Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advanced Signal Processing for High Temperatures Health Monitoring of Condensed Water Height in Steam Pipes

An advanced signal processing methodology is being developed to monitor the height of condensed water thru the wall of a steel pipe while operating at temperatures as high as 250deg. Using existing techniques, previous study indicated that, when the water height is low or there is disturbance in the environment, the predicted water height may not be accurate. In recent years, the use of the autocorrelation and envelope techniques in the signal processing has been demonstrated to be a very useful tool for practical applications. In this paper, various signal processing techniques including the auto correlation, Hilbert transform, and the Shannon Energy Envelope methods were studied and implemented to determine the water height in the steam pipe. The results have shown that the developed method provides a good capability for monitoring the height in the regular conditions. An alternative solution for shallow water or no water conditions based on a developed hybrid method based on Hilbert transform (HT) with a high pass filter and using the optimized windowing technique is suggested. Further development of the reported methods would provide a powerful tool for the identification of the disturbances of water height inside the pipe.

health monitoring↗

A satellite temperature-flux monitor for low perigee applications

An inexpensive, compact, low power, fast response temperature-flux instrument complete with supporting software is described. The device was subjected to extensive ground testing and performed successfully in orbital flight. Highlights of mission results to date are included.

Young, E. W., Jr.↗

Heat pulse testing at monitoring wells to estimate subsurface fluid velocities in geological CO 2 storage

Monitoring the injected CO 2 during geological CO 2 storage (GCS) is essential to assure containment and identify CO 2 leakage. Here in this work, a new approach is introduced to estimate the evolution of the downhole fluid velocity at a monitoring well and identify CO 2 arrival time using in-well heat pulse/tracer test. The proposed technique involves using a downhole heater to generate a series of heat pulses and measuring their corresponding temperature response. The surface temperature of the downhole heater is controlled by the supplied electrical power and the heat loss by convection to the surroundings. Convective heat transfer is well described using Newton's law of cooling in which the temperature difference between the heater and the surrounding fluids drives the heat transfer, for which the convection heat transfer coefficient (h) controls the magnitude of heat loss. Among various factors that control h, it depends on the type of the flowing fluid and its velocity. Through analyzing the measured temperature at different heat pulses, the changes in h - due to mobilization of the in-situ brine or CO 2 arrival - can be estimated. Consequently, the velocity of the flowing fluid across the heater can be obtained. Since heat transfer by convection is sensitive to the type of the surrounding fluid, intrusion of CO 2 can be detected from the relatively higher surface temperature obtained at CO 2 arrival. Churchill and Bernstein (1977)'s correlation is adopted to estimate the change of fluid velocity in terms of the change in h. To demonstrate the validity of the proposed technique, the results are applied and validated against those of COMSOL Multiphysics simulation tool for single-phase brine (before CO 2 arrival) and single-phase CO 2 (after CO 2 arrival). The observed temperature heating is sensitive to the flowing fluid velocity and fluid type. The temperature signal observed at CO 2 arrival is large and easily detectable using temperature monitoring tool which provides reliable indication for tracking CO 2 arrival at monitoring wells compared with passive temperature monitoring. The results obtained using the proposed technique agree very well with the numerical results obtained from the simulation tool with a maximum estimation error of 7 percent.

02 PETROLEUM↗

An underground, wireless, open-source, low-cost system for monitoring oxygen, temperature, and soil moisture

Abstract. The use of wireless sensor networks to measure soil parameters eliminates the need to remove sensors for field operations, such as tillage, thus allowing long-term measurements without multiple disturbances to soil structure. Wireless sensors also reduce above-ground cables and the risk of undesired equipment damage and potential data loss. However, implementing wireless sensor networks in field studies usually requires advanced and costly engineering knowledge. This study presents a new underground, wireless, open-source, low-cost system for monitoring soil oxygen, temperature, and soil moisture. The process of system design, assembly, programming, deployment, and power management is presented. The system can be left underground for several years without the need to change the battery. Emphasis was given on modularity so that it can be easily duplicated or changed if needed and deployed without previous engineering knowledge. Data from this type of system have a wide range of applications, including precision agriculture and high-resolution modelling.

