A dual cone-beam CT system for image guided radiotherapy: Initial performance characterization

Purpose: The purpose of this study is to evaluate the performance of a recently developed benchtop dual cone-beam computed tomography (CBCT) system with two orthogonally placed tube/detector sets. Methods: The benchtop dual CBCT system consists of two orthogonally placed 40 Multiplication-Sign 30 cm flat-panel detectors and two conventional x-ray tubes with two individual high-voltage generators sharing the same rotational axis. The x-ray source to detector distance is 150 cm and x-ray source to rotational axis distance is 100 cm for both subsystems. The objects are scanned through 200 Degree-Sign of rotation. The dual CBCT system utilized 110 Degree-Sign of projection data from one detector and 90 Degree-Sign from the other while the two individual single CBCTs utilized 200 Degree-Sign data from each detector. The system performance was characterized in terms of uniformity, contrast, spatial resolution, noise power spectrum, and CT number linearity. The uniformities, within the axial slice and along the longitudinal direction, and noise power spectrum were assessed by scanning a water bucket; the contrast and CT number linearity were measured using the Catphan phantom; and the spatial resolution was evaluated using a tungsten wire phantom. A skull phantom and a ham were also scanned to provide qualitative evaluation of high- and low-contrast resolution. Each measurement was compared between dual and single CBCT systems. Results: Compared to single CBCT, the dual CBCT presented: (1) a decrease in uniformity by 1.9% in axial view and 1.1% in the longitudinal view, as averaged for four energies (80, 100, 125, and 150 kVp); (2) comparable or slightly better contrast (0{approx}25 HU) for low-contrast objects and comparable contrast for high-contrast objects; (3) comparable spatial resolution; (4) comparable CT number linearity with R{sup 2}{>=} 0.99 for all four tested energies; (5) lower noise power spectrum in magnitude. Dual CBCT images of the skull phantom and the ham demonstrated both high-contrast resolution and good soft-tissue contrast. Conclusions: The performance of a benchtop dual CBCT imaging system has been characterized and is comparable to that of a single CBCT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PUZZLES OF THE INTERPLANETARY MAGNETIC FIELD IN THE INNER HELIOSPHERE

Deviations of the interplanetary magnetic field (IMF) from Parker's model are frequently observed in the heliosphere at different distances r from the Sun. Usually, it is supposed that the IMF behavior corresponds to Parker's model overall, but there is some turbulent component that impacts and disrupts the full picture of the IMF spatial and temporal distribution. However, the analysis of multi-spacecraft in-ecliptic IMF measurements from 0.29 AU to 5 AU shows that the IMF radial evolution is rather far from expected. The radial IMF component decreases with the adiabatic power index (|B{sub r} | {proportional_to} r {sup -5/3}), the tangential component |B{sub r}| {proportional_to} r {sup -1}, and the IMF strength B {proportional_to} r {sup -1.4}. This means that the IMF is not completely frozen in the solar wind. It is possible that turbulent processes in the inner heliosphere significantly influence the IMF expansion. This is confirmed by the analysis of the B{sub r} distribution's radial evolution. B{sub r} has a well-known bimodal histogram only at 0.7-2.0 AU. The bimodality effect gradually disappears from 1 AU to 4 AU, and B{sub r} becomes quasi-normally distributed at 3-4 AU (which is a sign of rapid vanishing of the stable sector structure with heliocentric distance). We consider a quasi-continuous magnetic reconnection, occurring both at the heliospheric current sheet and at local current sheets inside the IMF sectors, to be a key process responsible for the solar wind turbulization with heliocentric distance as well as for the breakdown of the ''frozen-in IMF'' law.

79 ASTRONOMY AND ASTROPHYSICS↗

FAST MOTIONS OF GALAXIES IN THE COMA I CLOUD: A CASE OF DARK ATTRACTOR?

