5 cm above and below the axial planes of the source's circularrotation. We scanned a calibration phantom consisting of a lucite tubewith a spiral pattern of CT spots and used the maximum-likelihoodalgorithm to iteratively reconstruct the CBCT volume. Results: With the TrueBeam trajectory definition, we acquired projection dataof the calibration phantom using the previously described trajectory.We obtained a scan of the treatment couch for log normalization byscanning with the same trajectory but without the phantom present.Using the nominal geometric parameters reported in the projectionheaders with our iterative reconstruction algorithm, we obtained acorrect reconstruction of the calibration phantom. Conclusion: The ability to implement new scanning trajectories with the TrueBeamDeveloper Mode enables us access to a new parameter space for imagingwith CBCT for IGRT. Previous simulations and simple dual circle scanshave shown iterative reconstruction with non-circular trajectories canincrease the axial FOV with CBCT. Use of Developer Mode allowsexperimentally testing these and other new scanning trajectories. Support was provided in part by the University of Chicago Research Computing Center, Varian Medical Systems, and NIH Grants 1RO1CA120540, T32EB002103, S10 RR021039 and P30 CA14599. The contents of this work are solely the responsibility of the authors and do not necessarily represent the official views of the supporting organizations.

60 APPLIED LIFE SCIENCES↗

Calculating tumor trajectory and dose-of-the-day using cone-beam CT projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. The authors developed and validated a method which uses these projections to determine the trajectory of and dose to highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, the trajectory of which mimicked a lung tumor with high amplitude (up to 2.5 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each CBCT projection, and a Gaussian probability density function for the absolute BB position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two modifications of the trajectory reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation (Phase), and second, using the Monte Carlo (MC) method to sample the estimated Gaussian tumor position distribution. The accuracies of the proposed methods were evaluated by comparing the known and calculated BB trajectories in phantom-simulated clinical scenarios using abdominal tumor volumes. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square trajectory errors averaged 3.8% ± 1.1% of the marker amplitude. Dosimetric calculations using Phase methods were more accurate, with mean absolute error less than 0.5%, and with error less than 1% in the highest-noise trajectory. MC-based trajectories prevent the overestimation of dose, but when viewed in an absolute sense, add a small amount of dosimetric error (<0.1%). Conclusions: Marker trajectory and target dose-of-the-day were accurately calculated using CBCT projections. This technique provides a method to evaluate highly mobile tumors using ordinary CBCT data, and could facilitate better strategies to mitigate or compensate for motion during stereotactic body radiotherapy.

60 APPLIED LIFE SCIENCES↗

Optimization and guidance of penetration landing trajectories in a windshear

The optimization and guidance of penetration landing trajectories in a windshear are considered. It is assumed that the aircraft is controlled by the angle of attack and the power setting. For the optimal trajectory, the performance index being minimized measures the deviation of the flight trajectory from the nominal trajectory. In turn, the nominal trajectory includes two parts: the approach part (nominal glide slope constant) and the flare part (nominal glide slope varying linearly with the horizontal distance). Numerical results show that the optimal trajectory deviates somewhat from the nominal trajectory in the shear region. A guidance scheme is developed to approximate the optimal trajectory. The angle of attack is determined by the windshear intensity, the absolute path inclination, and the glide slope angle, while the power setting is determined by the windshear intensity and the velocity. Numerical results indicate that the guidance trajectory is close to the optimal trajectory.

Miele, A.↗

Trajectory optimization for an asymmetric launch vehicle

A numerical optimization technique is used to fully automate the trajectory design process for an symmetric configuration of the proposed Advanced Launch System (ALS). The objective of the ALS trajectory design process is the maximization of the vehicle mass when it reaches the desired orbit. The trajectories used were based on a simple shape that could be described by a small set of parameters. The use of a simple trajectory model can significantly reduce the computation time required for trajectory optimization. A predictive simulation was developed to determine the on-orbit mass given an initial vehicle state, wind information, and a set of trajectory parameters. This simulation utilizes an idealized control system to speed computation by increasing the integration time step. The conjugate gradient method is used for the numerical optimization of on-orbit mass. The method requires only the evaluation of the on-orbit mass function using the predictive simulation, and the gradient of the on-orbit mass function with respect to the trajectory parameters. The gradient is approximated with finite differencing. Prelaunch trajectory designs were carried out using the optimization procedure. The predictive simulation is used in flight to redesign the trajectory to account for trajectory deviations produced by off-nominal conditions, e.g., stronger than expected head winds.

