Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectral mixture analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Molecular detection of per- and polyfluoroalkyl substances in water using time-of-flight secondary ion mass spectrometry

Detection of per- and polyfluoroalkyl substances (PFASs) is crucial in environmental mitigation and remediation of these persistent pollutants. We demonstrate that time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a viable technique to analyze and identify these substances at parts per trillion (ppt) level in real field samples without complicated sample preparation due to its superior surface sensitivity. Several representative PFAS compounds, such as perfluorooctanesulfonic acid (PFOS), perfluorobutanoic acid (PFBA), perfluoropentanoic acid (PFPeA), perfluoheptanoic acid (PFHpA), and perfluorononanoic acid (PFNA), and real-world groundwater samples collected from monitoring wells installed around at a municipal wastewater treatment plant located in Southern California were analyzed in this work. ToF-SIMS spectral comparison depicts sensitive identification of pseudo-molecular ions, characteristic of reference PFASs. Additionally, principal component analysis (PCA) shows clear discrimination among real samples and reference compounds. Our results show that characteristic molecular ion and fragments peaks can be used to identify PFASs. Furthermore, SIMS two-dimensional (2D) images directly exhibit the distribution of perfluorocarboxylic acid (PFCA) and PFOS in simulated mixtures and real wastewater samples. Such findings indicate that ToF-SIMS is useable to determine PFAS compounds in complex environmental water samples. In conclusion, ToF-SIMS provides simple sample preparation and high sensitivity in mass spectral imaging, offering an alternative solution for environmental forensic analysis of PFASs in wastewater in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of the temperature of gas mixtures by using laser Raman scattering

A theoretical model for the Raman rotational spectrum of air was formulated, yielding the spectral temperature dependence; and an error analysis of temperature measurement accuracies was performed. The theoretical spectra and the predicted temperature measurement error of + or - 20 K (7 percent) compared well with experimental data. These experimental data consisted of Raman spectra of air obtained for temperatures ranging from 243 to 313 K at a pressure of 1 atmosphere. The use of selected lines resulted in an experimental accuracy of + or - 13 K (-5 percent).

Coney, T. A.↗

PCP METHODOLOGY FOR DETERMINING DOSE RATES FOR SMALL GRAM QUANTITIES IN SHIPPING PACKAGINGS

The Small Gram Quantity (SGQ) concept is based on the understanding that small amounts of hazardous materials, in this case radioactive materials, are significantly less hazardous than large amounts of the same materials. This study describes a methodology designed to estimate an SGQ for several neutron and gamma emitting isotopes that can be shipped in a package compliant with 10 CFR Part 71 external radiation level limits regulations. These regulations require packaging for the shipment of radioactive materials perform, under both normal and accident conditions, the essential functions of material containment, subcriticality, and maintain external radiation levels within regulatory limits. 10 CFR 71.33(b)(1)(2)&(3) state radioactive and fissile materials must be identified and their maximum quantity, chemical and physical forms be included in an application. Furthermore, the U.S. Federal Regulations require application contain an evaluation demonstrating the package (i.e., the packaging and its contents) satisfies the external radiation standards for all packages (10 CFR 71.31(2), 71.35(a), & 71.47). By placing the contents in a He leak-tight containment vessel, and limiting the mass to ensure subcriticality, the first two essential functions are readily met. Some isotopes emit sufficiently strong photon radiation that small amounts of material can yield a large external dose rate. Quantifying of the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. The Packaging Certification Program (PCP) Methodology for Determining Dose Rate for Small Gram Quantities in Shipping Packagings described in this report provides bounding mass limits for a set of proposed SGQ isotopes. Methodology calculations were performed to estimate external radiation levels for the 9977 shipping package using the MCNP radiation transport code to develop a set of response multipliers (Green's functions) for 'dose per particle' for each neutron and photon spectral group. The source spectrum for each isotope generated using the ORIGEN-S and RASTA computer codes was folded with the response multipliers to generate the dose rate per gram of each isotope in the 9977 shipping package and its associated shielded containers. The maximum amount of a single isotope that could be shipped within the regulatory limits contained in 10 CFR 71.47 for dose rate at the surface of the package is determined. If a package contains a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. Furthermore, the results of this analysis can be easily extended to additional radioisotopes by simply evaluating the neutron and/or photon spectra of those isotopes and folding the spectral data with the Green's functions provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Storage and retrieval of mass spectral information

Computer handling of mass spectra serves two main purposes: the interpretation of the occasional, problematic mass spectrum, and the identification of the large number of spectra generated in the gas-chromatographic-mass spectrometric (GC-MS) analysis of complex natural and synthetic mixtures. Methods available fall into the three categories of library search, artificial intelligence, and learning machine. Optional procedures for coding, abbreviating and filtering a library of spectra minimize time and storage requirements. Newer techniques make increasing use of probability and information theory in accessing files of mass spectral information.

