Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Short circuit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Gas-driven short disconnection mitigates thermal runaway in Li-ion batteries under mechanical abuse

Mechanical abuse poses a critical safety risk to Li-ion batteries by inducing internal short circuits that initiate thermal runaway. Remarkably, voltage recovery frequently emerges during thermal runaway initiation, a phenomenon that conventional theories fail to explain. Here, our study develops a new multiphysics mechanism to explain voltage recovery, termed gas-driven short disconnection, whereby internal gas pressure mechanically disengages short-circuit contacts and causes the cell voltage to rebound. This mechanism incorporates gas generation and its structural impact on the short circuit. Real-time optical and thermal imaging and X-ray computed tomography reveal fluid-structure interaction between internal gas flow and adjacent shorting contacts. We establish a mechanistic framework linking gas-driven short disconnection to cell-level voltage and temperature responses, elucidating the extension–truncation pattern of voltage recovery. Furthermore, thermal regime maps show that a voltage recovery duration exceeding 5 s correlates with limited temperature rise below 150 °C, indicating that sustained short-circuit disconnection suppresses Joule heating. Additionally, a dimensionless criterion is deduced from scaling analysis for physical plausibility of gas-driven short disconnection in mechanically abused cells. This finding inspires smart venting control, which regulates gas release to maintain the internal pressure while dissipating gas enthalpy, thereby providing a device-level strategy for thermal runaway mitigation.

Gas-driven short disconnection↗

Status of power generation experiments in the NASA Lewis closed-cycle MHD facility.

In this paper the design and operation of the closed-cycle MHD facility is discussed and results obtained in recent experiments are presented. The main components of the facility are a compressor, recuperative heat exchanger (preheater), heater, nozzle, MHD channel with 28 pairs of thoriated tungsten electrodes, cesium condenser, and an argon cooler. The heater can supply 1.1 MW of thermal power to a 2.27 kg/sec gas stream. The facility has been operated at temperatures up to 2100 K with a cesium-seeded argon working fluid. At low magnetic field strengths (B = 0.2 T), the open circuit voltage, Hall voltage and short circuit current obtained are 90, 69, and 47 percent of the theoretical equilibrium values, respectively. The Hall voltage and short circuit current decrease sharply with increasing magnetic field strength, however. Comparison of these data with a wall and boundary layer leakage theory indicates that the generator has shorting paths in the Hall direction.

Sovie, R. J.↗

Composite Thermal Switch

Lithium primary and lithium ion secondary batteries provide high specific energy and energy density. The use of these batteries also helps to reduce launch weight. Both primary and secondary cells can be packaged as high-rate cells, which can present a threat to crew and equipment in the event of external or internal short circuits. Overheating of the cell interior from high current flows induced by short circuits can result in exothermic reactions in lithium primary cells and fully charged lithium ion secondary cells. Venting of the cell case, ejection of cell components, and fire have been reported in both types of cells, resulting from abuse, cell imperfections, or faulty electronic control design. A switch has been developed that consists of a thin layer of composite material made from nanoscale particles of nickel and Teflon that conducts electrons at room temperature and switches to an insulator at an elevated temperature, thus interrupting current flow to prevent thermal runaway caused by internal short circuits. The material is placed within the cell, as a thin layer incorporated within the anode and/or the cathode, to control excess currents from metal-to-metal or metal-to-carbon shorts that might result from cell crush or a manufacturing defect. The safety of high-rate cells is thus improved, preventing serious injury to personnel and sensitive equipment located near the battery. The use of recently available nanoscale particles of nickel and Teflon permits an improved, homogeneous material with the potential to be fine-tuned to a unique switch temperature, sufficiently below the onset of a catastrophic chemical reaction. The smaller particles also permit the formation of a thinner control film layer (<50 m), which can be incorporated into commercial high-rate lithium primary and secondary cells. The innovation permits incorporation in current lithium and lithium-ion cell designs with a minimal impact on cell weight and volume. The composite thermal switch (CTS(TradeMark)) coating can be incorporated in either the anode or cathode or both. The coating can be applied in a variety of different processes that permits incorporation in the cell and electrode manufacturing processes. The CTS responds quickly and halts current flow in the hottest parts of the cell first. The coating can be applied to metal foil and supplied as a cell component onto which the active electrode materials are coated.

