Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Maximizing Yield with Improved Single-Axis Backtracking on Cross-Axis Slopes

Many tracking PV systems avoid row-to-row shading by backtracking in morning and afternoon. Because the common single-axis backtracking implementation assumes the array is in a horizontal plane, it does not fully prevent row-to-row shading in arrays installed on cross-axis slopes, e.g. an east-west slope for a tracker with north-south axis alignment. This paper presents the simulated effect of reduced self-shading on annual production with two modified backtracking strategies. Depending on the array geometry and the steepness of the cross-axis grade, using a modified backtracking strategy improved annual yield by 3-10%.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Power Loss and Safety Risks - Recoverable vs. Non-Recoverable?

This presentation presents an update to the PV fleet analysis on PV system degradation. A median system degradation of -0.7 %/year was found for almost 5000 inverter traces. No significant difference between silicon and CdTe technologies were found. Systems with trackers showed a slightly higher degradation. Silicon technologies such as PERC and heterojunction showed degradation similar to conventional technologies but also showed different degradation mechanisms. To achieve long lifetimes early failure must be minimized through qualification testing. Rapid detection during normal life is important as is the control of bill of materials in modules.

degradation↗

Wafer integrated micro‐scale concentrating photovoltaics

Abstract A novel micro‐scale photovoltaic concept, Wafer Integrated Micro‐scale Photovoltaics (WPV), is proposed, analyzed, and experimentally demonstrated. The WPV concept seamlessly integrates multijunction micro‐cells with a multi‐functional silicon platform that simultaneously provides optical concentration, hybrid PV/CPV architecture, and mechanical alignment features. Fabrication and optical performance characterization of the Si platform are described in this paper. Over 100% improvement in the concentration‐acceptance‐angle product ( CAP ) is demonstrated using the wafer‐embedded micro‐concentrating elements, leading to significantly reduced module material and fabrication costs, sufficient angular tolerance for low‐cost trackers, and an ultra‐compact optical architecture compatible with commercial flat panel infrastructures. The development of a prototypical module with a 400× concentration ratio is described. Outdoor optical characterization of the module shows acceptance angles of ±1.7° and ±2.5° for 90% of on‐axis power and full‐width‐half‐maximum, respectively. The projected performance of the PV/CPV hybrid architecture illustrates its potential for cost‐effective collection of both direct and diffuse sunlight, thereby extending the geographic and market domains for cost‐effective PV system deployment. Leveraging low‐cost micro‐fabrication and high‐level integration techniques, the WPV approach presents a promising route to combine the high performance of multijunction solar cells and the low costs of flat‐plate Si PV systems.

Li, Duanhui↗

Automating Detection and Diagnosis of Faults, Failures, and Underperformance in PV Plants

The project developed hybrid physics-based and machine-learning methods for near-real-time detection of balance-of-system faults (e.g., string, combiner, and tracker outages) in utility-scale Photovoltaic plants, achieving over 50% true positive rates with under 10% false positives and significantly reducing engineering setup time. In the extended phase, the scope expanded to plant-level underperformance analysis and industry benchmarking through the SUPER.epri.com platform. SUPER standardizes data processing and performance metrics across more than 9 GWac and 120+ plants, enabling robust comparisons and insights into loss rates, inverter downtime, and capacity degradation.

14 SOLAR ENERGY↗

Solar Transposition Modeling via Deep Neural Networks With Sky Images

This article presents a notable advance toward the development of a new method of increasing the single-axis tracking photovoltaic (PV) system power output by improving the determination and near-term prediction of the optimum module tilt angle. The tilt angle of the plane receiving the greatest total irradiance changes with Sun position and atmospheric conditions including cloud formation and movement, aerosols, and particulate loading, as well as varying albedo within a module's field of view. In this article, we present a multi-input convolutional neural network that can create a profile of plane-of-array irradiance versus surface tilt angle over a full 180° arc from horizon to horizon. As input, the neural network uses the calculated solar position and clear-sky irradiance values, along with sky images. The target irradiance values are provided by the multiplanar irradiance sensor (MPIS). In order to account for varying irradiance conditions, the MPIS signal is normalized by the theoretical clear-sky global horizontal irradiance. Using this information, the neural network outputs an N -dimensional vector, where N is the number of points to approximate the MPIS curve via Fourier resampling. The output vector of the model is smoothed with a Gaussian kernel to account for error in the downsamping and subsequent upsampling steps, as well as to smooth the unconstrained output of the model. Furthermore, these profiles may be used to perform near-term prediction of angular irradiance, which can then inform the movement of a PV tracker.

