Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Alkaline static feed electrolyzer based oxygen generation system

In preparation for the future deployment of the Space Station, an R and D program was established to demonstrate integrated operation of an alkaline Water Electrolysis System and a fuel cell as an energy storage device. The program's scope was revised when the Space Station Control Board changed the energy storage baseline for the Space Station. The new scope was aimed at the development of an alkaline Static Feed Electrolyzer for use in an Environmental Control/Life Support System as an oxygen generation system. As a result, the program was divided into two phases. The phase 1 effort was directed at the development of the Static Feed Electrolyzer for application in a Regenerative Fuel Cell System. During this phase, the program emphasized incorporation of the Regenerative Fuel Cell System design requirements into the Static Feed Electrolyzer electrochemical module design and the mechanical components design. The mechanical components included a Pressure Control Assembly, a Water Supply Assembly and a Thermal Control Assembly. These designs were completed through manufacturing drawing during Phase 1. The Phase 2 effort was directed at advancing the Alkaline Static Feed Electrolyzer database for an oxygen generation system. This development was aimed at extending the Static Feed Electrolyzer database in areas which may be encountered from initial fabrication through transportation, storage, launch and eventual Space Station startup. During this Phase, the Program emphasized three major areas: materials evaluation, electrochemical module scaling and performance repeatability and Static Feed Electrolyzer operational definition and characterization.

Noble, L. D.↗

Results of the recent precipitation static flight test program on the Navy P-3B antisubmarine aircraft

Severe precipitation static problems affecting the communication equipment onboard the P-3B aircraft were recently studied. The study was conducted after precipitation static created potential safety-of-flight problems on Naval Reserve aircraft. A specially designed flight test program was conducted in order to measure, record, analyze, and characterize potential precipitation static problem areas. The test program successfully characterized the precipitation static interference problems while the P-3B was flown in moderate to extreme precipitation conditions. Data up to 400 MHz were collected on the effects of engine charging, precipitation static, and extreme cross fields. These data were collected using a computer controlled acquisition system consisting of a signal generator, RF spectrum and audio analyzers, data recorders, and instrumented static dischargers. The test program is outlined and the computer controlled data acquisition system is described in detail which was used during flight and ground testing. The correlation of test results is also discussed which were recorded during the flight test program and those measured during ground testing.

Whitaker, Mike↗

Closed-form Static Analysis with Inertia Relief and Displacement-Dependent Loads Using a MSC/NASTRAN DMAP Alter

Solving for the displacements of free-free coupled systems acted upon by static loads is commonly performed throughout the aerospace industry. Many times, these problems are solved using static analysis with inertia relief. This solution technique allows for a free-free static analysis by balancing the applied loads with inertia loads generated by the applied loads. For some engineering applications, the displacements of the free-free coupled system induce additional static loads. Hence, the applied loads are equal to the original loads plus displacement-dependent loads. Solving for the final displacements of such systems is commonly performed using iterative solution techniques. Unfortunately, these techniques can be time-consuming and labor-intensive. Since the coupled system equations for free-free systems with displacement-dependent loads can be written in closed-form, it is advantageous to solve for the displacements in this manner. Implementing closed-form equations in static analysis with inertia relief is analogous to implementing transfer functions in dynamic analysis. Using a MSC/NASTRAN DMAP Alter, displacement-dependent loads have been included in static analysis with inertia relief. Such an Alter has been used successfully to solve efficiently a common aerospace problem typically solved using an iterative technique.

