Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIMING APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Integrated circuits with programmable gate timing signal generation for power converters and apparatus comprising the same

An apparatus is disclosed that includes a semiconductor device to control a power converter having two or more power FETs. The semiconductor device includes a gate signal generator configured to produce two or more gate signals able to drive the two or more FETs. The gate signal generator has programmable timing configuration parameters to control operation of the two or more gate signals, wherein the timing configuration parameters are digitally programmed via a memory in the semiconductor device. The memory may be implemented with fuses, other non-volatile memory or volatile memory. The parameters may be fixed or updated during a lifetime of the apparatus. A serial-to-parallel conversion may be used to input the parameters. Optimization methods may be performed to determine parameters considered to be optimal. The apparatus may also include the power converter.

42 ENGINEERING↗

Precision timing measurements for high energy photons

Particle colliders operating at high luminosities present challenging environments for high energy physics event reconstruction and analysis. We discuss how timing information, with a precision on the order of 10 ps, can aid in the reconstruction of physics events under such conditions. We present calorimeter based timing measurements from test beam experiments in which we explore the ultimate timing precision achievable for high energy photons or electrons of 10 GeV and above. Using a prototype calorimeter consisting of a 1.7×1.7×1.7 cm 3 lutetium–yttrium oxyortho-silicate (LYSO) crystal cube, read out by micro-channel plate photomultipliers, we demonstrate a time resolution of 33.5±2.1 ps for an incoming beam energy of 32 GeV. In a second measurement, using a 2.5×2.5×20 cm 3 LYSO crystal placed perpendicularly to the electron beam, we achieve a time resolution of 59±11 ps using a beam energy of 4 GeV. We also present timing measurements made using a shashlik-style calorimeter cell made of LYSO and tungsten plates, and demonstrate that the apparatus achieves a time resolution of 54±5 ps for an incoming beam energy of 32 GeV.

43 PARTICLE ACCELERATORS↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

An experimental modal testing/identification technique for personal computers

A PC-based system for mode shape identification is evaluated. A time-domain modal identification procedure is utilized to identify the mode shapes of a beam apparatus from discrete time-domain measurements. The apparatus includes a cantilevered aluminum beam, four accelerometers, four low-pass filters, and the computer. The method's algorithm is comprised of an identification algorithm: the Eigensystem Realization Algorithm (ERA) and an estimation algorithm called Minimum Model Error (MME). The identification ability of this algorithm is compared with ERA alone, a frequency-response-function technique, and an Euler-Bernoulli beam model. Detection of modal parameters and mode shapes by the PC-based time-domain system is shown to be accurate in an application with an aluminum beam, while mode shapes identified by the frequency-domain technique are not as accurate as predicted. The new method is shown to be significantly less sensitive to noise and poorly excited modes than other leading methods. The results support the use of time-domain identification systems for mode shape prediction.

Roemer, Michael J.↗

Sensing device and method for measuring emission time delay during irradiation of targeted samples utilizing variable phase tracking

An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.

Danielson, J. D. Sheldon↗

Experimental Constraints of the Exotic Shearing of Space-Time

The Holometer program is a search for rst experimental evidence that space-time has quantum structure. The detector consists of a pair of co-located 40-m power-recycled interferometers whose outputs are read out synchronously at 50 MHz, achieving sensitivity to spatiallycorrelated uctuations in dierential position on time scales shorter than the light-crossing time of the instruments. Unlike gravitational wave interferometers, which time-resolve transient geometrical disturbances in the spatial background, the Holometer is searching for a universal, stationary quantization noise of the background itself. This dissertation presents the nal results of the Holometer Phase I search, an experiment congured for sensitivity to exotic coherent shearing uctuations of space-time. Measurements of high-frequency cross-spectra of the interferometer signals obtain sensitivity to spatially-correlated eects far exceeding any previous measurement, in a broad frequency band extending to 7.6 MHz, twice the inverse light-crossing time of the apparatus. This measurement is the statistical aggregation of 2.1 petabytes of 2-byte dierential position measurements obtained over a month-long exposure time. At 3 signicance, it places an upper limit on the coherence scale of spatial shear two orders of magnitude below the Planck length. The result demonstrates the viability of this novel spatially-correlated interferometric detection technique to reach unprecedented sensitivity to coherent deviations of space-time from classicality, opening the door for direct experimental tests of theories of relational quantum gravity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of a four-step HMX kinetic model to an impact-induced fraction ignition problems

