Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Short circuiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

OPET Hardware (Open PV Electrical Tool Hardware) [SWR-25-42]

OPET (Open-source Photovoltaic Electrical Tool) is used for performance measurements of solar photovoltaic (PV) devices in the field under natural sunlight or in the lab under artificial light. Its primary use is in research and development of solar cells and modules, specifically in reliability and durability research of PV devices. Some features and functions include: -IV curve measurements with linear or cosine distributed measurement points -PV device active loading at open circuit voltage (Voc), short circuit current (Isc) and maximum power point (Pmp) -Bias power supply to overcome series resistance in contact wires for Isc measurements and loading -PV voltage input in five ranges from 1V to 100V -PV current input ranges -Low current version, six current ranges from 1.1mA to 340mA -High current version, six current ranges from 50mA to 15A -IO ports for I2C and SPI temperature sensor Arduino extension boards -Integrated fan control This repository contains everything relating to the hardware of the OPET device. If you are looking for the firmware or software repositories, links are below: https://github.com/NREL/opet-firmware https://github.com/NREL/opet-control

McDanold, Byron [National Renewable Energy Laborat↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems: Preprint

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.

dc-dc control↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Unlocking the Electrochemical–Mechanical Coupling Behaviors of Dendrite Growth and Crack Propagation in All-Solid-State Batteries

Dendrite growth and crack propagation are two major hurdles on the road towards the large-scale commercialization of lithium metal all-solid-state batteries (ASSBs). Due to the high multiphysics coupled nature of the underlying dendrite growth mechanism, understanding it has been difficult. Herein, for the first time, an electrochemical-mechanical model is established that directly couples dendrite growth and crack propagation from a physics-based perspective at the cell level. Results reveal that overpotential-driven stress propels a crack to penetrate through the solid electrolyte, creating vacancies for dendrite growth, leading to the short circuit of the battery. Thus, high lithiation/charging rate and low conductivity of electrolytes can accelerate the electrochemical failure of the battery. It is further discovered that Young's modulus E LLZO of the electrolyte has competing contributions to the fracture and dendrite growth; specifically, when E LLZO = 40-100 GPa, the short circuit is triggered early. A larger toughness value hinders the crack propagation and mitigates the Li dendrite growth. The developed multiphysics model provides an in-depth understanding of the coupling of crack propagation and dendrite growth within ASSBs and an insightful mechanistic design guidance map for robust and safe ASSB cells.

25 ENERGY STORAGE↗

Mitigating Voltage Instability in the Saudi Grid for a Decarbonized, Fully Solar Power System

Lately, solar photovoltaic (PV) has received significant interest due to its economic and environmental benefits. As the integration of renewable energy sources (RES) increases into existing power grids, challenges such as the decrease in short circuit ratio (SCR) are introduced. Here, this paper investigates a case study of the Saudi power grid, examining the voltage stability as the grid transitions from traditional power generation to 100% penetration of solar PV gradually. Moreover, the paper explores the relationship between the increase in solar penetration and the potential effects on the short circuit MVA (SCMVA), which could significantly impact the overall SCR of the system. To meet the North American Electric Reliability Corporation (NERC) recommendation of maintaining SCR at a particular level, synchronous condensers (SC)s were integrated into the grid. The effectiveness of utilizing SCs to maintain the system voltage at optimal levels in a fully solar grid is also considered. In addition, this paper covers the weak grid analysis via utilizing the Newton-Raphson load flow method, along with PV and QV curve analyses. The purpose behind that is to determine weak bus locations in need of voltage improvements, and to meet the amount of reactive power to be injected. Finally, the amount of power being delivered by SCs will be added progressively in three scenarios to show the enhancements on SCR more precisely.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

Enhanced charge carrier extraction and transport with interface modification for efficient tin-based perovskite solar cells

Interface modification improves charge carrier extraction in tin-based perovskite solar cells. Tin-based perovskites have become the most promising non-lead perovskites due to their ideal band gap and low toxicity. Although the open circuit voltage of tin-based perovskite solar cells (TPSCs) continues to approach the theoretical value, the short-circuit current is still far from the theoretical value. Here, we describe an interface modification method by regulating the property of hole transport layer, PEDOT:PSS, which improves the surface molecular morphology and the energy level alignment of PEDOT:PSS/perovskite interface. Advanced GIWAXS and IR s-SNOM characterization are conducted to achieve multi-dimensional characterization of nanoscale surface morphology and chemical distribution of PEDOT:PSS. With the multi-attribute optimization, charge carrier extraction and non-radiative recombination are also improved. The resultant TPSCs exhibit a higher power conversion efficiency of 13.32% in compared with the control device of 10.50%, accompanied with an increase in the short-circuit current from 18.10 to 20.50 mA cm −2 and FF from 68.23% to 76.43%. This work demonstrates a reliable strategy for improving charge carrier extraction and device performance for lead-free TPSCs.

