102 records · Page 6

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Providing Housing, Food and Medical Support for 25,000 Katrina Evacuees with 12 Hours Notice: The Harris County Medical Support of the Superdome Evacuees

Hurricane Katrina was responsible for trapping 25,000 people in the New Orleans Superdome and isolating many others throughout Louisiana and Mississippi. The transport of these evacuees to the Reliant Park (Houston, Texas) used 500 buses each containing about 55 people. Processing the arriving evacuees included addressing their health status and medical needs as follows: an initial triage at disembarkation, a secondary triage in the Reliant Astrodome and Center, and definitive clinical care in the Reliant Arena "Katrina" Clinic. Baylor College of Medicine (BCM) physicians boarded buses and identified the sickest for emergency transport to Harris County Hospital District (HCHD) hospitals. BCM departments represented included pediatrics, family and community medicine, internal medicine, radiology, obstetrics and gynecology, orthopedics, surgery, and psychiatry. Astrodome and Center triage was managed by BCM physicians and staffed by HCHD Nurses and volunteers from Texas and beyond. The Reliant Astrodome, Center and Arena reached peak headcounts of 15,000,4500, and 2500, respectively Most evacuees visiting the triage sites in the Astrodome and Center were treated using "over-the-counter" medications with the remaining being transported to the "Katrina" clinic. The clinic was equipped with a lab, pharmacy, digital X-ray, and ultrasound machines in addition to electronic patient records created using 80 computer terminals. The Katrina clinic saw more than 15,000 patients during 15 days of operations (2,000 on the first full day), administered 10,000 tetanus shots, and filled thousands of prescriptions. At the peak of operations, the clinic saw 150 patients/hour with 25 physicians scheduled for each 12-hour shift. Approximately 900 people were transported to hospital emergency rooms. Within 3 weeks of arriving at the Reliant Park facilities, more than 90% of the families found permanent housing, enrolled children in schools, and found work. Using data obtained from manual and electronic medical records, this presentation will document the major milestones and lessons learned from this extraordinary project to help the Katrina evacuees.

Hamilton, Douglas↗

Ombuds Office 2023 Biennial Report

The Los Alamos National Laboratory (LANL) Ombuds Charter requires the Ombuds Office to issue a report every two years to the Laboratory Director. The prior Ombuds Biennial Report was published in July of 2021, celebrating 25 years of Ombuds history at the Lab. This 2023 report details office transitions and new initiatives over the past two years, along with our ongoing conflict resolution work of one-on-one discussions, classes, presentations, workshops, and facilitations. The Ombuds Office supports the mission of LANL in myriad ways. We champion the LANL culture statement of “ How we do work is as important as What we do,” and we reinforce LANL’s values of integrity, service, excellence, and teamwork. Accordingly, the mission of the Ombuds Office is to support employees in their work, enhance communication, mitigate conflict, and encourage a positive working environment. The Ombuds Office adheres to the International Ombuds Association’s (IOA) Standards of Practice and Code of Ethics (see Appendix). As such, the Ombuds Office is informal, confidential, impartial, and independent. We do not advocate for managers or employees. We don’t tell people what to do; we don’t give advice. All of our services are voluntary. LANL employees seek out the Ombuds Office as a neutral place where they can collect their thoughts, whether in person, on the phone, or online. We help individuals explore and navigate tough issues. Employees expand their understanding of their options, assess what is within their control, and decide what is in their best interest. The Ombuds Office promotes smart, professional conflict management. This report highlights the work of the Ombuds Office and provides a closer look at both quantitative and qualitative data, including anecdotal information and endorsements. It concludes with a discussion of further opportunities to expand the reach of the Ombuds Office to more LANL employees.

