Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Strips”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Tension‐Induced Cavitation in Li‐Metal Stripping

Abstract Designing stable Li metal and supporting solid structures (SSS) is of fundamental importance in rechargeable Li‐metal batteries. Yet, the stripping kinetics of Li metal and its mechanical effect on the supporting solids (including solid electrolyte interface) remain mysterious to date. Here, through nanoscale in situ observations of a solid‐state Li‐metal battery in an electron microscope, two distinct cavitation‐mediated Li stripping modes controlled by the ratio of the SSS thickness ( t ) to the Li deposit's radius ( r ) are discovered. A quantitative criterion is established to understand the damage tolerance of SSS on the Li‐metal stripping pathways. For mechanically unstable SSS ( t / r < 0.21), the stripping proceeds via tension‐induced multisite cavitation accompanied by severe SSS buckling and necking, ultimately leading to Li “trapping” or “dead Li” formation; for mechanically stable SSS ( t / r > 0.21), the Li metal undergoes nearly planar stripping from the root via single cavitation, showing negligible buckling. This work proves the existence of an electronically conductive precursor film coated on the interior of solid electrolytes that however can be mechanically damaged, and it is of potential importance to the design of delicate Li‐metal supporting structures to high‐performance solid‐state Li‐metal batteries.

36 MATERIALS SCIENCE↗

Smooth Contact of a Semiinfinite Punch with Rounded Edge and an Elastic Strip

We consider a problem of contact of an elastic strip with a semiinfinite punch with rounded edge indented into one face of the strip, while the other face of the strip is fixed. Friction forces in the contact zone are neglected. By the Wiener–Hopf method, we obtain the exact analytic solution of the problem. The distributions of contact stresses, the stresses inside the strip and along its fixed face, and the normal displacements of points of a part of the load-free face of the strip are determined. We construct the isochores and determine the position of the point at which the maximum values of the principal shear stresses are attained.

42 ENGINEERING↗

Large-scale metal strip for power storage and energy conversion applications by machining-based deformation processing

Machining-based deformation processing is used to produce metal foil and flat wire (strip) with suitable properties and quality for electrical power and renewable energy applications. In contrast to conventional multistage rolling, the strip is produced in a single-step and with much less process energy. Examples are presented from metal systems of varied workability, and strip product scale in terms of size and production rate. By utilizing the large-strain deformation intrinsic to cutting, bulk strip with ultrafine-grained microstructure, and crystallographic shear-texture favourable for formability, are achieved. In conclusion, implications for production of commercial strip for electric motor applications and battery electrodes are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Development Of Chemical Reduction And Air Stripping Processes To Remove Mercury From Wastewater

This study evaluates the removal of mercury from wastewater using chemical reduction and air stripping using a full-scale treatment system at the Savannah River Site. The existing water treatment system utilizes air stripping as the unit operation to remove organic compounds from groundwater that also contains mercury (C ~ 250 ng/L). The baseline air stripping process was ineffective in removing mercury and the water exceeded a proposed limit of 51 ng/L. To test an enhancement to the existing treatment modality a continuous dose of reducing agent was injected for 6-hours at the inlet of the air stripper. This action resulted in the chemical reduction of mercury to Hg(0), a species that is removable with the existing unit operation. During the injection period a 94% decrease in concentration was observed and the effluent satisfied proposed limits. The process was optimized over a 2-day period by sequentially evaluating dose rates ranging from 0.64X to 297X stoichiometry. A minimum dose of 16X stoichiometry was necessary to initiate the reduction reaction that facilitated the mercury removal. Competing electron acceptors likely inhibited the reaction at the lower 1 doses, which prevented removal by air stripping. These results indicate that chemical reduction coupled with air stripping can effectively treat large-volumes of water to emerging part per trillion regulatory standards for mercury.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced absorption of graphene strips with a multilayer subwavelength grating structure

The optical absorption of graphene strips covered on a multilayer subwavelength grating (MSG) surface is theoretically investigated. The absorption of graphene strips with MSG is enhanced in the wavelength range of 1500 nm to 1600 nm by critical coupling, which is associated with the combined effects of a guided resonance of MSG and its photonic band gap effect. The critical coupling of the graphene strips can be controlled by adjusting the incident angle without changing the structural parameters of MSG. The absorption of graphene strips can also be tuned by varying key parameters, such as grating period, strip width, and incident angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasmonic excitation-assisted optical and electric enhancement in ultra-thin solar cells: the influence of nano-strip cross section

The effects of Ag nano-strips with triangle, rectangular and trapezoid cross sections on the optical absorption, generation rate, and short-circuit current density of ultra-thin solar cells were investigated. By putting the nano-strips as a grating structure on the top of the solar cells, the waveguide, surface plasmon polariton (SPP), and localized surface plasmon (LSP) modes, which are excited with the assistance of nano-strips, were evaluated in TE and TM polarizations. The results show, firstly, the TM modes are more influential than TE modes in optical and electrical properties enhancement of solar cell, because of plasmonic excitations in TM mode. Secondly, the trapezoid nano-strips reveal noticeable impact on the optical absorption, generation rate, and short-circuit current density enhancement than triangle and rectangular ones. In particular, the absorption of long wavelengths which is a challenge in ultra-thin solar cells is significantly improved by using Ag trapezoid nano-strips.

