Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dependence of direct detection signals on the WIMP velocity distribution

The signals expected in WIMP direct detection experiments depend on the ultra-local dark matter distribution. Observations probe the local density, circular speed and escape speed, while simulations find velocity distributions that deviate significantly from the standard Maxwellian distribution. We calculate the energy, time and direction dependence of the event rate for a range of velocity distributions motivated by recent observations and simulations, and also investigate the uncertainty in the determination of WIMP parameters. The dominant uncertainties are the systematic error in the local circular speed and whether or not the MW has a high density dark disc. In both cases there are substantial changes in the mean differential event rate and the annual modulation signal, and hence exclusion limits and determinations of the WIMP mass. The uncertainty in the shape of the halo velocity distribution is less important, however it leads to a ∼ 5% systematic error in the WIMP mass. The detailed direction dependence of the event rate is sensitive to the velocity distribution. However the numbers of events required to detect anisotropy and confirm the median recoil direction do not change substantially.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-Phenomenology Explosion Monitoring (Multi-PEM). Signal Detection. Research to target smaller sources for tomorrow’s missions

This a guide on how to detect and identify explosions from various sources. For example, nuclear explosions produce acoustic, optical, and EMP outputs. Each signal can be buried in noise, but fusing detection statistics from seismic, acoustic, and electromagnetic signals results in clear detection otherwise unobtainable.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Application of LSI to signal detection: The deltic DFPCC

The development of the DELTIC DFPCC serial mode signal processor is discussed. The processor is designed to detect in the presence of background noise a signal coded into the zero crossings of the waveform. The unique features of the DELTIC DFPCC include versatility in handling a variety of signals and relative simplicity in implementation. A theoretical performance model is presented which predicts the expected value of the output signal as a function of the input signal to noise ratio. Experimental results obtained with the prototype system, which was breadboarded with LSI, MSI and SSI components, are given. The device was compared with other LSI schemes for signal processing and it was concluded that the DELTIC DFPCC is simpler and in some cases more versatile than other systems. With established LSI technology, low frequency systems applicable to sonar and similar problems are feasible.

Gassaway, J. D.↗

SU-G-IeP2-08: Investigation On Signal Detectability in Volumetric Cone Beam CT Images with Anatomical Background

Purpose: To investigate the slice direction dependent detectability in cone beam CT images with anatomical background. Methods: We generated 3D anatomical background images using breast anatomy model. To generate 3D breast anatomy, we filtered 3D Gaussian noise with a square root of 1/f{sup 3}, and then assigned the attenuation coefficient of glandular (0.8cm{sup −1}) and adipose (0.46 cm{sup −1}) tissues based on voxel values. Projections were acquired by forward projection, and quantum noise was added to the projection data. The projection data were reconstructed by FDK algorithm. We compared the detectability of a 3 mm spherical signal in the image reconstructed from four different backprojection Methods: Hanning weighted ramp filter with linear interpolation (RECON1), Hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON3), and ramp filter with Fourier interpolation (RECON4), respectively. We computed task SNR of the spherical signal in transverse and longitudinal planes using channelized Hotelling observer with Laguerre-Gauss channels. Results: Transverse plane has similar task SNR values for different backprojection methods, while longitudinal plane has a maximum task SNR value in RECON1. For all backprojection methods, longitudinal plane has higher task SNR than transverse plane. Conclusion: In this work, we investigated detectability for different slice direction in cone beam CT images with anatomical background. Longitudinal plane has a higher task SNR than transverse plane, and backprojection with hanning weighted ramp filter with linear interpolation method (i.e., RECON1) produced the highest task SNR among four different backprojection methods. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Programs(IITP-2015-R0346-15-1008) supervised by the IITP (Institute for Information & Communications Technology Promotion), Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the MSIP (2015R1C1A1A01052268) and framework of international cooperation program managed by NRF (NRF-2015K2A1A2067635).

60 APPLIED LIFE SCIENCES↗

Detecting Signals of Large–Scale Climate Phenomena in Discharge and Nutrient Loads in the Mississippi–Atchafalaya River Basin

Agricultural runoff from the Mississippi–Atchafalaya River Basin delivers nitrogen (N) and phosphorus (P) to the Gulf of Mexico, causing hypoxia, and climate drives interannual variation in nutrient loads. Climate phenomena such as El Niño–Southern Oscillation may influence nutrient export through effects on river flow, nutrient uptake, or biogeochemical transformation, but landscape variation at smaller spatial scales can mask climate signals in load or discharge time series within large river networks. Here, we used multivariate autoregressive state–space modeling to investigate climate signals in the long–term record (1979–2014) of discharge, N, P, and SiO 2 loads at three nested spatial scales within the Mississippi–Atchafalaya River Basin. We detected significant signals of El Niño–Southern Oscillation and land–surface temperature anomalies in N loads but not discharge, SiO 2 , or P, suggesting that large–scale climate phenomena contribute to interannual variation in nutrient loads through biogeochemical mechanisms beyond simple discharge–load relationships.