99 GENERAL AND MISCELLANEOUS↗

Progress in demonstrating the performance of Engineered Barriers for the disposal of HLW and SNF: lab studies and demonstration experiments - 20293

Disposal of high-level radioactive waste (HLW) and spent nuclear fuels (SNF) in a geological disposal facility requires a fundamental understanding of the degradation processes of materials used in its engineered barrier system (EBS) over very long timescales. Beyond the wasteform itself (i.e. the borosilicate glass for HLW or the fuel matrix and cladding for SNF), materials often employed in a disposal concept include metallic containers (typically copper and/or carbon steel) and clay-based buffer materials (typically bentonite). In this paper we explore key developments on the long-term evolution of materials employed for the immobilisation, isolation and containment of HLW and SNF in a geological disposal facility, including nuclear glasses, candidate container materials and clay buffers. Our discussion is based on the latest findings from both experimental studies and in-situ demonstration experiments. We present relevant findings from the long-term evolution of HLW glasses (UK composition), metallic materials for the containment system (envisaged in Switzerland, Sweden, Canada and other countries), and bentonite clays (envisaged in many national disposal programmes). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MAGESTIC: Magnetically Enabled Structures Using Interacting Coils

In our NIAC Phase I study, awarded September 2011, the MIT Space Systems Lab (MIT SSL) began investigating a new structural and mechanical technique aimed at reducing the mass and increasing the stowed-to-deployed ratio of spacecraft systems. This technique uses the magnetic fields from current passing through coils of high temperature superconductors (HTSs) to support spacecraft structures and deploy them to operational configurations from their positions as stowed inside a launch vehicle fairing. These electromagnetic coils are tethered or hinged together in such a way that their motion in some directions or around some axes is constrained, as in Figure 1. Our Phase II study,awarded in Fall 2012, continued this work on electromagnetic structures, with an added focus on developing a new thermal system, investigating additional, non-structural electromagnet functions, and creating a maturation roadmap and plan for addressing barriers to feasibility of the technology. We now call the project MAGESTIC, or Magnetically Enabled STructures using Interacting Coils.

Superconductors↗

Inspecta Technical Report

Sandia National Laboratories (SNL) has developed Inspecta (International Nuclear Safeguards Personal Examination and Containment Tracking Assistant), an AI-powered smart digital assistant (SDA) equipped with robotic capabilities. This innovative tool aims to enhance the effectiveness, efficiency, and safety of international nuclear safeguards inspections. Inspecta is designed to assist inspectors on-site by supporting or automating tasks that are often mundane, hazardous, or prone to errors. In 2021, the development team established the specifications for Inspecta by thoroughly analyzing International Atomic Energy Agency (IAEA) documents and consulting with former IAEA inspectors and subject matter experts. This process involved aligning in-field inspection tasks with existing commercial and open-source technologies, thereby creating a roadmap for the initial prototype of Inspecta and identifying areas requiring further research and development. From 2022 to 2025, the focus shifted to integrating a critical inspection activity—the examination of seals—into an early version of Inspecta. This phase has involved the development of both software and hardware capabilities essential for this task. This report outlines the advancements in Inspecta’s functionalities, particularly those that support the seal examination process.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Implications of Advanced Manufacturing in a Connected Economy Moving Towards a Smart, Sustainable, and Productive Economy

This report intends to provide a comprehensive overview of information and communications technologies (ICT), which play increasingly vital roles in the United States (U.S.) and global economies and continue to evolve rapidly as both technological capabilities and needs grow in tandem. To underscore the importance of the sector, the U.S. Congress recently passed a $\$$20–$\$$50 billion federal program Creating Helpful Incentives to Produce Semiconductors Act (CHIPS Act) to spur the competitiveness of the U.S. semiconductor industry and encourage U.S. investment, often complemented by state-level incentives (Kessler 2022).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Unsupervised Detection of SOC Spoofing in OCPP 2.0.1 EV Charging Communication Protocol Using One-Class SVM