Hohn, M. E.↗

Geologic mapping using Landsat MSS and TM images - Removing vegetation by modeling spectral mixtures

Semi-arid regions of the island of Hawaii and of the Tucson Mountains, AZ, having less than 50 percent green vegetation cover were mapped into rock/soil types by first identifying spectral mixtures of vegetation and rock/soil, and then removing the vegetation information. Landsat MSS images were used for Hawaii, and a Landsat TM image was used for the Tucson Mountains. Following analysis of the images field transects were done in test areas to determine percent vegetation cover and vegetation community characteristics, and to observe rock and soil types. For both Hawaii and the Tucson Mountains 20 percent or more of green vegetation caused potential misidentification of the rock/soil units unless spectral mixing was taken into account.

Adams, J. B.↗

Ejecta patterns of Meteor Crater, Arizona derived from the linear un-mixing of TIMS data and laboratory thermal emission spectra

Accurate interpretation of thermal infrared data depends upon the understanding and removal of complicating effects. These effects may include physical mixing of various mineralogies and particle sizes, atmospheric absorption and emission, surficial coatings, geometry effects, and differential surface temperatures. The focus is the examination of the linear spectral mixing of individual mineral or endmember spectra. Linear addition of spectra, for particles larger than the wavelength, allows for a straight-forward method of deconvolving the observed spectra, predicting a volume percent of each endmember. The 'forward analysis' of linear mixing (comparing the spectra of physical mixtures to numerical mixtures) has received much attention. The reverse approach of un-mixing thermal emission spectra was examined with remotely sensed data, but no laboratory verification exists. Understanding of the effects of spectral mixing on high resolution laboratory spectra allows for the extrapolation to lower resolution, and often more complicated, remotely gathered data. Thermal Infrared Multispectral Scanner (TIMS) data for Meteor Crater, Arizona were acquired in Sep. 1987. The spectral un-mixing of these data gives a unique test of the laboratory results. Meteor Crater (1.2 km in diameter and 180 m deep) is located in north-central Arizona, west of Canyon Diablo. The arid environment, paucity of vegetation, and low relief make the region ideal for remote data acquisition. Within the horizontal sedimentary sequence that forms the upper Colorado Plateau, the oldest unit sampled by the impact crater was the Permian Coconino Sandstone. A thin bed of the Toroweap Formation, also of Permian age, conformably overlays the Coconino. Above the Toroweap lies the Permian Kiabab Limestone which, in turn, is covered by a thin veneer of the Moenkopi Formation. The Moenkopi is Triassic in age and has two distinct sub-units in the vicinity of the crater. The lower Wupatki member is a fine-grained sandstone, while the upper Moqui member is a fissile siltstone. Ejecta from these units are preserved as inverted stratigraphy up to 2 crater radii from the rim. The mineralogical contrast between the units, relative lack of post-emplacement erosion and ejecta mixing provide a unique site to apply the un-mixing model. Selection of the aforementioned units as endmembers reveals distinct patterns in the ejecta of the crater.

Ramsey, Michael S.↗

Machine Learning-Based Classification of Lignocellulosic Biomass from Pyrolysis-Molecular Beam Mass Spectrometry Data