We note that nearby galaxies having high negative peculiar velocities are distributed over the sky very inhomogeneously. A part of this anisotropy is caused by the 'Local Velocity Anomaly', i.e., by the bulk motion of nearby galaxies away from the Local Void. However, half of the fast-flying objects reside within a small region known as the Coma I cloud. According to Makarov and Karachentsev, this complex contains 8 groups, 5 triplets, 10 pairs, and 83 single galaxies with a total mass of 4.7 Multiplication-Sign 10{sup 13} M{sub Sun }. We use 122 galaxies in the Coma I region with known distances and radial velocities V{sub LG} < 3000 km s{sup -1} to draw the Hubble relation for them. The Hubble diagram shows a Z-shaped effect of infall with an amplitude of +200 km s{sup -1} on the nearby side and -700 km s{sup -1} on the back side. This phenomenon can be understood as the galaxy infall toward a dark attractor with a mass of {approx}2 Multiplication-Sign 10{sup 14} M{sub Sun} situated at a distance of 15 Mpc from us. The existence of a large void between the Coma and Virgo clusters also probably affects the Hubble flow around the Coma I.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CHANGE OF THE ORBITAL PERIODS ACROSS ERUPTIONS AND THE EJECTED MASS FOR RECURRENT NOVAE CI AQUILAE AND U SCORPII

I report on the cumulative results from a program started 24 years ago designed to measure the orbital period change of recurrent novae (RNe) across an eruption. The goal is to use the orbital period change to measure the mass ejected during each eruption as the key part of trying to measure whether the RNe white dwarfs are gaining or losing mass over an entire eruption cycle, and hence whether they can be progenitors for Type Ia supernovae. This program has now been completed for two eclipsing RNe: CI Aquilae (CI Aql) across its eruption in 2000 and U Scorpii (U Sco) across its eruption in 1999. For CI Aql, I present 78 eclipse times from 1991 to 2009 (including four during the tail of the 2000 eruption) plus two eclipses from 1926 and 1935. For U Sco, I present 67 eclipse times, including 46 times during quiescence from 1989 to 2009, plus 21 eclipse times in the tails of the 1945, 1999, and 2010 eruptions. The eclipse times during the tails of eruptions are systematically and substantially shifted with respect to the ephemerides from the eclipses in quiescence, with this being caused by shifts of the center of light during the eruption. These eclipse times are plotted on an O - C diagram and fitted to models with a steady period change ( P-dot ) between eruptions (caused by, for example, conservative mass transfer) plus an abrupt period change ({Delta}P) at the time of eruption. The primary uncertainty arises from the correlation between {Delta}P with P-dot , such that a more negative P-dot makes for a more positive {Delta}P. For CI Aql, the best fit is {Delta}P = -3.7{sup +9.2}{sub -7.3} Multiplication-Sign 10{sup -7}. For U Sco, the best fit is {Delta}P = (+ 43 {+-} 69) Multiplication-Sign 10{sup -7} days. These period changes can directly give a dynamical measure of the mass ejected (M{sub ejecta}) during each eruption with negligible sensitivity to the stellar masses and no uncertainty from distances. For CI Aql, the 1{sigma} upper limit is M{sub ejecta} < 10 Multiplication-Sign 10{sup -7} M{sub Sun }. For U Sco, I derive M{sub ejecta} = (43 {+-} 67) Multiplication-Sign 10{sup -7} M{sub Sun }.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of fast neutrons by bubble detectors

Neutron bubble detectors have been studied using Am-Be and D-D neuron sources, which give limited energy information. The Bubble Detector Spectrometer (BDS) have six different energy thresholds ranging from 10 KeV to 10 Mev. The number of bubbles obtained in each measurement is related to the dose (standardized response R) equivalent neutrons through sensitivity (b / {mu}Sv) and also with the neutron flux (neutrons per unit area) through a relationship that provided by the manufacturer. Bubble detectors were used with six different answers (0.11 b/ {mu}Sv, 0093 b/{mu}Sv, 0.14 b/{mu}Sv, 0.17 b/{mu}Sv, 0051 b/{mu}Sv). To test the response of the detectors (BDS) radiate a set of six of them with different energy threshold, with a source of Am-Be, placing them at a distance of one meter from it for a few minutes. Also, exposed to dense plasma focus Fuego Nuevo II (FN-II FPD) of ICN-UNAM, apparatus which produces fusion plasma, generating neutrons by nuclear reactions of neutrons whose energy emitting is 2.45 MeV. In this case the detectors were placed at a distance of 50 cm from the pinch at 90 Degree-Sign this was done for a certain number of shots. In both cases, the standard response is reported (Dose in {mu}Sv) for each of the six detectors representing an energy range, this response is given by the expression R{sub i}= B{sub i} / S{sub i} where B{sub i} is the number of bubbles formed in each and the detector sensitivity (S{sub i}) is given for each detector in (b / {mu}Sv). Also, reported for both cases, the detected neutron flux (n cm{sup -2}), by a given ratio and the response involves both standardized R, as the average cross section sigma. The results obtained have been compared with the spectrum of Am-Be source. From these measurements it can be concluded that with a combination of bubble detectors, with different responses is possible to measure the equivalent dose in a range of 10 to 100 {mu}Sv fields mixed neutron and gamma, and pulsed generated fusion devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{beta} PICTORIS AND AB DORADUS MOVING GROUPS: LIKELY NEW LOW-MASS MEMBERS

