Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNETIUM ISOTOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-C-9A-04: Alternative Analytic Solution to the Paralyzable Detector Model to Calculate Deadtime and Deadtime Loss

Purpose: Some common methods to solve for deadtime are (1) dual-source method, which assumes two equal activities; (2) model fitting, which requires multiple acquisitions as source decays; and (3) lossless model, which assumes no deadtime loss at low count rates. We propose a new analytic alternative solution to calculate deadtime for paralyzable gamma camera. Methods: Deadtime T can be calculated analytically from two distinct observed count rates M1 and M2 when the ratio of the true count rates alpha=N2/N1 is known. Alpha can be measured as a ratio of two measured activities using dose calibrators or via radioactive decay. Knowledge of alpha creates a system with 2 equations and 2 unknowns, i.e., T and N1. To verify the validity of the proposed method, projections of a non-uniform phantom (4GBq 99mTc) were acquired in using Siemens SymbiaS multiple times over 48 hours. Each projection has >100kcts. The deadtime for each projection was calculated by fitting the data to a paralyzable model and also by using the proposed 2-acquisition method. The two estimates of deadtime were compared using the Bland-Altmann method. In addition, the dependency of uncertainty in T on uncertainty in alpha was investigated for several imaging conditions. Results: The results strongly suggest that the 2-acquisition method is equivalent to the fitting method. The Bland-Altman analysis yielded mean difference in deadtime estimate of ∼0.076us (95%CI: -0.049us, 0.103us) between the 2-acquisition and model fitting methods. The 95% limits of agreement were calculated to be -0.104 to 0.256us. The uncertainty in deadtime calculated using the proposed method is highly dependent on the uncertainty in the ratio alpha. Conclusion: The 2-acquisition method was found to be equivalent to the parameter fitting method. The proposed method offers a simpler and more practical way to analytically solve for a paralyzable detector deadtime, especially during physics testing.

07 ISOTOPE AND RADIATION SOURCES↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

Using Rose’s metal alloy as a pinhole collimator material in preclinical small-animal imaging: A Monte Carlo evaluation

Purpose: Pinhole collimation is the most common method of high-resolution preclinical single photon emission computed tomography imaging. The collimators are usually constructed from dense materials with high atomic numbers, such as gold and platinum, which are expensive and not always flexible in the fabrication step. In this work, the authors have investigated the properties of a fusible alloy called Rose’s metal and its potential in pinhole preclinical imaging. When compared to current standard pinhole materials such as gold and platinum, Rose’s metal has a lower density and a relatively low effective atomic number. However, it is inexpensive, has a low melting point, and does not contract when solidifying. Once cast, the piece can be machined with high precision. The aim of this study was to evaluate the imaging properties for Rose’s metal and compare them with those of standard materials. Methods: After validating their Monte Carlo code by comparing its results with published data and the results from analytical calculations, they investigated different pinhole geometries by varying the collimator material, acceptance angle, aperture diameter, and photon incident angle. The penetration-to-scatter and penetration-to-total component ratios, sensitivity, and the spatial resolution were determined for gold, tungsten, and Rose’s metal for two radionuclides, {sup 99}Tc{sup m} and {sup 125}I. Results: The Rose’s metal pinhole-imaging simulations show higher penetration/total and scatter/total ratios. For example, the penetration/total is 50% for gold and 75% for Rose’s metal when simulating {sup 99}Tc{sup m} with a 0.3 mm aperture diameter and a 60° acceptance angle. However, the degradation in spatial resolution remained below 10% relative to the spatial resolution for gold for acceptance angles below 40° and aperture diameters larger than 0.5 mm. Conclusions: Extra penetration and scatter associated with Rose’s metal contribute to degradation in the spatial resolution, but this degradation is not always substantial. The most important factor besides the collimator material was the acceptance angle. This should be kept to a minimum to prevent unnecessary scatter and penetration. For {sup 125}I, the difference in spatial resolution between gold and Rose’s metal is very small, 2.2% in the worst-case scenario. Based on these results, the authors conclude that Rose’s metal is an alternative to standard materials not only for low-energy photon imaging but also for medium-energy applications that require low-cost, flexible pinhole configurations and designs, and that can tolerate a degraded spatial resolution.

