Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Comparative Mineralogy, Microstructure and Compositional Trends in the Sub-Micron Size Fractions of Mare and Highland Lunar Soils

The morphology, mineralogy, chemical composition and optical properties of lunar soils show distinct correlations as a function of grain size and origin [1,2,3]. In the <20 m size fraction, there is an increased correlation between lunar surface properties observed through remote sensing techniques and those attributed to space weathering phenomenae [1,2]. Despite the establishment of recognizable trends in lunar grains <20 in size [1,2,3], the size fraction < 10 m is characterized as a collective population of grains without subdivision. This investigation focuses specifically on grains in the <1 m diameter size fraction for both highland and mare derived soils. The properties of these materials provide the focus for many aspects of lunar research including the nature of space weathering on surface properties, electrostatic grain transport [4,5] and dusty plasmas [5]. In this study, we have used analytical transmission and scanning transmission electron microscopy (S/TEM) to characterize the mineralogy type, microstructure and major element compositions of grains in this important size range in lunar soils.

Thompson, M. S.↗

Pneumatic System for Concentration of Micrometer-Size Lunar Soil

A report describes a size-sorting method to separate and concentrate micrometer- size dust from a broad size range of particles without using sieves, fluids, or other processes that may modify the composition or the surface properties of the dust. The system consists of four processing units connected in series by tubing. Samples of dry particulates such as lunar soil are introduced into the first unit, a fluidized bed. The flow of introduced nitrogen fluidizes the particulates and preferentially moves the finer grain sizes on to the next unit, a flat plate impactor, followed by a cyclone separator, followed by a Nuclepore polycarbonate filter to collect the dust. By varying the gas flow rate and the sizes of various orifices in the system, the size of the final and intermediate particles can be varied to provide the desired products. The dust can be collected from the filter. In addition, electron microscope grids can be placed on the Nuclepore filter for direct sampling followed by electron microscope characterization of the dust without further handling.

McKay, David↗

Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot

The optical extinction of a laser due to scattering of particles is a well-known phenomenon. In a laboratory environment, this physical principle is known as the Beer-Lambert law, and is often used to measure the concentration of scattering particles in a fluid or gas. This method has been experimentally shown to be a usable means to measure the dust density from a rocket plume interaction with the lunar surface. Using the same principles and experimental arrangement, this technique can be applied to hydrometeor size distributions, and for launch-pad operations, specifically as a passive hail detection and measurement system. Calibration of a hail monitoring system is a difficult process. In the past, it has required comparison to another means of measuring hydrometeor size and density. Using a technique recently developed for estimating the density of surface dust dispersed during a rocket landing, measuring the extinction of a laser passing through hail (or dust in the rocket case) yields an estimate of the second moment of the particle cloud, and hydrometeor size distribution in the terrestrial meteorological case. With the exception of disdrometers, instruments that measure rain and hail fall make indirect measurements of the drop-size distribution. Instruments that scatter microwaves off of hydrometeors, such as the WSR-88D (Weather Surveillance Radar 88 Doppler), vertical wind profilers, and microwave disdrometers, measure the sixth moment of the drop size distribution (DSD). By projecting a laser onto a target, changes in brightness of the laser spot against the target background during rain and hail yield a measurement of the DSD's second moment by way of the Beer-Lambert law. In order to detect the laser attenuation within the 8-bit resolution of most camera image arrays, a minimum path length is required. Depending on the intensity of the hail fall rate for moderate to heavy rainfall, a laser path length of 100 m is sufficient to measure variations in optical extinction using a digital camera. For hail fall only, the laser path may be shorter because of greater scattering due to the properties of hailstones versus raindrops. A photodetector may replace the camera in automated installations. Laser-based rain and hail measurement systems are available, but they are based on measuring the interruption of a thin laser beam, thus counting individual hydrometeors. These systems are true disdrometers since they also measure size and velocity. The method reported here is a simple method, requiring far less processing, but it is not a disdrometer.

Lane, John↗

Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Khoshti, Ajay↗

Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Koshti, Ajay M.↗

An Ergonomic Evaluation of the Extravehicular Mobility Unit (EMU) Space Suit Hard Upper Torso (HUT) Size Effect on Metabolic, Mobility, and Strength Performance

The objective of this project was to assess the performance differences between a nominally sized Extravehicular Mobility Unit (EMU) space suit and a nominal +1 (plus) sized EMU. Method: This study evaluated suit size conditions by using metabolic cost, arm mobility, and arm strength as performance metrics. Results: Differences between the suit sizes were found only in shoulder extension strength being 15.8% greater for the plus size. Discussion: While this study was able to identify motions and activities that were considered to be practically or statistically different, it does not signify that use of a plus sized suit should be prohibited. Further testing would be required that either pertained to a particular mission critical task or better simulates a microgravity environment that the EMU suit was designed to work in.

