Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software estimation,”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Substation Secondary Asset Health Monitoring and Management System (SSHM)

Electric Power Group, LLC (EPG) was awarded DOE OE0000850 to design, develop, and demonstrate a real-time software application for substation secondary equipment health monitoring and management at host utility American Electric Power (AEP), a cost share partner. This project addresses the need for monitoring substation equipment health and providing operators with tools to identify and take pre-emptive action to avoid catastrophic equipment failure. By monitoring synchrophasor data in real time, data anomalies that indicate potential asset failure can be detected and alerts can be sent to operators in time to take corrective actions. EPG developed two data driven algorithms to identify abnormal equipment signature patterns as well as a method using substation linear state estimation (SLSE). The software has been deployed on hardened PC’s and tested and validated for cost share partner AEP’s substations - 138kV and 765 kV. The SSHM software has been accepted by AEP and final demonstration of DOE - OE0000850 for AEP and DOE was successfully completed on March 17th, 2020. EPG developed the Substation Secondary Asset Health Monitoring (SSHM) Platform to analyze equipment failure signatures in PMU data and alert substation personnel when pre-emptive inspection, repairs and other actions are warranted to prevent potential catastrophic failures. This is the first system that automatically monitors the health of substation secondary assets and alerts users to emerging failures using synchrophasor measurements. SSHM uses high resolution PMU data from PTs, CTs, and CCVTs to analyze equipment signatures and identify anomalies that are precursor indicators of potential equipment failure. When an anomaly is detected, there is a likelihood of potential failure of monitored equipment, the system alerts the user with visual alarms including alarm trend charts and indicator lights on a oneline diagram of the substation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ProZES: the methodology and software tool for assessment of assigned share of radiation in probability of cancer occurrence

ProZES is a software tool for estimating the probability that a given cancer was caused by preceding exposure to ionising radiation. ProZES calculates this probability, the assigned share, for solid cancers and hematopoietic malignant diseases, in cases of exposures to low-LET radiation, and for lung cancer in cases of exposure to radon. User-specified inputs include birth year, sex, type of diagnosed cancer, age at diagnosis, radiation exposure history and characteristics, and smoking behaviour for lung cancer. Cancer risk models are an essential part of ProZES. Linking disease and exposure to radiation involves several methodological aspects, and assessment of uncertainties received particular attention. ProZES systematically uses the principle of multi-model inference. Models of radiation risk were either newly developed or critically re-evaluated for ProZES, including dedicated models for frequent types of cancer and, for less common diseases, models for groups of functionally similar cancer sites. The low-LET models originate mostly from the study of atomic bomb survivors in Hiroshima and Nagasaki. Risks predicted by these models are adjusted to be applicable to the population of Germany and to different time periods. Adjustment factors for low dose rates and for a reduced risk during the minimum latency time between exposure and cancer are also applied. The development of the methodology and software was initiated and supported by the German Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (BMU) taking up advice by the German Commission on Radiological Protection (SSK, Strahlenschutzkommission). These provide the scientific basis to support decision making on compensation claims regarding malignancies following occupational exposure to radiation in Germany.

97 MATHEMATICS AND COMPUTING↗

MO-F-CAMPUS-I-01: Accuracy of Radiologists Interpretation of Mammographic Breast Density