McDonald, Robert↗

Application of the superposition principle to solar-cell analysis

The superposition principle of differential-equation theory - which applies if and only if the relevant boundary-value problems are linear - is used to derive the widely used shifting approximation that the current-voltage characteristic of an illuminated solar cell is the dark current-voltage characteristic shifted by the short-circuit photocurrent. Analytical methods are presented to treat cases where shifting is not strictly valid. Well-defined conditions necessary for superposition to apply are established. For high injection in the base region, the method of analysis accurately yields the dependence of the open-circuit voltage on the short-circuit current (or the illumination level).

Lindholm, F. A.↗

New Active Optical Technique Developed for Measuring Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

Polymers such as polyimide Kapton (DuPont) and Teflon FEP (DuPont, fluorinated ethylene propylene) are commonly used spacecraft materials because of desirable properties such as flexibility, low density, and in the case of FEP, a low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low-Earth-orbit (LEO) environment are exposed to energetic atomic oxygen. Atomic oxygen reaction with polymers causes erosion, which is a threat to spacecraft performance and durability. It is, therefore, important to understand the atomic oxygen erosion yield E (the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. The most common technique for determining E is a passive technique based on mass-loss measurements of samples exposed to LEO atomic oxygen during a space flight experiment. There are certain disadvantages to this technique. First, because it is passive, data are not obtained until after the flight is completed. Also, obtaining the preflight and postflight mass measurements is complicated by the fact that many polymers absorb water and, therefore, the mass change due to water absorption can affect the E data. This is particularly true for experiments that receive low atomic oxygen exposures or for samples that have a very low E. An active atomic oxygen erosion technique based on optical measurements has been developed that has certain advantages over the mass-loss technique. This in situ technique can simultaneously provide the erosion yield data on orbit and the atomic oxygen exposure fluence, which is needed for erosion yield determination. In the optical technique, either sunlight or artificial light can be used to measure the erosion of semitransparent or opaque polymers as a result of atomic oxygen attack. The technique is simple and adaptable to a rather wide range of polymers, providing that they have a sufficiently high optical absorption coefficient. If one covers a photodiode with a uniformly thick sheet of semitransparent polymer such as Kapton H polyimide, then as atomic oxygen erodes the polymer, the short-circuit current from the photodiode will increase in an exponential manner with fluence. This nonlinear response with fluence results in a lack of sensitivity for measuring low atomic oxygen fluences. However, if one uses a variable-thickness polymer or carbon sample, which is configured as shown in the preceding figure, then a linear response can be achieved for opaque materials using a parabolic well for a circular geometry detector or a V-shaped well for a rectangular-geometry detector. Variable-thickness samples can be fabricated using many thin polymer layers. For semitransparent polymers such as Kapton H polyimide, there is an initial short-circuit current that is greater than zero. This current has a slightly nonlinear dependence on atomic oxygen fluence in comparison to opaque materials such as black Kapton as shown in the graph. For this graph figure, the total thickness of Kapton H was assumed to be 0.03 cm. The photodiode short-circuit current shown in the graph was generated on the basis of preliminary measurements-a total reflectance rho of 0.0424 and an optical absorption coefficient a of 146.5 cm(sup -1). In addition to obtaining on-orbit data, the advantage of this active erosion and erosion yield measurement technique is its simplicity and reliance upon well-characterized fluence witness materials as well as a nearly linear photodiode short-circuit current dependence upon atomic oxygen fluence. The optical technique is useful for measuring either atomic oxygen fluence or erosion, depending on the information desired. To measure the atomic oxygen erosion yield of a test material, one would need to have two photodiode sensors, one for the test material and one that uses a known erosion yield material (such as Kapton) to measure the atomic oxygen fluence.