Barnett, Alan R.↗

Wind-Tunnel Tests of Seven Static-Pressure Probes at Transonic Speeds

Wind-tunnel tests have been conducted to determine the errors of 3 seven static-pressure probes mounted very close to the nose of a body of revolution simulating a missile forebody. The tests were conducted at Mach numbers from 0.80 to 1.08 and at angles of attack from -1.7 deg to 8.4 deg. The test Reynolds number per foot varied from 3.35 x 10(exp 6) to 4.05 x 10(exp 6). For three 4-vane, gimbaled probes, the static-pressure errors remained constant throughout the test angle-of-attack range for all Mach numbers except 1.02. For two single-vane, self-rotating probes having two orifices at +/-37.5 deg. from the plane of symmetry on the lower surface of the probe body, the static-pressure error varied as much as 1.5 percent of free-stream static pressure through the test angle-of- attack range for all Mach numbers. For two fixed, cone-cylinder probes of short length and large diameter, the static-pressure error varied over the test angle-of-attack range at constant Mach numbers as much as 8 to 10 percent of free-stream static pressure.

Capone, Francis J.↗

Static and Wind Tunnel Aero-Performance Tests of NASA AST Separate Flow Nozzle Noise Reduction Configurations

This report presents the results of cold flow model tests to determine the static and wind tunnel performance of several NASA AST separate flow nozzle noise reduction configurations. The tests were conducted by Aero Systems Engineering, Inc., for NASA Glenn Research Center. The tests were performed in the Channels 14 and 6 static thrust stands and the Channel 10 transonic wind tunnel at the FluiDyne Aerodynamics Laboratory in Plymouth, Minnesota. Facility checkout tests were made using standard ASME long-radius metering nozzles. These tests demonstrated facility data accuracy at flow conditions similar to the model tests. Channel 14 static tests reported here consisted of 21 ASME nozzle facility checkout tests and 57 static model performance tests (including 22 at no charge). Fan nozzle pressure ratio varied from 1.4 to 2.0, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Channel 10 wind tunnel tests consisted of 15 tests at Mach number 0.28 and 31 tests at Mach 0.8. The sting was checked out statically in Channel 6 before the wind tunnel tests. In the Channel 6 facility, 12 ASME nozzle data points were taken and 7 model data points were taken. In the wind tunnel, fan nozzle pressure ratio varied from 1.73 to 2.8, and fan to core total pressure ratio varied from 1.0 to 1.19. Core to fan total temperature ratio was 1.0. Test results include thrust coefficients, thrust vector angle, core and fan nozzle discharge coefficients, total pressure and temperature charging station profiles, and boat-tail static pressure distributions in the wind tunnel.

Mikkelsen, Kevin L.↗

Characterization of Space Shuttle Reusable Rocket Motor Static Test Stand Thrust Measurements

Space Shuttle Reusable Solid Rocket Motors (RSRM) are static tested at two ATK Thiokol Propulsion facilities in Utah, T-24 and T-97. The newer T-97 static test facility was recently upgraded to allow thrust measurement capability. All previous static test motor thrust measurements have been taken at T-24; data from these tests were used to characterize thrust parameters and requirement limits for flight motors. Validation of the new T-97 thrust measurement system is required prior to use for official RSRM performance assessments. Since thrust cannot be measured on RSRM flight motors, flight motor measured chamber pressure and a nominal thrust-to-pressure relationship (based on static test motor thrust and pressure measurements) are used to reconstruct flight motor performance. Historical static test and flight motor performance data are used in conjunction with production subscale test data to predict RSRM performance. The predicted motor performance is provided to support Space Shuttle trajectory and system loads analyses. Therefore, an accurate nominal thrust-to-pressure (F/P) relationship is critical for accurate RSRM flight motor performance and Space Shuttle analyses. Flight Support Motors (FSM) 7, 8, and 9 provided thrust data for the validation of the T-97 thrust measurement system. The T-97 thrust data were analyzed and compared to thrust previously measured at T-24 to verify measured thrust data and identify any test-stand bias. The T-97 FIP data were consistent and within the T-24 static test statistical family expectation. The FSMs 7-9 thrust data met all NASA contract requirements, and the test stand is now verified for future thrust measurements.