54 ENVIRONMENTAL SCIENCES↗

SECARB Distributed Temperature Sensing Data

Distributed Temperature Sensing data files collected during the SECARB project from Detailed Area of Study wells (CFU F-1, F-2, F-3) at Cranfield oil site in Mississippi. Associated Publications: Nuñez-López, V., Muñoz-Torres, J., and Zeidouni, M., 2014, Temperature monitoring using distributed temperature sensing (DTS) technology: Energy Procedia, v. 63, p. 3984–3991, doi:10.1016/j.egypro.2014.11.428.

CCS↗

Modeling Approach for the Aluminum-clad Dry Storage Pilot using HFIR Fuel

To confirm that the dry storage of aluminum-clad research reactor spent nuclear fuel (ASNF) will remain within the safety envelope after applied drying schemes and that the resulting evolution of the gas space composition, temperature, and pressure conditions are understood, a dry storage pilot project is being established. The pilot will incorporate an instrumented lid for discrete interval or for on-demand gas composition and temperature monitoring of two DOE Standard Canisters (DSCs) loaded with three High Flux Isotope Reactor (HFIR) inner cores per DSC. Each DSC would be subjected to a separate alternative candidate drying scheme. Canisters will undergo 1 to 5 years of monitoring, including internal temperature and gas sampling to track pressure and composition changes. This report outlines the approach for modeling the ASNF-in-canister behavior in terms of evolving gas space conditions for the ASNF dry storage pilot using HFIR fuel. The ASNF has an adherent surface oxyhydroxide layer comprised of boehmite/bayerite that generates hydrogen when subjected to irradiation. Three-dimensional multi-physics computational fluid dynamics simulations will be executed to compute the thermal field within the DSC and provide inputs to a chemical model employed to compute pressure buildup as hydrogen is generated in the system. Implemented in Cantera, the chemical model solves gas phase and aluminum oxyhydroxide surface-mediated radiolysis reactions. Gas phase reactions are sourced from Wittman and Hanson (2015), whereas surface-mediated reactions are incorporated by fitting experimental data using an optimization algorithm (Abboud, 2023). Water radiolysis reactions from Wren and Ball (2001) are adopted with modifications as described in Abboud (2023c). Understanding the effect of the hydrogen buildup over time is important for long-term storage safety considerations. Modeling results will include the canister pressure, temperature, and composition evolution from the initial helium backfill with the addition of radiolytically-evolved chemical species (e.g., hydrogen and oxygen). The specific HFIR cores for the pilot program have not yet been selected, and the overall design is still in development. The CFD-chemical model used for this work will be based on prior models with necessary updates to allow for improved accuracy and efficiency. The experimental data obtained from the HFIR demonstration will be used to improve and validate the computational models to predict the ASNF-in-canister behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Li-ion pouch cell and a cell module

The present invention provides a Li-ion pouch cell wherein the Li-ion pouch cells comprise a sealed enclosure, electrode stack and thermally conductive elements, wherein the electrode stack and the thermally conductive elements are in the sealed enclosure, the thermally conductive elements include extensions which extend beyond the electrode stack, the sealed enclosure has thermal conductivity, the thermally conductive elements provide a thermally conductive pathway connecting the electrode stack and the sealed enclosure by way of the extension. The present invention also provides a cell module comprising the Li-ion pouch cells. The Li-ion pouch cell and the cell module according to the present application could minimize differences in cell temperature, monitor internal cell temperature, cool the cell rapidly, increase cell and module safety, allowing for minimal impact on cell energy density, performance or life and difficulty of manufacturing.

25 ENERGY STORAGE↗

Monitoring of Temperature Measurements for Different Flow Regimes in Water and Galinstan with Long Short-Term Memory Networks and Transfer Learning of Sensors

Temperature sensing is one of the most common measurements of a nuclear reactor monitoring system. The coolant fluid flow in a reactor core depends on the reactor power state. We investigated the monitoring and estimation of the thermocouple time series using machine learning for a range of flow regimes. Measurement data were obtained, in two separate experiments, in a flow loop filled with water and with liquid metal Galinstan. We developed long short-term memory (LSTM) recurrent neural networks (RNNs) for sensor predictions by training on the sensor’s own prior history, and transfer learning LSTM (TL-LSTM) by training on a correlated sensor’s prior history. Sensor cross-correlations were identified by calculating the Pearson correlation coefficient of the time series. The accuracy of LSTM and TL-LSTM predictions of temperature was studied as a function of Reynolds number (Re). The root-mean-square error (RMSE) for the test segment of time series of each sensor was shown to linearly increase with Re for both water and Galinstan fluids. Using linear correlations, we estimated the range of values of Re for which RMSE is smaller than the thermocouple measurement uncertainty. For both water and Galinstan fluids, we showed that both LSTM and TL-LSTM provide reliable estimations of temperature for typical flow regimes in a nuclear reactor. The LSTM runtime was shown to be substantially smaller than the data acquisition rate, which allows for performing estimation and validation of sensor measurements in real time.