Sullivan, Jeanne Marie↗

Method and Apparatus for Generating Flight-Optimizing Trajectories

An apparatus for generating flight-optimizing trajectories for a first aircraft includes a receiver capable of receiving second trajectory information associated with at least one second aircraft. The apparatus also includes a traffic aware planner (TAP) module operably connected to the receiver to receive the second trajectory information. The apparatus also includes at least one internal input device on board the first aircraft to receive first trajectory information associated with the first aircraft and a TAP application capable of calculating an optimal trajectory for the first aircraft based at least on the first trajectory information and the second trajectory information. The optimal trajectory at least avoids conflicts between the first trajectory information and the second trajectory information.

Ballin, Mark G.↗

An Efficient Universal Trajectory Language

The Efficient Universal Trajectory Language (EUTL) is a language for specifying and representing trajectories for Air Traffic Management (ATM) concepts such as Trajectory-Based Operations (TBO). In these concepts, the communication of a trajectory between an aircraft and ground automation is fundamental. Historically, this trajectory exchange has not been done, leading to trajectory definitions that have been centered around particular application domains and, therefore, are not well suited for TBO applications. The EUTL trajectory language has been defined in the Prototype Verification System (PVS) formal specification language, which provides an operational semantics for the EUTL language. The hope is that EUTL will provide a foundation for mathematically verified algorithms that manipulate trajectories. Additionally, the EUTL language provides well-defined methods to unambiguously determine position and velocity information between the reported trajectory points. In this paper, we present the EUTL trajectory language in mathematical detail.

Hagen, George E.↗

Comparison of measured and computed radial trajectories of plasma focus devices UMDPF1 and UMDPF0

In published literature, there has been scant data on radial trajectory of the plasma focus and no comparison of computed with measured radial trajectory. This paper provides the first such comparative study. We compute the trajectories of the inward-moving radial shock and magnetic piston of UMDPF1 plasma focus and compare these with measured data taken from a streak photograph. The comparison shows agreement with the measured radial trajectory in terms of average speeds and general shape of trajectory. This paper also presents the measured trajectory of the radially compressing piston in another machine, the UMDPF0 plasma focus, confirming that the computed radial trajectory also shows similar general agreement. Features of divergence between the computed and measured trajectories, towards the end of the radial compression, are discussed. From the measured radial trajectories, an inference is made that the neutron yield mechanism could not be thermonuclear. A second inference is made regarding the speeds of axial post-pinch shocks, which are recently considered as a useful tool for damage testing of fusion-related wall materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-F-17A-05: Calculating Tumor Trajectory and Dose-Of-The-Day for Highly Mobile Tumors Using Cone-Beam CT Projections

Purpose: Cone-beam CT (CBCT) projection images provide anatomical data in real-time over several respiratory cycles, forming a comprehensive picture of tumor movement. We developed a method using these projections to determine the trajectory and dose of highly mobile tumors during each fraction of treatment. Methods: CBCT images of a respiration phantom were acquired, where the trajectory mimicked a lung tumor with high amplitude (2.4 cm) and hysteresis. A template-matching algorithm was used to identify the location of a steel BB in each projection. A Gaussian probability density function for tumor position was calculated which best fit the observed trajectory of the BB in the imager geometry. Two methods to improve the accuracy of tumor track reconstruction were investigated: first, using respiratory phase information to refine the trajectory estimation, and second, using the Monte Carlo method to sample the estimated Gaussian tumor position distribution. 15 clinically-drawn abdominal/lung CTV volumes were used to evaluate the accuracy of the proposed methods by comparing the known and calculated BB trajectories. Results: With all methods, the mean position of the BB was determined with accuracy better than 0.1 mm, and root-mean-square (RMS) trajectory errors were lower than 5% of marker amplitude. Use of respiratory phase information decreased RMS errors by 30%, and decreased the fraction of large errors (>3 mm) by half. Mean dose to the clinical volumes was calculated with an average error of 0.1% and average absolute error of 0.3%. Dosimetric parameters D90/D95 were determined within 0.5% of maximum dose. Monte-Carlo sampling increased RMS trajectory and dosimetric errors slightly, but prevented over-estimation of dose in trajectories with high noise. Conclusions: Tumor trajectory and dose-of-the-day were accurately calculated using CBCT projections. This technique provides a widely-available method to evaluate highly-mobile tumors, and could facilitate better strategies to mitigate or compensate for motion during SBRT.

