Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stimulus responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Root gravitropism: a complex response to a simple stimulus?

Roots avoid depleting their immediate environment of essential nutrients by continuous growth. Root growth is directed by environmental cues, including gravity. Gravity sensing occurs mainly in the columella cells of the root cap. Upon reorientation within the gravity field, the root-cap amyloplasts sediment, generating a physiological signal that promotes the development of a curvature at the root elongation zones. Recent molecular genetic studies in Arabidopsis have allowed the identification of genes that play important roles in root gravitropism. Among them, the ARG1 gene encodes a DnaJ-like protein involved in gravity signal transduction, whereas the AUX1 and AGR1 genes encode proteins involved in polar auxin transport. These studies have important implications for understanding the intra- and inter-cellular signaling processes that underlie root gravitropism.

Review, Tutorial↗

Use of Otoacousticemission Phase Change to Evaluate Countermeasures for Spaceflight-Associated Neuro-Ocular Syndrome

Spaceflight-associated neuro-ocular syndrome (SANS) is a human spaceflight risk recognized by NASA. Elevated intracranial pressure (ICP) has been implicated as a root cause of many SANS signs and symptoms, yet there is no reliable noninvasive means of monitoring ICP. We have developed a noninvasive method of monitoring ICP change that exploits ear canal acoustic and otoacoustic emission (OAE) measurements. Changed ICP alters pressure in the inner ear, leading to changes in the tension and position of middle ear (ME) components; tension of these components determines the phase of the stimulus in the ear canal and the OAE response sound transmission back through the ME. The OAE method has been validated in several studies, including our own experiments as part of the NASA Fluid Shifts study. Systematic OAE phase changes demonstrating increased ME tension (an ICP indicator) are observed as posture is changed from seated to supine to head-down tilt (HDT). This effect can be substantially mitigated by lower body negative pressure (LBNP). The OAE technique has also been used on International Space Station (ISS) crewmembers, providing evidence that ICP in microgravity is similar to that seen on the ground in the supine position. The OAE method is also a rapid and noninvasive means of assessing the effectiveness of SANS countermeasures. Here we report results from two studies which used OAEs. In the most recent study (Venous Congestion Countermeasures - VCCM), three promising countermeasures [LBNP, an impedance threshold device (ITD), and veno-occlusive thigh cuffs (VTC)] were applied individually and in combination. In our previous ITD-only study, ITD was investigated for its ability to reduce ICP and cephalic venous congestion in supine and various HDT postures. Internal jugular vein (IJV) ultrasound showed a clear decongestive effect at all postures, however OAE data showed that ITD only caused a phase decrease (tension decrease) in HDT postures. In supine, ITD appeared to INCREASE tension. This paradox leads us to hypothesize that the OAE method is not accurately representing ICP changes with countermeasures (CM), which can alter ME tension through other means, such as ME pressure (MEP) changes. More generally, the exact mechanism for observed OAE response and stimulus phase shifts are not clearly understood, specifically with regard to the effects of MEP. The VCCM study examined the effects of externally-applied MEP on OAE recordings to document the relationship between these parameters. Analysis of these data provide new insights to these OAE mechanisms, in addition to results on CM effectiveness.

Kemp, D.↗

Evaluating Daily Load Stimulus Formulas in Relating Bone Response to Exercise

Six formulas representing what is commonly referred to as "daily load stimulus" are identified, compared and tested in their ability to relate skeletal mechanical loading to bone maintenance and osteogenic response. Particular emphasis is placed on exercise- induced skeletal loading and whether or not the formulas can adequately capture the known experimental observations of saturation of continuous cyclic loading, rest insertion between repetitions (cycles), recovery of osteogenic potential following saturation, and multiple shorter bouts versus a single long bout of exercise. To evaluate the ability of the formulas to capture these characteristics, a set of exercise scenarios with type of exercise bout, specific duration, number of repetitions, and rest insertion between repetitions is defined. The daily load values obtained from the formulas for the loading conditions of the set of scenarios is illustrated. Not all of the formulas form estimates of daily load in units of stress or in terms of strain at a skeletal site due to the loading force from a specific exercise prescription. The comparative results show that none of the formulas are able to capture all of the experimentally observed characteristics of cyclic loading. However, the enhanced formula presented by Genc et al. does capture several characteristics of cyclic loading that the others do not, namely recovery of osteogenic potential and saturation. This could be a basis for further development of mathematical formulas that more adequately approximates the amount of daily stress at a skeletal site that contributes to bone adaptation.