54 ENVIRONMENTAL SCIENCES↗

The Sensitive Infrared Signal Detection by Sum Frequency Generation

An up-conversion device that converts 2.05-micron light to 700 nm signal by sum frequency generation using a periodically poled lithium niobate crystal is demonstrated. The achieved 92% up-conversion efficiency paves the path to detect extremely weak 2.05-micron signal with well established silicon avalanche photodiode detector for sensitive lidar applications.

Wong, Teh-Hwa↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

Subaperture clutter filter with CFAR signal detection

The various technologies presented herein relate to the determination of whether a received signal comprising radar clutter further comprises a communication signal. The communication signal can comprise of a preamble, a data symbol, communication data, etc. A first portion of the radar clutter is analyzed to determine a radar signature of the first portion of the radar clutter. A second portion of the radar clutter can be extracted based on the radar signature of the first portion. Following extraction, any residual signal can be analyzed to retrieve preamble data, etc. The received signal can be based upon a linear frequency modulation (e.g., a chirp modulation) whereby the chirp frequency can be determined and the frequency of transmission of the communication signal can be based accordingly thereon. The duration and/or bandwidth of the communication signal can be a portion of the duration and/or the bandwidth of the radar clutter.

42 ENGINEERING↗

Three-Gorge Reservoir: A 'Controlled Experiment' for Calibration/Validation of Time-Variable Gravity Signals Detected from Space

With the advances of measurements, modern space geodesy has become a new type of remote sensing for the Earth dynamics, especially for mass transports in the geophysical fluids on large spatial scales. A case in point is the space gravity mission GRACE (Gravity Recovery And Climate Experiment) which has been in orbit collecting gravity data since early 2002. The data promise to be able to detect changes of water mass equivalent to sub-cm thickness on spatial scale of several hundred km every month or so. China s Three-Gorge Reservoir has already started the process of water impoundment in phases. By 2009,40 km3 of water will be stored behind one of the world s highest dams and spanning a section of middle Yangtze River about 600 km in length. For the GRACE observations, the Three-Gorge Reservoir would represent a geophysical controlled experiment , one that offers a unique opportunity to do detailed geophysical studies. -- Assuming a complete documentation of the water level and history of the water impoundment process and aided with a continual monitoring of the lithospheric loading response (such as in area gravity and deformation), one has at hand basically a classical forwardinverse modeling problem of surface loading, where the input and certain output are known. The invisible portion of the impounded water, i.e. underground storage, poses either added values as an observable or a complication as an unknown to be modeled. Wang (2000) has studied the possible loading effects on a local scale; we here aim for larger spatial scales upwards from several hundred km, with emphasis on the time-variable gravity signals that can be detected by GRACE and follow-on missions. Results using the Green s function approach on the PREM elastic Earth model indicate the geoid height variations reaching several millimeters on wavelengths of about a thousand kilometers. The corresponding vertical deformations have amplitude of a few centimeters. In terms of long-wavelength spherical harmonics, the induced geoid height variations are very close to the accuracy of GRACE- recoverable gravity field, while the low-degree (2 to 5) harmonics should be detectable. With a large regional time-variable gravity signal, the Three-Gorge experiment can serve as a useful calibration/verification for GRACE (including the elastic loading effects), and future gravity missions (especially for visco-elastic yielding as well as underground water variations).

Chao, Benjamin F.↗

Optimization of combined delayed neutron and differential die-away prompt neutron signal detection for characterization of spent nuclear fuel assemblies

The Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy (DOE) has funded multiple laboratories and universities to develop a means to accurately quantify the Plutonium (Pu) mass in spent nuclear fuel assemblies and ways to also detect potential diversion of fuel pins. Delayed Neutron (DN) counting provides a signature somewhat more sensitive to {sup 235}U than Pu while Differential Die-Away (DDA) is complementary in that it has greater sensitivity to Pu. The two methods can, with care, be combined into a single instrument which also provides passive neutron information. Individually the techniques cannot robustly quantify the Pu content but coupled together the information content in the signatures enables Pu quantification separate to the total fissile content. The challenge of merging DN and DDA, prompt neutron (PN) signal, capabilities in the same design is the focus of this paper. Other possibilities also suggest themselves, such as a direct measurement of the reactivity (multiplication) by either the boost in signal obtained during the active interrogation itself or by the extension of the die-away profile. In an early study, conceptual designs have been modeled using a neutron detector comprising fission chambers or 3He proportional counters and a {approx}14 MeV neutron Deuterium-Tritium (DT) generator as the interrogation source. Modeling was performed using the radiation transport code Monte Carlo N-Particles eXtended (MCNPX). Building on this foundation, the present paper quantifies the capability of a new design using an array of {sup 3}He detectors together with fission chambers to optimize both DN and PN detections and active characterization, respectively. This new design was created in order to minimize fission in {sup 238}U (a nuisance DN emitter), to use a realistic neutron generator, to reduce the cost and to achieve near spatial interrogation and detection of the DN and PN, important for detection of diversion, all within the constraints of a single practical instrument. Both DN and PN detections are active techniques using the signal from the most prominent fissile isotopes of spent nuclear fuel that respond the best to a slow neutron interrogation, {sup 235}U, {sup 239}U and {sup 241}PU. The performance is characterized against a library of 64 assemblies and 40 diversion scenarios at different burnup (BU), cooling-time (CT) and initial enrichment (IE) in fresh water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A signal detection strategy for the SETI All Sky Survey

A source detection strategy for the SETI All Sky Survey is described. The method is designed to detect continuous wave (or very narrowband) sources transitting an antenna beam. The short-time spectra of the received signal are accumulated, and candidate extraterrestrial sources are recognized by the recognized by the presence of narrowband power exceeding a threshold function. The threshold function is derived using a Neyman-pearson hypothesis test.