36 MATERIALS SCIENCE↗

A phononic crystal strip based on silicon for support tether applications in silicon-based MEMS resonators and effects of temperature and dopant on its band gap characteristics

Phononic crystals (PnCs) and n-type doped silicon technique have been widely employed in silicon-based MEMS resonators to obtain high quality factor (Q) as well as temperature-induced frequency stability. For the PnCs, their band gaps play an important role in the acoustic wave propagation. Also, the temperature and dopant doped into silicon can cause the change in its material properties such as elastic constants, Young’s modulus. Therefore, in order to design the simultaneous high Q and frequency stability silicon-based MEMS resonators by two these techniques, a careful design should study effects of temperature and dopant on the band gap characteristics to examine the acoustic wave propagation in the PnC. Based on these, this paper presents (1) a proposed silicon-based PnC strip structure for support tether applications in low frequency silicon-based MEMS resonators, (2) influences of temperature and dopant on band gap characteristics of the PnC strips. The simulation results show that the largest band gap can achieve up to 33.56 at 57.59 MHz and increase 1280.13 % (also increase 131.89 % for ratio of the widest gaps) compared with the counterpart without hole. The band gap properties of the PnC strips is insignificantly effected by temperature and electron doping concentration. Also, the quality factor of two designed length extensional mode MEMS resonators with proposed PnC strip based support tethers is up to 1084.59% and 43846.36% over the same resonators with PnC strip without hole and circled corners, respectively. This theoretical study uses the finite element analysis in COMSOL Multiphysics and MATLAB softwares as simulation tools. This findings provides a background in combination of PnC and dopant techniques for high performance silicon-based MEMS resonators as well as PnC-based MEMS devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic triggering — time-resolved characterisation of silicon strip modules in the presence of switching DC-DC converters

Modules for the ATLAS Inner Tracker (ITk) strip tracker include a DC-DC converter circuit glued directly to the silicon sensor which converts the 11 V supplied to the module to the 1.5 V required for the operation of the readout chips. The DC-DC converter unit, consisting of a copper solenoid and custom ASIC, is located directly above the silicon strip sensor and therefore needs to be shielded to protect the sensor from EMI noise created during the operation of the circuit. Despite dedicated shielding, consisting of an aluminium shield box with continuous solder seams encompassing the surface components and a copper layer in the PCB beneath it, module channels connected to sensor strips located beneath the converter circuit were found to show a noise increase. While the DC-DC converter unit causing the underlying EMI noise operates at a frequency of 2 MHz, module characterisation measurements for ITk strip tracker modules are typically performed asynchronously to the DC-DC switching and are therefore averaged over the full range of time bins with respect to the converter frequency. In order to investigate the time dependence of the noise injection relative to the DC-DC switching frequency, a dedicated setup to understand the time-resolved performance change in modules was developed. By using a magnetic field probe to measure the field leaking through the shield box and triggering on its rising edge, data taking could be synchronised with the DC-DC switching. This paper illustrates the concept and setup of such time-resolved performance measurements using magnetic triggering and presents results for the observed effects on signal and noise for ATLAS ITk strip modules from both laboratory and beam tests.

47 OTHER INSTRUMENTATION↗

ATLAS ITk strip sensor quality control procedures and testing site qualification

Abstract The high-luminosity upgrade of the Large Hadron Collider, scheduled to become operational in 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker. Radiation hard n + -in-p micro-strip silicon sensors were developed by the ATLAS Inner Tracker strip collaboration and are produced by Hamamatsu Photonics K.K. Production of the total amount of 22000 strip sensors has started in 2020 and will continue until 2025. The ATLAS strip sensor collaboration has the responsibility to monitor the quality of the fabricated devices by performing detailed measurements of individual sensor characteristics and by comparing the obtained results with the tests done by the manufacturer. Dedicated Quality Control procedures were developed to check whether the delivered large-format sensors adhere to the ATLAS specifications. The institutes performing the Quality Control testing of the pre-production and production ATLAS ITk strip sensors had to initially be qualified for multiple high-throughput tests by successfully completing the Site Qualification process. The Quality Control procedures and the qualification process are described in this paper.