07 ISOTOPE AND RADIATION SOURCES↗

Photo-Transmutation of {sup 100}Mo to {sup 99m}Tc with Laser-Compton Scattering Gamma-Ray

Technetium-99m ({sup 99m}Tc) is an important medical radioisotope which is largely used in hospitals for diagnosis of cancer. It is produced in the form of {sup 99}Mo which decays to {sup 99m}Tc with a half-life of 66 hours. More than 90% of the world's demand of {sup 99}Mo are sourced from five nuclear reactors. Two of these reactors have already been closed and the rest are more than 45 years old. Relatively short half-life of the parent {sup 99}Mo requires continuous re-supply to meet the medical industry's requirement. Therefore there is an urgent need to produce the {sup 99}Mo and {sup 99m}Tc isotopes by alternative ways. This paper presents one such alternative via the use of laser-Compton scattering (LCS) gamma beam. In this paper, production rate (reaction rate) of {sup 99}Mo using the photonuclear (γ, n) reaction is evaluated. It is expected that the LCS technique can be used to generate the gamma ray required for the aforementioned photonuclear reaction. Rigorous optimization of the LCS spectrum is also performed to maximize production of the {sup 99}Mo. The optimal maximum energy of the LCS photon is about 17 MeV for the production of {sup 99}Mo. The analysis shows that production of {sup 99}Mo using LCS gamma beam offers a promising alternative for the production of {sup 99m}Tc. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Production of medical {sup 99m}Tc isotope via photonuclear reaction

{sup 99m}Tc with a 6 hour half-life is one of the most important medical isotopes used for the Single-Photon Emission Computed Tomography (SPECT) inspection in hospitals of US, Canada, Europe and Japan. {sup 99m}Tc isotopes are extracted by the milking method from parent {sup 99}Mo isotopes with a 66 hour half-life. The supply of {sup 99}Mo isotopes now encounters a serious crisis. Hospitals may not suitably receive {sup 99}Mo medical isotopes in near future, due to difficulties in production by research nuclear reactors. Many countries are now looking for alternative ways to generate {sup 99}Mo isotopes other than those with research reactors. We discuss a sustained availability of {sup 99m}Tc isotopes via the {sup nat}Mo(γ, n) photonuclear reaction, and discuss to solve technical problems for extracting pure {sup 99m}Tc isotopes from other output materials of photonuclear reactions.

07 ISOTOPE AND RADIATION SOURCES↗

The Texas A&M Radioisotope Production and Radiochemistry Program

The main motivation of the project at Texas A&M University was to carry out the production of critically needed radioisotopes used in medicine for diagnostic and therapy, and to establish an academic program in radionuclide production and separation methods. After a lengthy battle with the Texas A&M University Radiation Safety Office, the Texas Department of State Health Services granted us a license for the production of radionuclides in July 2015, allowing us to work in earnest in our project objectives. Experiments began immediately after licensing, and we started the assembly and testing of our target systems. There were four analytical/theoretical projects and two experimental target systems. These were for At-211 production and for Zn- 62/Cu-62 production. The theoretical projects were related to the production of Mo-99/Tc-99m using (a) a subcritical aqueous target system and (b) production of Tc-99m from accelerator-generated Mo-99 utilizing a photon-neutron interaction with enriched Mo-100 targets. The two experimental projects were the development of targetry systems and production of At-211 and Zn-62/Cu-62 generator. The targetry system for At-211 has been tested and production of At-211 is chronic depending of availability of beam time at the cyclotron. The installation and testing of the targetry system for the production of Zn-62/Cu-62 has not been finalized. A description of the systems is described. The academic program in radionuclide production and separation methods was initiated in the fall of 2011; due to the lack of a radiochemistry laboratory, it was suspended. We expect to re-start the academic program at the Texas A&M Institute for Preclinical Studies under the Molecular Imaging Program.

43 PARTICLE ACCELERATORS↗

Irradiation of Mo-100 Targets and Testing Fe(ll)CI 2 Precipitation for Tc-99 Removal