Pennline, James A.↗

Brainstem auditory evoked responses in man. 1: Effect of stimulus rise-fall time and duration

Short latency (under 10 msec) responses elicited by bursts of white noise were recorded from the scalps of human subjects. Response alterations produced by changes in the noise burst duration (on-time), inter-burst interval (off-time), and onset and offset shapes were analyzed. The latency of the most prominent response component, wave V, was markedly delayed with increases in stimulus rise time but was unaffected by changes in fall time. Increases in stimulus duration, and therefore in loudness, resulted in a systematic increase in latency. This was probably due to response recovery processes, since the effect was eliminated with increases in stimulus off-time. The amplitude of wave V was insensitive to changes in signal rise and fall times, while increasing signal on-time produced smaller amplitude responses only for sufficiently short off-times. It was concluded that wave V of the human auditory brainstem evoked response is solely an onset response.

Hecox, K.↗

The adequate stimulus for avian short latency vestibular responses to linear translation

Transient linear acceleration stimuli have been shown to elicit eighth nerve vestibular compound action potentials in birds and mammals. The present study was undertaken to better define the nature of the adequate stimulus for neurons generating the response in the chicken (Gallus domesticus). In particular, the study evaluated the question of whether the neurons studied are most sensitive to the maximum level of linear acceleration achieved or to the rate of change in acceleration (da/dt, or jerk). To do this, vestibular response thresholds were measured as a function of stimulus onset slope. Traditional computer signal averaging was used to record responses to pulsed linear acceleration stimuli. Stimulus onset slope was systematically varied. Acceleration thresholds decreased with increasing stimulus onset slope (decreasing stimulus rise time). When stimuli were expressed in units of jerk (g/ms), thresholds were virtually constant for all stimulus rise times. Moreover, stimuli having identical jerk magnitudes but widely varying peak acceleration levels produced virtually identical responses. Vestibular response thresholds, latencies and amplitudes appear to be determined strictly by stimulus jerk magnitudes. Stimulus attributes such as peak acceleration or rise time alone do not provide sufficient information to predict response parameter quantities. Indeed, the major response parameters were shown to be virtually independent of peak acceleration levels or rise time when these stimulus features were isolated and considered separately. It is concluded that the neurons generating short latency vestibular evoked potentials do so as "jerk encoders" in the chicken. Primary afferents classified as "irregular", and which traditionally fall into the broad category of "dynamic" or "phasic" neurons, would seem to be the most likely candidates for the neural generators of short latency vestibular compound action potentials.

NASA Discipline Neuroscience↗

Brainstem auditory evoked responses in man. 1: Effect of stimulus rise-fall time and duration

Short latency (under 10 msec) evoked responses elicited by bursts of white noise were recorded from the scalp of human subjects. Response alterations produced by changes in the noise burst duration (on-time) inter-burst interval (off-time), and onset and offset shapes are reported and evaluated. The latency of the most prominent response component, wave V, was markedly delayed with increases in stimulus rise-time but was unaffected by changes in fall-time. The amplitude of wave V was insensitive to changes in signal rise-and-fall times, while increasing signal on-time produced smaller amplitude responses only for sufficiently short off-times. It is concluded that wave V of the human auditory brainstem evoked response is solely an onset response.

Hecox, K.↗

A quantitative method for studying human arterial baroreflexes

A new system is described that delivers precise, stereotyped pressure changes to the human neck and elicits neurally-mediated heart rate changes. The centerpiece of this system is a Silastic chamber that is strapped to the anterior neck. This chamber is connected to a stepping-motor-controlled bellows assembly. A strain-gauge transducer measures the intensity of pressure changes. The entire system is controlled by microprocessors, and both stimuli and responses are displayed on a digital oscilloscope. The end-product of this system is a reproducible baroreceptor stimulus-cardiac response relation that can be recorded rapidly and safely in astronauts in space.