There has been a long history of interest in the decomposition kinetics of HMX and HMX-based formulations due to the widespread use of this explosive in high performance systems. The kinetics allow us to predict, or attempt to predict, the behavior of the explosive when subjected to thermal hazard scenarios that lead to ignition via impact, spark, friction or external heat. The latter, commonly referred to as 'cook off', has been widely studied and contemporary kinetic and transport models accurately predict time and location of ignition for simple geometries. However, there has been relatively little attention given to the problem of localized ignition that results from the first three ignition sources of impact, spark and friction. The use of a zero-order single-rate expression describing the exothermic decomposition of explosives dates to the early work of Frank-Kamanetskii in the late 1930s and continued through the 60's and 70's. This expression provides very general qualitative insight, but cannot provide accurate spatial or timing details of slow cook off ignition. In the 70s, Catalano, et al., noted that single step kinetics would not accurately predict time to ignition in the one-dimensional time to explosion apparatus (ODTX). In the early 80s, Tarver and McGuire published their well-known three step kinetic expression that included an endothermic decomposition step. This scheme significantly improved the accuracy of ignition time prediction for the ODTX. However, the Tarver/McGuire model could not produce the internal temperature profiles observed in the small-scale radial experiments nor could it accurately predict the location of ignition. Those factors are suspected to significantly affect the post-ignition behavior and better models were needed. Brill, et al. noted that the enthalpy change due to the beta-delta crystal phase transition was similar to the assumed endothermic decomposition step in the Tarver/McGuire model. Henson, et al., deduced the kinetics and thermodynamics of the phase transition, providing Dickson, et al. with the information necessary to develop a four-step model that included a two-step nucleation and growth mechanism for the {beta}-{delta} phase transition. Initially, an irreversible scheme was proposed. That model accurately predicted the spatial and temporal cook off behavior of the small-scale radial experiment under slow heating conditions, but did not accurately capture the endothermic phase transition at a faster heating rate. The current version of the four-step model includes reversibility and accurately describes the small-scale radial experiment over a wide range of heating rates. We have observed impact-induced friction ignition of PBX 9501 with grit embedded between the explosive and the lower anvil surface. Observation was done using an infrared camera looking through the sapphire bottom anvil. Time to ignition and temperature-time behavior were recorded. The time to ignition was approximately 500 microseconds and the temperature was approximately 1000 K. The four step reversible kinetic scheme was previously validated for slow cook off scenarios. Our intention was to test the validity for significantly faster hot-spot processes, such as the impact-induced grit friction process studied here. We found the model predicted the ignition time within experimental error. There are caveats to consider when evaluating the agreement. The primary input to the model was friction work over an area computed by a stress analysis. The work rate itself, and the relative velocity of the grit and substrate both have a strong dependence on the initial position of the grit. Any errors in the analysis or the initial grit position would affect the model results. At this time, we do not know the sensitivity to these issues. However, the good agreement does suggest the four step kinetic scheme may have universal applicability for HMX systems.

36 MATERIALS SCIENCE↗

A kiloelectron-volt ultrafast electron micro-diffraction apparatus using low emittance semiconductor photocathodes

We report the design and performance of a time-resolved electron diffraction apparatus capable of producing intense bunches with simultaneously single digit micrometer probe size, long coherence length, and 200 fs rms time resolution. We measure the 5d (peak) beam brightness at the sample location in micro-diffraction mode to be 7×1013 A/m2 rad2. To generate high brightness electron bunches, the system employs high efficiency, low emittance semiconductor photocathodes driven with a wavelength near the photoemission threshold at a repetition rate up to 250 kHz. We characterize spatial, temporal, and reciprocal space resolution of the apparatus. We perform proof-of-principle measurements of ultrafast heating in single crystal Au samples and compare experimental results with simulations that account for the effects of multiple scattering.

43 PARTICLE ACCELERATORS↗

Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces

This apparatus distributes dust (typical of the Martian surface) in a uniform fashion on the surface of multiple samples simultaneously. The primary innovation is that the amount of dust deposited on the multiple surfaces can be controlled by the time that the apparatus operates, and each sample will be subject to the same amount of dust deposition. The exact weight of dust that is added per unit of sample area is determined by the use of slides that can be removed sequentially after each dusting.