Lawton, W.↗

Loop-induced dark matter direct detection signals from γ-ray lines

Improved limits as well as tentative claims for dark matter annihilation into γ-ray lines have been presented recently. We study the direct detection cross section induced from dark matter annihilation into two photons in a model-independent fashion, assuming no additional couplings between dark matter and nuclei. We find a striking non-standard recoil spectrum due to different destructively interfering contributions to the dark matter nucleus scattering cross section. While in the case of s-wave annihilation the current sensitivity of direct detection experiments is insufficient to compete with indirect detection searches, for p-wave annihilation the constraints from direct searches are comparable. This will allow to test dark matter scenarios with p-wave annihilation that predict a large di-photon annihilation cross section in the next generation of experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINING THE DISTRIBUTION OF DARK MATTER IN THE INNER GALAXY WITH AN INDIRECT DETECTION SIGNAL: THE CASE OF A TENTATIVE 130 GeV {gamma}-RAY LINE

Dark matter distribution in the very inner region of our Galaxy is still debated. In N-body simulations, a cuspy dark matter halo density profile is favored. Several dissipative baryonic processes, however, are found to be able to significantly flatten dark matter distribution, and a cored dark matter halo density profile is possible. Baryons dominate the gravitational potential in the inner Galaxy, hence a direct constraint on the abundance of dark matter particles is rather challenging. Recently, a few groups have identified a tentative 130 GeV line signal in the Galactic center, which could be interpreted as the signal of dark matter annihilation. Using current 130 GeV line data and adopting the generalized Navarro-Frenk-White profile of the dark matter halo-local dark matter density {rho}{sub 0} = 0.4 GeV cm{sup -3} and r{sub s} = 20 kpc-we obtain a 95% confidence level lower (upper) limit on the inner slope of dark matter density distribution, {alpha} = 1.06 (the cross section of dark matter annihilation into {gamma}-rays ({sigma}v){sub {chi}{chi}{sub {yields}{sub {gamma}{gamma}}}} = 1.3 Multiplication-Sign 10{sup -27} cm{sup 3} s{sup -1}). Such a slope is consistent with the results of some N-body simulations and, if the signal is due to dark matter, suggests that baryonic processes may be unimportant.

79 ASTRONOMY AND ASTROPHYSICS↗

Signal detection in l/f noise of SQUID magnetometers

It is shown that the variance on the SQUID power spectrum in the l/f low frequency region is well behaved, i.e., any small frequency band may be treated as white noise in standard power spectrum estimation theory. Specifically a calibration signal is examined at 0.017 Hz with an equivalent energy referred to the SQUID input coil of 1 times 10 to the -30th J and a digitally recorded and analyzed record of 140 hr duration obtained an optimum S/N better than 400. The results are in good agreement with theory. In addition no deviation from the l/f dependence of the noise energy spectrum is seen down to frequencies below 10 to the -5th Hz. A commercially available SQUID and electronics system were used.

Cabrera, B.↗

Coherence specific signal detection via chiral pump-probe spectroscopy

We examine transient circular dichroism (TRCD) spectroscopy as a technique to investigate signatures of exciton coherence dynamics under the influence of structured vibrational environments. We consider a pump-probe configuration with a linearly polarized pump and a circularly polarized probe, with a variable angle θ between the two directions of propagation. In our theoretical formalism the signal is decomposed in chiral and achiral doorway and window functions. Using this formalism, we show that the chiral doorway component, which beats during the population time, can be isolated by comparing signals with different values of θ. As in the majority of time-resolved pump-probe spectroscopy, the overall TRCD response shows signatures of both excited and ground state dynamics. However, we demonstrate that the chiral doorway function has only a weak ground state contribution, which can generally be neglected if an impulsive pump pulse is used. These findings suggest that the pump-probe configuration of optical TRCD in the impulsive limit has the potential to unambiguously probe quantum coherence beating in the excited state. We present numerical results for theoretical signals in an example dimer system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertex potentials evoked during auditory signal detection - Relation to decision criteria

Vertex potentials were recorded from eight subjects performing in an auditory threshold detection task with rating scale responses. The amplitudes and latencies of both the N1 and the late positive (P3) components were found to vary systematically with the criterion level of the decision. These changes in the waveshape of the N1 component were comparable to those produced by varying the signal intensity in a passive condition, but the late positive component in the active task was not similarly related to the passively evoked P2 component. It was suggested that the N1 and P3 components represent distinctive aspects of the decision process, with N1 signifying the quantity of signal information received and P3 reflecting the certainty of the decision based upon that information.

Squires, K. C.↗