Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Modern Radar Techniques for Geophysical Applications: Two Examples

The last decade of the evolution of radar was heavily influenced by the rapid increase in the information processing capabilities. Advances in solid state radio HF devices, digital technology, computing architectures and software offered the designers to develop very efficient radars. In designing modern radars the emphasis goes towards the simplification of the system hardware, reduction of overall power, which is compensated by coding and real time signal processing techniques. Radars are commonly employed in geophysical radio soundings like probing the ionosphere; stratosphere-mesosphere measurement, weather forecast, GPR and radio-glaciology etc. In the laboratorio di Geofisica Ambientale of the Istituto Nazionale di Geofisica e Vulcanologia (INGV), Rome, Italy, we developed two pulse compression radars. The first is a HF radar called AIS-INGV; Advanced Ionospheric Sounder designed both for the purpose of research and for routine service of the HF radio wave propagation forecast. The second is a VHF radar called GLACIORADAR, which will be substituting the high power envelope radar used by the Italian Glaciological group. This will be employed in studying the sub glacial structures of Antarctica, giving information about layering, the bed rock and sub glacial lakes if present. These are low power radars, which heavily rely on advanced hardware and powerful real time signal processing. Additional information is included in the original extended abstract.

Arokiasamy, B. J.↗

Influence of low concentrations of scatterers and signal detection time on the results of their measurements using dynamic light scattering

The influence of limited detection time on the form of the autocorrelation function (ACF) has been analysed for measurements in low-concentration suspensions by dynamic light scattering with allowance for the spatial distribution of the laser beam intensity. The general view of the ACF of the scattered light intensity is obtained for a Gaussian beam and a finite measurement time. The results of the theoretical analysis are compared with the experimental data and the results obtained by computer simulation of the scattering from an ensemble of particles involved in Brownian motion in a Gaussian beam. It is shown that, in the case of low suspension concentrations, the ACF distortions related to finite detection time lead to underestimation of the particle sizes and occurrence of an artefact peak in the distribution of the scattered light intensity over scatterer sizes. An empirical dependence of the measured size of particles on their number in the scattering volume is found. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scalable and Actionable Performance Measures for Traffic Signal Systems using Probe Vehicle Trajectory Data

Scalable and actionable performance measures for traffic signal systems provide opportunities for practitioners to measure and improve the transportation network. Historically, traffic signal improvements have relied on scheduled signal retiming based on limited data collection, or on the public to call and alert engineers of an issue. This inefficient method of improving signal timing led to the creation of automated traffic signal performance measures (ATSPMs). These metrics rely on expensive infrastructure, including detection and communications, which has produced barriers for numerous agencies to fully adopt. Recently, third-party data providers have begun to release vehicle trajectory data, which allows for enhanced signal metrics with no investment in physical equipment. The purpose of this study is to demonstrate the use of these data and summarize the scalability of the created metrics. This work builds on previous efforts to quantify signal performance on nine intersections in Michigan, U.S. Ten signalized corridors in Columbus, Ohio, were chosen to scale a performance assessment using crowdsourced trajectory data. A total of 136 intersections were assessed in 2-h intervals using data from all weekdays in 2017. High-level corridor summary metrics including average percent of vehicles stopping (18%–32%), average delay (9.4–20.5 s), and level of travel time reliability (1.23–2.73) were calculated for each corridor direction. Intersection-level metrics were also introduced, which can be used by practitioners to identify problems, improve signal timings, and prioritize future infrastructure investments.

99 GENERAL AND MISCELLANEOUS↗

Note: A large open ratio, time, and position sensitive detector for time of flight measurements in UHV

We report on the construction of an UHV compatible 40 mm active diameter detector based on micro channel plates and assembled directly on the feed-throughs of a DN63CF flange. It is based on the charge division technique and uses a standard 2 inch Si wafer as a collector. The front end electronic is placed directly on the air side of the flange allowing excellent immunity to noise and a very good timing signal with reduced ringing. The important aberrations are corrected empirically providing an absolute positioning accuracy of 500 μm while a 150 μm resolution is measured in the center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attosecond transient absorption instrumentation for thin film materials: Phase transitions, heat dissipation, signal stabilization, timing correction, and rapid sample rotation