Reid, Christopher↗

Imaging Systems for Size Measurements of Debrisat Fragments

The overall objective of the DebriSat project is to provide data to update existing standard spacecraft breakup models. One of the key sets of parameters used in these models is the physical dimensions of the fragments (i.e., length, average-cross sectional area, and volume). For the DebriSat project, only fragments with at least one dimension greater than 2 mm are collected and processed. Additionally, a significant portion of the fragments recovered from the impact test are needle-like and/or flat plate-like fragments where their heights are almost negligible in comparison to their other dimensions. As a result, two fragment size categories were defined: 2D objects and 3D objects. While measurement systems are commercially available, factors such as measurement rates, system adaptability, size characterization limitations and equipment costs presented significant challenges to the project and a decision was made to develop our own size characterization systems. The size characterization systems consist of two automated image systems, one referred to as the 3D imaging system and the other as the 2D imaging system. Which imaging system to use depends on the classification of the fragment being measured. Both imaging systems utilize point-and-shoot cameras for object image acquisition and create representative point clouds of the fragments. The 3D imaging system utilizes a space-carving algorithm to generate a 3D point cloud, while the 2D imaging system utilizes an edge detection algorithm to generate a 2D point cloud. From the point clouds, the three largest orthogonal dimensions are determined using a convex hull algorithm. For 3D objects, in addition to the three largest orthogonal dimensions, the volume is computed via an alpha-shape algorithm applied to the point clouds. The average cross-sectional area is also computed for 3D objects. Both imaging systems have automated size measurements (image acquisition and image processing) driven by the need to quickly and accurately measure tens of thousands of debris fragments. Moreover, the automated size measurement reduces potential fragment damage/mishandling and ability for accuracy and repeatability. As the fragment characterization progressed, it became evident that the imaging systems had to be revised. For example, an additional view was added to the 2D imaging system to capture the height of the 2D object. This paper presents the DebriSat project's imaging systems and calculation techniques in detail; from design and development to maturation. The experiences and challenges are also shared.

Shiotani, B.↗

Retrievals of Cloud Droplet Size from the Research Scanning Polarimeter Data: Validation Using In Situ Measurements

We present comparisons of cloud droplet size distributions (DSDs) retrieved from the research scanning polarimeter (RSP) data with correlative in situ measurements made during the North Atlantic Aerosols and Marine Ecosystems Study (NAAMES). The airborne portion of this field experiment was based out of St. John's airport, Newfoundland, Canada with the focus of this paper being on the deployment in May - June 2016. RSP was onboard the NASA C-130 aircraft together with an array of in situ and other remote sensing instrumentation. The RSP is an along-track scanner measuring the polarized and total reflectance in 9 spectral channels. Its uniquely high angular resolution allows for characterization of liquid water droplet sizes using the rainbow structure observed in the polarized reflectance over the scattering angle range from 135 to 165.degrees The rainbow is dominated by single scattering of light by cloud droplets, so its structure is characteristic specifically of the droplet sizes at cloud top (within unit optical depth into the cloud, equivalent to approximately 50m). A parametric fitting algorithm applied to the polarized reflectance provides retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, the Rainbow Fourier Transform (RFT), which allows us to retrieve the droplet size distribution itself. The latter is important in the case of clouds with complex microphysical structure, or multiple layers of cloud, which result in multi-modal DSDs. During NAAMES the aircraft performed a number of flight patterns specifically designed for comparisons between remote sensing retrievals and in situ measurements. These patterns consisted of two flight segments above the same straight ground track. One of these segments was flown above clouds allowing for remote sensing measurements, while the other was near the cloud top where cloud droplets were sampled. We compare the DSDs retrieved from the RSP data with in situ measurements made by the Cloud Droplet Probe (CDP). The comparisons generally show good agreement (better than 1 micron for effective radius and in most cases better than 0.02 for effective variance) with deviations explainable by the position of the aircraft within the cloud, or by the presence of additional cloud layers between the cloud being sampled by the in situ instrumentation and the altitude of the remote sensing segment. In the latter case, the multi-modal DSDs retrieved from the RSP data were consistent with the multi-layer cloud structures observed in the correlative High Spectral Resolution Lidar (HSRL) profiles. The results of these comparisons provide a rare validation of polarimetric droplet size retrieval techniques, demonstrating their accuracy and robustness and the potential of satellite data of this kind on a global scale.