Zhao, Zhenzhu↗

Electronic, direct optical, and phonon-assisted optical properties of 4H Si from first principles

The cubic polytype of silicon (Si) is the most commercialized semiconductor material and finds applications in numerous electronic and optoelectronic devices, such as solar cells. However, recent reports on the synthesis of the hexagonal 4H Si polytype have attracted the attention of the scientific community to understand its functional properties. Here, we report the electronic, vibrational, and optical properties of the 4H Si polytype obtained with predictive first-principles calculations, with an emphasis of phonon-assisted absorption in the indirect regime. Compared to the cubic polytype, 4H Si shows a slightly narrower indirect gap by ∼0.05 eV. The calculated phonon-assisted optical spectra show that 4H Si exhibits a stronger absorption coefficient than cubic Si across the visible and IR spectral regions. We further evaluate the short-circuit current density of textured thin-films. We demonstrate that 4H Si can achieve the same short-circuit current density for a five times thinner film compared to the cubic polytype, which mainly resulted from absorption in the indirect gap regime. Our work demonstrates the advantages of 4H Si for thin-film silicon-based solar-cell applications.

Materials Science↗

Modeling Extreme Deformations in Lithium Ion Batteries

A simultaneously coupled modeling approach to study the electrochemical and thermal behavior of lithium-ion batteries under large mechanical deformation has been developed. The thermo-electrochemical pseudo-2D (P2D) battery model is coupled with a mechanical material model. Mechanical, thermal, and electrochemical models are implemented as user-defined sub-routines in the commercial multi-physics code LS-DYNA. The mechanical strain experienced by anode, cathode and separator results in thickness and porosity changes in each layer which in turn influences electrochemical behavior. The evolution of concentration profiles and cell potential are studied under different mechanical loading conditions. Internal short-circuits caused by mechanical deformation and corresponding physical behaviors are also elucidated. We discuss the competing effects of improved transport at higher temperature due to the internal short-circuit versus a drop in the effective ionic conductivity and electrolyte diffusivity due to mechanical deformation.

47 OTHER INSTRUMENTATION↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses

14 SOLAR ENERGY↗

Observation and Modeling of the Thermal Runaway of High-Capacity Pouch Cells Due to an Internal Short Induced by an Indenter

Owing to the complexity of coupling mechanical and electrical solvers for finite element analysis (FEA) of mechanical abuse of a battery, the simulation should be performed by incorporating a local short circuit model activated based on the status of battery elements. However, the approach should also consider various other conditions of the battery simulated, such as the initial state of charge (SOC), for precise simulations of the internal short. This study proposes an approach developed with a mechanical model and single-particle battery model, along with a reaction kinetics model for thermal abuse using LS-DYNA. Several key parameters were selected, such as the activation criteria, kinetic abuse and element integration points during the internal short circuit induced by the indenter. The impact of these key parameters in the FEA on thermal runaway response for various initial SOCs from 25 to 100 % were analyzed. The FEA results obtained were compared against experimental results with various parameters such as activation criterion of internal short, kinetic abuse based on accelerating rate calorimetry (ARC) data. Finally, the root causes of the discrepancy between the FEA and experimental results are discussed regarding integration point what solver can make difference during calculation.

ENERGY STORAGE↗

Performance and durability of electrically conductive tape for shingled Si heterojunction technology cells

We report electrically conductive tape (ECT) was characterized and used to assemble shingled cell strings at low temperature to achieve high reliability Pb- and Ag-free interconnections. The volume resistivity for two considered ECTs are 0.13 ± 0.06 mΩ·cm and 0.47 ± 0.20 mΩ·cm and specific contact resistances, 6.85± 2.00 mΩ·cm 2 and 6.30 ± 0.37 mΩ·cm 2 using the emerging IEC 62788-8-1 Technical Specification for assessment of electrically conductive adhesives (ECA). Durability and performance of the technology in glass–glass mini modules were evaluated with temperature cycling, damp heat testing, and combined-accelerated stress testing (CAST). Through temperature cycling (-40°C to 85°C) applying five times the mini module short-circuit current in forward bias and in the multi climate CAST protocol, there was negligible degradation of fill factor after replacing connectors at the modules' cable leads; however, CAST resulted in short circuit current loss attributed to degradation in light collection by the cells, not the ECT. The IEC 61215-2 85°C, 85% relative humidity damp heat testing showed susceptibility of the HJT cells to effects of humidity in the electroluminescence intensity around the module perimeter that degraded power performance by 4% (relative). Contrasting the IEC 61215-2 qualification testing-based damp heat testing with CAST, factors such as the optical stress of CAST may precipitate the degradation of the modules whereas the humidity levels and duration of IEC 61215-2 damp heat testing may lead to excessive levels of humidity diffused into the modules, potentially resulting in degradation that is unrepresentative of the field.