Eckberg, Dwain L.↗

Response Classification Images in Vernier Acuity

Orientation selective and local sign mechanisms have been proposed as the basis for vernier acuity judgments. Linear image features contributing to discrimination can be determined for a two choice task by adding external noise to the images and then averaging the noises separately for the four types of stimulus/response trials. This method is applied to a vernier acuity task with different spatial separations to compare the predictions of the two theories. Three well-practiced observers were presented around 5000 trials of a vernier stimulus consisting of two dark horizontal lines (5 min by 0.3 min) within additive low-contrast white noise. Two spatial separations were tested, abutting and a 10 min horizontal separation. The task was to determine whether the target lines were aligned or vertically offset. The noises were averaged separately for the four stimulus/response trial types (e.g., stimulus = offset, response = aligned). The sum of the two 'not aligned' images was then subtracted from the sum of the 'aligned' images to obtain an overall image. Spatially smoothed images were quantized according to expected variability in the smoothed images to allow estimation of the statistical significance of image features. The response images from the 10 min separation condition are consistent with the local sign theory, having the appearance of two linear operators measuring vertical position with opposite sign. The images from the abutting stimulus have the same appearance with the two operators closer together. The image predicted by an oriented filter model is similar, but has its greatest weight in the abutting region, while the response images fall to nonsignificance there. The response correlation image method, previously demonstrated for letter discrimination, clarifies the features used in vernier acuity.

Ahumada, Albert J., Jr.↗

Enhanced carotid-cardiac baroreflex response and elimination of orthostatic hypotension 24 hours after acute exercise in paraplegics

To test the hypothesis that an acute bout of maximal exercise can ameliorate orthostatic hypotension consequent to prolonged wheelchair confinement, we evaluated heart rate (HR), systolic (SBP) and diastolic (DBP) blood pressure responses during 15 minutes of 70 degrees head-up tilt (HUT) in 10 paraplegic subjects 24 hours after arm crank exercise designed to elicit maximal effort, and during a control (no exercise) conditions. Additionally, the carotid baroreceptor stimulus-cardiac response relationship was determined by measurement of R-R interval during external application of graded pressures to the carotid sinuses. One week separated the treatment conditions. The maximum slope of the carotid-cardiac baroreflex response was increased (p = 0.049) by exercise (6.2 +/- 1.7 msec/mmHg) compared to control (3.3 +/- 0.6). During control HUT, HR increased from 61 +/- 1 to 90 +/- 7 bpm (p = 0.001) while SBP decreased from 118 +/- 5 to 106 +/- 9 mmHg (p = 0.025). During HUT 24 hours after exercise, HR increased from 60 +/- 2 to 90 +/- 4 bpm (p = 0.001), but the reduction in SBP was essentially eliminated (116 +/- 5 to 113 +/- 5 mmHg).

Engelke, K. A.↗

A Bayesian Approach to Estimating Coupling Between Neural Components: Evaluation of the Multiple Component, Event-Related Potential (mcERP) Algorithm

Accurate measurement of single-trial responses is key to a definitive use of complex electromagnetic and hemodynamic measurements in the investigation of brain dynamics. We developed the multiple component, Event-Related Potential (mcERP) approach to single-trial response estimation. To improve our resolution of dynamic interactions between neuronal ensembles located in different layers within a cortical region and/or in different cortical regions. The mcERP model assets that multiple components defined as stereotypic waveforms comprise the stimulus-evoked response and that these components may vary in amplitude and latency from trial to trial. Maximum a posteriori (MAP) solutions for the model are obtained by iterating a set of equations derived from the posterior probability. Our first goal was to use the ANTWERP algorithm to analyze interactions (specifically latency and amplitude correlation) between responses in different layers within a cortical region. Thus, we evaluated the model by applying the algorithm to synthetic data containing two correlated local components and one independent far-field component. Three cases were considered: the local components were correlated by an interaction in their single-trial amplitudes, by an interaction in their single-trial latencies, or by an interaction in both amplitude and latency. We then analyzed the accuracy with which the algorithm estimated the component waveshapes and the single-trial parameters as a function of the linearity of each of these relationships. Extensions of these analyses to real data are discussed as well as ongoing work to incorporate more detailed prior information.

Shah, Ankoor S.↗

Analysis of nystagmus response to a pseudorandom velocity input

Space motion sickness was not reported during the first Apollo missions; however, since Apollo 8 through the current Shuttle and Skylab missions, approximately 50% of the crewmembers have experienced instances of space motion sickness. Space motion sickness, renamed space adaptation syndrome, occurs primarily during the initial period of a mission until habilation takes place. One of NASA's efforts to resolve the space adaptation syndrome is to model the individual's vestibular response for basis knowledge and as a possible predictor of an individual's susceptibility to the disorder. This report describes a method to analyse the vestibular system when subjected to a pseudorandom angular velocity input. A sum of sinusoids (pseudorandom) input lends itself to analysis by linear frequency methods. Resultant horizontal ocular movements were digitized, filtered and transformed into the frequency domain. Programs were developed and evaluated to obtain the (1) auto spectra of input stimulus and resultant ocular resonse, (2) cross spectra, (3) the estimated vestibular-ocular system transfer function gain and phase, and (4) coherence function between stimulus and response functions.