42 ENGINEERING↗

Economic Competitiveness of U.S. Utility-Scale Photovoltaics Systems in 2015: Regional Cost Modeling of Installed Cost ($/W) and LCOE ($/kWh)

Utility-scale photovoltaics (PV) system growth is largely driven by the economic metrics of total installed costs and levelized cost of electricity (LCOE), which differ by region. This study details regional cost factors, including environment (wind speed and snow loads), labor costs, material costs, sales taxes, and permitting costs using a new system-level bottom-up cost modeling approach. We use this model to identify regional all-in PV installed costs for fixed-tilt and one-axis tracker systems in the United States with consideration of union and non-union labor costs in 2015. LCOEs using those regional installed costs are then modeled and spatially presented. Finally, we assess the cost reduction opportunities of increasing module conversion efficiencies on PV system costs in order to indicate the possible economic impacts of module technology advancements and help future research and development (R&D) effects in the context of U.S. SunShot targets.

14 SOLAR ENERGY↗

Improvements to PVWatts for Fixed and One-Axis Tracking Systems

This work presents improvements to the widely used NREL PVWatts photovoltaic system energy model to improve modeling accuracy for typical fixed and one axis system designs. The aim is to calculate losses in the PV system assuming typical modern system design practices, while maintaining simplicity by keeping the required set of input parameters small. These improvements allow users to more credibly and quickly evaluate competing system designs in early stage feasibility. Common submodels for module cover, spectral, snow, tracker, transformer, plant controller, and self-shading losses, in addition to a bifacial gain option, are incorporated into the PVWatts model, and are shown to improve PVWatts' system performance prediction capabilities without major impact to ease of use. We anticipate including these improvements in a future release of NREL's open source PVWatts code, and some of the features may become available in the System Advisor Model (SAM) desktop software as well as the popular PVWatts web application.

14 SOLAR ENERGY↗

A new class of tandems: Optically coupled III-V/silicon module with outdoor efficiency exceeding 30%

The aim of this project was to introduce a new class of technology—that of high-efficiency silicon-based tandem photovoltaic (PV) modules—that, with follow-on development, has a clear path to reduced levelized cost of electricity (LCOE) for utility-scale power generation. In particular, the objective of the project was to demonstrate the first 30%-efficient III-V/silicon module in outdoor conditions using a tandem geometry in which the sub-cells are detached physically but coupled optically. In present PV power plants installed in the US, the module makes up only approximately one-third of the cost; area-dependent balance-of-systems (BOS) costs such as installation materials, labor, land, and site prep made up an additional third, and area-independent BOS costs round out the final third. With this pricing structure, (annually averaged) module efficiency is a clear market driver: increase the annual energy output per module and the effective costs translated into $/W of both the module and the area-dependent BOS—two-thirds of the total cost—decrease proportionately. However, the dominant PV technology—flat-plate silicon modules—is reaching its theoretical efficiency limit, and thus a tandem technology in which silicon is coupled with a wider-bandgap cell is a promising route to remain responsive to market forces. As it is not trivial to couple silicon with other cells in conventional two-terminal geometries due to, e.g., lattice mismatch, this project introduced a new, four-terminal configuration using a “PVMirror.” A PVMirror utilizes PV cells as a three-in-one technology—they act as a concentrating mirror, spectrum splitter, and high-efficiency light-to-electricity converter. Light is incident upon a full-aperture dichroic mirror that reflects visible light and transmits infrared light. The transmitted light is absorbed in silicon PV cells that are placed behind the dichroic mirror and that convert IR photons to electricity with high efficiency. The dichroic mirror and silicon PV cells are affixed to a curved glass trough that tracks the sun about a single, North-South axis such that the reflected VIS light is concentrated at a common line focus, at which is placed a second, wider-bandgap GaAs PV cell having high efficiency at shorter wavelengths. The innovation of PVMirrors lies in their design, which maximizes annual energy output and minimizes the constraints placed on the sub-cells. In particular, the cells are free of lattice- and current-matching restrictions, neither cell requires a transparent rear electrode, and either sub-cell can be placed at the focus depending on their relative costs. Furthermore, the greatest benefit of PVMirrors is that they make use of a portion of the diffuse light whereas concentrator tandems cannot. This results in a benefit in energy yield and extends PVMirrors’ competitive range. Over the course of this one-year project, a silicon PVMirror and GaAs receiver were fabricated, characterized, and placed outdoors on a sun tracker, where the efficiency of the tandem “module” was measured for three days. Notable results include the first demonstration of this flexible tandem configuration, a maximum tandem efficiency of 29.6% (just shy of the 30% overall project goal), successful conversion of diffuse light into electricity, a thorough loss analysis indicating a path to over 31% efficiency, and a roadmap to cost-competitive PVMirror tandems using a wide-bandgap polycrystalline PVMirror and a silicon receiver. Development of a >18%-efficient wide-bandgap polycrystalline cell—the key enabler of this envisioned tandem—should be a future research focus. This project has laid the groundwork for a PV technology that, with continued development, has the potential to reach LCOEs as low as $0.03/kWh according to our calculations. Such a system would provide the public with inexpensive, clean solar power.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Grid Support Functionality Testing for Florida Power and Light

