Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Smoke Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The NASA pollution-reduction technology program for small jet aircraft engines

Three advanced combustor concepts, designed for the AiResearch TFE 731-2 turbofan engine, were evaluated in screening tests. Goals for carbon monoxide and unburned hydrocarbons were met or closely approached with two of the concepts with relatively modest departures from conventional combustor design practices. A more advanced premixing/prevaporizing combustor, while appearing to have the potential for meeting the oxides of nitrogen goal as well, will require extensive development to make it a practical combustion system. Smoke numbers for the two combustor concepts were well within the EPA smoke standard. Phase 2, Combustor-Engine Compatibility Testing, which is in its early stages, and planned Phase 3, Combustor-Engine Demonstration Testing, are also described.

Fear, J. S.↗

The NASA Pollution-Reduction Technology Program for small jet aircraft engines - A status report

A three-phase experimental program is described which has the objective of enabling EPA Class T1 jet engines to meet the 1979 EPA emissions standards. In Phase I, three advanced combustor concepts, designed for the AiResearch TFE 731-2 turbofan engine, were evaluated in screening tests. Goals for carbon monoxide and unburned hydrocarbons were met or closely approached with two of the concepts with relatively modest departures from conventional combustor design practices. A more advanced premixing/prevaporizing combustor, while appearing to have the potential for meeting the oxides of nitrogen goal as well, will require extensive development to make it a practical combustion system. Smoke numbers for the two combustor concepts which will be carried forward into Phase II of the program were well within the EPA smoke standard. Phase II, Combustor-Engine Compatibility Testing, which is in its early stages, and planned Phase III, Combustor-Engine Demonstration Testing, are also described.

Fear, J. S.↗

Particle Morphology and Elemental Composition of Smoke Generated by Overheating Common Spacecraft Materials

Fire safety in the indoor spacecraft environment is concerned with a unique set of fuels which are designed to not combust. Unlike terrestrial flaming fires, which often can consume an abundance of wood, paper and cloth, spacecraft fires are expected to be generated from overheating electronics consisting of flame resistant materials. Therefore, NASA prioritizes fire characterization research for these fuels undergoing oxidative pyrolysis in order to improve spacecraft fire detector design. A thermal precipitator designed and built for spacecraft fire safety test campaigns at the NASA White Sands Test Facility (WSTF) successfully collected an abundance of smoke particles from oxidative pyrolysis. A thorough microscopic characterization has been performed for ten types of smoke from common spacecraft materials or mixed materials heated at multiple temperatures using the following techniques: SEM, TEM, high resolution TEM, high resolution STEM and EDS. Resulting smoke particle morphologies and elemental compositions have been observed which are consistent with known thermal decomposition mechanisms in the literature and chemical make-up of the spacecraft fuels. Some conclusions about particle formation mechanisms are explored based on images of the microstructure of Teflon smoke particles and tar ball-like particles from Nomex fabric smoke.

Smoke↗

A multi-Physics Experiment for Low-Yield Nuclear Explosion Monitoring

A series of multi-physics experiments, referred to as Physics Experiment 1 (PE1) is underway at the United States’ Nevada National Security Site (NNSS). The PE1 series includes detonations of three underground chemical explosions in P-tunnel, with fully coupled (PE1 A), partially decoupled (PE1 D L ), and fully decoupled (PE1 B) emplacements. Canisters with gas tracers are imbedded in the explosives, and the tracers are released when the canister is destroyed by the detonation. A dedicated electromagnetic (EM) experiment (EMX) generates well-characterized EM signals at an underground location near the chemical explosive experiments. A series of atmospheric experiments (METEX, REACT, and METREX) release smoke and radioactive tracers around Aqueduct Mesa to test gas transport in complex topography. Each of the chemical explosive experiments includes a network of sensors to record seismic, acoustic, and electromagnetic waves, measurement of atmospheric conditions, and air sample collection for measurement of tracer concentration. EMX records EM signals underground and on the surface of Aqueduct Mesa. METEX, REACT, and METREX include measurement of atmospheric condition, as well as tracking smoke releases. REACT and METREX add low-level radioactive gas tracers to the atmospheric releases.