Mart L. Cook↗

Residual Static Strength of ALuminum-Alloy Beams Containing Fatigue Cracks in the Tension Covers

Static tests were performed on 31 box beams containing fatigue cracks in order to determine their residual static strengths. The beams were constructed of 7075 and 2024 aluminum alloy according to several designs and employed stringers that were either bonded, riveted, or an integral part of the skin. skin (both aaterials) had the highest residual static strengths, whereas 7075 beams with integrally stiffened covers had the lowest residual static strengths. Except for the integrally stiffened beams, the skin material did not contribute to the residual static strength of the beams because the crack propagated across the skin before maximum load was reached. For the integrally stiffened beams, crack propagation and failure were synonymous. The test results are compared with predictions of the residual static strength. Fair agreement between predicted strength and actual strength was obtained for all beams tested.

Leybold, Herbert A.↗

MSC/NASTRAN DMAP Alter Used for Closed-Form Static Analysis With Inertia Relief and Displacement-Dependent Loads

Solving for the displacements of free-free coupled systems acted upon by static loads is a common task in the aerospace industry. Often, these problems are solved by static analysis with inertia relief. This technique allows for a free-free static analysis by balancing the applied loads with the inertia loads generated by the applied loads. For some engineering applications, the displacements of the free-free coupled system induce additional static loads. Hence, the applied loads are equal to the original loads plus the displacement-dependent loads. A launch vehicle being acted upon by an aerodynamic loading can have such applied loads. The final displacements of such systems are commonly determined with iterative solution techniques. Unfortunately, these techniques can be time consuming and labor intensive. Because the coupled system equations for free-free systems with displacement-dependent loads can be written in closed form, it is advantageous to solve for the displacements in this manner. Implementing closed-form equations in static analysis with inertia relief is analogous to implementing transfer functions in dynamic analysis. An MSC/NASTRAN (MacNeal-Schwendler Corporation/NASA Structural Analysis) DMAP (Direct Matrix Abstraction Program) Alter was used to include displacement-dependent loads in static analysis with inertia relief. It efficiently solved a common aerospace problem that typically has been solved with an iterative technique.

Source record↗

Effect of Solution Heating Rate on Quasi-static and Dynamic Mechanical Properties of Al-Mg-Si-Cu Alloy

The effect of solution heating rate on quasi-static and dynamic mechanical properties of Al-Mg-Si-Cu alloy in bake hardening state was investigated through mechanical properties, microstructure and fracture morphology characterization in the present study. The results show that solution heating rate has a strong influence on microstructure, quasi-static and dynamic mechanical properties. As solution heating rate rises, the grain microstructure transforms from the elongated grains to equiaxed grains and the fraction of low-angle grain boundaries (LAGBs) also decreases. Moreover, the equivalent average grain size first decreases, and then increases. The relationship between solution heating rate and mechanical property is monotonic, not depending on strain rate. As solution heating rate rises, the yield strength, ultimate tensile strength and elongation decrease. In contrast to quasi-static loading, dynamic loading always tends to improve strengths and elongation. In addition, compared with the quasi-static tensile specimens, the dynamic tensile specimens possess a larger number of dislocations. Regardless of strain rate and solution heating rate, all the tensile specimens exhibit the ductile fracture mode. As solution rate rises, the dimples decrease and become shallow gradually. The dimples in dynamic fracture zone are larger and deeper than those in the quasi-static fracture zone.

36 MATERIALS SCIENCE↗

Calculation of reinforced-concrete frame strength under a simultaneous static cross section load and a column lateral impact

When designing buildings with reinforced concrete that are planned to resist dynamic loads it is necessary to calculate this structural behavior under operational static and emergency impact and blast loads. Calculations of the structures under shock-wave loads can be performed by solving dynamic equations that do not consider static loads. Due to this fact the calculation of reinforced concrete frame under a simultaneous static and dynamic load in full 3d settings becomes a very non trivial and resource consuming problem. This problem can be split into two tasks. The first one is a shock-wave problem that can be solved using software package RANET-3, which allows solving the problem using finite elements method adapted for dynamic task. This method calculates strain-stress state of the material and its dynamic destruction, which is considered as growth and consolidation of micro defects under loading. On the second step the results of the first step are taken as input parameters for quasi static calculation of simultaneous static and dynamic load using finite elements method in AMP Civil Engineering-11.