We present results from our continuing program to identify new, low-mass, members of the nearby young moving groups (NYMGs) using a proper motion selection algorithm and various observational techniques. We have three goals: (1) to provide high priority targets for exoplanet searches by direct imaging, (2) to complete the census of the membership in the NYMGs down to {approx}0.1 M{sub sun}, and thus (3) provide a well-characterized sample of nearby (median distances at least twice as close as the Taurus and Ophiuchus star-forming regions), young (8-50 Myr) stars for detailed study of their physical properties and multiplicity. Our program proceeds as follows: we apply the selection algorithm to a proper motion catalog where initial selection cuts of candidate members are based on the mean motion of known NYMG members and the proper motions and photometric distances of the candidates. NYMG membership is investigated further using possible signs of youth, including H{alpha} emission and X-ray flux, and then verified through radial velocity measurements. We identify TYC 1766-1431-1 (M3), TYC 1208-468-1 and 2 (K3), TYC 7558-655-1 (K5), and PM I04439+3723W and E (M3) as likely members of the {beta} Pictoris moving group (BPMG) and TYC 1741-2117-1N and S (K7), TYC 1752-63-1 (K7), TYC 523-573-1 (K7), and TYC 4943-192-1 (M0) as likely members of the AB Doradus moving group (ABDMG). We also rule out the membership of several BPMG and ABDMG candidates. To date our program has identified 16 new NYMG members of spectral type K3 or later.

79 ASTRONOMY AND ASTROPHYSICS↗

TWO NEW TESTS OF THE METALLICITY SENSITIVITY OF THE CEPHEID PERIOD-LUMINOSITY RELATION (THE LEAVITT LAW)

We undertake a new test of the metallicity sensitivity of the Leavitt Law for classical Cepheids. We derive an empirical calibration of the apparent luminosities of Cepheids as measured from the optical through the mid-infrared (0.45-8.0 {mu}m) as a function of spectroscopic [Fe/H] abundances of individual Cepheids in the Large Magellanic Cloud (LMC) from Romaniello et al. The cumulative trend over the entire wavelength range shows a nearly monotonic behavior. The sense of the trend is consistent with differential line blanketing in the optical, leading to stars of high metallicity being fainter in the optical. This is followed by a reversal in the trend at longer wavelengths, with the crossover occurring near the K band at about 2.2 {mu}m, consistent with a subsequent redistribution of energy resulting in a mild brightening of Cepheids (with increased metallicity) at mid-infrared wavelengths. This conclusion agrees with that of Romaniello et al. based on a differential comparison of the mean V- and K-band Leavitt Laws for the Galaxy, Small Magellanic Cloud, and LMC, but is opposite in sign to most other empirical tests of the sensitivity of Cepheid distances to mean [O/H] H II region abundances. We also search for a correlation of Cepheid host-galaxy metallicity with deviations of the galaxy's Cepheid distance from that predicted from a pure Hubble flow. Based on Cepheid distances to 26 nearby galaxies in the local flow, only a very weak signal is detected giving {delta}{mu}{sub o} = -0.17({+-} 0.31)([O/H] - 8.80) - 0.21({+-} 0.10). This is in agreement with previous determinations, but statistically inconclusive.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY EMISSION FROM THE WOLF-RAYET BUBBLE S 308