14 SOLAR ENERGY↗

Prevention of lithium-ion battery thermal runaway using polymer-substrate current collectors

Isolating electronically conducting material from internal short circuits is a promising way to prevent the onset of thermal runaway within lithium-ion cells. Here, a metal-coated polymer current collector, which is designed to disconnect internal short circuits by withdrawing from the heating region, is tested in 18650 cells. In addition to having lower mass and manufacturing costs, cells with metal-coated polymer current collectors demonstrate a reduced risk of thermal runaway during nail penetration. High-speed synchrotron X-ray radiography of 18650 cells during nail-penetration testing, in tandem with pre- and post-mortem X-ray computed tomography, provides insights into the function of the current collectors. The results are compared with those of 18650 cells with standard commercial aluminum and copper current collectors. Cells with aluminum-coated polymer current collectors demonstrated 100% success in thermal runaway prevention during nail penetration, retaining a cell voltage >4.00 V, while standard cells consistently experienced thermal runaway.

25 ENERGY STORAGE↗

Bulk photovoltaic effect in hexagonal LuMnO 3 single crystals

Hexagonal manganites, such as h-LuMnO 3 , are ferroelectric and have a narrow electronic band gap of ≈1.5eV. Here we report on the photoresponse of h-LuMnO 3 single crystals. It is found that the short circuit photocurrent density (J sc ) and the open circuit voltage (V oc ) are dependent on the direction of the polarization plane of a linearly polarized impinging light. Its angular dependence indicates the contribution of bulk photovoltaic effect to the short circuit photocurrent (J BPE ). It is also observed that a switchable drift photocurrent, originating from the depoling field of the ferroelectric and thus tunable(<10%) by its polarization direction, also contributes to J sc . Although its presence precludes accurate determination of the bulk photovoltaic tensor elements and Glass coefficients, some bounds can be established. The Glass coefficients are found to be significantly larger than those obtained in BiFeO 3 . We argue that the smaller band gap of h-LuMnO 3 , its distinctive bipyramidal crystal field, and electronic configuration (3d 4 vs 3d 5 ), account for the difference and suggest a path towards ferroelectrics of higher photoconversion efficiency.

14 SOLAR ENERGY↗

Effects of Trigger Method on Fire Propagation during the Thermal Runaway Process in Li-ion Batteries

Lithium-ion batteries are prone to fire hazards due to the possibility of thermal runaway propagation. During battery product development and subsequent safety tests for design validation and safety certification, the thermal runaway onset is triggered by various test methods such as nail penetration, thermal ramp, or external short circuit. This failure initiation method affects the amount of heat contributions and the composition of gas generations. This study compares two such trigger methods, external heating and using a thermally-activated internal short circuit device (ISCD). The effects of the trigger method on total heat generation are experimentally investigated within 18650 cylindrical cells at single cell level as well as at multiple cell configuration level. The severity of failure was observed to be worse for cells with ISCDs at single cell level, whereas quite the opposite results were observed at multiple cell configuration level. A preliminary numerical analysis was performed to better understand the battery safety performance with respect to thermal runaway trigger methods and heat transfer conditions.

25 ENERGY STORAGE↗

An Investigation of Chemo-Mechanical Phenomena and Li Metal Penetration in All-Solid-State Lithium Metal Batteries Using In Situ Optical Curvature Measurements

Solid-electrolytes (SEs) can provide a pathway to increase energy-density in lithium metal batteries. However, lithium metal penetration through garnet based LLZO solid electrolytes has been identified as a critical failure process. This phenomenon is related to chemo-mechanical processes which are difficult to probe. In particular, characterizing the dynamic mechanical deformations that occur in electrode-SE structures is very challenging. Here study reports in situ curvature measurements that are thus designed to probe chemo-mechanical phenomena that occur during lithium plating. The novel experimental cell configuration created for this work shows that pressure builds up in the Li metal during plating, up until the point where short circuits occur. The resulting data are analyzed with a detailed finite element model (FEM) to quantitatively evaluate stress evolution. The results show that Li metal plating within a surface flaw can produce stress build-up prior to short-circuiting. The combined results from both the experiments and the FEM suggest that it is critical to minimize surface defects and flaws during the manufacturing processes.

25 ENERGY STORAGE↗