36 MATERIALS SCIENCE↗

Towards Enhancing Coding Productivity for GPU Programming Using Static Graphs

The main contribution of this work is to increase the coding productivity of GPU programming by using the concept of Static Graphs. GPU capabilities have been increasing significantly in terms of performance and memory capacity. However, there are still some problems in terms of scalability and limitations to the amount of work that a GPU can perform at a time. To minimize the overhead associated with the launch of GPU kernels, as well as to maximize the use of GPU capacity, we have combined the new CUDA Graph API with the CUDA programming model (including CUDA math libraries) and the OpenACC programming model. We use as test cases two different, well-known and widely used problems in HPC and AI: the Conjugate Gradient method and the Particle Swarm Optimization. In the first test case (Conjugate Gradient) we focus on the integration of Static Graphs with CUDA. In this case, we are able to significantly outperform the NVIDIA reference code, reaching an acceleration of up to 11x thanks to a better implementation, which can benefit from the new CUDA Graph capabilities. In the second test case (Particle Swarm Optimization), we complement the OpenACC functionality with the use of CUDA Graph, achieving again accelerations of up to one order of magnitude, with average speedups ranging from 2x to 4x, and performance very close to a reference and optimized CUDA code. Our main target is to achieve a higher coding productivity model for GPU programming by using Static Graphs, which provides, in a very transparent way, a better exploitation of the GPU capacity. The combination of using Static Graphs with two of the current most important GPU programming models (CUDA and OpenACC) is able to reduce considerably the execution time w.r.t. the use of CUDA and OpenACC only, achieving accelerations of up to more than one order of magnitude. Finally, we propose an interface to incorporate the concept of Static Graphs into the OpenACC Specifications.

58 GEOSCIENCES↗

Overview of the 2nd Gen 3.7m HIAD Static Load Test

To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for human class payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). In October of 2014, a 3.7m HIAD inflatable structure with an integrated flexible thermal protection sys-tem (F-TPS) was subjected to a static load test series to verify the designs structural performance. The 3.7m HIAD structure was constructed in a 70 deg sphere-cone stacked-toroid configuration using eight inflatable tori, which were joined together using adhesives and high strength textile webbing to help distribute the loads throughout the inflatable structure. The inflatable structure was fabricated using 2nd generation structural materials that permit an increase in use temperature to 400 C+ as compared to the 250 C limitation of the 1st generation materials. In addition to the temperature benefit, these materials also offer a 40 reduction in structure mass. The 3.7m F-TPS was fabricated using high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. The F-TPS was constructed of 2nd generation TPS materials increasing its heating capability from 35W sq cm to over 100W sq cm. This test article is the first stacked-torus HIAD to be fabricated and tested with a 70 deg sphere-cone. All previous stacked-torus HIADs have employed a 60o sphere-cone. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for dis-placement of the inflatable structure as loads were applied. The tub rim was attached to the floor to provide an airtight seal. The center body of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to characterize deformed shape, shoulder deflection, strap loads, and cord loads as a function of structural configuration and applied static load. In this overview, the 3.7m HIAD static load test series will be discussed in detail, including the 3.7m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally results and conclusions from the test series.

HIAD↗

CST: A Tool for Optimizing the Efficiency and Effectiveness of Static-Code Analysis Tools