Hurlbert, Kathryn Miller↗

The effects of reduced oxygen and of carbon monoxide on performance in a mouse pole-jump apparatus

The effects on reaction time and behavior were studied for exposure to reduced oxygen concentrations in the presence and absence of carbon monoxide. Tests were run with Swiss Webster mice in a pole-jump apparatus. The results show that reaction times increase gradually with a decrease in oxygen (O2) to 10 percent O2. Below 10 percent O2 reaction times increase dramatically and performance is degraded almost immediately. At carbon monoxide (CO) concentrations of 500 ppm and reduced O2 levels, reaction times are increased even more. At CO concentrations of 1000 ppm, performance is nearly completely degraded even without reduced oxygen levels.

Cagliostro, D. E.↗

Femtosecond time-resolved impulsive stimulated Raman spectroscopy using sub-7-fs pulses: Apparatus and applications

We describe details of the setup for time-resolved impulsive stimulated Raman spectroscopy (TR-ISRS). In this method, snapshot molecular vibrational spectra of the photoreaction transients are captured via time-domain Raman probing using ultrashort pulses. Our instrument features transform-limited sub-7-fs pulses to impulsively excite and probe coherent nuclear wavepacket motions, allowing us to observe vibrational fingerprints of transient species from the terahertz to 3000-cm{sup −1} region with high sensitivity. Key optical components for the best spectroscopic performance are discussed. The TR-ISRS measurements for the excited states of diphenylacetylene in cyclohexane are demonstrated, highlighting the capability of our setup to track femtosecond dynamics of all the Raman-active fundamental molecular vibrations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and apparatus for radiation detection based on time-of-flight within optical fibers

A radiation detection system using time of flight (TOF) information within multiple optical fiber complexes coupled with a scintillating material at intersections of repeatedly crossing over shape. Light detectors are placed at the ends of each fiber to detect scintillation events. A timing processor is collecting light detector signal to compute TOF difference and estimate the location and strength of radioactivity. The system is scalable in one dimension, capable of being shaped or curved, and customizable in terms of special resolution and sensitivity. The system is suitable for long range and coarse radiation detection.

Lee, Seung Jae↗

Sensitive Mass Spectrometer for Time-Resolved Gas-Phase Chemistry Studies at High Pressures

Here, we report the construction of a new experimental apparatus for direct time-resolved probing of high-pressure gas-phase chemical reactions by photoionization mass spectrometry. The apparatus uses a laser photolysis slow-flow reactor, capable of operating at P = 0.3 — 100 bar and T = 300 — 1000 K. In this report, we initiate reactions in homogeneous gas mixtures by the photolysis of appropriate radical precursor using laser pulses at repetition rates of 1 — 10 Hz. The reacting mixture is continuously sampled into a vacuum chamber, ionized by VUV photons from laboratory-based discharge lamps or from a synchrotron beamline, and analyzed by a custom-designed mass spectrometer. Soft near-threshold ionization by tunable synchrotron radiation enables spectroscopic quantification of many key intermediates and products of chemical reactions. A novel ionization scheme in the high-density region of the sample gas jet increases the experimental sensitivity 100-fold, compared with existing instruments, without compromising mass resolution. A 40-kHz pulsed reflectron time-of-flight mass spectrometer in the orthogonal acceleration geometry achieves simultaneous detection of all ionized species with 25-μs time resolution. We show the power of this apparatus by investigating the ethyl radical oxidation reaction using very dilute (<10 12 molecules • cm -3 ) ethyl concentrations at pressures up to 25 bar.

47 OTHER INSTRUMENTATION↗

Apparatus and method to measure semiconductor optical absorption using microwave charge sensing

A time-resolved microwave reflectance apparatus comprises a pulsed or modulated optical source that irradiates a semiconductor sample with an excitation pump beam, a microwave oscillator that irradiates the sample with a continuous beam of microwaves, and a microwave detector that detects the microwaves reflected by the sample. Therefore, charge detection, rather than conventional absorption measurements (that detect the loss of photons), can be used to extract the absorption coefficient and band edge of a semiconductor material.