60 APPLIED LIFE SCIENCES↗

Copernicus-LinCov (COPCOV) Software Integration in Support of Robust Trajectory Optimization

Robust trajectory optimization is the process of optimizing a trajectory while accounting for system uncertainty due to a variety of potential error sources. This work highlights the development and features of a novel tool known as CopCov to support robust trajectory optimization efforts. CopCov acts as an interface between Copernicus, a generalized trajectory design and optimization tool, and LinCov, a linear covariance analysis tool. By having a direct interface between these two software packages, Copernicus can receive covariance information from LinCov through a direct feedback loop, thus enabling optimization of a trajectory that is robust to trajectory dispersions and navigation errors. This paper details the architecture of CopCov and its flexibility to operate under varying configurations, including with both tools running locally or alternatively with the tools communicating via a remote connection. Additionally, the CopCov tool is demonstrated on a simple Hohmann transfer reference trajectory with varying numbers of Trajectory Correction Maneuvers (TCMs) and varying problem formulations. This example scenario is used to highlight how the inclusion of the CopCov interface affects burn placement of both major burns and minor burns (i.e., TCMs) in the optimized solution. Results are compared against analytical solutions and against a Genetic Algorithm (GA) optimizer for independent verification and validation.

Copernicus↗

Machine Learning Analysis of Direct Dynamics Trajectory Outcomes for Thermal Deazetization of 2,3-Diazabicyclo[2.2.1]hept-2-ene

Experimentally, the thermal gas-phase deazetization of 2,3-diazabicyclo[2.2.1]hept-2-ene (1) results in the loss of N2 and the formation of bicyclo products 3 (exo) and 4 (endo) in a nonstatistical ratio, with preference for the exo product. Here, we report unrestricted M06-2X quasiclassical trajectories initialized from the concerted N2 ejection transition state that were able to replicate the experimental preference to form 3. We found that the 3:4 ratio results from the relative amounts of very fast (ballistic) exotype trajectories versus trajectories that lead to the 1,3-diradical intermediate 2. These quasiclassical trajectories provided a set of transition-state vibrational, velocity, momenta, and geometric features for the machine learning analysis. Additionally, a selection of popular supervised classification algorithms (e.g., random forest) provided poor prediction of trajectory outcomes based on only transition-state vibrational quanta and energy features. However, these machine learning models provided more accurate predictions using atomic velocities and atomic positions, attaining ~70% accuracy using initial conditions and between 85 and 95% accuracy at later reaction time steps. This increased accuracy allowed the feature importance analysis to reveal that, at the later-time analysis, the methylene bridge out-of-plane bending is correlated with trajectory outcomes for the formation of either the exo product or toward the diradical intermediate. Possible reasons for the struggle of machine learning algorithms to classify trajectories based on transition-state features is the heavily overlapping feature values, the finite but very large possible vibrational mode combinations, and the possibility of chaos as trajectories propagate. We examined this chaos by comparing a set of nearly identical trajectories that differed by only a very small scaling of the kinetic energies resulting from the transition-state reaction coordinate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quality of life trajectories during the first three years after diagnosis of breast cancer: the NEON-BC study

Abstract Background We aimed to identify and characterize quality of life trajectories up to 3 years after breast cancer diagnosis. Methods A total of 460 patients were evaluated at baseline (before treatments), and after 1- and 3-years. Patient-reported outcomes, including quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30, QLQ-C30), anxiety, depression and sleep quality, were assessed in all evaluations. Model-based clustering was used to identify quality of life trajectories. Results We identified four trajectories without intersection during 3 years. The two trajectories characterized by better quality of life depicted relatively stable scores; in the other trajectories, quality of life worsened until 1 year, though in one of them the score at 3 years improved. Sociodemographic and clinical characteristics at baseline did not differ between trajectories, except for mastectomy, which was higher in the worst trajectory. Anxiety, depression and poor sleep quality increased from the best to the worst trajectory. Conclusions The type of surgery and the variation of other patient-reported outcomes were associated with the course of quality of life over 3 years. More research to understand the heterogeneity of individual trajectories within these major patterns of variation is needed.