The Wolf-Rayet (WR) bubble S 308 around the WR star HD 50896 is one of the only two WR bubbles known to possess X-ray emission. We present XMM-Newton observations of three fields of this WR bubble that, in conjunction with an existing observation of its northwest quadrant, map most of the nebula. The X-ray emission from S 308 displays a limb-brightened morphology, with a central cavity {approx}22' in size and a shell thickness of {approx}8'. This X-ray shell is confined by the optical shell of ionized material. The spectrum is dominated by the He-like triplets of N VI at 0.43 keV and O VII at 0.57 keV, and declines toward high energies, with a faint tail up to 1 keV. This spectrum can be described by a two-temperature optically thin plasma emission model (T{sub 1} {approx} 1.1 Multiplication-Sign 10{sup 6} K, T{sub 2} {approx} 13 Multiplication-Sign 10{sup 6} K), with a total X-ray luminosity {approx}2 Multiplication-Sign 10{sup 33} erg s{sup -1} at the assumed distance of 1.5 kpc.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY OBSERVATIONS OF THE SUPERNOVA REMNANT CTB 87 (G74.9+1.2): AN EVOLVED PULSAR WIND NEBULA

Pulsar wind nebulae (PWNe) studies with the Chandra X-Ray Observatory have opened a new window to address the physics of pulsar winds, zoom on their interaction with their hosting supernova remnant (SNR) and interstellar medium, and identify their powering engines. We here present a new 70 ks, plus an archived 18 ks, Chandra ACIS observation of the SNR CTB 87 (G74.9+1.2), classified as a PWN with unusual radio properties and poorly studied in X-rays. We find that the peak of the X-ray emission is clearly offset from the peak of the radio emission by {approx}100'' and located at the southeastern edge of the radio nebula. We detect a point source-the putative pulsar-at the peak of the X-ray emission and study its spectrum separately from the PWN. This new point source, CXOU J201609.2+371110, is surrounded by a compact nebula displaying a torus-like structure and possibly a jet. A more extended diffuse nebula is offset from the radio nebula, extending from the point source to the northwest for {approx}250''. The spectra of the point source, compact nebula, and extended diffuse nebula are all well described by a power-law model with a photon index of 1.1 (0.7-1.6), 1.2 (0.9-1.4), and 1.7 (1.5-1.8), respectively, for a column density N{sub H} = 1.38 (1.21-1.57) Multiplication-Sign 10{sup 22} cm{sup -2} (90% confidence). The total X-ray luminosity of the source is {approx}1.6 Multiplication-Sign 10{sup 34} erg s{sup -1} at an assumed distance of 6.1 kpc, with {approx}2% and 6% contribution from the point source and compact nebula, respectively. The observed properties suggest that CTB 87 is an evolved ({approx}5-28 kyr) PWN, with the extended radio emission likely a ''relic'' PWN, as in Vela-X and G327.1-1.1. To date, however, there is no evidence for thermal X-ray emission from this SNR, and the SNR shell is still missing, suggesting expansion into a low-density medium (n{sub 0} < 0.2 D{sup -1/2}{sub 6.1} cm{sup -3}), likely caused by a stellar wind bubble blown by the progenitor star.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC{sup Registered-Sign }, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic{sup TM} EBT and EBT2) in PMMA and in a Solid Water{sup Registered-Sign} phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon{sup Registered-Sign} and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any 'squircle-shaped' field. When one side of the rectangular field is held constant and the second side is reduced, both R{sub 50} and R{sub max} move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 Multiplication-Sign 4.4 cm{sup 2} square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 Multiplication-Sign 9 cm{sup 2} 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%). Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The non-existence of the Oort cometary shell

The procedures adopted as theory for a shell of comets are shown to be invalid. Any plot of numbers of long-period comets against 1/a will automatically exhibit a peak at small values of this parameter, and cannot be inverted to demonstrate a high volume-density of aphelia in space. The positions of actual aphelion-points show no sign of any concentration at any range. Further, the aphelion-distance undergoes large almost random changes owing to planetary perturbations at each return, and present values can yield no indication of original positions. A recent attempt to save the shell-theory by making use solely of comets with large perihelion-distance is shown to rest on exactly the same errors as have done all the earlier presentations. The plain conclusions emerge that the shell-theory is devoid of any support by facts, and that the alleged shell of comets is non-existent.

