Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Subcritical measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Wind-tunnel experiments on divergence of forward-swept wings

An experimental study to investigate the aeroelastic behavior of forward-swept wings was conducted in the Langley Transonic Dynamics Tunnel. Seven flat-plate models with varying aspect ratios and wing sweep angles were tested at low speeds in air. Three models having the same planform but different airfoil sections (i.e., flat-plate, conventional, and supercritical) were tested at transonic speeds in Freon 12. Linear analyses were performed to provide predictions to compare with the measured aeroelastic instabilities which include both static divergence and flutter. Six subcritical response testing techniques were formulated and evaluated at transonic speeds for accuracy in predicting static divergence. Two "divergence stoppers" were developed and evaluated for use in protecting the model from structural damage during tests.

Ricketts, R. H.↗

Engineering and design properties of thallium-doped sodium iodide and selected properties of sodium-doped cesium iodide

Mechanical and thermal properties, not available in the literature but necessary to structural design, using thallium doped sodium iodide and sodium doped cesium iodide were determined to be coefficient of linear thermal expansion, thermal conductivity, thermal shock resistance, heat capacity, elastic constants, ultimate strengths, creep, hardness, susceptibility to subcritical crack growth, and ingot variation of strength. These properties were measured for single and polycrystalline materials at room temperature.

Forrest, K.↗

Divergence study of a high-aspect ratio, forward-swept wing

An experimental wind-tunnel study to determine the divergence characteristics of a high-aspect ratio, forward-swept wing has been conducted in the NASA Langley Research Center (LaRC) Transonic Dynamics Tunnel (TDT). The rectangular wing used for this study had a panel aspect ratio of 9.16 (lambda = 0 deg.) and the sweep angle could be set at lambda = 0 deg., -15 deg., -30 deg., -45 deg., or -60 deg. A rectangular wing tip shape was tested at each of these sweep angles. In addition, a tip shape parallel to the freestream flow was tested for a wing sweep angle of lambda = -45 deg. The root of the wing was cantilever mounted to the wall of the wind tunnel. Divergence conditions were measured at M = 0.4 for each sweep angle and tip configuration tested. Subcritical response techniques were used to extrapolate to the divergence conditions during the wind-tunnel test. The primary objective of this test was to obtain data which could be used to verify for this configuration the divergence prediction capability of an aeroelastic analysis code. Subsonic lifting surface theory (kernel function) aerodynamics are utilized by this particular code. The analytical predictions of divergence were found to be significantly conservative at all forward sweep angles. At lambda = -45 deg., the analysis was 14 percent conservative. The effect of the two tip shapes on the divergence dynamic pressure was predicted accurately by the analysis. The divergence condition for the tip shape parallel to the flow occurred at a dynamic pressure 14 percent higher than the divergence condition with a rectangular tip shape.

Cole, S. R.↗

Blunt-Body Paradox and Improved Application of Transient-Growth Framework

The “Reshotko-Tumin transition criterion" based on optimal transient growth successfully correlates laboratory measurements of roughness induced transition over blunt body configurations. Even though transient growth has not been conclusively linked to the measured onset of transition, the above correlation denotes the only available physics-based model for subcritical transition in blunt body flows, since the latter do not support any modal instabilities at typical experimental conditions. Unlike other established models based on empirical curve fits that are valid for a specific subclass of datasets, the optimal-growth-based transition criterion appears to provide a reasonable correlation with measurements in various wind tunnel and ballistic range facilities and for a broad range of surface temperature ratios. This paper is focused on optimal growth calculations that improve upon significant shortcomings of the computations underlying the Reshotko-Tumin correlation. The improved framework is applied to leeward transition over a spherical section forebody that was tested in the Mach 6 Adjustable Contour Expansion wind tunnel at Texas A&M University. The computed results highlight the significance of nonparallel basic state evolution, curvature terms, and an optimization procedure that varies both inflow and outflow locations of the transient growth interval. More important, the results indicate that the modified correlation is very close to its original form, and hence, that the accuracy of the transient-growth-based transition criterion is not compromised by using a more thorough theoretical framework. Yet the results also show that the optimal energy gain up to the predicted transition onset location can be rather small, highlighting the need to further investigate the optimal growth criterion for additional experimental configurations and to also uncover the in-depth physics underlying blunt body transition.