Pantopoulou, Stella↗

Additive-assisted synthesis of boride, carbide, and nitride micro/nanocrystals

General and simple methods for the syntheses of borides, carbides and nitrides are highly desirable, since those materials have unique physical properties and promising applications. Here, a series of boride (TiB{sub 2}, ZrB{sub 2}, NbB{sub 2}, CeB{sub 6}, PrB{sub 6}, SmB{sub 6}, EuB{sub 6}, LaB{sub 6}), carbide (SiC, TiC, NbC, WC) and nitride (TiN, BN, AlN, MgSiN{sub 2}, VN) micro/nanocrystals were prepared from related oxides and amorphous boron/active carbon/NaN{sub 3} with the assistance of metallic Na and elemental S. In-situ temperature monitoring showed that the reaction temperature could increase quickly to {approx}850 Degree-Sign C, once the autoclave was heated to 100 Degree-Sign C. Such a rapid temperature increase was attributed to the intense exothermic reaction between Na and S, which assisted the formation of borides, carbides and nitrides. The as-obtained products were characterized by XRD, SEM, TEM, and HRTEM techniques. Results in this report will greatly benefit the future extension of this approach to other compounds. - Graphical abstract: An additive-assisted approach is successfully developed for the syntheses of borides, carbides and nitrides micro/nanocrystals with the assistance of the exothermic reaction between Na and S. Highlights: Black-Right-Pointing-Pointer An additive-assisted synthesis strategy is developed for a number of borides, carbides and nitrides. Black-Right-Pointing-Pointer The reaction mechanism is demonstrated by the case of SiC nanowires. Black-Right-Pointing-Pointer The formation of SiC nanowires is initiated by the exothermic reaction of Na and S.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Report on FY16 Low-dose Metal Fuel Irradiation and PIE

This report gives an overview of the efforts into the low-dose metal fuel irradiation and PIE as part of the Fuel Cycle Research & Development (FCRD) Advanced Fuels Campaign (AFC) milestone M3FT-16OR020303031. The current status of the FCT and FCRP irradiation campaigns are given including a description of the materials that have been irradiated, analysis of the passive temperature monitors, and the initial PIE efforts of the fuel samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-temperature all-fiber non-destructive multi-parameter sensing system with consistent performance

A high-temperature all-fiber non-destructive multi-parameter sensing system is developed. The system can operate consistently in a wide range of temperature changes by specially designed active signal generation and detection units. It is capable of monitoring temperature up to 600°C and cracks on metal pipes with an acoustic wave generation unit and an acoustic detection unit. A gold-coated multi-mode fiber is used to deliver a laser pulse for acoustic excitation while minimizing parasitic acoustic signals at high temperature. An in-fiber Fabry–Perot fiber Bragg grating (FP-FBG) is fabricated in another single-mode fiber and bonded to the test object for acoustic detection. The FP-FBG avoids strain redistribution inside the bonder at high temperature to ensure consistent operation. The feasibility of the system for temperature monitoring and crack detection in real-world applications is also demonstrated on an industry-standard P91 pipe.