The production of molybdenum-99 (Mo-99) is a critical step in the generation of technetium-99m (Tc-99m), a radioisotope widely used in medical imaging. NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope Mo-99 through a photonuclear reaction on molybdenum-100 (Mo-100). Accelerator production of Mo-99 using enriched Mo-100 targets yields undesirable isotopes, such as niobium-95 (Nb-95) and zirconium-95 (Zr-95). Previous studies reported that Nb and Zr isotopes can be effectively removed from Mo-99 products through coprecipitation with Fe(III). To enable the potential utilization of the first milking of Tc-99m from a Mo-99/Tc-99m generator, it is desirable to remove long-lived Tc-99. This can be accomplished by substituting Fe(III) with Fe(II) during the precipitation step, without affecting the removal of Zr and Nb isotopes. Previous experiments demonstrated up to 99+% removal of Tc using this method. It was also observed that the presence of hydrogen peroxide significantly impacts Tc removal. This was evident in the processing of enriched Mo-100 targets, where only 25% of Tc was removed. To further investigate this, another irradiation of enriched Mo-100 disks was conducted, followed by Tc-99 removal using Fe(II). Prior to irradiation, experimental conditions for Tc removal were optimized through several test runs using Mo-100 disks spiked with Tc-99. The results of these tests are discussed in this report.

07 ISOTOPE AND RADIATION SOURCES↗

Micro Ion Source Program NA22 Plutonium Detection Portfolio Final Report

The purpose of the micro ion source program was to enhance the performance of thermal ionization mass spectrometry (TIMS) for various actinides and fission products. The proposal hypothesized that when ions are created at the ion optic center of the mass spectrometer, ion transmission is significantly increased and the resulting ion beam is more sharply focused. Computer modeling demonstrated this logic. In order to prove this hypothesis it was first necessary to understand the chemistry and physics governing the particular ion production process that concentrates the emission of ions into a small area. This has been achieved for uranium and technetium, as was shown in the original proposal and the improvement of both the beam transmission and sharpness of focus were proven. Significantly improved analytical methods have been developed for these two elements based upon this research. The iodine portion of the proposal turned out to be impractical due to volatility of iodine and its compounds. We knew this was a possibility prior to research and we proceeded anyway but did not succeed. Plutonium is a potential option, but is not quite up to the performance level of resin beads. Now, we more clearly understand the chemical and physical issues for plutonium, but have not yet translated this knowledge into improved analytical processes. The problems are that plutonium is considerably more difficult to convert to the required intermediate species, plutonium carbide, and the chemical method we developed that works with uranium functions only moderately well with plutonium. We are of the opinion that, with this knowledge, similar progress can be made with plutonium.

07 ISOTOPE AND RADIATION SOURCES↗

Medical Isotope Production Analyses In KIPT Neutron Source Facility

Medical isotope production analyses in Kharkov Institute of Physics and Technology (KIPT) neutron source facility were performed to include the details of the irradiation cassette and the self-shielding effect. An updated detailed model of the facility was used for the analyses. The facility consists of an accelerator-driven system (ADS), which has a subcritical assembly using low-enriched uranium fuel elements with a beryllium-graphite reflector. The beryllium assemblies of the reflector have the same outer geometry as the fuel elements, which permits loading the subcritical assembly with different number of fuel elements without impacting the reflector performance. The subcritical assembly is driven by an external neutron source generated from the interaction of 100-kW electron beam with a tungsten target. The facility construction was completed at the end of 2015, and it is planned to start the operation during the year of 2016. It is the first ADS in the world, which has a coolant system for removing the generated fission power. Argonne National Laboratory has developed the design concept and performed extensive design analyses for the facility including its utilization for the production of different radioactive medical isotopes. 99 Mo is the parent isotope of 99m Tc, which is the most commonly used medical radioactive isotope. Detailed analyses were performed to define the optimal sample irradiation location and the generated activity, for several radioactive medical isotopes, as a function of the irradiation time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fiscal Year 2010 Summary Report on the Epsilon-Metal Phase as a Waste Form for 99 Tc

Epsilon metal (ε-metal) is generated in nuclear fuel during irradiation. This metal consists of Pd, Ru, Rh, Mo, and some Te. These accumulate at the UO 2 grain boundaries as small (ca 5 µm) particles. These metals have limited solubility in the acid used to dissolve fuel during reprocessing and in typical borosilicate glass. These must be treated separately to improve overall waste loading in glass. This low solubility and their survival in 2 Gy-old natural reactors led us to investigate them as a waste form for the immobilization of 99 Tc and 107 Pd, two very long-lived isotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-C-201-02: Quantitative Small-Animal SPECT Without Scatter Correction Using High-Purity Germanium Detectors