Lyttleton, R. A.↗

Characterization of imaging performance in differential phase contrast CT compared with the conventional CT: Spectrum of noise equivalent quanta NEQ(k)

Purpose: Differential phase contrast CT (DPC-CT) is emerging as a new technology to improve the contrast sensitivity of conventional attenuation-based CT. The noise equivalent quanta as a function over spatial frequency, i.e., the spectrum of noise equivalent quanta NEQ(k), is a decisive indicator of the signal and noise transfer properties of an imaging system. In this work, we derive the functional form of NEQ(k) in DPC-CT. Via system modeling, analysis, and computer simulation, we evaluate and verify the derived NEQ(k) and compare it with that of the conventional attenuation-based CT. Methods: The DPC-CT is implemented with x-ray tube and gratings. The x-ray propagation and data acquisition are modeled and simulated through Fresnel and Fourier analysis. A monochromatic x-ray source (30 keV) is assumed to exclude any system imperfection and interference caused by scatter and beam hardening, while a 360 Degree-Sign full scan is carried out in data acquisition to avoid any weighting scheme that may disrupt noise randomness. Adequate upsampling is implemented to simulate the x-ray beam's propagation through the gratings G{sub 1} and G{sub 2} with periods 8 and 4 {mu}m, respectively, while the intergrating distance is 193.6 mm (1/16 of the Talbot distance). The dimensions of the detector cell for data acquisition are 32 Multiplication-Sign 32, 64 Multiplication-Sign 64, 96 Multiplication-Sign 96, and 128 Multiplication-Sign 128 {mu}m{sup 2}, respectively, corresponding to a 40.96 Multiplication-Sign 40.96 mm{sup 2} field of view in data acquisition. An air phantom is employed to obtain the noise power spectrum NPS(k), spectrum of noise equivalent quanta NEQ(k), and detective quantum efficiency DQE(k). A cylindrical water phantom at 5.1 mm diameter and complex refraction coefficient n= 1 -{delta}+i{beta}= 1 -2.5604 Multiplication-Sign 10{sup -7}+i1.2353 Multiplication-Sign 10{sup -10} is placed in air to measure the edge transfer function, line spread function and then modulation transfer function MTF(k), of both DPC-CT and the conventional attenuation-based CT. The x-ray flux is set at 5 Multiplication-Sign 10{sup 6} photon/cm{sup 2} per projection and observes the Poisson distribution, which is consistent with that of a micro-CT for preclinical applications. Approximately 360 regions, each at 128 Multiplication-Sign 128 matrix, are used to calculate the NPS(k) via 2D Fourier transform, in which adequate zero padding is carried out to avoid aliasing in noise. Results: The preliminary data show that the DPC-CT possesses a signal transfer property [MTF(k)] comparable to that of the conventional attenuation-based CT. Meanwhile, though there exists a radical difference in their noise power spectrum NPS(k) (trait 1/|k| in DPC-CT but |k| in the conventional attenuation-based CT) the NEQ(k) and DQE(k) of DPC-CT and the conventional attenuation-based CT are in principle identical. Conclusions: Under the framework of ideal observer study, the joint signal and noise transfer property NEQ(k) and detective quantum efficiency DQE(k) of DPC-CT are essentially the same as those of the conventional attenuation-based CT. The findings reported in this paper may provide insightful guidelines on the research, development, and performance optimization of DPC-CT for extensive preclinical and clinical applications in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE EXTENSIVE AGE GRADIENT OF THE CARINA DWARF GALAXY

The evolution of small systems such as dwarf spheroidal galaxies (dSphs) is likely to have been a balance between external environmental effects and internal processes within their own relatively shallow potential wells. Assessing how strong such environmental interactions may have been is therefore an important element in understanding the baryonic evolution of dSphs and their derived dark matter distribution. Here we present results from a wide-area CTIO/MOSAIC II photometric survey of the Carina dSph, reaching down to about two magnitudes below the oldest main-sequence turnoff (MSTO). This data set enables us to trace the structure of Carina in detail out to very large distances from its center, and as a function of stellar age. We observe the presence of an extended structure made up primarily of ancient MSTO stars, at distances between 25' and 60' from Carina's center, confirming results in the literature that Carina extends well beyond its nominal tidal radius. The large number statistics of our survey reveals features such as isophote twists and tails that were undetected in other previous, shallower surveys. This is the first time that such unambiguous signs of tidal disruption have been found in a Milky Way 'classical' dwarf other than Sagittarius. We also demonstrate the presence of a negative age gradient in Carina directly from its MSTOs, and trace it out to very large distances from the galaxy center. The signs of interaction with the Milky Way make it unclear whether the age gradient was already in place before Carina underwent tidal disruption.