Lessard, C. S.↗

Properties of cerebellar fastigial neurons during translation, rotation, and eye movements

The most medial of the deep cerebellar nuclei, the fastigial nucleus (FN), receives sensory vestibular information and direct inhibition from the cerebellar vermis. We investigated the signal processing in the primate FN by recording single-unit activities during translational motion, rotational motion, and eye movements. Firing rate modulation during horizontal plane translation in the absence of eye movements was observed in all non-eye-movement-sensitive cells and 26% of the pursuit eye-movement-sensitive neurons in the caudal FN. Many non-eye-movement-sensitive cells recorded in the rostral FN of three fascicularis monkeys exhibited convergence of signals from both the otolith organs and the semicircular canals. At low frequencies of translation, the majority of these rostral FN cells changed their firing rates in phase with head velocity rather than linear acceleration. As frequency increased, FN vestibular neurons exhibited a wide range of response dynamics with most cells being characterized by increasing phase leads as a function of frequency. Unlike cells in the vestibular nuclei, none of the rostral FN cells responded to rotational motion alone, without simultaneously exhibiting sensitivity to translational motion. Modulation during earth-horizontal axis rotation was observed in more than half (77%) of the neurons, although with smaller gains than during translation. In contrast, only 47% of the cells changed their firing rates during earth-vertical axis rotations in the absence of a dynamic linear acceleration stimulus. These response properties suggest that the rostral FN represents a main processing center of otolith-driven information for inertial motion detection and spatial orientation.

Non-NASA Center↗

A Review and Comparison of Mouse and Rat Responses to Micro Gravity, Hyper Gravity and Simulated Models of Partial Gravity; Species Differences, Gaps in the Available Data, and Consideration of the Advantages and Caveats of Each Model for Spaceflight

Laboratory strains of mice and rat are widely used to study mammalian responses to stimulus, and both have been studied under a variety of gravity conditions, including space flight. We compared results obtained from exposure to spaceflight and microgravity, hyper gravity via centrifugation, earth gravity, and models of simulated partial gravity (hind-limb unloading and partial weight bearing treatments). We examined the reported changes in survival, body mass, circadian rhythm (body temperature and activity levels), behavior, bone, muscle, immune, cardio-vasculature, vestibular, reproduction and neonate survival, microbiome, and the visual system. Not all categories have published data for both species, some have limited data, and there are variations in experiment design that allow for only relative comparisons to be considered. The data reveal species differences in both the level of gravity required to obtain a response, degree of response, and in temporal expression of responses. Examination of the data across the gravity levels allows consideration of the hypothesis that gravitational responses follow a continuum, and organ specific differences are noted. In summary, we present advantages and caveats of each model system as pertains to gravitational biology research and identify gaps in our knowledge of how these mammals respond to gravity.

mouse rat gravity↗

Characterizing Oscillatory Bursts in Single-Trial EEG Data

Oscillatory bursts in numerous bands ranging from low (theta) to high frequencies (e.g., gamma) undoubtedly play an important role in cortical dynamics. Largely because of the inadequacy of existing analytic techniques. however, oscillatory bursts and their role in cortical processing remains poorly understood. To study oscillatory bursts effectively one must be able to isolate them and characterize them in the single trial. We describe a series of straightforward analysis techniques that produce useful indices of burst characteristics. First, stimulus-evoked responses are estimated using Differentially Variable Component Analysis (dVCA), and are subtracted from the single-trial. The single-trial characteristics of the evoked responses are stored to identify possible correlations with burst activity. Time-frequency (T-F), or wavelet, analyses are then applied to the single trial residuals. While T-F plots have been used in recent studies to identify and isolate bursts, we go further by fitting each burst in the T-F plot with a two-dimensional Gaussian. This provides a set of burst characteristics, such as, center time. burst duration, center frequency. frequency dispersion. and amplitude, all of which contribute to the accurate characterization of the individual burst. The burst phase can also be estimated. Burst characteristics can be quantified with several standard techniques (e.g.. histogramming and clustering), as well as Bayesian techniques (e.g., blocking) to allow a more parametric description analysis of the characteristics of oscillatory bursts, and the relationships of specific parameters to cortical excitability and stimulus integration.