58 GEOSCIENCES↗

Evaluation of a staged fuel combustor for turboprop engines

Proposed EPA emission regulations require emission reduction by 1979 for various gas turbine engine classes. Extensive combustion technology advancements are required to meet the proposed regulations. The T56 turboprop engine requires CO, UHC, and smoke reduction. A staged fuel combustor design was tested on a combustion rig to evaluate emission reduction potential in turboprop engines from fuel zoning. The can-type combustor has separately fueled-pilot and main combustion zones in series. The main zone fueling system was arranged for potential incorporation into the T56 with minor or no modifications to the basic engine. Three combustor variable geometry systems were incorporated to evaluate various airflow distributions. Emission results with fixed geometry operation met all proposed EPA regulations over the EPA LTO cycle. CO reduction was 82 percent, UHC reduction was 96 percent, and smoke reduction was 84 percent. NOx increased 14 percent over the LTO cycle. At high power, NOx reduction was 40 to 55 percent. This NOx reduction has potential application to stationary gas turbine powerplants which have different EPA regulations.

Verdouw, A. J.↗

Aviation-fuel property effects on combustion

The fuel chemical property influence on a gas turbine combustor was studied using 25 test fuels. Fuel physical properties were de-emphasized by using fuel injectors which produce highly-atomized, and hence rapidly vaporizing sprays. A substantial fuel spray characterization effort was conducted to allow selection of nozzles which assured that such sprays were achieved for all fuels. The fuels were specified to cover the following wide ranges of chemical properties: hydrogen, 9.1 to 15 (wt) pct; total aromatics, 0 to 100 (vol) pct; and naphthalene, 0 to 30 (vol) pct. standard fuels (e.g., Jet A, JP4), speciality products (e.g., decalin, xylene tower bottoms) and special fuel blends were included. The latter group included six, 4-component blends prepared to achieve parametric variations in fuel hydrogen, total aromatics and naphthalene contents. The principle influences of fuel chemical properties on the combustor behavior were reflected by the radiation, liner temperature, and exhaust smoke number (or equivalently, soot number density) data. Test results indicated that naphthalene content strongly influenced the radiative heat load while parametric variations in total aromatics did not.

Rosfjord, T. J.↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex®, M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton®, and mixtures of PTFE and Kapton®. Furnace temperatures ranged from 340o to 640o C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Smoke↗

Materials Combustion Testing and Combustion Product Sensor Evaluations in FY12

NASA Centers continue to collaborate to characterize the chemical species and smoke particles generated by the combustion of current space-rated non-metallic materials including fluoropolymers. This paper describes the results of tests conducted February through September 2012 to identify optimal chemical markers both for augmenting particle-based fire detection methods and for monitoring the post-fire cleanup phase in human spacecraft. These studies follow up on testing conducted in August 2010 and reported at ICES 2011. The tests were conducted at the NASA White Sands Test Facility in a custom glove box designed for burning fractional gram quantities of materials under varying heating profiles. The 623 L chamber was heavily instrumented to quantify organics (gas chromatography/mass spectrometry), inorganics by water extraction followed by ion chromatography, and select species by various individual commercially-available sensors. Evaluating new technologies for measuring carbon monoxide, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and other species of interest was a key objective of the test. Some of these sensors were located inside the glovebox near the fire source to avoid losses through the sampling lines; the rest were located just outside the glovebox. Instruments for smoke particle characterization included a Tapered Element Oscillating Microbalance Personal Dust Monitor (TEOM PDM) and a TSI Dust Trak DRX to measure particle mass concentration, a TSI PTrak for number concentration and a thermal precipitator for collection of particles for microscopic analysis. Materials studied included Nomex(R), M22759 wire insulation, granulated circuit board, polyvinyl chloride (PVC), Polytetrafluoroethylene (PTFE), Kapton(R), and mixtures of PTFE and Kapton(R). Furnace temperatures ranged from 340 to 640 C, focusing on the smoldering regime. Of particular interest in these tests was confirming burn repeatability and production of acid gases with different fuel mixture compositions, as well as the dependence of aerosol concentrations on temperature.