79 ASTRONOMY AND ASTROPHYSICS↗

THE STELLAR METALLICITY DISTRIBUTION FUNCTION OF THE GALACTIC HALO FROM SDSS PHOTOMETRY

We explore the stellar metallicity distribution function of the Galactic halo based on SDSS ugriz photometry. A set of stellar isochrones is calibrated using observations of several star clusters and validated by comparisons with medium-resolution spectroscopic values over a wide range of metal abundance. We estimate distances and metallicities for individual main-sequence stars in the multiply scanned SDSS Stripe 82, at heliocentric distances in the range 5-8 kpc and |b| > 35 Degree-Sign , and find that the in situ photometric metallicity distribution has a shape that matches that of the kinematically selected local halo stars from Ryan and Norris. We also examine independent kinematic information from proper-motion measurements for high Galactic latitude stars in our sample. We find that stars with retrograde rotation in the rest frame of the Galaxy are generally more metal poor than those exhibiting prograde rotation, which is consistent with earlier arguments by Carollo et al. that the halo system comprises at least two spatially overlapping components with differing metallicity, kinematics, and spatial distributions. The observed photometric metallicity distribution and that of Ryan and Norris can be described by a simple chemical evolution model by Hartwick (or by a single Gaussian distribution); however, the suggestive metallicity-kinematic correlation contradicts the basic assumption in this model that the Milky Way halo consists primarily of a single stellar population. When the observed metallicity distribution is deconvolved using two Gaussian components with peaks at [Fe/H] Almost-Equal-To -1.7 and -2.3, the metal-poor component accounts for {approx}20%-35% of the entire halo population in this distance range.

79 ASTRONOMY AND ASTROPHYSICS↗

THE INTERPLANETARY NETWORK SUPPLEMENT TO THE FERMI GBM CATALOG OF COSMIC GAMMA-RAY BURSTS

We present Interplanetary Network (IPN) data for the gamma-ray bursts in the first Fermi Gamma-Ray Burst Monitor (GBM) catalog. Of the 491 bursts in that catalog, covering 2008 July 12 to 2010 July 11, 427 were observed by at least one other instrument in the nine-spacecraft IPN. Of the 427, the localizations of 149 could be improved by arrival time analysis (or {sup t}riangulation{sup )}. For any given burst observed by the GBM and one other distant spacecraft, triangulation gives an annulus of possible arrival directions whose half-width varies between about 0.'4 and 32 Degree-Sign , depending on the intensity, time history, and arrival direction of the burst, as well as the distance between the spacecraft. We find that the IPN localizations intersect the 1{sigma} GBM error circles in only 52% of the cases, if no systematic uncertainty is assumed for the latter. If a 6 Degree-Sign systematic uncertainty is assumed and added in quadrature, the two localization samples agree about 87% of the time, as would be expected. If we then multiply the resulting error radii by a factor of three, the two samples agree in slightly over 98% of the cases, providing a good estimate of the GBM 3{sigma} error radius. The IPN 3{sigma} error boxes have areas between about 1 arcmin{sup 2} and 110 deg{sup 2}, and are, on the average, a factor of 180 smaller than the corresponding GBM localizations. We identify two bursts in the IPN/GBM sample that did not appear in the GBM catalog. In one case, the GBM triggered on a terrestrial gamma flash, and in the other, its origin was given as ''uncertain''. We also discuss the sensitivity and calibration of the IPN.