Freestream conditions↗

Water-tunnel study of transition flow around circular cylinders

The recently reported phenomenon of asymmetric flow separation from a circular cylinder in the critical Reynolds number regime has been confirmed in a water-tunnel experiment. For the first time, an attempt was made to visualize the wake of the cylinder during the transition from subcritical to critical flow and to correlate the visualizations with lift and drag measurements. The occurrence of a dominant asymmetric-flow state was quite repeatable, both when increasing and decreasing the Reynolds number, resulting in a mean lift coefficient of C sub L approx 1.2 and a shift in the angle of the wake by about 12 deg. A distinctive step change in the drag and shedding frequency was also found to occur. A hysteresis was confirmed to exist in this region as the Reynolds number was cycled over the transition range. Both boundaries of the asymmetry appear to be supercritical bifurcations in the flow. The asymmetry was normally steady in the mean; however, there were instances when the direction of the asymmetry reversed and remained so for the duration of the Reynolds number sweep through this transition region. A second asymmetry was observed at a higher Reynolds number; however, the mean lift coefficient was much lower, and the direction of the asymmetry was not observed to reverse. Introducing a small local disturbance into the boundary layer was found to prevent the critical asymmetry from developing along the entire span of the cylinder.

Almosnino, D.↗

Tracking performance with two breathing oxygen concentrations after high altitude rapid decompression

Current military aircraft Liquid Oxygen (LOX) systems supply 99.5 pct. gaseous Aviator's Breathing Oxygen (ABO) to aircrew. Newer Molecular Sieve Oxygen Generation Systems (MSOGS) supply breathing gas concentration of 93 to 95 pct. O2. The margin is compared of hypoxia protection afforded by ABO and MSOGS breathing gas after a 5 psi differential rapid decompression (RD) in a hypobaric research chamber. The barometric pressures equivalent to the altitudes of 46000, 52000, 56000, and 60000 ft were achieved from respective base altitudes in 1 to 1.5 s decompressions. During each exposure, subjects remained at the simulated peak altitude breathing either 100 or 94 pct. O2 with positive pressure for 60 s, followed by a rapid descent to 40000 ft. Subjects used the Tactical Life Support System (TLSS) for high altitude protection. Subcritical tracking task performance on the Performance Evaluation Device (PED) provided psychomotor test measures. Overall tracking task performance results showed no differences between the MSOGS breathing O2 concentration of 94 pct. and ABO. Significance RMS error differences were found between the ground level and base altitude trials compared to peak altitude trials. The high positive breathing pressures occurring at the peak altitudes explained the differences.

Nesthus, Thomas E.↗

IER-518: Data Analysis for High Multiplication Subcritical Experiments [Slides]

This presentation begins with a discussion of goals & motivation. This lecture then covers: experimental configurations, computational models, experimental measurements and simulations. Finally, this presentation concludes with data analysis & results plus a conclusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Droplet-turbulence interactions in sprays exposed to supercritical environmental conditions

The goal of this research was to experimentally characterize the behavior of droplets in vaporizing sprays under conditions typical of those encountered in high pressure combustion systems such as liquid fueled rocket engines. Of particular interest are measurements of droplet drag and lift, droplet dispersion, droplet heating, and droplet vaporization under both subcritical and supercritical conditions. A summary of the major accomplishments achieved during the period from June 1990 through June 1993, a brief description and status report on five research areas, which were directly or indirectly supported by this grant, and a list of publications and personnel associated with this research is included.