Shaner, Eric A.↗

Time-reversed nonlinear acoustics for downhole pressure measurements

Apparatus (10) and methods for combining time reversal and elastic nonlinearity of formation materials for qualtitatively probing for over-pressured regions down hole in advance of a well drilling bit, to determine the distance to the over-pressured region, and for accurately measuring pore pressure downhole in a formation, are described. Classical and reciprocal time reversal methods may be utilized to achieve these measurements.

Johnson, Paul A.↗

Tests of Mach's Principle With a Mechanical Oscillator

James F. Woodward has made a prediction, based on Sciama's formulation of Mach's Principle in the framework of general relativity, that in the presence of an energy flow the inertial mass of an object may undergo sizable variations, changing as the second time derivative of the energy. We describe an attempt to test for the predicted effect with a charging capacitor, using a technique that does not require an unbalanced force or any local violation of Newton s 3rd law of motion. We attempt to observe: (1) the gravitational effect of the varying mass and (2) the effect of the mass variation on a driven harmonic oscillator with the charging capacitor as the oscillating mass. We report on the predicted effect, the design and implementation of the measurement apparatus, and initial experience with the apparatus. At this time, however, we will not report on observations of the presence or absence of the Woodward effect.

Millis, Marc G.↗

Apparatus for Precise Indium-Bump Bonding of Microchips

An improved apparatus has been designed and built for use in precise positioning and pressing of a microchip onto a substrate (which could, optionally, be another microchip) for the purpose of indium-bump bonding. The apparatus (see figure) includes the following: A stereomicroscope, A stage for precise positioning of the microchip in rotation angle (theta) about the nominally vertical pressing axis and in translation along two nominally horizontal coordinate axes (x and y), and An actuator system that causes a bonding tip to press the microchip against the substrate with a precisely controlled force. In operation, the microscope and the stage are used to position the microchip under the bonding tip and to align the indium bumps on the chip and the substrate, then the actuator system is used to apply a prescribed bonding force for a prescribed time. The improved apparatus supplants a partly similar prior apparatus that operated with less precision and repeatability, producing inconsistent and unreliable bonds. Results of the use of the prior apparatus included broken microchips, uneven bonds, and bonds characterized, variously, by overcompression or undercompression. In that apparatus, the bonding force was generated and controlled by use of a micrometer head positioned over the center of a spring-loaded scale, and the force was applied to the microchip via the scale, which was equipped for digital readout of the force. The inconsistency of results was attributed to the following causes: It was not possible to control the bonding force with sufficient precision or repeatability. Particularly troublesome was the inability to control the force at levels less than the weight of 150 g. Excessive compliance in the spring-loaded scale, combined with deviations from parallelarity of the substrate and bonding-tip surfaces, gave rise to nonuniformity in the pressure applied to the microchip, thereby generating excessive stresses and deformations in the microchip. In the improved apparatus, the bonding tip and the components that hold the substrate and the microchip are more rigid and precise than in the prior apparatus, so as to ensure less deviation from parallelarity of the bonding-tip and substrate surfaces, thereby ensuring more nearly uniform distribution of bonding force over the area of the microchip. The bonding force is now applied through, and measured by, a load cell that makes it possible to exert finer control over the force. The force can be set at any value between 0 and the weight of 800 g in increments of 0.2 g.

Wild, Larry↗

HOT BOX TESTING OF BUILDING ENVELOPE ASSEMBLIES; A SIMPLIFIED PROCEDURE FOR ESTIMATION OF MINIMUM TIME OF THE TEST

Cost of performing hot-box experiments on building envelope assemblies is relatively high. That is why proper estimation of the minimum amount of time necessary to achieve required test accuracy is critical to all hot-box operators. In this paper, two methods are proposed for determining wall specimen time constants, for the hot-box apparatus testing. The requirements published in ASTM C1363-05 Standard Test Method for the Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus, concerning determination of the time to reach the steady state of heat flow are discussed. One method requires numerical calculations of the response factors with subsequent determination of time constants. The second method makes use of the approximate relation between the time constant and the product of resistance, capacity, and a structure factor. Both methods may serve for the optimization of the minimum test time during hot-box experiments.

36 MATERIALS SCIENCE↗