Purpose: Several commercial and non-commercial software and techniques are available for determining breast density from mammograms. However, where mandated by law the breast density information communicated to the subject/patient is based on radiologist’s interpretation of breast density from mammograms. Several studies have reported on the concordance among radiologists in interpreting mammographic breast density. In this work, we investigated the accuracy of radiologist’s interpretation of breast density. Methods: Volumetric breast density (VBD) determined from 134 unilateral dedicated breast CT scans from 134 subjects was considered the truth. An MQSA-qualified study radiologist with more than 20 years of breast imaging experience reviewed the DICOM “for presentation” standard 2-view mammograms of the corresponding breasts and assigned BIRADS breast density categories. For statistical analysis, the breast density categories were dichotomized in two ways; fatty vs. dense breasts where “fatty” corresponds to BIRADS breast density categories A/B, and “dense” corresponds to BIRADS breast density categories C/D, and extremely dense vs. fatty to heterogeneously dense breasts, where extremely dense corresponds to BIRADS breast density category D and BIRADS breast density categories A through C were grouped as fatty to heterogeneously dense breasts. Logistic regression models (SAS 9.3) were used to determine the association between radiologist’s interpretation of breast density and VBD from breast CT, from which the area under the ROC (AUC) was determined. Results: Both logistic regression models were statistically significant (Likelihood Ratio test, p<0.0001). The accuracy (AUC) of the study radiologist for classification of fatty vs. dense breasts was 88.4% (95% CI: 83–94%) and for classification of extremely dense breast was 94.3% (95% CI: 90–98%). Conclusion: The accuracy of the radiologist in classifying dense and extremely dense breasts is high. Considering the variability in VBD estimates from commercial software, the breast density information communicated to the patient should be based on radiologist’s interpretation. This work was supported in part by NIH R21 CA176470 and R21 CA134128. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Parametric analysis on optimized design of hybrid solar power plants

There is increasing interest in utility-scale solar power plants with storage which can flexibly dispatch renewable energy to the grid. However, plant design possesses many degrees of freedom and non-obvious trade-offs in performance. Software tools can estimate or optimize the performance of a specific plant configuration under market and weather conditions of interest; the associated cost parameters and operating assumptions strongly influence estimates of plant performance and decisions regarding optimal sizing. We employ the National Renewable Energy Laboratory's Hybrid Optimization and Performance Platform, which incorporates optimal dispatch when evaluating plant performance, and investigate the sensitivity to weather and market conditions, operating limitations, and the presence of a capacity-based incentive. We demonstrate changes in plant performance and optimal sizing with respect to these inputs and discuss implications. Here results show that PV-with-battery designs are more profitable under our assumptions, but that designs including a concentrated solar power (CSP) system produce significantly greater annual energy; and that CSP-with-thermal energy storage designs maximizing the benefit-to-cost ratio have an input-dependent linear relationship between the CSP field solar multiple and the hours of storage as the project budget varies.

14 SOLAR ENERGY↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Oscillator-Qubit Quantum Processors: Instruction Set Architectures, Abstract Machine Models, and Applications

This tutorial offers a pedagogical guide to hybrid quantum processors that integrate discrete-variable (DV) qubits and continuous-variable (CV) oscillators. Aimed at computer scientists, engineers, and physicists, it provides an overview of the experimental, algorithmic, and architectural aspects of this novel and rapidly developing hardware model. Experimental realizations of this model include superconducting, trapped-ion, and neutral-atom platforms. By combining DV and CV components, hybrid oscillator-qubit processors enable a powerful new paradigm that offers complementary strengths for quantum control, error correction, computation, and simulation. Working toward the goal of a full-stack system connecting applications to CV-DV hardware, we define and formulate abstract machine models and instruction set architectures. These essential abstractions enable codesign of hardware and software, and resource estimation for exploring the potential of current and future hardware for computational and simulation tasks. Using these abstractions, we present both new and existing examples that illustrate the benefits of hybrid CV-DV processors relative to traditional DV-only hardware in computation as well as quantum simulation of physical models. Examples include algorithms for transferring states between DV and CV systems, performing the quantum Fourier transform, and simulation of lattice gauge theories. Relative to qubit-only hardware, the bosonic degrees of freedom natively available in hybrid architectures can substantially reduce the circuit complexity of simulations for physical models containing bosons. A key technique is the extension of quantum signal processing ideas to CV-DV systems. This work is intended to serve as a timely and comprehensive guide to this relatively unexplored yet promising approach to quantum computation and to provide a road map to guide future development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and analysis of magnetic coil for relativistic magnetron