Instruments & Instrumentation↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

An extreme thermal cycling reliability test of ATLAS ITk Strips barrel modules

At the end of Run 3 of the Large Hadron Collider (LHC), the accelerator complex will be upgraded to the High-Luminosity LHC (HL-LHC) in order to increase the total amount of data provided to its experiments. To cope with the increased rates of data, radiation, and pileup, the ATLAS detector will undergo a substantial upgrade, including a replacement of the Inner Detector with a future Inner Tracker, called the ITk. The ITk will be composed of pixel and strip sub-detectors, where the strips portion will be composed of 17,888 silicon strip detector modules. During the HL-LHC running period, the ITk will be cooled and warmed a number of times from about -35°C to room temperature as part of the operational cycle, including warm-ups during yearly shutdowns. To ensure ITk Strips modules are functional after these expected temperature changes, and to ensure modules are mechanically robust, each module must undergo ten thermal cycles and pass a set of electrical and mechanical criteria before it is placed on a local support structure. This paper describes the thermal cycling Quality Control (QC) procedure, and results from the barrel pre-production phase (about 5% of the production volume). Additionally, in order to assess the headroom of the nominal QC procedure of 10 cycles and to ensure modules don't begin failing soon after, four representative ITk Strips barrel modules were thermally cycled 100 times — this study is also described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RESULTS FROM ANALYSIS OF THE FIRST AND SECOND STRIP EFFLUENT COALESCER ELEMENTS FROM RADIOACTIVE OPERATIONS OF THE MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT

The coalescer elements for the Strip Effluent (SE) acid within the Modular Caustic-Side Solvent Extraction Unit (MCU) experienced elevated differential pressure drop during radioactive operations. Following the end of operations for the first Macrobatch campaign and soon after start of the second Macrobatch campaign, personnel removed the coalescer media and provided to Savannah River National Laboratory (SRNL) for diagnostic investigation of the causes of reduced flow. This report summarizes those studies. Two Strip Effluent (SE) coalescers were delivered to the Savannah River National Laboratory (SRNL). One was removed from the Modular Caustic-Side Solvent Extraction Unit (MCU) between processing of Macrobatch 1 and 2 (coalescer 'Alpha'), and the second was removed from MCU after processing of {approx}24,000 gallons of salt solution (coalescer 'Beta'). Both coalescers underwent the same general strip acid flush program to reduce the dose and were delivered to SRNL for analysis of potential occluding solids. Analysis of Coalescer Alpha indicates the presence of aluminum hydroxide solids and aluminosilicate solids, while analysis of Coalescer Beta indicates the presence of aluminum hydroxide solids, but no aluminosilicates. Leaching studies on sections of both coalescers were performed. The results indicate that the coalescers had different amounts of solids present on them at the time of removal. Finally, samples of free liquids retrieved from both coalescers indicate no excessive amounts of CSSX solvent present. Given the strip acid flushing that occurred in the SE coalescers, the solids we detected on the coalescers are probably indicative of a larger quantity of these solids present before the strip acid flushing. Under this scenario, the excessive pressure drops are due to the solids and not from organic fouling.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mo-99 Stripping Results and Column Designs for Mini-Medical Isotope Production System (MIPS)

Results from the column tests performed by using small volumes of irradiated solutions as tracers for depleted uranium (DU) solutions containing stable molybdenum (Mo) as Na 2 MoO 4 forced us to investigate the stripping parameters needed to obtain full Mo recovery. In an effort to optimize the stripping conditions, several column runs were done by using either 1 M NaOH or NH 4 OH as the stripping agent at different velocities. Overall, we obtained very inconsistent results that suggest stripping velocity does not affect Mo recovery as much as originally believed. In addition, we generated 0.1 M HNO 3 breakthrough curves after each run to determine if the performance of the column was changing. Future experiments will utilize columns packed with fresh sorbent after each run. The column designs for the mini-MIPS 5-liter (L) and 20-L experiments employed data obtained from using several different S80 columns at different loading, washing, and stripping velocities. Data were input into the VERSE code, and plant-scale column designs were generated. The mini-MIPS column designs and parameters are a direct downscale of the plant operation, where full Mo adsorption and recovery are expected.

Youker, Amanda J.↗

Bench-Scale Development of a Hot Carbonate Absorption Process with Crystallization-Enabled High-Pressure Stripping for Post-Combustion CO 2 Capture (Final Scientific/Technical Report)