Combustion↗

Contrasting Stratospheric Smoke Mass and Lifetime From 2017 Canadian and 2019/2020 Australian Megafires: Global Simulations and Satellite Observations

Stratospheric injections of carbonaceous aerosols and combustion gases by extreme wildfires have become increasingly common. Recent “megafires,” particularly large and intense fires, delivered particulate burdens to the lower stratosphere comparable to those of moderate volcanic eruptions. The 2017 Canadian megafire generated four large Pyrocumulonimbi (pyroCbs), injecting up to ≈0.3 Tg of smoke in the lower stratosphere. Even more extreme, the 2019/2020 Australian event produced a pyroCb activity resulting in stratospheric smoke intrusions of ≈1 Tg. To understand their contrasting behavior, we present global climate simulations of the atmospheric response to these events, applying smoke burdens informed by remote observations. Model outcomes, compared to satellite data of smoke transport, reproduce reasonably well the initial plume rise, at 0.2–0.3 km/day, attaining heights of ≈20 km in Canada and above 30 km in Australia. Global dispersal of the plume occurs within about 3 weeks in both cases, consistent with observations. Smoke removal timescales, ≈5 months for the Canadian megafire, agree with remote measurements. During the Australian megafire, observations indicate stratospheric injections three times as large, and models predict comparatively longer smoke lifetimes, ≈16 months. After the latter event, atmospheric optical depths and radiative cooling achieved values close to those measured following the Pinatubo eruption. Sensitivity tests of model assumptions indicate, in accord with prior studies, that smoke burden, injection heights, and black carbon content can determine plume evolution and possible climate impacts. An empirical relation between peak heights of stratospheric plumes and lifetimes is derived that can help assess megafire impacts on the stratosphere, climate and the Earth system

54 ENVIRONMENTAL SCIENCES↗

Effects of a composite flame retardant system on the flame retardancy and mechanical performance of epoxy resin adhesive

Abstract A flame‐retarded epoxy resin (ER) adhesive with strong flame retardancy and adhesion performance was prepared. The coated ammonium polyphosphate (MFAPP), melamine (MEL), and organic montmorillonite (OMMT) were mixed to prepare a composite flame retardant. It was subsequently blended with a toughened ER thoroughly and then the mixture was cured with polyamide. The resultant ER adhesive thermosets achieved UL‐94 V‐0 rating during vertical burning test, and the limiting oxygen index value was as high as 31.6%. The shear strength of the ER adhesive was 27.9 MPa when 25 wt% MFAPP/MEL/OMMT was introduced. Compared with the pure adhesive, the flame retardant epoxy adhesive maintained outstanding adhesion performance because of the good compatibility between the composite flame retardant additives and the toughened ER adhesive. Cone calorimetry tests indicated that the release of heat and smoke were obviously declined with the incorporation of the composite flame retardant system in comparison to pure ER adhesive thermoset. The investigation of flame retardant mechanism revealed that the composite MFAPP/MEL/OMMT flame retardant system stimulated the generation of highly expanded, integral, and strong char layer and the formed char layer exerted superior insulation effect during combusiton. The present work provided an alternative approach to prepare flame retardant ER adhesive with the similar excellent adhesive performance.