This paper presents the design of magnetic coil for relativistic magnetron (RM) for LIA (Linear Induction Accelerator)-400 systems. Vacuum improves the efficiency of RM for HPM generation. Magnetic field in RM is very critical parameter and should be nearly constant in the active region. Typical coils are helical in nature, which have multi turns of varying radius. Magnetic field calculation of such coils with basic equations of Helmholtz coils or solenoid with mean radius can only give estimation. Field computational softwares like CST require small mesh size and boundary at very far so consume large memory and take very much time. Helical coils are simplified such that the basic law of magnetic field calculation i.e. Bio-Savart law can be applied with less complexity. Pairs of spiral coils have been analyzed for magnetic field and Lorenz's force. The approach is field experimentally validated. (author)

43 PARTICLE ACCELERATORS↗

Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA

Purpose: The purpose of this work is to explore the usefulness of the gamma passing rate metric for per-patient, pretreatment dose QA and to validate a novel patient-dose/DVH-based method and its accuracy and correlation. Specifically, correlations between: (1) gamma passing rates for three 3D dosimeter detector geometries vs clinically relevant patient DVH-based metrics; (2) Gamma passing rates of whole patient dose grids vs DVH-based metrics, (3) gamma passing rates filtered by region of interest (ROI) vs DVH-based metrics, and (4) the capability of a novel software algorithm that estimates corrected patient Dose-DVH based on conventional phan-tom QA data are analyzed. Methods: Ninety six unique ''imperfect'' step-and-shoot IMRT plans were generated by applying four different types of errors on 24 clinical Head/Neck patients. The 3D patient doses as well as the dose to a cylindrical QA phantom were then recalculated using an error-free beam model to serve as a simulated measurement for comparison. Resulting deviations to the planned vs simulated measured DVH-based metrics were generated, as were gamma passing rates for a variety of difference/distance criteria covering: dose-in-phantom comparisons and dose-in-patient comparisons, with the in-patient results calculated both over the whole grid and per-ROI volume. Finally, patient dose and DVH were predicted using the conventional per-beam planar data as input into a commercial ''planned dose perturbation'' (PDP) algorithm, and the results of these predicted DVH-based metrics were compared to the known values. Results: A range of weak to moderate correlations were found between clinically relevant patient DVH metrics (CTV-D95, parotid D{sub mean}, spinal cord D1cc, and larynx D{sub mean}) and both 3D detector and 3D patient gamma passing rate (3%/3 mm, 2%/2 mm) for dose-in-phantom along with dose-in-patient for both whole patient volume and filtered per-ROI. There was considerable scatter in the gamma passing rate vs DVH-based metric curves. However, for the same input data, the PDP estimates were in agreement with actual patient DVH results. Conclusions: Gamma passing rate, even if calculated based on patient dose grids, has generally weak correlation to critical patient DVH errors. However, the PDP algorithm was shown to accurately predict the DVH impact using conventional planar QA results. Using patient-DVH-based metrics IMRT QA allows per-patient dose QA to be based on metrics that are both sensitive and specific. Further studies are now required to analyze new processes and action levels associated with DVH-based metrics to ensure effectiveness and practicality in the clinical setting.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-114: A Practical Hybrid Method for Improving the Quality of CT-CBCT Deformable Image Registration for Head and Neck Radiotherapy