Banks, Bruce A.↗

Examples of X-Ray Characterization Techniques in Energy Storage Research

Lithium-ion batteries have revolutionized the portable electronics and transportation sectors. Their performance is often critically dependent on the crystal structures of the anode and cathode electrode materials, which must enable the transport and reversible storage of lithium ions into and out of the lattice. Because lithium is a low-Z element, characterization of materials for lithium-ion batteries can be particularly challenging. Regardless, X-ray techniques enable analysis of material structures to better understand how battery materials perform and degrade, particularly when combined with other materials characterization and electrochemical characterization techniques. While X-ray techniques are most often used in battery research for phase identification of crystal structures, X-ray characterization techniques are also used for a wide variety of other purposes. I will discuss several examples from my research with various collaborators on several projects that highlight the impact that X-ray characterization techniques can have on battery research. The first example will focus on low-temperature microwave-assisted solvothermal synthesis of vanadium-doped LiFePO4 cathode materials for lithium-ion batteries. (1,2) Through a combination of electrochemical and materials characterization, we determined that low temperature synthesis resulted in metastable phases that enabled incorporation of higher dopant levels than resulting from high-temperature synthesis of thermodynamically stable phases. Rietveld refinement of X-ray diffraction data enabled understanding of how lattice parameters changed with doping levels and synthesis temperature. X-ray absorption near edge spectroscopy enabled understanding of the vanadium and iron oxidation states to confirm how vacancies in the structure caused by doping were charge compensated. This was important to understand because the literature suggests doping can improve LiFePO4 electrical conductivity, which improves battery charge and discharge rates. The second example will focus on understanding residual strain in lithium metal anodes. Lithium-ion batteries typically use graphite anodes, but the charge-storage capacity can be theoretically improved ~10x by using lithium metal as the anode material instead. However, lithium anodes suffer from growth of high-aspect-ratio features, such as dendrites, that can pierce nanoporous polymer separators and lead to short circuits and fires. External pressure is commonly applied to cells to enable better morphological control. We hypothesized that applied pressure may promote strain and possibly work hardening during electrochemical cycling, which motivated us to look for evidence of residual strain in lithium metal cycled under applied pressure using X-ray diffraction and sin2(..psi..) analysis. We found that lithium electrodeposited under high pressure exhibited in-plane compressive strain and that that lithium electrodeposited under low pressure did not. (3) The residual strain that accompanies electrodeposition under high pressure may lead to work hardening, which may explain how a soft metal like lithium can puncture separators and why higher pressure does not always decrease short circuits. (4-6) References: 1) Harrison, K. L.; Manthiram, A. Microwave-Assisted Solvothermal Synthesis and Characterization of Metastable LiFe1- x (VO) x PO4 Cathodes. Inorganic chemistry 2011, 50(8), 3613-3620. 2) Harrison, K. L.; Bridges, C. A.; Paranthaman, M. P.; Segre, C. U.; Katsoudas, J.; Maroni, V. A.; Idrobo, J. C.; Goodenough, J. B.; Manthiram, A. Temperature Dependence of Aliovalent-Vanadium Doping in LiFePO4 Cathodes. Chemistry of Materials 2013, 25(5), 768-781. 3) Rodriguez, M. A.; Harrison, K. L.; Goriparti, S.; Griego, J. J.; Boyce, B. L.; Perdue, B. R. Use of a Be-Dome Holder for Texture and Strain Characterization of Li Metal Thin Films via Sin2 (..psi..) Methodology. Powder Diffraction 2020, 35(2), 89-97. 4) Jungjohann, K. L.; Gannon, R. N.; Goriparti, S.; Randolph, S. J.; Merrill, L. C.; Johnson, D. C.; Zavadil, K. R.; Harris, S. J.; Harrison, K. L. Cryogenic Laser Ablation Reveals Short-Circuit Mechanism in Lithium Metal Batteries. ACS Energy Letters 2021, 6(6), 2138-2144. 5) Harrison, K. L.; Merrill, L. C.; Long, D. M.; Randolph, S. J.; Goriparti, S.; Christian, J.; Warren, B.; Roberts, S. A.; Harris, S. J.; Perry, D. L. Cryogenic Electron Microscopy Reveals That Applied Pressure Promotes Short Circuits in Li Batteries. Iscience 2021, 24(12). 6) Harrison, K. L.; Goriparti, S.; Merrill, L. C.; Long, D. M.; Warren, B.; Roberts, S. A.; Perdue, B. R.; Casias, Z.; Cuillier, P.; Boyce, B. L. Effects of Applied Interfacial Pressure on Li-Metal Cycling Performance and Morphology in 4 M LiFSI in DME. ACS Applied Materials & Interfaces 2021, 13(27), 31668-31679.