Remote Sensing↗

The Effects of Different Footprint Sizes and Cloud Algorithms on the Top-Of-Atmosphere Radiative Flux Calculation from the Clouds and Earth’s Radiant Energy System (CERES) Instrument on Suomi National Polar-Orbiting Partnership (NPP)

Only one Clouds and Earth’s Radiant Energy System (CERES) instrument is onboard the Suomi National Polar-orbiting Partnership (NPP) and it has been placed in cross-track mode since launch; it is thus not possible to construct a set of angular distribution models (ADMs) specific for CERES on NPP. Edition 4 Aqua ADMs are used for flux inversions for NPP CERES measurements. However, the footprint size of NPP CERES is greater than that of Aqua CERES, as the altitude of the NPP orbit is higher than that of the Aqua orbit. Furthermore, cloud retrievals from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Moderate Resolution Imaging Spectroradiometer (MODIS), which are the imagers sharing the spacecraft with NPP CERES and Aqua CERES, are also different. To quantify the flux uncertainties due to the footprint size difference between Aqua CERES and NPP CERES, and due to both the footprint size difference and cloud property difference, a simulation is designed using the MODIS pixel-level data, which are convolved with the Aqua CERES and NPP CERES point spread functions (PSFs) into their respective footprints. The simulation is designed to isolate the effects of footprint size and cloud property differences on flux uncertainty from calibration and orbital differences between NPP CERES and Aqua CERES. The footprint size difference between Aqua CERES and NPP CERES introduces instantaneous flux uncertainties in monthly gridded NPP CERES measurements of less than 4.0 W/sq. m for SW (shortwave) and less than 1.0 W/sq. m for both daytime and nighttime LW (longwave). The global monthly mean instantaneous SW flux from simulated NPP CERES has a low bias of 0.4 W/sq. m when compared to simulated Aqua CERES, and the root-mean-square (RMS) error is 2.2 W/sq. m between them; the biases of daytime and night- time LW flux are close to zero with RMS errors of 0.8 and 0.2 W/sq. m. These uncertainties are within the uncertainties of CERES ADMs. When both footprint size and cloud property (cloud fraction and optical depth) differences are considered, the uncertainties of monthly gridded NPP CERES SW flux can be up to 20 W/sq. m in the Arctic regions where cloud optical depth retrievals from VIIRS differ significantly from MODIS. The global monthly mean instantaneous SW flux from simulated NPP CERES has a high bias of 1.1 W/sq. m and the RMS error increases to 5.2 W/sq. m. LW flux shows less sensitivity to cloud property differences than SW flux, with uncertainties of about 2 W/sq. m in the monthly gridded LW flux, and the RMS errors of global monthly mean daytime and nighttime fluxes increase only slightly. These results highlight the importance of consistent cloud retrieval algorithms to maintain the accuracy and stability of the CERES climate data record.

Su, Wenying↗

Impacts of aerosol size-dependent below-cloud scavenging on tropospheric aerosol in the NASA GEOS model

Cloud scavenging is the major sink for a suite of tropospheric aerosols, and thus largely affects the global distribution and lifetime of aerosols as well as the formation of clouds. Simplified model parameterizations of cloud scavenging of aerosols substantially contribute to large uncertainties in the simulated aerosol burdens, spatial distributions, lifetimes, as well as aerosol radiative forcing. Here we evaluate the wet scavenging scheme in the current NASA GEOS model, develop more physically-based parameterizations of below-cloud scavenging, and assess the impacts of the new scavenging parameterizations on the GEOS simulations of aerosols. The current below-cloud scavenging (BCS; washout) scheme uses a first-order removal with a constant scavenging coefficient. We replaced the current scheme with a size-dependent parameterization of Croft et al.(Atmos. Chem. Phys., 2009; hereafter referred to as C09). The C09 BCS parameterizations calculate aerosol below-cloud scavenging coefficients based on a size-dependent collision efficiency between aerosol particles and raindrops (or snow crystals). A look-up table of compiled collision efficiencies provides values for sixty aerosol sizes and nine rain flux rates. Snow-aerosol collision efficiencies are a function of the sixty aerosol sizes only. We assume a log-normal size distribution for aerosols (bulk) in GOCART. The collision efficiencies are then calculated online using a bilinear interpolation from the look-up table for the given aerosol sizes and precipitation flux rates in the model.