Purpose: Accurate deformable image registration (DIR) between CT and CBCT in H&N is challenging. In this study, we propose a practical hybrid method that uses not only the pixel intensities but also organ physical properties, structure volume of interest (VOI), and interactive local registrations. Methods: Five oropharyngeal cancer patients were selected retrospectively. For each patient, the planning CT was registered to the last fraction CBCT, where the anatomy difference was largest. A three step registration strategy was tested; Step1) DIR using pixel intensity only, Step2) DIR with additional use of structure VOI and rigidity penalty, and Step3) interactive local correction. For Step1, a public-domain open-source DIR algorithm was used (cubic B-spline, mutual information, steepest gradient optimization, and 4-level multi-resolution). For Step2, rigidity penalty was applied on bony anatomies and brain, and a structure VOI was used to handle the body truncation such as the shoulder cut-off on CBCT. Finally, in Step3, the registrations were reviewed on our in-house developed software and the erroneous areas were corrected via a local registration using level-set motion algorithm. Results: After Step1, there were considerable amount of registration errors in soft tissues and unrealistic stretching in the posterior to the neck and near the shoulder due to body truncation. The brain was also found deformed to a measurable extent near the superior border of CBCT. Such errors could be effectively removed by using a structure VOI and rigidity penalty. The rest of the local soft tissue error could be corrected using the interactive software tool. The estimated interactive correction time was approximately 5 minutes. Conclusion: The DIR using only the image pixel intensity was vulnerable to noise and body truncation. A corrective action was inevitable to achieve good quality of registrations. We found the proposed three-step hybrid method efficient and practical for CT/CBCT registrations in H&N. My department receives grant support from Industrial partners: (a) Varian Medical Systems, Palo Alto, CA, and (b) Philips HealthCare, Best, Netherlands.

60 APPLIED LIFE SCIENCES↗

MO-D-213-04: The Proximity to the Skin of PTV Affects PTV Coverage and Skin Dose for TomoTherapy

Purpose: The proximity to the skin surface of the PTV for the patients with skin disease could be a concern in terms of the PTV coverage and actual surface dose (SD). IMRT optimization algorithms increase the beam intensity close to the skin in order to compensate for lack of scattering material, leading to enhanced SD but potential hot spots. This study aims to investigate the effect of PTV proximity to the skin on planning and measured SD Methods: All measurements were done for 6 MV X-ray beam of Helical TomoTherapy. An anthropomorphic phantom was scanned in a CT simulator in a routine manner with thermoplastic mask immobilization. PTVs were created with varying distances to the skin of 0 mm -(PTV1), 1 mm- (PTV2), 2 mm-(PTV3) and 3 mm-(PTV4). Also, a 5 mm bolus was used with PTV1 (PTV5). All planning constraints were kept the same in all studies (hard constraint: 95% of the prescription dose covered 95% of the PTV). Gafchromic film (EBT3) was placed under the mask on the phantom surface, and the resulting dose was estimated using RIT software. Results: Optimizing the dose using different PTVs lead to average planned target doses of 10.8, 10.3, 10.2, 10.3 and 10.0 Gy, with maximum doses 12.2, 11.2, 11.1, 11.1 and 10.0 Gy for PTV1, PTV2, PTV3, PTV4 and PTV5, respectively. EBT3 measurements indicated a significant decrease of SD with skin distance by 12.7% (PTV1), 21.9% (PTV2), 24.8% (PTV3) and 28.4% (PTV4) comparing to prescription dose. Placement of a 5 mm bolus on the phantom surface resulted in a SD close to prescribed (+0.5%). Conclusion: This work provides a clear demonstration of the relationship between the skin dose and the PTV to the skin distance. The results indicate the necessity of a bolus even for TomoTherapy when high skin dose is required.

60 APPLIED LIFE SCIENCES↗

scANN

SAND2025-00656O scANN, also known as sampling by coinflips artificial neural networks, is a software tool that estimates uncertainty in artificial intelligence by performing Monte Carlo analysis on the weight matrices of feedforward neural networks. This computationally intensive process aims to explore the potential value added by future probabilistic hardware. The program’s output helps researchers gain insights into how probabilistic neural networks work. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

Platform Li-Ion Battery Risk Assessment Tool (CRADA Final Report)

Creare was awarded a Phase 1 STTR contract from the US Office of Naval Research, with a seven month period of performance from 6/28/2010 to 1/28/2011. The objectives of the STTR were to determine the feasibility of developing a software package for estimating reliability of battery packs, and develop a user interface to allow the designer to assess the overall impact on battery packs and host platforms for cell-level faults. NREL served as sub-tier partner to Creare, providing battery modeling and battery thermal safety expertise.