batteries↗

Apollo 13 Mission: Cryogenic Oxygen Tank 2 Anomaly Report

There were two investigative aspects associated with the loss of the cryogenic oxygen tank pressure during the Apollo 13 flight. First, what was the cause of the flight failure of cryogenic oxygen tank 2. Second, what possible contributing factors during the ground history of the tank could have led to the ultimate failure in flight. The first flight indication of a problem occurred when the quantity measurement in the tank went full scale about 9 hours before the incident. This condition in itself could not have contributed to ignition in the tank, since the energy in the circuit is restricted to about 7 milli-joules. Data from the electrical system provided the second indication of a problem when the fans in tank 2 were activated to reduce any stratification which might have been present in the supercritical oxygen in the tank. Several short-circuits were detected and have been isolated to the fan circuits of tank 2. The first short-circuit could have contained as much as 160 joules of energy, which is within the current-protection level of the fan circuits. Tests have shown that two orders of magnitude less energy than this is sufficient to ignite the polytetrafluoroethylene insulation on the fan circuits in the tank. Consequently, the evidence indicates that the insulation on the fan wiring was ignited by the energy in the short-circuit.

Source record↗

RF tuning element

A device for tuning a circuit includes a substrate, a transmission line on the substrate that includes first and second conductors coupled to a circuit to be tuned, and a movable short-circuit for varying the impedance the transmission line presents to the circuit to be tuned. The movable short-circuit includes a dielectric layer disposed atop the transmission line and a distributed shorting element in the form of a conductive member that is configured to be slid along at least a portion of the transmission line atop the dielectric layer. The conductive member is configured to span the first and second conductors of the transmission line and to define at least a first opening that spans the two conductors so that the conductive member includes first and second sections separated by the first opening. The first and second sections of the conductive member combine with the first and second conductors of the transmission line to form first and second low impedance sections of transmission line, and the opening combines with the first and second conductors of the transmission line and the dielectric layer to form a first high impedance section of transmission line intermediate the first and second low impedance sections. Each of the first low impedance section and the first high impedance section have a length along the transmission line of approximately one-quarter wavelength, thus providing a periodic variation of transmission line impedance. That enhances reflection of rf power.

McGrath, William R.↗

The drift field model applied to the lithium-containing silicon solar cell

The drift field model used by Wolf (1963) to calculate the short-circuit current was extended to permit calculations of the open-circuit voltage and the maximum power under conditions of illumination of either tungsten (2800 C) source or air mass zero sunlight. Voltages were calculated using an expression for the drift field diode saturation current. The model, applied to the oxygen-rich (C-13 group) lithium solar cells, was used to calculate the pre- and post-electron bombardment trends of the open-circuit voltage, maximum power, and short-circuit current for lithium gradients in the range from 10 to the 18th power to 10 to the 19th power Li/cm to the 4th power. Diffusion length degradation and carrier removal effects were sufficient to predict the cell performance up to 3 x 10 to the 14th electrons per sq cm. Beyond this fluence it was necessary to include drift field removal effects.

Godlewski, M. P.↗

Coaxial stub tuner

A coaxial stub tuner assembly is comprised of a short circuit branch diametrically opposite an open circuit branch. The stub of the short circuit branch is tubular, and the stub of the open circuit branch is a rod which extends through the tubular stub into the open circuit branch. The rod is threaded at least at its outer end, and the tubular stub is internally threaded to receive the threads of the rod. The open circuit branch can be easily tuned by turning the threaded rod in the tubular stub to adjust the length of the rod extending into the open circuit branch.