Static Code Analysis (SCA) is a vital component of NASA IV&V’s mission assurance for safety-critical software as it reduces the likelihood of software-induced hazards impacting mission success. Static Code Analysis achieves this by identifying hazards that may not have been otherwise detectable by typical code reviews or other testing. Using SCA tools, however, can be intimidating due to steep learning curves, especially considering tool performance and defect coverage varies greatly. Because of this variation amongst SCA tools, understanding which tools support certain defects and which do not, as well as understanding how to run an analysis based on steps that are unique to each tool, can be difficult to both new and experienced analysts alike. To mitigate this, the SCAWG or the IV&V Static Code Analysis Working Group, created the SCA Checker Taxonomy and Starting Point Profiles. The Checker Selection Tool (CST) incorporates these two SCAWG products into an interactive tool which allows the user to: select organized categories of defects they would like the SCA tools to discover, select default checkers depending on their mission type (e.g. flight), and configure multiple SCA tools at once. C/C++, Java, and Python defect checkers from four common SCA tools were utilized in this iteration of the CST. This iteration also includes the addition of training, SCA tool specific help, and taxonomy guide links, into its design to help users new to Static Code Analysis learn how to perform SCA more efficiently. The CST has been subject to beta testing by experienced static code analysts from the SCAWG to ensure a usable and accurate final product. The implications of the CST in the mission assurance of NASA safety-critical software are profound, as the CST can help identify and reduce false positives and false negatives, fundamentally improving overall SCA efficiency and accuracy.

static code analysis↗

Combined Static and Dynamic Computed Tomography Angiography of Peripheral Artery Occlusive Disease: Comparison with Magnetic Resonance Angiography

PurposeTo compare in patients with known peripheral artery occlusive disease (PAOD), image quality of a combined CTA to a combined MRA protocol, including both static and dynamic acquisitions.Materials and MethodsTwenty-two patients with PAOD were examined with a combined CTA and MRA protocol consisting of static acquisitions (s-CTA, s-MRA) of the entire runoff and dynamic acquisitions (d-CTA, d-MRA) of the calves. Two radiologists compared image quality of the s-MRA versus s-CTA as well as d-MRA versus d-CTA. Image quality was assessed on a segmental basis using a 4-point Likert scale.ResultsFor s-CTA, 76% of segments were rated as excellent or good. For s-MRA, 50% of segments were rated as excellent or good (p < 0.0001). For d-CTA, median image quality score for all segments was rated as excellent for both readers. For d-MRA, median image quality for the different segments ranged from moderate to good. For both d-CTA and d-MRA, the median image quality scores were significantly higher for all segments of the lower limb compared with the static examinations of the lower limb segments (all p values < 0.0001). In patients with PAOD category 4–6, 80% of segments were rated as excellent or good for d-CTA, while 45% of segments were rated as poor or non-diagnostic for d-MRA.ConclusionIn patients with known PAOD, a combined static and dynamic CTA examination improves image quality relative to static and dynamic MRA and should be considered as an alternative to MRA, particularly in patients with advanced stage PAOD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Static pressure drives proliferation of vascular smooth muscle cells via caveolin-1/ERK1/2 pathway

Intimal hyperplasia plays an important role in various types of vascular remodeling. Mechanical forces derived from blood flow are associated with the proliferation of vascular smooth muscle cells (VSMC). This contributes to many vascular disorders such as hypertension, atherosclerosis and restenosis after percutaneous transluminal angioplasty (PTA). In this study, we show that static pressure induces the proliferation of VSMC and activates its related signal pathway. VSMC from a rat aorta were treated with different pressures (0, 60, 90, 120, 150 and 180 mm Hg) in a custom-made pressure incubator for 24 h. The most active proliferation of VSMC was detected at a pressure of 120 mm Hg. VSMC was also incubated under a static pressure of 120 mm Hg for different time intervals (0, 2, 4, 8, 12 and 24 h). We found that static pressure significantly stimulates VSMC proliferation. Extracellular signal-regulated kinases 1/2 (ERK1/2) activation showed a peak at the pressure of 120 mm Hg at 4-h time point. Moreover, caveolin-1 expression was significantly inhibited by rising static pressure. Downregulation of VSMC proliferation could be found after PD98059 (ERK1/2 phosphorylation inhibitor) treatment. Our data also showed that a siRNA-mediated caveolin-1 knock down increased ERK1/2 phosphorylation and VSMC proliferation. These results demonstrate that static pressure promotes VSMC proliferation via the Caveolin-1/ERK1/2 pathway.