25 ENERGY STORAGE↗

A Computer Design Tool for Ceramic Receivers

Gen3 solar receivers and other components will experience a combination of high temperatures and high stress caused by thermal stress and internal pressure. Under these conditions metallic components, even those manufactured from nickel-based superalloys, have poor reliability. Engineering ceramics could be a solution, as these materials have excellent high temperature strength. However, accurately assessing the reliability of a ceramic component operating in these conditions requires an entirely different approach compared to metallic materials. This paper describes the implementation of statistical models for evaluating the reliability of high temperature ceramic components in srlife – an open-source software package for estimating the life of high temperature concentrating solar power equipment. This new capability allows users to make fair comparisons between competing metallic and ceramic component designs and to accurately assess the plant efficiency and economics of ceramic solar receivers and other components.

Messner, Mark (ORCID:0000000200404385)↗

Time-Dependent Failure Assessment of Ceramic Receivers

The outlet temperature targets for Gen 3 Concentrating Solar Power (CSP) systems pose a significant challenge to the structural reliability of high temperature metallic components, including those manufactured from nickel-based superalloys. Advanced ceramics present a potential solution due to their excellent high-temperature strength. However, accurate assessment of ceramic components requires an entirely different approach compared to metallic components. This paper describes the implementation of time-dependent reliability analysis of ceramic components in srlife – an open-source software package for estimating the life of high temperature CSP components. This new capability will allow high temperature CSP designers to make fair comparisons between competing metallic and ceramic designs and accurately assess the performance of different ceramic materials for CSP receivers and other components. The current version of the tool is available at https://github.com/Argonne-National-Laboratory/srlife.

Barua, Bipul (ORCID:0000000247184113)↗

Comparison of Thermal Diffusivity Degradation of Irradiated Zirlo and SiC-SiC Composite

Zirlo (Zircaloy cladding material from Westinghouse) has been widely used as the fuel cladding material in Light Water Reactors because of its high melting point, low susceptibility to corrosion, good thermal and mechanical shock resistance, and low degradation of mechanical properties under irradiation. But as Zirlo reacts with water at high temperature, which can trigger serious accidents, efforts have been made to explore better candidates to replace Zirlo in the water-cooled reactors. SiC-SiC composite is considered as one of the most viable options due to its comparable mechanical performances and corrosion resistance. However, one of the most important properties, thermal diffusivities of both Zirlo and SiC-SiC composite, and their degradation after irradiation, are not well known yet. Ion-irradiated samples are used to study the thermal property degradation caused by irradiation instead of the neutron-irradiated ones due to the significantly lower radioactivity. The microstructural damage is estimated from the software simulation SRIM/TRIM based on the energy and fluence of the ion, and the target material, and represented by DPA (displacement by atom). Different from neutron-irradiated samples, the damaged layer of ion-irradiated samples is only a few to a few tens of micrometers thick, and the damage is depth dependent. It is impossible to directly measure the bulk property change, and a microscale measurement technique is necessary. Laser-based photothermal reflectance technique is one of the ideal methods to measure local thermal conductivity and diffusivity with high spatial resolution. The main principle of this technique is to heat the solid sample using an intensity-modulated laser, and scan the sample with a constant intensity continuous-wave (CW) laser to detect the thermal wave propagation. On bulk, isotropic material, if the heating laser intensity is modulated as a sine wave, thermal diffusivity of the sample can be derived from the phase lag of the thermal wave, scan distance and modulation frequency in a straight forward manner. By using more specific analytical models, thermal conductivity and diffusivity in complicated cases, such as layered structure materials, composite materials, and/or anisotropic materials, are measurable as well. In this work, thermal diffusivity of the light damage layer of the post-irradiation Zirlo and SiC-SiC composite are measured and compared. The Zirlo sample is irradiated by Ni{sup 9+} ion, and SiC-SiC composite material is irradiated by Si{sup 7+} ion. The peak DPA of both sample is similar as ∼10. For ion-irradiated materials, DPA is known to increase with depth before it reaches the peak, and then sharply drop to zero. In term of light damage layer in this manuscript, we mean by the layer with a DPA smaller than 5% maximum value. In this layer DPA increases slowly and smoothly with depth, and the structure and thus thermal properties are more spatially uniform. For the SiC-SiC composite, the measurements are separately conducted on fibers along radial or axial direction, and on the matrix. Our measurement results show that with similar microstructural damage, thermal diffusivity of matrix SiC reduces more significantly than that of Zirlo. For fiber SiC that has a much lower thermal diffusivity than the matrix SiC before irradiation, the post-irradiation effect on thermal diffusivity is not obvious.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Battery State of Health Estimator: Cooperative Research and Development Final Report