aerosols↗

An Electron Backscatter Diffraction (EBSD)-Based Automated Tool for Ceramic Capacitor Grain Size Analysis

Ceramic capacitors continue to be recurring problem parts for NASA, despite best efforts to screen out potential defects and failures through environmental and electrical testing and nondestructive inspection techniques such as acoustic microscopy. The physical properties of ceramic capacitors necessitates thin dielectric layers capable of withstanding significant electric fields. Any defects in those ceramic layers can result in reduced insulation resistance failure modes including short circuit failures, so the quality and consistency of the dielectric material is critical. The size of the individual ceramic grains in the dielectric material is a critical parameter. However, judging “grain size” is not so simple—in a single capacitor there can be wide variation in grain sizes observed. It is theorized that by studying the grain size distributions of “known good” and “known bad” lots of capacitors, some conclusions could be drawn that would allow us to better predict to the reliability of future lots based on grain size distributions. The initial goal of this effort was to find or develop an automated tool that could inspect a capacitor and return grain size distribution results.

Robert Hodson↗

Advanced Pressure Garment Space Suit Sizing Considerations

Fitting a space suit to a person could be considered an art form. Establishing a repeatable fitcheck process to accommodate the full anthropometric range of test subjects for a single suit design is a critical process to be able to prove suit functionality. Suited test subjects can have different preferences on how they fit inside a suit, and different suited test environments can lead to differences in certain suit sizing accommodations. Throughout this paper, the process of achieving an acceptable suit fit for test subjects will be discussed, along with sizing considerations for changes in suit design and test environments. Lessons learned from the Exploration Extravehicular Mobility Unit (xEMU) will be used to describe specific examples, along with key takeaways from additional NASA prototype mobility space suits. The suit fitcheck process starts with utilizing the anthropometric measurements of a test subject to evaluate their relation to the dimensions of space suit hardware in creating a predicted suit sizing configuration. From here, subjective comments and test team observations drive iterations to the suit sizing configuration to culminate in an acceptable suit fit for performance of further test evaluations. Understanding the relation of subjective comments to their impact on altering suit sizing is critical in establishing an acceptable suit fit.

spacesuit↗

Advanced Space Suit Sizing Considerations

Fitting a space suit to a person could be considered an art form. Establishing a repeatable fitcheck process to accommodate the full anthropometric range of test subjects for a single suit design is a critical process to be able to prove suit functionality. Suited test subjects can have different preferences on how they fit inside a suit, and different suited test environments can lead to differences in certain suit sizing accommodations. Throughout this paper, the process of achieving an acceptable suit fit for test subjects will be discussed, along with sizing considerations for changes in suit design and test environments. Lessons learned from the Exploration Extravehicular Mobility Unit (xEMU) will be used to describe specific examples, along with key takeaways from additional NASA prototype mobility space suits. The suit fitcheck process starts with utilizing the anthropometric measurements of a test subject to evaluate their relation to the dimensions of space suit hardware in creating a predicted suit sizing configuration. From here, subjective comments and test team observations drive iterations to the suit sizing configuration to culminate in an acceptable suit fit for performance of further test evaluations. Understanding the relation of subjective comments to their impact on altering suit sizing is critical in establishing an acceptable suit fit.

spacesuit↗

Relative size perception at a distance is best at eye level

Relative size judgments were collected for two objects at 30.5 m and 23.8 from the observer in order to assess how performance depends on the relationship between the size of the objects and the eye level of the observer. In three experiments in an indoor hallway and in one experiment outdoors, accuracy was higher for objects in the neighborhood of eye level. We consider these results in the light of two hypotheses. One proposes that observers localize the horizon as a reference for judging relative size, and the other proposes that observers perceive the general neighborhood of the horizon and then employ a height-in-visual-field heuristic. The finding that relative size judgments are best around the horizon implies that information that is independent of distance perception is used in perceiving size.

NASA Center ARC↗

The role of retinal versus perceived size in the effects of pitched displays on visually perceived eye level

Visually perceived eye level (VPEL) was measured while subjects viewed two vertical lines which were either upright or pitched about the horizontal axis. In separate conditions, the display consisted of a relatively large pair of lines viewed at a distance of 1 m, or a display scaled to one third the dimensions and viewed at a distance of either 1 m or 33.3 cm. The small display viewed at 33.3 cm produced a retinal image the same size as that of the large display at 1 m. Pitch of all three displays top-toward and top-away from the observer caused upward and downward VPEL shifts, respectively. These effects were highly similar for the large display and the small display viewed at 33.3 cm (ie equal retinal size), but were significantly smaller for the small display viewed at 1 m. In a second experiment, perceived size of the three displays was measured and found to be highly accurate. The results of the two experiments indicate that the effect of optical pitch on VPEL depends on the retinal image size of stimuli rather than on perceived size.