High-throughput analysis of biomass is necessary to ensure consistent and uniform feedstocks for agricultural and bioenergy applications and is needed to inform genomics and systems biology models. Pyrolysis followed by mass spectrometry such as molecular beam mass spectrometry (py-MBMS) analyses are becoming increasingly popular for the rapid analysis of biomass cell wall composition and typically require the use of different data analysis tools depending on the need and application. Here, the authors report the py-MBMS analysis of several types of lignocellulosic biomass to gain an understanding of spectral patterns and variation with associated biomass composition and use machine learning approaches to classify, differentiate, and predict biomass types on the basis of py-MBMS spectra. Py-MBMS spectra were also corrected for instrumental variance using generalized linear modeling (GLM) based on the use of select ions relative abundances as spike-in controls. Machine learning classification algorithms e.g., random forest, k-nearest neighbor, decision tree, Gaussian Naïve Bayes, gradient boosting, and multilayer perceptron classifiers were used. The k-nearest neighbors (k-NN) classifier generally performed the best for classifications using raw spectral data, and the decision tree classifier performed the worst. After normalization of spectra to account for instrumental variance, all the classifiers had comparable and generally acceptable performance for predicting the biomass types, although the k-NN and decision tree classifiers were not as accurate for prediction of specific sample types. Gaussian Naïve Bayes (GNB) and extreme gradient boosting (XGB) classifiers performed better than the k-NN and the decision tree classifiers for the prediction of biomass mixtures. The data analysis workflow reported here could be applied and extended for comparison of biomass samples of varying types, species, phenotypes, and/or genotypes or subjected to different treatments, environments, etc. to further elucidate the sources of spectral variance, patterns, and to infer compositional information based on spectral analysis, particularly for analysis of data without a priori knowledge of the feedstock composition or identity.

59 BASIC BIOLOGICAL SCIENCES↗

Measured rotational and vibrational temperature differences in arc jet shock layers

Shock-layer-radiation emission spectra from the first negative system of the nitrogen molecular ion N2(+) are analyzed over the wavelength region between 370 and 430 nm. The shock layer is produced by a blunt body placed in the expanded flow from an arc heater employing either pure nitrogen or a nitrogen-oxygen air mixture. A rotational temperature is obtained from analysis of (0,1) band emission from N2(+). Vibrational temperatures are extracted from population distributions obtained through spectral fitting of the N2(+) (B-X) band sequences. Rotational temperatures up to 9500 K near the front of the shocks are determined for different energy and flow conditions. The rotational temperatures are found to be lower than those obtained for vibration confirming previous measurements and contrary to expectation based on theory.

Blackwell, Harvel E.↗

Chemical variability in mineralized veins observed by ChemCam on the lower slopes of Mount Sharp in Gale crater, Mars

ChemCam has observed a wide range of diagenetic features along the Curiosity rover traverse including pervasive Ca-sulfate veins. Observations by multiple instruments on Curiosity indicate that these veins are hydrated, formed during diagenetic fluid event(s). In this study, we delve into the chemical variability in these Ca-sulfate bearing veins and have identified two subsets in the Murray formation with enrichments in Fe and Fe + Mg. These chemical trends do not reflect a sampling mixture with the surrounding host rock but likely indicates the presence of authigenic phases formed during the emplacement of these veins. Based on passive reflectance spectral analysis and correlation with other elements, Fe 3+ oxides and/or sulfates are proposed to account for the Fe-rich observations in the vicinity of the Naukluft Plateau whereas the Fe + Mg trend is also observed in adjacent dark-toned features with elevated Mn and P near the Old Soaker outcrop. In conclusion, the specific localization of these observations in the Gale stratigraphy implies changing pH and redox conditions in the groundwater at the time of formation of these veins, from oxidizing and likely more acidic near the Naukluft Plateau to more reducing conditions in the upper part of the Murray formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-CD-206-01: Expectation-Maximization Algorithm-Based Tissue Mixture Quantification for Perfusion MRI

Purpose: To investigate the feasibility of estimating the tissue mixture perfusions and quantifying cerebral blood flow change in arterial spin labeled (ASL) perfusion MR images. Methods: The proposed perfusion MR image analysis framework consists of 5 steps: (1) Inhomogeneity correction was performed on the T1- and T2-weighted images, which are available for each studied perfusion MR dataset. (2) We used the publicly available FSL toolbox to strip off the non-brain structures from the T1- and T2-weighted MR images. (3) We applied a multi-spectral tissue-mixture segmentation algorithm on both T1- and T2-structural MR images to roughly estimate the fraction of each tissue type - white matter, grey matter and cerebral spinal fluid inside each image voxel. (4) The distributions of the three tissue types or tissue mixture across the structural image array are down-sampled and mapped onto the ASL voxel array via a co-registration operation. (5) The presented 4-dimensional expectation-maximization (4D-EM) algorithm takes the down-sampled three tissue type distributions on perfusion image data to generate the perfusion mean, variance and percentage images for each tissue type of interest. Results: Experimental results on three volunteer datasets demonstrated that the multi-spectral tissue-mixture segmentation algorithm was effective to initialize tissue mixtures from T1- and T2-weighted MR images. Compared with the conventional ASL image processing toolbox, the proposed 4D-EM algorithm not only generated comparable perfusion mean images, but also produced perfusion variance and percentage images, which the ASL toolbox cannot obtain. It is observed that the perfusion contribution percentages may not be the same as the corresponding tissue mixture volume fractions estimated in the structural images. Conclusion: A specific application to brain ASL images showed that the presented perfusion image analysis method is promising for detecting subtle changes in tissue perfusions, which is valuable for the early diagnosis of certain brain diseases, e.g. multiple sclerosis.