60 APPLIED LIFE SCIENCES↗

Effect of static local distortions vs. dynamic motions on the stability and band gaps of cubic oxide and halide perovskites

Ternary ABX 3 perovskites made of corner-sharing BX 6 octahedra have long featured prominently in solid-state chemistry and condensed matter physics. Still, the joint understanding of their two main subgroups—halides and oxides—has not been fully developed. Indeed, unlike the case in simpler compounds having a single, robust repeated motif (“monomorphous”), certain cubic perovskites can manifest a non-thermal (= intrinsic) distribution of local motifs (“polymorphous networks”). Such static deformations can include positional degrees of freedom (e.g., atomic displacements and octahedral tilting) or magnetic moment degrees of freedom in paramagnets. Unlike thermal motion, such static distortions do not time-average to zero, being an expression of the intrinsic symmetry breaking preference of the chemical bonding. Here, the present study compares electronic structure features of oxide and halide perovskites starting from the static polymorphous distribution of motifs described by Density Functional Theory (DFT) minimization of the internal energy, continuing to finite temperature thermal disorder modeled via finite temperature DFT molecular dynamics. We find that (i) different oxide vs. halide ABX 3 compounds adopt different energy-lowering symmetry-breaking modes. The calculated pair distribution function (PDF) of SrTiO 3 from the first-principles agrees with recently measured PDF. (ii) In both oxides and halides, such static distortions lead to band gap blueshifts with respect to undistorted cubic Pm-3m structure. (iii) For oxide perovskites, high-temperature molecular dynamics simulations initiated from the statically distorted polymorphous structures reveal that the thermally-induced distortions can lead to a band gap redshift. (iv) In contrast, for cubic halide perovskite CsPbI 3 , both the intrinsic distortions and the thermal distortions contribute in tandem to band gap blueshift, the former, intrinsic effect being dominant. (v) In the oxide SrTiO 3 and CaTiO 3 (but not in halide) perovskites, octahedral tilting leads to the emergence of a distinct Γ–Γ direct band gap component as a secondary valley minimum to the well-known indirect R–Γ gap. Understanding such intrinsic vs. thermal effects on oxide vs. halide perovskites holds the potential for designing target electronic properties.

36 MATERIALS SCIENCE↗

A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.

61 RADIATION PROTECTION AND DOSIMETRY↗

Under conditions of large geometric miss, tumor control probability can be higher for static gantry intensity-modulated radiation therapy compared to volume-modulated arc therapy for prostate cancer

The purpose of this work was to compare static gantry intensity-modulated radiation therapy (IMRT) with volume-modulated arc therapy (VMAT) in terms of tumor control probability (TCP) under scenarios involving large geometric misses, i.e., those beyond what are accounted for when margin expansion is determined. Using a planning approach typical for these treatments, a linear-quadratic–based model for TCP was used to compare mean TCP values for a population of patients who experiences a geometric miss (i.e., systematic and random shifts of the clinical target volume within the planning target dose distribution). A Monte Carlo approach was used to account for the different biological sensitivities of a population of patients. Interestingly, for errors consisting of coplanar systematic target volume offsets and three-dimensional random offsets, static gantry IMRT appears to offer an advantage over VMAT in that larger shift errors are tolerated for the same mean TCP. For example, under the conditions simulated, erroneous systematic shifts of 15 mm directly between or directly into static gantry IMRT fields result in mean TCP values between 96% and 98%, whereas the same errors on VMAT plans result in mean TCP values between 45% and 74%. Random geometric shifts of the target volume were characterized using normal distributions in each Cartesian dimension. When the standard deviations were doubled from those values assumed in the derivation of the treatment margins, our model showed a 7% drop in mean TCP for the static gantry IMRT plans but a 20% drop in TCP for the VMAT plans. Although adding a margin for error to a clinical target volume is perhaps the best approach to account for expected geometric misses, this work suggests that static gantry IMRT may offer a treatment that is more tolerant to geometric miss errors than VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