Chern, Shy-Shiun↗

Experimental investigation of flow distribution in enhanced geothermal systems with deep eutectic solvent

Geothermal energy has been recognized as a valuable alternative to fossil fuels and nuclear power, as it is renewable and reliable. Enhanced Geothermal Systems (EGSs) have the potential to expand geothermal energy production by enabling access to previously untapped geothermal resources. Geothermal short-circuiting poses a significant challenge to EGS development, leading to reduced heat extraction. Deep Eutectic Solvent (DES) exhibits favorable thermal and rheological properties, making it a candidate for geothermal applications. Here, this paper examines Choline Chloride-Based Deep Eutectic Solvent (DES) as a working fluid in geothermal applications and its potential to mitigate geothermal short-circuiting. Hydraulic experiments using a dual fracture flow loop were conducted at high temperatures. The results showed that DES exhibited higher differential pressure behavior compared to water. Flow distribution results revealed that DES enhances flow allocation within the small fracture, particularly when a temperature difference exists between fractures. Specifically, DES increased flow distribution by an average of 11% when the temperature difference was 85°C, and by 13% when the difference was 45°C, relative to water. These findings suggest that DES responds to thermal fracture differences, making it a potential remedy to address geothermal short-circuiting.

15 GEOTHERMAL ENERGY↗

Materials International Space Station Experiment-6 (MISSE-6) Atomic Oxygen Fluence Monitor Experiment

An atomic oxygen fluence monitor was flown as part of the Materials International Space Station Experiment-6 (MISSE-6). The monitor was designed to measure the accumulation of atomic oxygen fluence with time as it impinged upon the ram surface of the MISSE 6B Passive Experiment Container (PEC). This was an active experiment for which data was to be stored on a battery-powered data logger for post-flight retrieval and analysis. The atomic oxygen fluence measurement was accomplished by allowing atomic oxygen to erode two opposing wedges of pyrolytic graphite that partially covered a photodiode. As the wedges of pyrolytic graphite erode, the area of the photodiode that is illuminated by the Sun increases. The short circuit current, which is proportional to the area of illumination, was to be measured and recorded as a function of time. The short circuit current from a different photodiode, which was oriented in the same direction and had an unobstructed view of the Sun, was also to be recorded as a reference current. The ratio of the two separate recorded currents should bear a linear relationship with the accumulated atomic oxygen fluence and be independent of the intensity of solar illumination. Ground hyperthermal atomic oxygen exposure facilities were used to evaluate the linearity of the ratio of short circuit current to the atomic oxygen fluence. In flight, the current measurement circuitry failed to operate properly, thus the overall atomic oxygen mission fluence could only be estimated based on the physical erosion of the pyrolytic graphite wedges. The atomic oxygen fluence was calculated based on the knowledge of the space atomic oxygen erosion yield of pyrolytic graphite measured from samples on the MISSE 2. The atomic oxygen fluence monitor, the expected result and comparison of mission atomic oxygen fluence based on the erosion of the pyrolytic graphite and Kapton H atomic oxygen fluence witness samples are presented in this paper.

Banks, Bruce A.↗

Multijunction high voltage concentrator solar cells

The standard integrated circuit technology has been developed to design and fabricate new innovative planar multi-junction solar cell chips for concentrated sunlight applications. This 1 cm x 1 cm cell consisted of several voltage generating regions called unit cells which were internally connected in series within a single chip resulting in high open circuit voltages. Typical open-circuit voltages of 3.6 V and short-circuit currents of 90 ma were obtained at 80 AM1 suns. A dramatic increase in both short circuit current and open circuit voltage with increased light levels was observed.

Valco, G. J.↗

Development and pilot line production of lithium doped silicon solar cells

Scaling up the BCl3 without O2 diffusion beyond 30 to 40 cells was investigated by using a 100 cell capacity diffusion boat which held the cells vertically. Sheet resistances and I-V curves were uniform with 10 to 20 cells spaced along the entire boat, so the quantity was increased to 40 and then 60 cells per diffusion. There was no change in cell output and uniformity going from 20 to 40 cells per diffusion; however only half the lithium cells fabricated from slices diffused in the 60 cell diffusion had efficiencies of 11% or better. Although uniform sheet resistances and I-V characteristic curves were obtained with up to 60 cells in the BCl3 with O2 diffusion, the short circuit currents were approximately 15% lower than the anticipated 135 to 140 mA. Consequently, work on this diffusion process has been aimed solely at increasing the short circuit current. The diffusion temperature was lowered from 1055 to 1000 and 950 C, and at each of these temperatures variations in diffusion time were investigated. At 1000 C short circuit currents were approximately 10 mA higher, 130 rather than 120 mA average.