The electric vehicles (EVs) market keeps growing globally; thus, it is critical to secure the EV charging communication protocols in order to guarantee reliable and fair charging operations among the customers. The Open Charge Point Protocol (OCPP) 2.0.1 supports the communication between the Electric Vehicle Supply Equipment (EVSE) and Charging Station Management Systems (CSMSs); therefore, it becomes vulnerable to several types of attacks, which aim to jeopardize smart charging, billing, and energy management. Specifically, OCPP 2.0.1 allows the self-reporting of the State of Charge (SOC) values, which makes it vulnerable to spoofing-based cyberattacks, which target manipulating the scheduling priorities, distorting the load forecasts, and extending the charging sessions in an unfair manner. In this paper, we try to address this type of attack by providing a comprehensive analysis of the SOC spoofing attacks and introducing a novel unsupervised detection framework based on the One-Class Support Vector Machine (OCSVM) algorithm. Specifically, two types of attack scenarios are analyzed (i.e., priority manipulation and session extension) by deriving engineered features that capture the nonlinear relationships under normal charging behavior. Detailed simulation-based results are derived by utilizing the DESL-EPFL Level 3 EV charging dataset. Our results demonstrate high F1-score and recall in identifying spoofed SOC values and that the proposed OCSVM model demonstrates superior performance compared to alternative clustering and deep-learning based detectors.

EV charging↗

Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

Schlegel, Todd T.↗

Scalable Unit Commitment with Security Constrained AC Power Flow via ADMM and Hybrid Modeling Strategies

This research introduces a more efficient way to optimize power grid operations, breaking the problem into manageable steps and using advanced mathematical techniques to speed up calculations. By incorporating smart heuristics, improved preprocessing, and contingency analysis, the approach allows operators to make better decisions faster. These innovations enhance our understanding of how to optimize energy generation, making it possible to anticipate failures before they happen, reduce system costs, and improve overall grid performance. Ultimately, this research helps bridge the gap between theoretical models and real-world applications, paving the way for a smarter, more resilient power grid. This research directly benefits the public by making electricity more affordable, reliable, and sustainable. By improving how power grids schedule and distribute electricity, the project helps energy providers reduce operational costs, which can lead to lower electricity prices for consumers. Additionally, the ability to predict and prevent power system failures enhances grid reliability, reducing the likelihood of blackouts that can disrupt homes, businesses, and critical infrastructure such as hospitals. From an environmental perspective, optimizing power generation reduces energy waste and lowers carbon emissions, contributing to cleaner air and a more sustainable energy system. Furthermore, with extreme weather events becoming more frequent, these advancements make the power grid more resilient, ensuring communities are better prepared for emergencies and natural disasters. By strengthening the nation's energy infrastructure, this research plays a crucial role in improving economic stability, public safety, and environmental sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modular Subsurface Sensors and Integrated Software for Advanced Subsurface Characterization and Monitoring using Unoccupied Vehicles

The advent and subsequent proliferation of autonomous airborne, waterborne, and groundbased vehicles (i.e., “drones”) promises to broadly transform the geosciences and associated industries, including fossil energy exploration and development, mineral resource exploration and development, water-resource management, and environmental remediation. For geophysical characterization and monitoring, the prospect of programming highly repeatable and low-cost drone missions for subsurface imaging will allow for deployments in hazardous and previously inaccessible areas. Coupled with autonomous workflows for data processing, management, and visualization, drone-based geophysical characterization and monitoring will enable unprecedented, real-time insight into diverse subsurface properties and processes of scientific and engineering importance. Toward this end, the objectives of this Lab Directed Research and Development (LDRD) project were to develop new (1) instrumentation for dronebased electromagnetic induction (EMI) geophysical imaging, including separated transmitter and receivers and associated electronics, (2) software for real-time data telemetry, processing, management, and visualization. Although EMI has been previously deployed using unoccupied aerial systems (UASs), these applications failed to capitalize on the game-changing capabilities of drone platforms. Whereas drone-based data acquisition allows for collection of rich, three-dimensional (3D) multi-offset/multi-angle configurations between transmitters and receivers, past efforts have relied on conventional instrumentation that was designed for ground-based data collection with the transmitter and a single receiver housed in the same unit; nor did these previous applications demonstrate real-time delivery of results to support rapid management decisions in the field. In this 1-year project, we (1) designed and constructed new lightweight independent transmitter and receiver antenna platforms that communicate with a laptop computer; (2) developed software to control data acquisition, manage/transfer data, and visualize data as its collected; and (3) demonstrated the operation of the new hardware and software systems in a ground-based field test. Our work entails major technological advances for EMI and established a foundation on which to build a new drone-based, real-time geophysical EMI imaging capability to support diverse challenges facing the nation.

47 OTHER INSTRUMENTATION↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