Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Setpoints”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Predictive Control of Residential Gas Storage Water Heaters [SWR-13-36]

Predictive Control of Residential Gas Storage Water Heaters provides an energy-efficient control method for residential gas storage water heaters. Predictive Control of Residential Gas Storage Water Heaters discovers users' hot water consumption patterns from historical data and automatically modulates the thermostat setpoints to conserve energy while maintaining thermal comfort. The starting time of hot water draw events is recorded and used for clustering analysis. Time intervals are generated from the clusters in which hot water draw events are more likely to occur. The setpoint is set at normal level to maintain thermal comfort, and decreased to a lower level outside these time intervals to reduce tank loss and thereby improving energy efficiency of the water heater.

Christensen, Dane↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Dialogue Between Lighting and HVAC Systems: Improving building system integration

Lighting systems have long been capable of sensing when someone enters or exits a room and using that knowledge to turn lights on or off. More recently, connected lighting systems with sensors integrated into every luminaire have become broadly available, facilitating highly granular occupancy detection. Similarly, HVAC systems have long been able to use an understanding of building occupancy to adjust temperature setpoints and reduce energy use without significant impacts to occupant comfort. Energy codes (e.g., ASHRAE/IES Standard 90.1, IECC, Title 24) now require “occupied standby HVAC control,” whereby systems adjust both temperature and ventilation setpoints in zones that are determined to be unoccupied during normal occupancy hours. Here, this article discusses current issues that stymie the integration of Lighting and HVAC systems, and DOE activities focused on addressing them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Closing the loop: model-predictive control for a closed-circuit reverse osmosis system

This article presents a model-predictive controller (MPC) for the maximization of the energy efficiency of a closed-circuit desalination reverse osmosis (CCRO) system. CCRO is a process for producing drinking water that is based on a cyclic operation with the following two phases: (a) filtration and (b) drain. In this article, we test model predictive control for optimal control of this process. The most important features of our approach are as follows: (a) the selection of a model structure that enables reliable forecasts of the filtration phase (up to 3 h), (b) an on-line model calibration strategy that ensures model forecast reliability, and (c) the satisfaction of equipment safety and operational constraints on the selected setpoints. We challenge this through deliberate introduction of changes in the unmeasured feed concentration and the applied constraints. Our results indicate that frequent model parameter updates are critical to maintain model reliability for MPC purposes. In addition, we illustrate that parameter identifiability is not guaranteed and that deliberate variation in flow rates is necessary even though the process never operates in steady state. Finally, MPC can compute flow rate setpoints that maximize the energy efficiency of the CCRO process while satisfying the applicable equipment and safety constraints.

closed-circuit reverse osmosis↗

BuildingIQ Technology Field Validation

This document describes a field validation and verification of the BuildingIQ Predictive Energy Optimization (PEO) technology based on a five-site study. BuildingIQ describes its PEO technology as a software-as-a-service (SaaS) platform that optimizes commercial building HVAC control for system efficiency, occupant comfort, and cost. It is targeted for use in large, complex buildings, and integrates with the building automation system (BAS) to conduct supervisory control. The PEO algorithm defines optimal space air temperature setpoints that are automatically implemented at the variable air volume (VAV) terminal units when possible, or through supply air temperature and duct static pressure setpoints at the air handling unit (AHU) level. The optimization is built upon a learned predictive model that provides a 24-hour ahead forecast of the building’s power profile, using weather forecasts and historical operational data; this model is updated every 4 to 6 hours. Demand-responsive load reductions may also be implemented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BuildingIQ Technology Field Validation