He, Jiaji (ORCID:0000000165661887)↗

Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound

Purpose: To investigate k-space subsampling strategies to achieve fast, large field-of-view (FOV) temperature monitoring using segmented echo planar imaging (EPI) proton resonance frequency shift thermometry for MR guided high intensity focused ultrasound (MRgHIFU) applications. Methods: Five different k-space sampling approaches were investigated, varying sample spacing (equally vs nonequally spaced within the echo train), sampling density (variable sampling density in zero, one, and two dimensions), and utilizing sequential or centric sampling. Three of the schemes utilized sequential sampling with the sampling density varied in zero, one, and two dimensions, to investigate sampling the k-space center more frequently. Two of the schemes utilized centric sampling to acquire the k-space center with a longer echo time for improved phase measurements, and vary the sampling density in zero and two dimensions, respectively. Phantom experiments and a theoretical point spread function analysis were performed to investigate their performance. Variable density sampling in zero and two dimensions was also implemented in a non-EPI GRE pulse sequence for comparison. All subsampled data were reconstructed with a previously described temporally constrained reconstruction (TCR) algorithm. Results: The accuracy of each sampling strategy in measuring the temperature rise in the HIFU focal spot was measured in terms of the root-mean-square-error (RMSE) compared to fully sampled “truth.” For the schemes utilizing sequential sampling, the accuracy was found to improve with the dimensionality of the variable density sampling, giving values of 0.65 °C, 0.49 °C, and 0.35 °C for density variation in zero, one, and two dimensions, respectively. The schemes utilizing centric sampling were found to underestimate the temperature rise, with RMSE values of 1.05 °C and 1.31 °C, for variable density sampling in zero and two dimensions, respectively. Similar subsampling schemes with variable density sampling implemented in zero and two dimensions in a non-EPI GRE pulse sequence both resulted in accurate temperature measurements (RMSE of 0.70 °C and 0.63 °C, respectively). With sequential sampling in the described EPI implementation, temperature monitoring over a 192 × 144 × 135 mm{sup 3} FOV with a temporal resolution of 3.6 s was achieved, while keeping the RMSE compared to fully sampled “truth” below 0.35 °C. Conclusions: When segmented EPI readouts are used in conjunction with k-space subsampling for MR thermometry applications, sampling schemes with sequential sampling, with or without variable density sampling, obtain accurate phase and temperature measurements when using a TCR reconstruction algorithm. Improved temperature measurement accuracy can be achieved with variable density sampling. Centric sampling leads to phase bias, resulting in temperature underestimations.

42 ENGINEERING↗

Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer

A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature T{sub e} estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Δn = 0, 1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300–1600 Å. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time T{sub e}-dependent signal within a characteristic divertor detachment equilibration time of ∼10–15 ms is expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AOI [3]: Smart Refractory Sensor Systems for Wireless Monitoring of Temperature, Health, and Degradation of Slagging Gasifiers

The objective of the work was to develop refractory “smart bricks”, which would contain embedded temperature, strain/stress, and spallation sensors throughout the volume of highchromia (-Cr 2 O 3 ) refractory brick. The proposed work included work to interconnect the sensors to the reactor exterior, where the sensor signals may be processed by low-power electronics and transmitted wirelessly to a central processing hub. The data processing and wireless transmitter hardware was specifically designed to be isolated (with low power consumption) and to be adaptable to future implementation of energy-harvesting strategies for extended life. Finally, the collected data was incorporated into a model to estimate refractory degradation, a technique that could help monitor the health of the refractory in real-time. The long-term goal of this program was to demonstrate high-temperature, wireless sensor arrays for in situ three-dimensional (3-D) refractory monitoring or mapping for slagging gasification systems. The research was in collaboration with HarbisonWalker International (HWI) Technology Center in West Mifflin, PA. HWI is a leading developer and manufacturer of ceramic refractory products for high-temperature applications. The work completed focused on the following areas: 1) Investigation of the chemical stability, microstructural evolution, grain growth kinetics, degree of homogeneity (quantitative image analysis), and electrical properties of refractory oxide-silicide composites at temperatures between 750-1450ºC; 2) Fabrication of silicide-alumina composite and oxide thermocouples and thermistor preforms and the development of techniques to embed them into high-chromia refractory bricks to form “smart bricks”; 3) Utilization of commercial off-the-shelf discrete components to prototype circuits for interfacing between smart brick sensors and the wireless sensor network. The prototypes were then used to design an integrated circuit for thermistor, thermocouple, and capacitive-based smart brick sensor interfacing; 4) Interfacing of the smart bricks with embedded sensors with wireless motes thus yielding a complete signal chain. This end-to-end data collection system was tested on a furnace heated to 1350°C; 5) Development of a slag penetration model and a nonlinear unknown input filter for the data from the embedded sensors for estimating temperature and extent of slag penetration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