This report describes the results of laboratory testing of advanced photovoltaic (PV) inverter testing undertaken by the National Renewable Energy Laboratory (NREL) on behalf of the Florida Power and Light Company (FPL). FPL recently commissioned a 1.1 MW-AC PV installation on a solar carport at the Daytona International Speedway in Daytona Beach, Florida. In addition to providing a source of clean energy production, the site serves as a live test bed with 36 different PV inverters from eight different manufacturers. Each inverter type has varied support for advanced grid support functions (GSFs) that are becoming increasingly commonplace, and are being required through revised interconnection standards such as UL1741, IEEE1547, and California (CA) Rule 21. FPL is interested in evaluating the trade-offs between different GSFs, their compliance to emerging standards, and their effects on efficiency and reliability. NREL has provided a controlled laboratory environment to undertake such a study. This work covered nine different classes of tests to compare inverter capabilities and performance for four different inverters that were selected by FPL. The test inverters were all three-phase models rated between 24-36 kW, and containing multiple PV input power point trackers. Advanced grid support functions were tested for functional behavior, and included fixed power factor operation, voltage-ride through, frequency ride-through, volt-var control, and frequency-Watt control. Response to abnormal grid conditions with GSFs enabled was studied through anti-islanding, fault, and load rejection overvoltage tests. Finally, efficiency was evaluated across a range of operating conditions that included power factor, output power, and input voltage variations. Test procedures were derived from requirements of a draft revision of UL741, CA Rule 21, and/or previous studies at NREL. This reports summarizes the results of each test case, providing a comparative performance analysis between the four test inverters. Inverters were mostly able to meet the requirements of their stated GSF capabilities, with deviations from expected results discussed throughout the report. There were mixed results across the range of abnormal tests, and results were often dependent on the capability of each test inverter to deploy the GSFs of interest. Detailed test data has been provided to FPL to support future decision making with respect to inverter selection and GSF deployment in the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems: Preprint

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated through ray-trace simulations and found to cause rear irradiance shading factors between 2% to 8% for systems without gap between the modules in 2-UP configuration. Inclusion of a gap between the modules can offset the shading factor. Electrical mismatch is also evaluated for the various configurations, and a methodology to apply shading factor and electrical mismatch loss to rear irradiance from the calculated loss in DC power, which averages 1% for the systems explored here, is proposed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Global Techno-Economic Performance of Bifacial and Tracking Photovoltaic Systems

Although most of the current photovoltaic (PV) system installations use monofacial modules with fixed-tilt mounting structures, bifacial modules, trackers, and the combination of them are also getting more attention as potential candidates to further reduce the PV levelized cost of electricity (LCOE). This work is then the first to present a worldwide analysis on the yield potential and cost-effectiveness of PV farms composed of monofacial fixed-tilt and single/dual (1T/2T) tracker installations, as well as their bifacial counterparts. Our approach starts by estimating the irradiance reaching the front and rear surface of the modules for the different system designs (validated based on data from real PV systems and results from the literature) to estimate their energy production (row-row shading is neglected). Subsequently, the overall system cost during their 25-year lifetime is factored in, and LCOE is obtained. The results reveal that bifacial-1T installations increase energy yield by 35% and reach the lowest LCOE for the majority of the world (93.1% of the land area). Although dual axis trackers achieve the highest energy generation — especially for bifacial modules — their cost is still too high, and are therefore not as cost-effective. Sensitivity analyses based on the Monte Carlo and region sensitivity approach are performed to analyze the impact of input assumptions on the calculated LCOE. These reveal that our conclusions are robust in general but exact configuration to choose depends on specific site conditions. This investigation is not only of interest to the scientific community, but also can be used as a guide for PV installation companies and investors to determine the most suitable technology for a particular location.

14 SOLAR ENERGY↗

Improved CdTe PLR Estimates: Self-Shading and Spectral Mismatch

The RdTools year-on-year method of estimating performance loss rate (PLR) employs a simple normalization to remove the confounding effect of irradiance and temperature variation. However, the normalization's assumption that PV production scales linearly with in-plane broadband irradiance is a worse approximation for CdTe and other technologies with larger spectral sensitivities than it is for the more common c-Si technology. Additionally, CdTe systems using single-axis trackers (-20% of installed US utility-scale capacity) are subject to self-shading in the morning and afternoon, introducing another nonlinearity between PV output and broadband irradiance. Ignoring these effects may subject the estimated PLR to increased uncertainty, and perhaps bias, depending on the character of their short- and long-term variability. In this work we show that including self-shading and spectral mismatch models in the normalization for tracking CdTe systems can result not only in tighter PLR confidence intervals but different median PLRs as well. The shading and spectral models are kept simple to maintain consistency with the RdTools ethos of not requiring detailed system metadata or unusual measurements.