This document describes a field validation and verification of the BuildingIQ Predictive Energy Optimization (PEO) technology based on a five-site study. BuildingIQ describes its PEO technology as a software-as-a-service (SaaS) platform that optimizes commercial building HVAC control for system efficiency, occupant comfort, and cost. It is targeted for use in large, complex buildings, and integrates with the building automation system (BAS) to conduct supervisory control. The PEO algorithm defines optimal space air temperature setpoints that are automatically implemented at the variable air volume (VAV) terminal units when possible, or through supply air temperature and duct static pressure setpoints at the air handling unit (AHU) level. The optimization is built upon a learned predictive model that provides a 24-hour ahead forecast of the building’s power profile, using weather forecasts and historical operational data; this model is updated every 4 to 6 hours. Demand-responsive load reductions may also be implemented.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Supervisory Control System for Multi-Modular Advanced Reactors

The proposed supervisory control system (SCS) may provide considerable benefits to advanced small modular reactors, including reduced plant staffing, optimized maintenance activities, greater plant availability, and higher operating efficiency. The SCS makes risk-informed decisions based on (1) a probabilistic assessment of the likelihood of success given the status of the plant/systems and component health, and (2) a deterministic assessment between plant operating parameters and reactor protection parameters to prevent unnecessary trips and challenges to plant safety system—one measure of SCS success. The probabilistic portion of the decision-making engine of the SCS is based on the control actions associated with an advanced liquid-metal reactor (ALMR) Power Reactor, Innovative, Small Module (PRISM). Within the SCS, the probabilistic assessment provides a ranking of viable control actions; however, certain instructions generated by the probabilistic model only include an abstract notion of action without specifications. For instance, one instruction may be to reduce power without specifying how much reduction is needed. The prognostic/diagnostic models incorporate the health of components into the decision-making process. Once the control options are identified and ranked based on the likelihood of success, the SCS transmits the options to the deterministic portion of the platform. The performance-based system models assess and rank each of the probabilistically identified control actions by taking into account the physical behavior (current and projected) of the system. The performance-based decision making module receives inputs from the probabilistic decision-making module and the ERM module to generate a single solution. Interfaces to these modules are defined later in the section. A utility theory algorithm factors into the decision making by estimating the distance from and approach to a trip setpoint for each control option. If the magnitude of a negative utility value increases rapidly as the system approaches the trip setpoint, that option is not likely to be the preferred option. This can lead to a re-ranking of the control options. The SCS then transmits a control signal(s) to a component or system and informs the operator of actions taken based on the action chosen. The SCS successfully coupled probabilistic and performance-based system models to arrive at optimal control decisions based on the actual status of the plant and components. The automatic, autonomous, and real-time performance requirements for a control system were met by the SCS. The value of coupling probabilistic and performance-based system models was demonstrated by the re-ranking of control options based on the use of a utility algorithm. The use of ERM monitors provides added value to the SCS as demonstrated by the re-ranking of control options based on a components degraded state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

A Smart Alarm for the CEBAF Injector

We present initial results from a proof-of-concept ?smart alarm? for the CEBAF injector. Because of the injector's large number of parameters and possible fault scenarios, it is highly desirable to have an autonomous alarm system that can quickly identify and diagnose unusual machine states. Our approach leverages a trained neural network to not only identify an anomalous machine state, but also to identify the root-cause by pinpointing the specific element or region responsible. We developed an inverse model trained on data collected during normal operations. Using the inverse model, measurements from the machine are used to compute machine settings, which are then compared to EPICS setpoints. Instances when predictions differ from EPICS setpoints by a user-defined threshold are flagged as anomalies, and the user is alerted to the issue. We present the results of our data collection efforts, model training and performance, and initial performance metrics.