Purpose: To evaluate the impact of the exceptional energy resolution of germanium detectors for preclinical SPECT in comparison to conventional detectors. Methods: A cylindrical water phantom was created in GATE with a spherical Tc-99m source in the center. Sixty-four projections over 360 degrees using a pinhole collimator were simulated. The same phantom was simulated using air instead of water to establish the true reconstructed voxel intensity without attenuation. Attenuation correction based on the Chang method was performed on MLEM reconstructed images from the water phantom to determine a quantitative measure of the effectiveness of the attenuation correction. Similarly, a NEMA phantom was simulated, and the effectiveness of the attenuation correction was evaluated. Both simulations were carried out using both NaI detectors with an energy resolution of 10% FWHM and Ge detectors with an energy resolution of 1%. Results: Analysis shows that attenuation correction without scatter correction using germanium detectors can reconstruct a small spherical source to within 3.5%. Scatter analysis showed that for standard sized objects in a preclinical scanner, a NaI detector has a scatter-to-primary ratio between 7% and 12.5% compared to between 0.8% and 1.5% for a Ge detector. Preliminary results from line profiles through the NEMA phantom suggest that applying attenuation correction without scatter correction provides acceptable results for the Ge detectors but overestimates the phantom activity using NaI detectors. Due to the decreased scatter, we believe that the spillover ratio for the air and water cylinders in the NEMA phantom will be lower using germanium detectors compared to NaI detectors. Conclusion: This work indicates that the superior energy resolution of germanium detectors allows for less scattered photons to be included within the energy window compared to traditional SPECT detectors. This may allow for quantitative SPECT without implementing scatter correction, reducing uncertainties introduced by scatter correction algorithms. Funding provided by NIH/NIBIB grant R01EB013677; Todd Peterson, Ph.D., has had a research contract with PHDs Co., Knoxville, TN.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Conceptual Model for Vadose Zone Transport of Tc-99 at Hanford's BC Cribs and the Screening of Remedial Alternatives

A number of waste trenches at cribs at Hanford's BC Cribs and Trenches site, which received about 10 Mgal of scavenged tank waste with elevated concentrations of technetium-99 and nitrate, are currently being evaluated for remediation. The objective of this study was to investigate the influence of fine-scale heterogeneity (i.e. horizontal laminations, cross-bedding) on the large-scale transport behavior of mobile contaminants through the vadose zone with the purpose of developing a remedial strategy. The vertical heterogeneity structure, conditioned on grain size distributions and geophysical logs (water content and natural isotopes), was developed from a single borehole at the site. Geostatistical methods were used to impose the 3-D spatial correlation structure from the nearby well-characterized experimental site to merge the heterogeneities at various scales. Flow and transport properties were derived using physically-based property transfer models. The STOMP simulator was then used to predict contaminant transport through the vadose zone and into a 5-m thick confined aquifer during the period of trench operations (1956-1958) and to present time. Simulation results show that the fine-scale heterogeneity inside the large-scale lithologic units has considerable impact on the large-scale transport behavior of contaminants. The fine-scale heterogeneity enhanced the lateral flow and mixing and limited vertical penetration in the vadose zone. Model results are in excellent agreement with the vertical contaminant profile obtained from a borehole installed in the 216-B-26 trench. The simulated 2-D distribution of nitrate and electrical resistivity sounding curves also agreed well with results of field-scale resistivity surveys. These results suggest that installation of an engineered surface barrier would reduce the threat to ground water by reducing the mass flux of contaminants to the water table and increasing the residence time in the vadose zone.

54 ENVIRONMENTAL SCIENCES↗

Recommended Updates to Solubility Controls for Modeling Leaching of Technetium, Uranium, Neptunium, Plutonium, and Iodine from the Residual Waste Layer of Closed Savannah River Site High Level Waste Tanks

The objective of this report is to relate waste leaching experiments by the Savannah River National Laboratory (SRNL) to performance assessment modeling of release of several radionuclides from residual waste in closed high-level waste tanks. SRNL leached residual waste from Tanks 18F and 12H with solutions simulating the modeled evolution of pore fluids in residual waste layers of closed tanks through various stages of grout degradation. Tc-99, uranium isotopes, Np-237, plutonium isotopes, and I-129 were analyzed in the leachate multiple times over 90 days.