60 APPLIED LIFE SCIENCES↗

Higher-Order Mass Defect Analysis for Mass Spectra of Complex Organic Mixtures

Higher-order mass defect analysis is introduced as a unique formula assignment and visualization method for the analysis of complex mass spectra. This approach is an extension of the concepts of Kendrick mass transformation widely used for identification of homologous compounds differing only by a number of base units (e.g., CH2, H2, O, CH2O, etc.) in complex mixtures. We present an iterative renormalization routine for defining higher order homologous series and multidimensional clustering of mass spectral features. This approach greatly simplifies visualization of complex mass spectra and increases the number of chemical formulae that can be confidently assigned for given mass accuracy. The potential for using higher-order mass defects for data reduction and visualization is shown. Higher-order mass defect analysis is described and demonstrated through third-order analysis of a de-isotoped high-resolution mass spectrum of crude oil containing nearly 13,000 peaks.

02 PETROLEUM↗

Mapping Chaparral in the Santa Monica Mountatins Using Multiple Endmember Spectral Mixture Models

From Intro: A study was initiated in the Santa Monica Mountains to investigate the use of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)for providing improved maps of chaparral coupled with direct estimates of canopy attributes (eg. biomass, leaf area, fuel load)...Analysis focused on AVIRIS data collected on October 19, 1994.

AVIRIS chaparral California chaparral California w↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Multi-Gas Sensors for Enhanced Reliability of SOFC Operation

GE Research, in partnership with SUNY Polytechnic Institute (SUNY Poly), designed, built, and tested gas sensors for in situ monitoring of H 2 and CO anode tail gases produced with on-site steam reforming in solid oxide fuel cell (SOFC) systems. The knowledge of the H 2 /CO ratio of these anode tail gases should allow accurate determination and control of the efficiency of the reforming process in the SOFC system and should deliver a lower operating cost for SOFC customers. The project objectives were to achieve multi-gas monitoring capability with a single multivariable sensor, and to sustain this performance in the presence of gaseous interferences and a potential poison for the sensor. The duration of the project was 24 months with the project structure that included three technical tasks such as (1) development of design rules of photonic nanostructures for H 2 and CO gas detection, (2) laboratory validation of photonic nanostructures for selective H 2 and CO gas detection, and (3) validation of photonic nanostructures for initial stability and poison-resistance against H 2 S. To build multivariable sensors for selective H 2 and CO gas detection in the presence of interferences, we expanded our earlier knowledge of multi-gas sensors into new fabrication and functionalization methodologies as well as into new methodologies for the spectral data analysis of multi-gas responses. We have advanced our design rules of the three-dimensional (3D) photonic nanostructures that allowed detection of H 2 and CO at high temperatures as individual gases and as their mixtures and rejection of interferences such as CO 2 , H 2 O, CH 4 , and other hydrocarbons for SOFC applications. Our advanced design rules should be attractive for building the new generation of cost-effective industrial sensors. Stability and poison resistance of our 3D photonic nanostructures was tested in the laboratory conditions. While initially we utilized conventional machine learning data analysis tools, we have found that they were unable to correct for the sensor drift. Thus, we have implemented new methods of machine learning for the analysis of our spectral data. These learnings pave the way to move the future studies into advanced testing of effects of interferences, aging and field tests. In future, our work will continue to advance our sensing designs to operate in conditions with known and unknown interferences by implementing nanostructures with enhanced spectral diversity of responses to gaseous species of interest and interferences. Our systematic reduction of technical risks in this completed project and in future studies will ensure transition of this sensing technology to commercialization.