Lopes-Conceição, Luisa↗

Extraction of tumor motion trajectories using PICCS-4DCBCT: A validation study

Purpose: As a counterpart of 4DCT in the treatment planning stage of radiotherapy treatment, 4D cone beam computed tomography (4DCBCT) method has been proposed to verify tumor motion trajectories before radiation therapy treatment delivery. Besides 4DCBCT acquisition using slower gantry rotation speed or multiple rotations, a new method using the prior image constrained compressed sensing (PICCS) image reconstruction method and the standard 1-min data acquisition were proposed. In this paper, the PICCS-4DCBCT method was combined with deformable registration to validate its capability in motion trajectory extraction using physical phantom data, simulated human subject data from 4DCT and in vivo human subject data. Methods: Two methods were used to validate PICCS-4DCBCT for the purpose of respiratory motion delineation. The standard 1-min gantry rotation Cone Beam CT acquisition was used for both methods. In the first method, 4DCBCT projection data of a physical motion phantom were acquired using an on-board CBCT acquisition system (Varian Medical Systems, Palo Alto, CA). Using a deformable registration method, the object motion trajectories were extracted from both FBP and PICCS reconstructed 4DCBCT images, and compared against the programmed motion trajectories. In the second method, using a clinical 4DCT dataset, Cone Beam CT projections were simulated by forward projection. Using a deformable registration method, the tumor motion trajectories were extracted from the reconstructed 4DCT and PICCS-4DCBCT images. The performance of PICCS-4DCBCT is assessed against the 4DCT ground truth. The breathing period was varied in the simulation to study its effect on motion extraction. For both validation methods, the root mean square error (RMSE) and the maximum of the errors (MaxE) were used to quantify the accuracy of the extracted motion trajectories. After the validation, a clinical dataset was used to demonstrate the motion delineation capability of PICCS-4DCBCT for human subjects. Results: In both validation studies, the RMSEs of the extracted motion trajectories from PICCS-4DCBCT images are less than 0.7 mm, and their MaxEs are less than 1 mm, for all three directions. In comparison, FBP-4DCBCT shows considerably larger RMSEs in the physical phantom based validation. PICCS-4DCBCT also shows insensitivity to the breathing period in the 4DCT based validation. For the in vivo human subject study, high quality 3D motion trajectory of the tumor was obtained from PICCS-4DCBCT images and showed consistency with visual observation. Conclusions: These results demonstrate accurate delineation of tumor motion trajectory can be achieved using PICCS-4DCBCT and the standard 1-min data acquisition.

61 RADIATION PROTECTION AND DOSIMETRY↗

Curvature Based Analysis to Identify and Categorize Trajectory Segments

Since the attacks carried out against the United States on September 11, 2001, which involved the commandeering of commercial aircraft, interest has increased in performing trajectory analysis of vehicle types not constrained by roadways or railways, i.e., aircraft and watercraft. Anomalous trajectories need to be automatically identified along with other trajectories of interest to flag them for further investigation. There is also interest in analyzing trajectories without a focus on anomaly detection. Various approaches to analyzing these trajectories have been undertaken with useful results to date. In this research, we seek to augment trajectory analysis by carrying out analysis of the trajectory curvature along with other parameters, including distance and total deflection (change in direction). At each point triplet in the ordered sequence of points, these parameters are computed. Adjacent point triplets with similar values are grouped together to form a higher level of semantic categorization. These categorizations are then analyzed to form a yet higher level of categorization which has more specific semantic meaning. This top level of categorization is then summarized for all trajectories under study, allowing for fast identification of trajectories with various semantic characteristics.

42 ENGINEERING↗