07 ISOTOPE AND RADIATION SOURCES↗

Design and experimental activities supporting commercial U.S. electron accelerator production of Mo-99

{sup 99m}Tc, the daughter isotope of {sup 99}Mo, is the most commonly used radioisotope for nuclear medicine in the United States. Under the direction of the National Nuclear Security Administration (NNSA), Los Alamos National Laboratory (LANL) and Argonne National Laboratory (ANL) are partnering with North Star Medical Technologies to demonstrate the viability of large-scale {sup 99}Mo production using electron accelerators. In this process, {sup 99}Mo is produced in an enriched {sup 100}Mo target through the {sup 100}Mo({gamma},n){sup 99}Mo reaction. Five experiments have been performed to date at ANL to demonstrate this process. This paper reviews the current status of these activities, specifically the design and performance of the helium gas target cooling system.

07 ISOTOPE AND RADIATION SOURCES↗

Low-dose dual-isotope procedure planed for myocardial perfusion CZT-SPECT and assessed through a head-to-head comparison with a conventional single-isotope protocol

Purpose of the report: This study aimed at assessing an original low-dose dual-isotope procedure in which the abnormal stress Tc-99m Sestamibi SPECT is followed by rest Tl-201 SPECT, along with a head-to-head comparison with a single-isotope procedure. Methods and results: One hundred two patients, referred for a low-dose stress-SPECT with Sestamibi (123 ± 20 MBq) on a CZT camera and for whom a rest Sestamibi SPECT was warranted, had an additional Tl-201 rest-SPECT (52 ± 5 MBq) between stress and rest Sestamibi SPECT recordings. Tl-201 images were processed for spill-over and scatter corrections, and uptake differences with stress Sestamibi SPECT were analyzed: (1) for rest acquisitions from Tl-201 (dual-isotope procedure) and from Sestamibi (single-isotope procedure) and (2) in segments for which a diagnosis of ischemia, infarct, or normal perfusion was achieved. Mean effective dose was 8.3 mSv for dual-isotope but would decrease to 5.7 mSv for an expected rate of 37% of patients for whom rest-SPECT is not warranted. After a further background correction of Tl-201 images, the rest–stress difference in myocardial uptake was equivalent between dual- and single-procedures for identifying ischemic segments (respective areas-under-curves: 0.83 ± 0.03 and 0.81 ± 0.03). Conclusion: This original dual-isotope procedure provides acceptable radiation doses and consistent results, as compared with conventional single-isotope.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of variable compositions on the removal of technetium from Hanford Waste Treatment Plant low activity waste melter off-gas condensate simulant

The Low Activity Waste (LAW) vitrification facility at the Hanford Waste Treatment and Immobilization Plant (WTP) will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the offgas system. The plan for disposition of this stream during baseline operations is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. The primary reason to recycle this stream is so that the semi-volatile 99 Tc isotope eventually becomes incorporated into the glass. This stream also contains non-radioactive salt components that are problematic in the melter, so diversion of this stream to another process would eliminate recycling of these salts and would enable simplified operation of the LAW melter and the Pretreatment Facilities. This diversion from recycling this stream within WTP would have the effect of decreasing the LAW vitrification mission duration and quantity of glass waste. The concept being tested here involves removing the 99 Tc so that the decontaminated aqueous stream, with the problematic salts, can be disposed elsewhere.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molybdenum-99 from Molten Salt Reactor as a Source of Technetium-99m for Nuclear Medicine: Past, Current, and Future of Molybdenum-99

Technitium-99m ( 99m Tc), a widely used radioisotope, is used in tens of millions of medical diagnostic procedures annually. However, it is hard to store and must be immediately used upon production due to its short half-life (i.e., 6 h); thus, it is currently produced from 99 Mo, which itself is a result of 235 U fission. The majority of 99 Mo supplies to U.S. patients are currently provided by foreign producers and produced using highly enriched uranium (HEU). In order to minimize the proliferation risks of HEU-based medical isotope production, the U.S. Department of Energy’s National Nuclear Security Administration has funded a program to accelerate the development of technologies to produce 99 Mo without the use of HEU. Today, the global supply of 99 Mo depends on a limited number of nuclear reactors, and production has been interrupted unexpectedly since 2009 due to the fleet’s advanced age. Herein, alternative options for 99 Mo production are discussed, and one potential option is to obtain 99m Tc from molten salt reactors (MSRs). A MSR is a nuclear fission reactor that can operate at or close to atmospheric pressure with liquid fuel, which allows for producing isotopes in a timely manner. In this paper, the past and current production of 99 Mo via nuclear reactors is described, and the future of 99 Mo production by MSRs is discussed. The behavior and chemical properties of molybdenum in fluoride salts in MSRs and the possible extraction methods are also examined in addition to the limitation of current studies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