Li, Sheng↗

Flame retardant polyphosphazenes

Six polyphosphazene compositions were prepared by reaction of three bis-tertiary phosphines with two phenyl-s-triazine derived diazides. All six polyphosphazenes produced were completely characterized, four of them were furthermore subjected to isothermal gravimetric analysis, smoke density measurements, flammability and oxidative thermal degradation testing. The results of the characterization studies indicate that only low molecular weight oligomers, possibly of a cyclic structure, were obtained in the polymerization reactions. Despite this, however, two of the materials showed no weight loss after 96 hr at 200 C, one did not autoignite at 500 C in air, and all four self extinguished when exposed to a flame as soon as contact between flame and resin was lost. The only toxic decomposition products to be concerned about were found to be hydrogen cyanide and benzene. Under the conditions employed it was proven, however, that the quantities of toxic products are greatly reduced if no ignition takes place, e.g., if thermal decomposition proceeds at a sufficiently low rate.

Paciorek, K. L.↗

Design and preliminary tests of a blade tip air mass injection system for vortex modification and possible noise reduction on a full-scale helicopter rotor

Full-scale tests were conducted on the Langley helicopter rotor test facility as part of a study to evaluate the effectiveness of a turbulent blade tip air mass injection system in alleviating the impulsive noise (blade slap) caused by blade-vortex interaction. Although blade-slap conditions could not be induced during these tests, qualitative results from flow visualization studies using smoke showed that the differential velocity between the jet velocity and the rotor tip speed was a primary parameter controlling the vortex modification.

Pegg, R. J.↗

The 737 aircraft flammability testing

The FAA requested approximately 20 component and full-scale tests in a 737 fuselage to provide validation data or indicate changes that need to be made to a fire math model (Dayton Aircraft Cabin Fire Model) developed for the FAA. Some preliminary tests were conducted to evaluate the adequacy of planned instrumentation. The objectives of the program were met in that it was verified that propagation of a fire could be determined from the sequential response of thermocouples located on a test specimen(such as a seat), and continuous weighing of the specimen during the test was accomplished. Two differenct techniques for measuring smoke density were found to be comparable.

Bricker, R. W.↗

Enclosure fire modeling

A fire characterization methodology is presented, which for the first time provides a unified analysis framework for the integration of all fire tests data on a common basis. Fire temperatures, smoke densities, toxic gas concentrations and heat fluxes to material properties, enclosure geometry, and ventilation factors are provided in this fire characterization approach. The fire characterization methodology was used to develop an enclosure fire hazards analysis procedure capable of predicting the probable course in fire prevention.

Coulbert, C. D.↗

Investigation of soot and carbon formation in small gas turbine combustors

An investigation of hardware configurations which attempt to minimize carbon and soot-production without sacrificing performance in small gas turbine combustors was conducted. Four fuel injectors, employing either airblast atomization, pressure atomization, or fuel vaporization techniques were combined with nozzle air swirlers and injector sheaths. Eight configurations were screened at sea-level takeoff and idle test conditions. Selected configurations were focused upon in an attempt to quantify the influence of combustor pressure, inlet temperature, primary zone operation, and combustor loading on soot and carbon formation. Cycle tests were also performed. It was found that smoke emission levels depended on the combustor fluid mechanics, the atomization quality of the injector and the fuel hydrogen content.

Rosfjord, T. J.↗

Exhaust emissions of a double annular combustor: Parametric study

A full scale double-annular ram-induction combustor designed for Mach 3.0 cruise operation was tested. Emissions of oxides of nitrogen, carbon monoxide, unburned hydrocarbons, and smoke were measured over a range of combustor operating variables including reference velocity, inlet air temperature and pressure, and exit average temperature. ASTM Jet-A fuel was used for these tests. An equation is provided relating oxides of nitrogen emissions as a function of the combustor, operating variables. A small effect of radial fuel staging on reducing exhaust emissions (which were originally quite low) is demonstrated.