Tennant, C.↗

Distributed Rules-Based Deconfliction of ADMS Applications - Part 2: Conceptual Implementation

This work introduces a rules-based deconfliction methodology for resolving conflicting device control commands issued by advanced power applications considering a range of technical, economic, environmental, and social objectives. The methodology is designed to serve as one of multiple alternative implementations (along with application cooperation and global optimization) for the numerical component of the Deconfliction Pipeline. Development of the methodology is divided into two parts. The first document previously defined the requirements, context, and methods for decomposing the deconfliction problem using the Laminar Coordination Framework and Variable Grid Structures. The deconfliction problem was decomposed into a distributed optimization problem based on the concept of quasi-static grid segments, which form independent distributed areas for control and coordination. It was recommended that selection of the optimal number of decompositions of the deconfliction problem be made based on a tradeoff analysis between computational speed and global optimality. This second document defines an initial set of technical, economic, and environmental criteria, as well as thirty specific qualitative rules that are used as part of the deconfliction methodology to eliminate non-viable setpoint alternatives. The deconfliction optimization problem is converted into a ranking of individual discrete setpoints, which are scored by the extent to which they satisfy specific decision criteria. The ranking is determined through the concepts of deconfliction exclusivity, priority, and preference. Several multi-criteria decision-making frameworks are examined with the simple multi-attribute rating technique exploiting ranks (SMARTER) recommended as a simple implementation alternative that aligns with the steps of the rules-based deconfliction methodology.

97 MATHEMATICS AND COMPUTING↗

Distributed Rules-Based Deconfliction of ADMS Applications: Part 1: Requirements & Decomposition

This work introduces a rules-based deconfliction methodology for resolving conflicting device control commands issued by advanced power applications considering a range of technical, economic, environmental, and social objectives. The methodology is designed to serve as one of multiple alternative implementations (along with application cooperation and global optimization) for the numerical component of the Deconfliction Pipeline. Development of the methodology is divided into two parts. This first document introduces the requirements, context, and methods for decomposing the deconfliction problem using the Laminar Coordination Framework and Variable Grid Structures. The deconfliction problem is decomposed into a distributed optimization problem based on the concept of quasi-static grid segments, which form independent distributed areas for control and coordination. Selection of the optimal number of decompositions of the deconfliction problem should be made based on a tradeoff analysis between computational speed and global optimality. This second document will define an initial set of technical, economic, and environmental criteria, as well as thirty specific qualitative rules that are used as part of the deconfliction methodology to eliminate non-viable setpoint alternatives. The deconfliction optimization problem is converted into a ranking of individual discrete setpoints, which are scored by the extent to which they satisfy specific decision criteria. The ranking is determined through the concepts of deconfliction exclusivity, priority, and preference. Several multi-criteria decision-making frameworks are examined with the simple multi-attribute rating technique exploiting ranks (SMARTER) recommended as a simple implementation alternative that aligns with the steps of the rules-based deconfliction methodology.

97 MATHEMATICS AND COMPUTING↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alaska's Rural Building Stock: a Validation Study Using ResStock and Field Data

The availability of accurate national data on demographics, building stock, and energy use is vital for modeling residential buildings and evaluating decarbonization strategies. However, rural and Indigenous populations, including those in rural Alaska, are typically underrepresented in these datasets. These communities face unique challenges due to their remote locations, severe weather conditions, and limited access to resources, resulting in high energy burden. This report examines how rural Alaskan communities are underrepresented in the ResStock housing model and highlights the need for improved data to address their unique housing and energy challenges. Thus, this report examines the representation of rural Alaskan communities within the national housing stock model, ResStock. A validation study was conducted, considering ResStock, Field Data and Aerial and 3D-view data collection (A3DDC) datasets. The validation process started by using the down selecting approach on the ResStock building stock dataset. For the purpose of this study, only the rural Alaska Boroughs and Census areas located in ASHRAE IECC Climate Zone 8 were considered to ensure a more accurate and fair comparison with the field data, which was collected in rural areas located in climate zone 8, specifically within the Nome Census area. While ResStock may accurately represent several characteristics of the building stock for rural Alaska, some differences between modeled, field data, and aerial and 3D-view data collection datasets were identified. The following building characteristics have a high impact on modeled energy consumption and demonstrated large differences: Revisit heating setpoints and consider a substantially higher setpoint distribution, it could potentially address "missing loads" if this is the case. Develop and include Toyo heating in future modeling for ResStock and EnergyPlus. Remove natural gas as a water heater fuel type outside of North Slope County. Foundation type updated to have more crawlspaces rather than basements. Infiltration rates need reexamination for a larger distribution toward higher infiltration rates. Include more vinyl and less brick in exterior wall type and revise wall color for greater proportion of light rather than dark color. Roof material revised from majority shingles to majority metal. Update number of occupants to higher number of occupant count. Building orientation represents a higher proportion of south facing buildings rather than relatively equal. The findings suggest that updating ResStock's probability logic could better represent rural Alaskan buildings. ResStock can be utilized to identify the best upgrades or energy efficiency and energy efficiency improvements, helping community leaders in making more informed decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Regulation of Renewable Energy Sources to Optimal Power Flow Solutions Using ADMM