Santavicca, Domenic A.↗

AN OVERVIEW OF THE DESIGN AND PERFORMANCE TESTING OF A 275 BAR INTEGRALLY GEARED SUPERCRITICAL CO2 COMPRESSOR FOR POWER GENERATION

An integrally geared compressor-expander (compander) for supercritical CO2 (sCO2) was developed to convert thermal energy to electricity. With operating pressures of 275 bar, this turbomachine represents the state of the art in integrally geared machine architecture, hitting compressor inlet densities of 600 kg/m3 and discharge pressures of 275 bar. The product development was funded by the Department of Energy’s Energy Efficiency and Renewable Energy Office under EE0007114 to advance the state of the art in concentrated solar power applications; however, the technology itself is agnostic to heat source, and is predicted to achieve a thermal-to-electric conversion efficiency of 50% for any indirect heat source capable of providing turbine inlet temperatures of 700°C or greater. While the program encompassed the design and testing for the compressor and turbine elements, this paper will focus on the compressor design and operation. The paper will begin with an introduction to the cycle design and analysis of an indirectly heated integrally geared sCO2 compander, a discussion of the mechanical and aerodynamic design of the compressor that is a two stage radial compressor operating subcritically at 27,512 rpm, and will then proceed to describe the test facility and measured data to characterize the performance and robustness of the machine. The paper will conclude with a discussion on lessons learned throughout the course of commissioning and testing. Practical aspects of testing a compressor operating near the dome including complications relating to obtaining an accurate compressor flow map, efficiency calculations, flow unsteadiness, and associated measurement uncertainties will be discussed.

wilkes, jason↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

TRIPOLI-4 neutronics calculations for IAEA-CRP benchmark of CEFR start-up tests using new libraries JEFF-3.3 and ENDF/B-VIII

Sodium-cooled Fast Reactors (SFR) are one of the promising Generation IV fast reactors. The China Experimental Fast Reactor (CEFR) is a 65 MWth pool-type SFR with a high neutron leakage core using high enriched uranium oxide fuel. The CEFR start-up tests in 2010 consist of series of neutronics experiments. Essential experimental data are available from the 2018 IAEA-CEFR-CRP benchmark document and useful for the validation of neutron transport codes and nuclear data libraries. The TRIPOLI-4 Monte Carlo transport code is a general-purpose neutronics code using continuous-energy nuclear data libraries. It has a rich validation database covering different computational and experimental benchmark data sets to assure the accuracy and credibility of numerical studies. Previous TRIPOLI-4 SFR core physics calculations used mainly MOX fuels. SFR control rod worth studies with TRIPOLI-4 were mainly on big-size cores. To test the modeling capability of TRIPOLI-4 on fuel loading patterns and on variable control rods positions for SFRs and to check recent nuclear data libraries, it is interesting to investigate the CEFR start-up tests in this work, including core states from subcritical to supercritical, control rods and rod group worth, point kinetics parameters, and radial foil activation measurements. TRIPOLI-4 calculation results using new data libraries JEFF-3.3, ENDF/B-VIII, and those of ENDF/B-VII.1 for different CEFR core states are reported here. By means of different options of TRIPOLI-4, control-rod SAs reactivity worth, point kinetics parameters, and radial {sup 237}Np(n,f) fission rate distribution were successfully evaluated. Both ENDF/B-VIII and JEFF-3.3 nuclear data libraries provided reliable results with a difference of 170 +/- 11 pcm in k{sub eff}.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaporation of LOX under supercritical and subcritical conditions

The evaporation of LOX under supercritical and subcritical conditions was studied experimentally and theoretically. In experiments, the evaporation rate and surface temperature were measured for LOX strand vaporizing in helium environments at pressures ranging from 5 to 68 atmospheres. Gas sampling and chromatography analysis were also employed to profile the gas composition above the LOX surface for the purpose of model validation. A comprehensive theoretical model was formulated and solved numerically to simulate the evaporation process of LOX at high pressures. The model was based on the conservation equations of mass, momentum, energy, and species concentrations for a multicomponent system, with consideration of gravitational body force, solubility of ambient gases in liquid, and variable thermophysical properties. Good agreement between predictions and measured oxygen mole fraction profiles was obtained. The effect of pressure on the distribution of the Lewis number, as well as the effect of variable diffusion coefficient, were further examined to elucidate the high-pressure transport behavior exhibited in the LOX vaporization process.