A novel Hot Carbonate Absorption Process with Crystallization-Enabled High-Pressure Stripping (Hot-CAP) has been developed by the University of Illinois at Urbana-Champaign and Carbon Capture Scientific, LLC in this three-year, bench-scale project. The Hot-CAP features a concentrated carbonate solution (e.g., K 2 CO 3 ) for CO 2 absorption and a bicarbonate slurry (e.g., KHCO 3 ) for high-pressure CO 2 stripping to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy use and cost competitiveness over MEA. To meet project goals and objectives, a combination of experimental, modeling, process simulation, and economic analysis studies were applied. Carefully designed and intensive experiments were conducted to measure thermodynamic and reaction engineering data relevant to four major unit operations in the Hot-CAP (i.e., CO 2 absorption, CO 2 stripping, bicarbonate crystallization, and sulfate reclamation). The rate promoters that could accelerate the CO 2 absorption rate into the potassium carbonate/bicarbonate (PCB) solution to a level greater than that into the 5 M MEA solution were identified, and the superior performance of CO 2 absorption into PCB was demonstrated in a bench-scale packed-bed column. Kinetic data on bicarbonate crystallization were developed and applied for crystallizer design and sizing. Parametric testing of high-pressure CO 2 stripping with concentrated bicarbonate-dominant slurries at high temperatures (≥140°C) in a bench-scale stripping column demonstrated lower heat use than with MEA. The feasibility of a modified process for combining SO 2 removal with CO 2 capture was preliminarily demonstrated. In addition to the experimental studies, the technical challenges pertinent to fouling of slurry-handling equipment and the design of the crystallizer and stripper were addressed through consultation with vendors and engineering analyses. A process flow diagram of the Hot-CAP was then developed and a TEA was performed to compare the energy use and cost performance of a nominal 550-MWe subcritical pulverized coal (PC)-fired power plant without CO 2 capture (DOE/NETL Case 9) with the benchmark MEA-based post-combustion CO 2 capture (PCC; DOE/NETL Case 10) and the Hot-CAP-based PCC. The results revealed that the net power produced in the PC + Hot-CAP is 609 MWe, greater than the PC + MEA (550 MWe). The 20-year levelized cost of electricity (LCOE) for the PC + Hot-CAP, including CO 2 transportation and storage, is 120.3 mills/kWh, a 60% increase over the base PC plant without CO 2 capture. The LCOE increase for the Hot-CAP is 29% lower than that for MEA. TEA results demonstrated that the Hot-CAP is energy-efficient and cost-effective compared with the benchmark MEA process.

54 ENVIRONMENTAL SCIENCES↗

Pixel-Strip Module Testing and Performance Analysis for the CMS Phase-2 Outer Tracker Upgrade

In response to the demanding environment of the High-Luminosity Large Hadron Collider (HL-LHC), the Compact Muon Solenoid (CMS) Experiment's Outer Tracker is being replaced with a lighter, higher-granularity, radiation-tolerant silicon detector capable of providing tracking information directly to the Level-1 trigger system. The new Outer Tracker consists of Pixel-Strip (PS) and Strip-Strip (2S) transverse momentum (pT) modules, which are assembled and tested at, among other centers, Fermilab's Silicon Detector Facility. PS modules consist of a pixel sensor, a strip sensor, and multiple application-specific integrated circuits (ASICs). This poster studies the performance of MaPSAs, silicon macro-pixel sensors bump-bonded to 16 macro-pixel ASICS. It presents the testing procedures for MaPSAs and MaPSA-strip sensor sub-assemblies, as well as the results of calibration and performance studies of two PS modules before and after irradiation. These results assess the impact of irradiation on module performance, providing insight into the modules' expected performance in the HL-LHC environment.

Kimrey, Emerson [Scripps College]↗

ANALYZING THE LARGEST SPECTROSCOPIC DATA SET OF STRIPPED SUPERNOVAE TO IMPROVE THEIR IDENTIFICATIONS AND CONSTRAIN THEIR PROGENITORS

Using the largest spectroscopic data set of stripped-envelope core-collapse supernovae (stripped SNe), we present a systematic investigation of spectral properties of Type IIb SNe (SNe IIb), Type Ib SNe (SNe Ib), and Type Ic SNe (SNe Ic). Prior studies have been based on individual objects or small samples. Here, we analyze 242 spectra of 14 SNe IIb, 262 spectra of 21 SNe Ib, and 207 spectra of 17 SNe Ic based on the stripped SN data set of Modjaz et al. and other published spectra of individual SNe. Each SN in our sample has a secure spectroscopic ID, a date of V -band maximum light, and most have multiple spectra at different phases. We analyze these spectra as a function of subtype and phase in order to improve the SN identification scheme and constrain the progenitors of different kinds of stripped SNe. By comparing spectra of SNe IIb with those of SNe Ib, we find that the strength of H α can be used to quantitatively differentiate between these two subtypes at all epochs. Moreover, we find a continuum in observational properties between SNe IIb and Ib. We address the question of hidden He in SNe Ic by comparing our observations with predictions from various models that either include hidden He or in which He has been burnt. Our results favor the He-free progenitor models for SNe Ic. Finally, we construct continuum-divided average spectra as a function of subtype and phase to quantify the spectral diversity of the different types of stripped SNe.

79 ASTRONOMY AND ASTROPHYSICS↗