03 NATURAL GAS↗

A METHODOLOGY FOR DETERMINING THE DOSE RATE FOR BOUNDING MASS LIMITS IN A 9977 PACKAGING

The Small Gram Quantity (SGQ) concept is based on the understanding that the hazards associated with the shipment of a radioactive material are directly proportional to its mass. This study describes a methodology that estimates the acceptable masses for several neutron and gamma emitting isotopes that can be shipped in a 9977 Package compliant with the Title 10 of the Code of Federal Regulations, Part 71 (10CFR71) external radiation level limits. 10CFR71.33 states that a shipping application identifies the radioactive and fissile materials at their maximum quantity and provides an evaluation demonstrating compliance with the external radiation standards. Since rather small amounts of some isotopes emit sufficiently strong radiation to produce a large external dose rate, quantifying of the dose rate for a proposed content is a challenging issue for the SGQ approach. It is essential to quantify external radiation levels from several common gamma and neutron sources that can be safely placed in a specific packaging, to ensure compliance with federal regulations. A methodology was established for determining the dose rate for bounding mass limits for a set of isotopes in the Model 9977 Shipping Package. Calculations were performed to estimate external radiation levels using the MCNP radiation transport code to develop a set of response multipliers (Green's functions) for 'dose per source particle' for each neutron and photon spectral group. The source spectrum from one gram of each isotope was folded with the response multipliers to generate the dose rate per gram of each isotope in the 9977 shipping package and its associated shielded containers. The maximum amount of a single isotope that could be shipped within the regulatory limits for dose rate at the surface was determined. For a package containing a mixture of isotopes, the acceptability for shipment can be determined by a sum of fractions approach. Furthermore, the results of this analysis can be easily extended to additional radioisotopes by simply evaluating the neutron and/or photon spectra of those isotopes and folding the spectral data with the Green's functions provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantitative analysis of Cu XANES spectra using linear combination fitting of binary mixtures simulated by FEFF9

We report x-ray absorption near edge structure (XANES) is a powerful tool to probe the fingerprint of local structures, and when coupled with X-ray microscopy, the small spot size enables one to probe very specific regions of interest in a device or material, e.g. interfaces/bulk, different grains, good/bad electrical areas. In this work, we investigate the use of linear combination fitting (LCF) of XANES spectra for the particular case of Cu doping in CdTe. We show that the experimental data seem to be accurately represented by standards of Cu 2 Te and its substoichiometric counterpart, Cu 1.43 Te. We use Cu in CdTe as a case study to evaluate the accuracy of linear combination fitting using simulated standards, given that experimental standards for certain phases (e.g. Cu 1.43 Te) or defect structures (e.g. vacancies) cannot be readily obtained. We discuss how spectral features of the FEFF9-simulated standards, fitting ranges, and noise levels all dictate the accuracy of this type of analysis. We show that the greater the spectral difference between the two standards, the better the LCF is able to differentiate between the two structures and to tolerate experimental noise. Finally, we estimate the error of the fitted weights for different spectral features and noise levels and propose a framework to study local structures semi-quantitatively by using binary mixtures of FEFF9-simulated standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the origin of the two-component structure of broad-line region by reverberation mapping of an extremely variable quasar

ABSTRACT The physical origins of quasar components, such as the broad-line region (BLR) and dust torus, remain under debate. To gain insights into them, we focused on changing-state quasars (CSQs) which provide a unique perspective through structural changes associated with accretion disc state transitions. We targeted SDSS J125809.31+351943.0, an extremely variable CSQ, to study its central core structure and kinematics. We conducted reverberation mapping with optical spectroscopy to explore the structure of the BLR and estimate the black hole mass. The results from Hβ reverberation mapping indicated a black hole mass of $10^{9.64^{+0.11}_{-0.20}}\rm {M_\odot }$. Additionally, we analysed variations in the optical to X-ray spectral indices, αox, before and after the state transition, to investigate the accretion disc. These variations in αox and the Eddington ratio (from 0.4 per cent to 2.4 per cent) exhibitied behaviour similar to state transitions observed in X-ray binary systems. Spectral analysis of Hβ revealed a predominantly double-peaked profile during dim periods, transitioning to include a single-peaked component as the quasar brightened, suggesting that Hβ contains a mixture of two components. Each of these components has its distinct characteristics: the first is a double-peaked profile that remains stable despite changes in the accretion rate, while the second is a variable single-peaked profile. Using time-lags from reverberation mapping, we estimated the spatial relationships between these BLR components, the accretion disc, and the dust torus. Our results suggest that the BLR consists of two distinct components, each differing in location and origin.

Nagoshi, Shumpei (ORCID:0000000326504322)↗