This paper considers power distribution systems featuring renewable energy sources (RESs), and develops a distributed optimization method to steer the RES output powers to solutions of AC optimal power flow (OPF) problems. The design of the proposed method leverages suitable linear approximations of the AC-power flow equations, and is based on the Alternating Direction Method of Multipliers (ADMM). Convergence of the RES-inverter output powers to solutions of the OPF problem is established under suitable conditions on the stepsize as well as mismatches between the commanded setpoints and actual RES output powers. In a broad sense, the methods and results proposed here are also applicable to other distributed optimization problem setups with ADMM and inexact dual updates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Analysis of the Effect of Vehicle Platooning on the Optimal Control of a Heavy Duty Engine Thermal System

One promising method for reducing fuel consumption and emissions, particularly in heavy duty trucks, is platooning. As the distance between vehicles decreases, the following vehicles will experience less aerodynamic drag on the front of the vehicle. However, reducing the velocity of the air contacting the front of the vehicle could have adverse effects on the temperature of the engine. To compensate for this effect, the energy consumption of the engine cooling system might increase, ultimately limiting the overall improvements obtained with platooning. Understanding the coupling between drag reduction and engine cooling load requirement is key for successfully implementing platooning strategies. Additionally, in a Connected and Automated Vehicle (CAV) environment, where information of the future engine load becomes available, the operation of the cooling system can be optimized in order to achieve the maximum fuel consumption reduction. In this paper, a control-oriented physics-based model for the engine cooling loop of a Volvo engine is developed and validated against road data. Starting from the validated model, an optimal control problem for the coolant system is formulated considering the tradeoff between the tracking of the engine temperature setpoint and the corresponding fuel consumption under different trailing distances. To compare the coolant system performance, Dynamic Programming (DP) is used to determine the global optimal solution for the coolant system actuator. The coupling between optimal cooling system operation and reduction in ram air are evaluated by comparing the results obtained from the DP under different platooning conditions against the unrestricted scenario. In addition, the paper analyzes the changes in the tradeoff between fuel consumption and setpoint tracking for different vehicle distances. This analysis will provide useful insight on the sensitivity of the coolant system controller calibration to the platoon distance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-driven Identification of Occupant Thermostat-Behavior Dynamics

Building occupant behavior drives significant differences in building energy use, even in automated buildings. Users’ distrust in the automation causes them to override settings. This results in responses that fail to satisfy both the occupants’ and/or the building automation’s objectives. The transition toward grid-interactive efficient buildings will make this evermore important as complex building control systems optimize not only for comfort, but also changing electricity costs. This paper presents a data-driven approach to study thermal comfort behavior dynamics which are not captured by standard steady-state comfort models such as predicted mean vote. The proposed model captures the time it takes for a user to override a thermostat setpoint change as a function of the manual setpoint change magnitude. The model was trained with the ecobee Donate Your Data dataset of 5 min. resolution data from 27,764 smart thermostats and occupancy sensors. The resulting population-level model shows that, on average, a 2°F override will occur after ~30 mins. and an 8°F override will occur in only ~15 mins., indicating the magnitude of discomfort as a key driver to the swiftness of an override. Such models could improve demand response programs through personalized controls.

Kane, Michael↗