NREL has developed a software tool to enable Renewance to estimate the degradation of batteries from basic information such as the type of battery and the application of that battery during its first life, so that used batteries may be evaluated for potential repurposing at low cost. This software tool utilizes NREL's BLAST-Lite battery degradation modeling code, which was updated with additional models for commercially produced lithium-ion batteries as a part of this CRADA. The software tool enables users to input details such as battery type and application so that lifetime estimates can be made without any programming or expert battery knowledge. The application input loads in saved values for parameters such as cycles per year, depth-of-discharge, and other battery operating parameters from a file defined by Renewance. These parameters may be modified to refine simulations for specific batteries. The software tool also incorporates a degradation model optimization tool, whereby existing battery degradation models may be tuned according to measured battery health. This ensures that new models still predict degradation behaviors expected from a certain battery chemistry, but with the overall degradation rate tuned to a specific battery make and model. The new model can then be saved for estimating the degradation of other similar batteries. An additional task was planned to utilize machine-learning to enable battery health diagnosis from rapid EIS measurements to accelerate the screening of used batteries. This task was not completed due to lack of available data for training a machine-learning model. CRADA benefit to DOE, Participant, and US Taxpayer: Further development of open-source software tool BLAST-Lite for predicting the lifetime of commercially produced Lithium-ion batteries (NREL SWR-22-69).

25 ENERGY STORAGE↗

AWE-ML: Averaged Weights for Explainable Machine Learning v. 1.0

This software uses averaged weighted estimators to classify instances and then explicate the individual decision process in classification. The software has state of the art performance in accuracy, while maintaining full explainability. It does this by calculating hierarchically averaged probabilities for a large class of feature combinations and updating them ‘on-the-fly’. On the fly updating also allows the model to be accurate, relative to the total dataset, maintaining accuracy in real-time, without a need to retrain the classifier.

Agarwal, Sapan↗

CheKiPEUQ

Parameter estimation for complex physical problems often suffers from finding 'solutions' that are not physically realistic. The CheKiPEUQ software provides tools for finding physically realistic parameter estimates.and CheKiPEUQ provide tools for making graphs of the parameter positions within parameter space as well as plots of the final simulation results. The primary purpose of the CheKiPEUQ software is to enable more physically realistic parameter estimation from comparing simulations to experiments. Specifically, when prior knowledge is available about the region of parameter space which is physically realistic and when the level of uncertainty from experiment can be estimated. The software is intentionally general and can be used for almost any type of simulation. The software is made in a user friendly manner so that users can simply enter the required data and then run the program, following guidelines provided by the authors along with some trial and error. Examples are provided. Users do not need to understand the methodology that will be namedi in the following sentences. While CheKiPEUQ can be used for conventional parameter estimation and other uses, the primary uses for CheKiPEUQ are: 1) Bayesian Parameter Estimation, 2) Bayesian Model Discrimination, 3) Bayesian Design of Experiments. For more information see the project website, documentation, examples, and related publications.

Savara, Aditya [Oak Ridge National Lab. (ORNL), Oa↗