CdTe↗

Estimation of the potential array output charge in the performance analysis of stand-alone photovoltaic systems without MPPT (Case study: Mediterranean climate)

The potential array output energy, E{sub P}, stated by the Joint Research Centre (JRC) in their European Guidelines for the Assessment of Photovoltaic Plants and the IEC Standard 61724 does not estimate properly the potential array output of stand-alone photovoltaic (SAPV) systems without maximum power point tracker (MPPT) as it is the case for SAPV systems with MPPT and grid connected systems. In this way, the main purpose of this paper is to validate an expression that compromises simplicity and accuracy when estimating the potential array output of SAPV systems without MPPT. This issue can be of high interest to photovoltaic (PV) practitioners and experts as it can improve the analysis performance of this type of systems, helping to discriminate better the different losses in this kind of systems. Furthermore, a study of the array potential estimation through different expressions will be developed in order to evaluate which matches better the array potential output in SAPV system without MPPT. Although the analysis will be focused especially in Mediterranean climates, it will be derived some general conclusions that can be considered in other climates. (author)

14 SOLAR ENERGY↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

PSCAD Modules Representing PV Generator

Photovoltaic power plants (PVPs) have been growing in size, and the installation time is very short. With the cost of photovoltaic (PV) panels dropping in recent years, it can be predicted that in the next 10 years the contribution of PVPs to the total number of renewable energy power plants will grow significantly. In this project, the National Renewable Energy Laboratory (NREL) developed a dynamic modeling of the modules to be used as building blocks to develop simulation models of single PV arrays, expanded to include Maximum Power Point Tracker (MPPT), expanded to include PV inverter, or expanded to cover an entire PVP. The focus of the investigation and complexity of the simulation determines the components that must be included in the simulation. The development of the PV inverter was covered in detail, including the control diagrams. Both the current-regulated voltage source inverter and the current-regulated current source inverter were developed in PSCAD. Various operations of the PV inverters were simulated under normal and abnormal conditions. Symmetrical and unsymmetrical faults were simulated, presented, and discussed. Both the three-phase analysis and the symmetrical component analysis were included to clarify the understanding of unsymmetrical faults. The dynamic model validation was based on the testing data provided by SCE. Testing was conducted at SCE with the focus on the grid interface behavior of the PV inverter under different faults and disturbances. The dynamic model validation covers both the symmetrical and unsymmetrical faults.

14 SOLAR ENERGY↗

THEORY OF DISPERSED FIXED-DELAY INTERFEROMETRY FOR RADIAL VELOCITY EXOPLANET SEARCHES

The dispersed fixed-delay interferometer (DFDI) represents a new instrument concept for high-precision radial velocity (RV) surveys for extrasolar planets. A combination of a Michelson interferometer and a medium-resolution spectrograph, it has the potential for performing multi-object surveys, where most previous RV techniques have been limited to observing only one target at a time. Because of the large sample of extrasolar planets needed to better understand planetary formation, evolution, and prevalence, this new technique represents a logical next step in instrumentation for RV extrasolar planet searches, and has been proven with the single-object Exoplanet Tracker (ET) at Kitt Peak National Observatory, and the multi-object W. M. Keck/MARVELS Exoplanet Tracker at Apache Point Observatory. The development of the ET instruments has necessitated fleshing out a detailed understanding of the physical principles of the DFDI technique. Here we summarize the fundamental theoretical material needed to understand the technique and provide an overview of the physics underlying the instrument's working. We also derive some useful analytical formulae that can be used to estimate the level of various sources of error generic to the technique, such as photon shot noise when using a fiducial reference spectrum, contamination by secondary spectra (e.g., crowded sources, spectroscopic binaries, or moonlight contamination), residual interferometer comb, and reference cross-talk error. Following this, we show that the use of a traditional gas absorption fiducial reference with a DFDI can incur significant systematic errors that must be taken into account at the precision levels required to detect extrasolar planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on 1-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial modules in 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated and found to reduce rear-irradiance averages without any torque-tube shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored. shading by 0.1 to 12% for metallic and black absorptive torque tubes respectively for a clear-sky day. This paper will compare modeled to measured rear-irradiance profiles, and propose a recommended range of rear-shading loss factors for different geometry conditions. The effect of rear-irradiance distribution into electrical mismatch loss will also be explored.

14 SOLAR ENERGY↗