Schultz, D. F.↗

Relationships between coronary heart disease risk factors and serum ionized calcium in Kennedy Space Center Cohort

Kennedy Space Center (KSC) employees are reported to be at high risk for coronary heart disease (CHD). Risk factors for CHD include high serum total cholesterol levels, low levels of high-density lipoprotein cholesterol (HDLC), elevated triglyceride, smoking, inactivity, high blood pressure, being male, and being older. Higher dietary and/or serum calcium Ca(++) may be related to a lower risk for CHD. Fifty men and 37 women participated. Subjects were tested in the morning after fasting 12 hours. Information relative to smoking and exercise habits was obtained; seated blood pressures were measured; and blood drawn. KCS men had higher risk values than KCS women as related to HDLC, triglycerides, systolic blood pressure, and diastolic blood pressure. Smoking and nonsmoking groups did not differ for other risk factors or for serum Ca(++) levels. Exercise and sedentary groups differed in total cholesterol and triglyceride levels. Serum Ca(++) levels were related to age, increasing with age in the sedentary group and decreasing in the exercisers, equally for men and women. It is concluded that these relationships may be significant to the risk of CHD and/or the risk of bone demineralization in an aging population.

Goodwin, Lisa Ann↗

Comparative Soot Diagnostics: Preliminary Results

The motivation for the Comparative Soot Diagnostics (CSD) experiment lies in the broad practical importance of understanding combustion generated particulate. Depending upon the circumstances, particulate matter can affect the durability and performance of combustion equipment, can be a pollutant, can be used to detect fires and, in the form of soot, can be the dominant source of radiant energy from flames. The nonbuoyant structure of most flames of practical interest makes understanding of soot processes in low gravity flames important to our ability to predict fire behavior on earth. These studies also have direct applications to fire safety in human-crew spacecraft, since smoke is the indicator used for automated detection in current spacecraft. In the earliest missions (Mercury, Gemini and Apollo), the crew quarters were so cramped that it was considered reasonable that the astronauts would rapidly detect any fire. The Skylab module, however, included approximately 20 UV-sensing fire detectors. The Space Shuttle has 9 particle-ionization smoke detectors in the mid-deck and flight deck and Spacelab has six additional particle-ionization smoke detectors. The designated detectors for the ISS are laser-diode, forward-scattering, smoke or particulate detectors. Current plans for the ISS call for two detectors in the open area of the module, and detectors in racks that have both cooling air flow and electrical power. Due to the complete absence of data concerning the nature of particulate and radiant emission from incipient and fully developed low-g fires, all three of these detector systems were designed based upon l-g test data and experience. As planned mission durations and complexity increase and the volume of spacecraft increases, the need for and importance of effective, crew-independent, fire detection grows significantly. To provide this level of protection, more knowledge is needed concerning low-gravity fire phenomena and, in particular, how they might be detected and suppressed. Prior to CSD, no combustion-generated particulate samples had been collected near the flame zone for well-developed microgravity flames. All of the extant data either came from drop tower tests and therefore only corresponded to the early stages of a fire or were collected far from the flame zone. The fuel sources in the drop tower tests were restricted to laminar gas-jet diffusion flames and very rapidly overheated wire insulation. The gas-jet tests indicated, through thermophoretic sampling, (2) that soot primaries and aggregates (groups of primary particles) in low-gravity may be significantly larger than those in normal gravity (1-g). This raises new scientific questions about soot processes as well as practical issues for particulate size sensitivity and detection alarm threshold levels used in on-orbit smoke detectors. Preliminary tests in the 2.2 second drop tower suggest that particulate generated by overheated wire insulation may be larger in low-g than in 1-g. Transmission Electron Microscope (TEM) grids downstream of the fire region in the Wire Insulation Flammability experiment as well as visual observation of long string-like aggregates, further confirm this suggestion. The combined impact of these limited results and theoretical predictions is that, as opposed to extrapolation from l-g data, direct knowledge of low-g combustion particulate is needed for more confident design of smoke detectors for spacecraft. This paper describes the operation and preliminary results of the CSD, a project conceived and developed at NASA Lewis Research Center. The CSD flight experiment was conducted in the Middeck Glovebox Facility (MGBX) on USMP-3. The project is support by NASA Headquarters Microgravity Science and Applications Division and Code Q. The results presented here are from the microgravity portion of the experiment, including the temporal response of the detectors and average sizes of the primary and aggregate particles captured on the thermophoretic probes.

Urban, David L.↗