NASA Center ARC↗

Retrievals of Cloud Droplet Size from the RSP Data: Validation Using in Situ Measurements

We present comparisons of cloud droplet size distributions retrieved from the Research Scanning Polarimeter (RSP) data with correlative in situ measurements made during the North Atlantic Aerosols and Marine Ecosystems Study (NAAMES). This field experiment was based at St. Johns airport, Newfoundland, Canada with the latest deployment in May - June 2016. RSP was onboard the NASA C-130 aircraft together with an array of in situ and other remote sensing instrumentation. The RSP is an along-track scanner measuring polarized and total reflectances in9 spectral channels. Its unique high angular resolution allows for characterization of liquid water droplet size using the rainbow structure observed in the polarized reflectances in the scattering angle range between 135 and 165 degrees. A parametric fitting algorithm applied to the polarized reflectances provides retrievals of the droplet effective radius and variance assuming a prescribed size distribution shape (gamma distribution). In addition to this, we use a non-parametric method, Rainbow Fourier Transform (RFT), which allows us to retrieve the droplet size distribution (DSD) itself. The latter is important in the case of clouds with complex structure, which results in multi-modal DSDs. During NAAMES the aircraft performed a number of flight patterns specifically designed for comparison of remote sensing retrievals and in situ measurements. These patterns consisted of two flight segments above the same straight ground track. One of these segments was flown above clouds allowing for remote sensing measurements, while the other was at the cloud top where cloud droplets were sampled. We compare the DSDs retrieved from the RSP data with in situ measurements made by the Cloud Droplet Probe (CDP). The comparisons show generally good agreement with deviations explainable by the position of the aircraft within cloud and by presence of additional cloud layers in RSP view that do not contribute to the in situ DSDs. In the latter case the distributions retrieved from the RSP data were consistent with the multi-layer cloud structures observed in the correlative High Spectral Resolution Lidar (HSRL) profiles. The comparison results provide a rare validation of polarimetric droplet size retrieval techniques, which can be used for analysis of satellite data on global scale.

cloud droplets↗

Grain Size-Dependent Crystal Plasticity Constitutive Model for Polycrystal Materials

A new method to introduce grain size-dependence in classical crystal plasticity constitutive model is developed by considering the resistance to dislocation motion in the grain boundary influence region as equivalent to that of a work hardening. A general framework for the size-dependent constitutive model is derived by implementing this method on a core and mantle model. The work hardening, equivalent to grain boundary effect, is realized by introducing a fictitious, pre-existing, plastic strain grain boundary influence region (mantle) following the principles of classical crystal plasticity. This fictitious plastic strain, in effect, increases the yield strength and decreases the initial hardening coefficient of the grain. With the thickness of grain boundary influence region and the distribution of introduced plastic strain remaining the same, the grain boundary effect increased as the grain size becomes smaller. A simplified model that considers the grain boundary effect on a grain average sense is also developed under this general framework. Implementation of this general framework to the specific cases of crystal plasticity constitutive models is demonstrated by considering the case of power law flow rule and hyperbolic-secant hardening rule. Finally, the grain size-dependent constitutive model is validated by comparing the predicted stress-strain behavior of polycrystal samples with different average grain sizes under uniaxial loading with the experimental results.

Grain Size↗

Structural Sizing of a 50-m-Tall Thermoplastic Composite Solar Array Truss Tower Structure for the Lunar South Pole

At the lunar south pole, solar arrays elevated by truss towers are exposed to near continuous sunlight since the sun remains near the horizon. Recent studies suggest that tower heights on the order of 50 m are needed to meet the power requirements to support a sustained lunar presence. While eventually towers may be constructed using materials sourced in-situ, initially structural elements will likely be brought from the Earth, deployed, and assembled. Thermoplastic composites offer the benefit of high specific stiffness and strength properties along with welding for assembly joints, and therefore represent a promising material system for this application. The focus of this paper is on the structural sizing of such towers. A set of expressions based on beam theory are presented for preliminary sizing of the truss tower structure for strength and buckling. The loading condition that drives sizing is base excitation resulting from moonquakes. A point design, developed through finite element analysis, verifies the analytical sizing routine and shows the importance of joints. The results show a viable point design and highlight the factors most significant in the structural sizing.

Thermoplastic composites↗