We present an extreme ultraviolet (XUV) transient absorption apparatus tailored to attosecond and femtosecond measurements on bulk solid-state thin-film samples, specifically when the sample dynamics are sensitive to heating effects. The setup combines methodology for stabilizing sub-femtosecond time-resolution measurements over 48 h and techniques for mitigating heat buildup in temperature-dependent samples. Single-point beam stabilization in pump and probe arms and periodic time-zero reference measurements are described for accurate timing and stabilization. A hollow-shaft motor configuration for rapid sample rotation, raster scanning capability, and additional diagnostics are described for heat mitigation. Heat transfer simulations performed using a finite element analysis allow comparison of sample rotation and traditional raster scanning techniques for 100 Hz pulsed laser measurements on vanadium dioxide, a material that undergoes an insulator-to-metal transition at a modest temperature of 340 K. Experimental results are presented confirming that the vanadium dioxide (VO 2 ) sample cannot cool below its phase transition temperature between laser pulses without rapid rotation, in agreement with the simulations. The findings indicate the stringent conditions required to perform rigorous broadband XUV time-resolved absorption measurements on bulk solid-state samples, particularly those with temperature sensitivity, and elucidate a clear methodology to perform them.

47 OTHER INSTRUMENTATION↗

Implementation of real-time digital signal processing systems

Special purpose hardware implementation of DFT Computers and digital filters is considered in the light of newly introduced algorithms and IC devices. Recent work by Winograd on high-speed convolution techniques for computing short length DFT's, has motivated the development of more efficient algorithms, compared to the FFT, for evaluating the transform of longer sequences. Among these, prime factor algorithms appear suitable for special purpose hardware implementations. Architectural considerations in designing DFT computers based on these algorithms are discussed. With the availability of monolithic multiplier-accumulators, a direct implementation of IIR and FIR filters, using random access memories in place of shift registers, appears attractive. The memory addressing scheme involved in such implementations is discussed. A simple counter set-up to address the data memory in the realization of FIR filters is also described. The combination of a set of simple filters (weighting network) and a DFT computer is shown to realize a bank of uniform bandpass filters. The usefulness of this concept in arriving at a modular design for a million channel spectrum analyzer, based on microprocessors, is discussed.

Narasimha, M.↗

Characterization of the Vectron PX-570 Crystal Oscillator for Use in Harsh Environments

Computing hardware, data-acquisition systems, communications systems, and many electronic control systems require well-controlled timing signals for proper and accurate operation. These signals are, in most cases, provided by circuits that employ crystal oscillators due to availability, cost, ease of operation, and accuracy. In some cases, the electronic systems are expected to survive and operate under harsh conditions that include exposure to extreme temperatures. These applications exist in terrestrial systems as well as in aerospace products. Well-logging, geothermal systems, and industrial process control are examples of ground-based applications, while distributed jet engine control in aircraft, space-based observatories (such as the James Webb Space Telescope), satellites, and lunar and planetary landers are typical environments where electronics are exposed to harsh operating conditions. To ensure these devices produce reliable results, the digital heartbeat from the oscillator must deliver a stable signal that is not affected by external temperature or other conditions. One such solution is a recently introduced commercial-off-the-shelf (COTS) oscillator, the PX-570 series from Vectron International. The oscillator was designed for high-temperature applications and as proof, the crystal oscillator was subjected to a wide suite of tests to determine its ruggedness for operation in harsh environments. The tests performed by Vectron included electrical characterization under wide range of temperature, accelerated life test/aging, shock and vibration, internal moisture analysis, ESD threshold, and latch-up testing. The parametric evaluation was performed on the oscillator's frequency, output signal rise and fall times, duty cycle, and supply current over the temperature range of -125 C to +230 C. The evaluations also determined the effects of thermal cycling and the oscillator's re-start capability at extreme hot and cold temperatures. These thermal cycling and restart tests were performed at the NASA Glenn Research Center. Overall, the crystal oscillator performed well and demonstrated very good frequency stability. This paper will discuss the test procedures and present details of the performance results.