Knuth, K. H.↗

High Capacity Step-Shaped Hydrogen Adsorption in Robust, Pore-Gating Zeolitic Imidazolate Frameworks (Final Technical Report)

The use of porous adsorbents for the densification of H 2 under relatively mild pressures and temperatures has been long pursued through various avenues of synthetic organic frameworks, namely metal–organic frameworks. However, the overwhelming majority of these materials are macroscopically rigid, exhibiting adsorption–desorption profiles that require appreciable energetic input for their full payload capacity to be stored and subsequently delivered. This reduced “deliverable” capacity is a core inefficiency in the use of porous adsorbents for H 2 densification. Our core mission is to determine a material-based strategy that fundamentally alters the adsorption¬–desorption profile in a manner that obviates these deleterious energetic requirements. Towards this, we have focused on metal–organic frameworks that exhibit “cooperative flexibility”, wherein the material undergoes reversible macroscopic phase changes in response to changes to external temperature and/or adsorbate pressure (i.e., concentration). Where these reversible switches occur between states of disparate enough accessible porosity, cooperatively flexible frameworks can exhibit “step-shaped” adsorption–desorption profiles that enable use of the delivery gaseous payload without the aforementioned additional energy requirements. However, before our work, such the observation of this phenomenon with very weakly adsorbing H 2 had not been observed with the necessary profile and P/T conditions desired for H 2 storage and delivery. During this project we have leveraged a deep understanding of the phase change in family of cooperatively flexible metal–organic frameworks to systematically alter their adsorption–desorption profiles to achieve step-shaped adsorption and desorption of H 2 in a precise P/T regime that enables a high deliverable capacity. Specifically, the thermodynamics of the adsorption/desorption induced phase changes in the baseline framework CdIF-13 (sod–Cd(benzimidazolate) 2 ) were tuned using the mixed-linker, or multivariate, approach to framework derivatization. Follow this, we have pursued a similar approach to tuning the adsorption–desorption profile of a second framework family, MIL-53(Al), which contains only Al(III) and theoretically exhibits a much higher deliverable capacity. In total, our work demonstrates that by first understanding the structural consequences of phase changes in these materials, their behavior can be systematically altered through ligand substitutions, tuning the pressure and temperature conditions at which H 2 is adsorbed and desorbed. Thus, enabling high deliverable capacities of H 2 with minimized energetic requirements.

08 HYDROGEN↗

The effect of a redundant color code on an overlearned identification task

The possibility of finding redundancy gains with overlearned tasks was examined using a paradigm varying familiarity with the stimulus set. Redundant coding in a multidimensional stimulus was demonstrated to result in increased identification accuracy and decreased latency of identification when compared to stimuli varying on only one dimension. The advantages attributable to redundant coding are referred to as redundancy gain and were found for a variety of stimulus dimension combinations, including the use of hue or color as one of the dimensions. Factors that have affected redundancy gain include the discriminability of the levels of one stimulus dimension and the level of stimulus-to-response association. The results demonstrated that response time is in part a function of familiarity, but no effect of redundant color coding was demonstrated. Implications of research on coding in identification tasks for display design are discussed.

Obrien, Kevin↗

Misalignment Effect Function Measurement for Oblique Rotation Axes: Counterintuitive Predictions and Theoretical Extensions

The Misalignment Effect Function (MEF) describes the decrement in manual performance associated with a rotation between operators' visual display frame of reference and that of their manual control. It now has been empirically determined for rotation axes oblique to canonical body axes and is compared with the MEF previously measured for rotations about canonical axes. A targeting rule, called the Secant Rule, based on these earlier measurements is derived from a hypothetical process and shown to describe some of the data from three previous experiments. It explains the motion trajectories determined for rotations less than 65deg in purely kinematic terms without the need to appeal to a mental rotation process. Further analysis of this rule in three dimensions applied to oblique rotation axes leads to a somewhat surprising expectation that the difficulty posed by rotational misalignment should get harder as the required movement is shorter. This prediction is confirmed. Geometry underlying this rule also suggests analytic extensions for predicting more generally the difficulty of making movements in arbitrary directions subject to arbitrary misalignments.

rotated control frames↗