79 ASTRONOMY AND ASTROPHYSICS↗

A mathematical discussion concerning the performance of multilayer perceptron-type artificial neural networks through use of orthogonal bipolar vectors

This work proposes the use of orthogonal bipolar vectors (OBV) as targets for multilayer perceptron (MLP) Artificial neural networks pertaining to the pattern recognition field. Implications involving this proposal are supported by a proper mathematical discussion. This study shows that the use of OBV as targets improves the class identification performance of MLP networks for pattern recognition with more than two classes when compared to the widely used conventional target bipolar vector (CBV). In addition to the overall performance improvement, it is possible to obtain high recognition rates with fewer training epochs, while keeping a feasible generalization with other data. This behavior is related to the Euclidean distance of the points in the output space, which is much higher in the case of OBVs. Therefore, with a greater distance between the points in the output space, the MLP network becomes less prone to associate trained outputs with incorrect targets. The mathematical discussion in this study is based on the backpropagation training algorithm. In addition to the mathematical discussion, results from experiments with real data are presented. These results follow those obtained by mathematical derivations. Real data sets used in the experiments are available from: (a) the Semeion Handwritten Digit of Machine Learning Repository, international repository; (b) Iris Image Database from the Chinese Academy of Sciences—CASIA; (c) Australian Sign Language, signs of Machine Learning Repository, international repository. Experiments were conducted to measure the mean Euclidean distance between the MLP network output subjected to a given input pattern and outputs related to other pattern classifications. Experimental results show that MLP networks trained with OBVs were able to ensure a Euclidean distance between the output and incorrect targets greater than MLP networks trained with CBVs (by up to 4 times for handwritten, by up to 12 times for iris images and by up to 10 times for Auslan signs language). As such, the adoption of OBVs as target vectors for MLPs reduces the computational effort for training the network.

97 MATHEMATICS AND COMPUTING↗

Gaussian-type light bullet solutions of the (3+1)-dimensional Schrödinger equation with cubic and power-law nonlinearities in PT-symmetric potentials

Two kinds of Gaussian-type light bullet (LB) solutions of the (3+1)-dimensional Schrödinger equation with cubic and power-law nonlinearities in PT-symmetric potentials are analytically obtained. The phase switches, powers and transverse power-flow densities of these solutions in homogeneous media are studied. The linear stability analysis of these LB solutions and the direct numerical simulation indicate that LB solutions are stable below some thresholds for the imaginary part of PT-symmetric potentials in the defocusing cubic and focusing power-law nonlinear medium, while they are always unstable for all parameters in other media. Moreover, the broadened and compressed behaviors of LBs in the exponential periodic amplification system and diffraction decreasing system are discussed. Results indicate that LB is more stable for the sign-changing nonlinearity in the exponential periodic amplification system than for the non-sign-changing nonlinearity in the diffraction decreasing system at the same propagation distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters

The purpose of this work was to determine the relative sensitivity of skin QED diodes, optically stimulated luminescent dosimeters (OSLDs) (microStar Trade-Mark-Sign DOT, Landauer), and LiF thermoluminescent dosimeters (TLDs) as a function of distance from a photon beam field edge when applied to measure dose at out-of-field points. These detectors have been used to estimate radiation dose to patients' implantable cardioverter-defibrillators (ICDs) located outside the treatment field. The ICDs have a thin outer case made of 0.4- to 0.6-mm-thick titanium ({approx}2.4-mm tissue equivalent). A 5-mm bolus, being the equivalent depth of the devices under the patient's skin, was placed over the ICDs. Response per unit absorbed dose-to-water was measured for each of the dosimeters with and without bolus on the beam central axis (CAX) and at a distance up to 20 cm from the CAX. Doses were measured with an ionization chamber at various depths for 6- and 15-MV x-rays on a Varian Clinac-iX linear accelerator. Relative sensitivity of the detectors was determined as the ratio of the sensitivity at each off-axis distance to that at the CAX. The detector sensitivity as a function of the distance from the field edge changed by {+-} 3% (1-11%) for LiF TLD-700, decreased by 10% (5-21%) for OSLD, and increased by 16% (11-19%) for the skin QED diode (Sun Nuclear Corp.) at the equivalent depth of 5 mm for 6- or 15-MV photon energies. Our results showed that the use of bolus with proper thickness (i.e., {approx}d{sub max} of the photon energy) on the top of the ICD would reduce the scattered dose to a lower level. Dosimeters should be calibrated out-of-field and preferably with bolus equal in thickness to the depth of interest. This can be readily performed in clinic.

61 RADIATION PROTECTION AND DOSIMETRY↗