Li, Jacob↗

Signal processor architecture for backscatter radars

Real time signal processing for backscatter radars which requires computational throughput and I/O rates is discussed. The operations that are usually performed in real time are highly repetitive simple accumulations of samples or of products of samples. The control logic does not depend on the values of the data and general purpose computers are not required for the initial high speed processing. The implications of these facts on the architectures of preprocessors for backscatter radars are explored and applied to the design of the Radar Signal Compender.

Swartz, W. E.↗

Hybrid model predictive control techniques for safety factor profile and stored energy regulation while incorporating NBI constraints

Abstract A novel hybrid Model Predictive Control (MPC) algorithm has been designed for simultaneous safety factor ( q ) profile and stored energy ( w ) control while incorporating the pulse-width-modulation constraints associated with the neutral beam injection (NBI) system. Regulation of the q -profile has been extensively shown to be a key factor for improved confinement as well as non-inductive sustainment of the plasma current. Simultaneous control of w is necessary to prevent the triggering of pressure-driven magnetohydrodynamic instabilities as the controller shapes the q profile. Conventional MPC schemes proposed for q -profile control have considered the NBI powers as continuous-time signals, ignoring the discrete-time nature of these actuators and leading in some cases to performance loss. The hybrid MPC scheme in this work has the capability of incorporating the discrete-time actuator dynamics as additional constraints. In nonlinear simulations, the proposed hybrid MPC scheme demonstrates improved q -profile+ w control performance for NSTX-U operating scenarios.

Physics↗

On Road Testing Data

This dataset provides the following on road testing data: - Videos - In-vehicle dash camera videos during different testing scenarios. - Signal controller data - NTCIP log data and processed signal timing data from the corresponding signal controllers - Vehicle data - Vehicle data recorded during the testing, including GNSS, communication, CAN signals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sub-Nyquist Distortions in Sampled One- and Two-Dimensional Signals Studied

Hardware testing frequently involves the acquisition of waveform and instrumentation signals, which are often recorded on waveform recorders, oscillographs, and video recorders. Years ago, the waveforms were viewed as analog records, as drawn by a paper strip chart pen or electron beam on a cathode ray tube screen. One of the problems in the past was that the analog electronics may not have been able to accurately display the full amplitude of a signal if the real-time signals exceeded the frequency response bandwidth of the recording device. The advent of digital oscilloscopes, waveform recorders, and video frame-grabbers solved many of the frequency response problems, though not all. A restriction on digital waveform acquisition is well known by people in the instrumentation field. Put simply, the sampling frequency must be at least twice the frequency of any signal to be sampled, or vice versa; the signals must be filtered so that none of the signal frequencies are higher than one-half the sample rate (the Nyquist Limit). Then, per Shannon's Sampling Theorem (1949, ref. 1), any sampled signal can be reconstructed for viewing on a display device. If any signals exceed the Nyquist frequency limit, error signals called aliases occur in the output display.

Williams, Glenn L.↗

Developing Detectors for Scintillation Light in Liquid Argon for DUNE

The Deep Underground Neutrino experiment will conduct a broad program of physics research by studying a beam of neutrinos from Fermilab, atmospheric neutrinos, neutrinos from potential supernovae, and potential nucleon decay events. In pursuit of these studies, the experiment will deploy four 10kt fiducial mass liquid argon time projection chambers underground in Lead, South Dakota. Liquid argon time projection chambers allow high-resolution tracking and energy measurements. A precise timing signal is needed to provide the necessary time stamp to localize events in the drift direction. As liquid argon is a natural scintillator, a photon detection system will be deployed to provide such a signal, especially for non-beam events. In the baseline design for the single-phase time projection chamber, the detectors are contained within the anode plane assemblies. The design of two prototypes utilizing wavelength shifters and light guides are presented, and aspects of the research and development program are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assured Timing Detector

The Assured Timing Detector software provides an implementation in C++ of an adaptable, model-based system for monitoring a timing signal for anomalies versus a reference time source ensemble

Beauchamp, BrockR↗