Yang, A. S.↗

Comparison of effect of a turbojet engine and three cold-flow configurations on the stability of a full-scale supersonicle inlet

Increasing the volume and length of the duct behind the inlet affected the inlet stability at Mach 2.0 and zero angle of attack. Close approximation of the inlet stability limit of the J34 engine-inlet configuration was obtained by a cold-pipe configuration having a length and volume approaching that measured to the engine turbine. Variation of these parameters had a small effect on the minimum subcritical stable mass flow below a cowl-lip-position parameter of 44 degrees and appeared to have a negligible effect on the inlet pressure-recovery - mass-flow curve. Initial buzz frequency and minimum cowl-lip-position parameter for complete buzz-free operation varied with configuration.

Musial, Norman T↗

Evaporation and combustion of LOX under supercritical and subcritical conditions

The objective is to study the evaporation and combustion of LOX under supercritical and subcritical conditions both experimentally and theoretically. In the evaporation studies, evaporation rate and surface temperature were measured when LOX vaporizing in helium environments at pressures ranging from 5 to 68 atm. A Varian 3700 gas chromatograph was employed to measure the oxygen concentration above the LOX surface. For the combustion tests, high-magnification video photography was used to record direct images of the flame shape of a LOX/H2/He laminar diffusion flame. The gas composition in the post-flame region is also being measured with the gas sampling and chromatography analysis. These data are being used to validate the theoretical model. A comprehensive theoretical model with the consideration of the solubility of ambient gases as well as variable thermophysical properties was formulated and solved numerically to study the gasification and burning of LOX at elevated pressures. The calculated flame shape agreed reasonably well with the edge of the observed luminous flame surface. The effect of gravity on the flame structure of laminar diffusion flames was found to be significant. In addition, the predicted results using the flame-sheet model were compared with those based upon full equilibrium calculations (which considered the formation of intermediate species) at supercritical pressures. Except at the flame front where temperature exceeded 2,800 K, the flame-sheet and equilibrium solutions in terms of temperature distributions were in very close agreement. The temperature deviation in the neighborhood of the flame front is caused by the effect of high-temperature dissociation.

Yang, A. S.↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence 3 - Raw Data

Sequence 3: Tower Wake Measure (P) Sequence 3 used a downwind, rigid turbine with a 3.4° cone angle. The wind speeds for this sequence corresponded to subcritical [7 m/s], transitional [15 m/s], and supercritical [20 m/s] Reynolds number regimes for the circular cross-section tower. The yaw angle and blade tip pitch angles were selected to traverse the probe tip across the tower wake, while keeping the probe axis approximately parallel to the tunnel centerline. The rotor was parked with the instrumented blade at 180° azimuth. Blade and probe pressure measurements were collected.

17 WIND ENERGY↗

Dynamic Modeling, Parameter Estimation, and Data Reconciliation of a Supercritical Pulverized Coal-Fired Boiler

A high-fidelity, spatially distributed dynamic model of a supercritical pulverized coal-fired boiler was developed for calculating transient thermal profiles of the boiler tubes, which are often not measured or unmeasurable in industrial settings due to the harsh operating conditions. In this work, rigorous models of the subcritical and supercritical steam properties, which can be highly nonlinear, were used to capture the transition between two-phase and one-phase flow, respectively, as supercritical boilers frequently transition through the critical point during load-following operation. The transient boiler model was also used for data reconciliation and parameter estimation for the purpose of model validation against industrial data. An approach was developed to reduce the size of large-scale reconciliation problem by focusing on the implementation of bias terms for the reconciled variables, which can be estimated in place of the reconciled variables themselves. In addition, a functional approximation of the reconciliation problem was defined so that it can be more simply optimized. Combining this functional approximation optimization with reformulation of the reconciliation problem considering measurement biases can significantly improve the tractability of many such large-scale problems. The validated boiler model was then used to study transient responses under load-following operation with specific attention on the calculation of unmeasurable variables.

42 ENGINEERING↗