Payne, P. A.↗

Thermally-restorable optical degradation and the mechanism of current transport in Cu2S-CdS photovoltaic cells

The photovoltaic properties of single-crystal Cu2S-CdS heterojunctions have been investigated as a function of heat treatment by detailed measurements of the dependence of short-circuit current on photon energy, temperature, and the state of optical degradation or enhancement. A coherent picture is formulated for the relationship between enhancement and optical degradation, and their effect on the transport of short-circuit photoexcited current and dark, forward-bias current in the cell. Optical degradation in the Cu2S-CdS cell is shown to be closely identical to optical degradation of lifetime in a homogeneous CdS:Cd:Cu crystal, indicating that the CdS:Cu layer near the junction interface controls carrier transport in the cell. It is proposed that both the photoexcited short-circuit current and the dark, forward-bias current are controlled by a tunneling-recombination process through interface states.

Fahrenbruch, A. L.↗

Space Station resource node flow field analysis

An analysis of the flow field within the Space Station Freedom resource node with operational intermodule ventilation and temperature/humidity control ventilation systems has been conducted. The INS3D code, an incompressible, steady-state Navier-Stokes solver has been used to assess the design of the ventilation system via quantification of the level of fluid mixing and identification of 'dead air' regions and short-circuit ventilation. Numerical results indicate significant short-circuit ventilation in the forward and midsections of the node and insufficient fluid mixing is found to exist in the aft node section. These results as well as results from a solution grid dependence study are presented.

Kania, Lee↗

Reliability Models and Demonstration of a Fault-Tolerant Motor Concept for Vertical Takeoff and Landing Vehicles

This report documents the completion of the Revolutionary Vertical Lift Technology Project Annual Performance Indicator 24-3.2.4.1: “Apply and document reliability prediction for high reliability motor concept.” Two modeling tools were completed for calculation of reliability of fault-tolerant (FT) motors, and key FT operations of a modular FT motor were demonstrated experimentally. The two models are complementary tools for the stakeholder and user community. Both models employ Markov chain theory. The first model is a time-homogeneous Markov chain model, and the second is a time-inhomogeneous Markov-Weibull model. This report’s main sections are as follows: 1.0 Introduction, 2.0 Theory, 3.0 Motor Reliability Models, 4.0 Validation of FT Operation by Hardware Demonstration, and 5.0 Concluding Remarks. Novel contributions to the field include development of a modular FT motor concept for electrified vertical takeoff and landing (eVTOL) application, solution methods to solve the reliability calculations, development of figures of merit, and the introduction of “linked chains” to formulate a building-block approach for time-inhomogeneous Markov-Weibull modeling of motor reliability. Example case studies have been completed, and results are provided and discussed herein. A four-module FT motor concept was developed to a preliminary-design level of detail. This eVTOL FT motor concept was designed for galvanic, magnetic, and thermal isolation of stator winding faults. The reliability of the concept motor was calculated using a time-inhomogeneous Markov chain model. Employing average failure rate as a metric, 570 times greater reliability was achieved as compared to a baseline motor without fault tolerance. A demonstrator motor was built and tested. The testing demonstrated the key features of FT operation and validated the essential premises of the FT motor concepts presented herein. The experiments included successful demonstration of the feasibility of the following four key FT features: (1) terminal open-circuit operation, (2) thermal isolation after fault, (3) terminal short-circuit operation, and (4) internal short-circuit operation. These works indicate that FT modular motor drives offer promise for addressing the daunting reliability gap that electric aircraft propulsor drives are facing relative to the best conventional motor drive technology that is available today.

Electric Motor↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