Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Server power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Guideline for ground radiation testing of microprocessors in the space radiation environment

The goal of this work is to develop a guideline that is applicable to processors that are potentially useful in space. Thus, the guideline does not consider very high performance processors that are intended for server or high-performance applications where very large amounts of power are tolerated to gain performance because it would be impractical to use such high-power devices in typical space applications. This guide is intended to support insertion of these microprocessors into spaceflight applications and to recommend ground test protocols. The first guideline principle that should be followed is a serious concurrent engineering approach for down selecting space-qualified microprocessors. This requires that the design engineer seek the support of a radiation effects expert who understands total ionizing dose (TID) and single-event effects (SEEs) issues for microprocessors as applied to the system in question.

Irom, Farokh↗

Design of Smart Charging Infrastructure Hardware and Firmware Design of the Various Current Multiplexing Charging System

Currently, when Electric Vehicles (EVs) are charging, they only have the option to charge at a selected current or not charge. When during the day there is a power shortage, the charging infrastructure should have the options to either shut off the power to the charging stations or to lower the power to the EVs in order to satisfy the needs of the grid. There is a need for technology that controls the current being disbursed to these electric vehicles. This paper proposes a design for a smart charging infrastructure capable of providing power to several EVs from one circuit by multiplexing power and providing charge control. The smart charging infrastructure includes the server and the smart charging station. With this smart charging infrastructure, the shortage of energy in a local grid could be solved by our EV management system

Chung, Ching-Yen↗

Miniaturized Airborne Imaging Central Server System

In recent years, some remote-sensing applications require advanced airborne multi-sensor systems to provide high performance reflective and emissive spectral imaging measurement rapidly over large areas. The key or unique problem of characteristics is associated with a black box back-end system that operates a suite of cutting-edge imaging sensors to collect simultaneously the high throughput reflective and emissive spectral imaging data with precision georeference. This back-end system needs to be portable, easy-to-use, and reliable with advanced onboard processing. The innovation of the black box backend is a miniaturized airborne imaging central server system (MAICSS). MAICSS integrates a complex embedded system of systems with dedicated power and signal electronic circuits inside to serve a suite of configurable cutting-edge electro- optical (EO), long-wave infrared (LWIR), and medium-wave infrared (MWIR) cameras, a hyperspectral imaging scanner, and a GPS and inertial measurement unit (IMU) for atmospheric and surface remote sensing. Its compatible sensor packages include NASA s 1,024 1,024 pixel LWIR quantum well infrared photodetector (QWIP) imager; a 60.5 megapixel BuckEye EO camera; and a fast (e.g. 200+ scanlines/s) and wide swath-width (e.g., 1,920+ pixels) CCD/InGaAs imager-based visible/near infrared reflectance (VNIR) and shortwave infrared (SWIR) imaging spectrometer. MAICSS records continuous precision georeferenced and time-tagged multisensor throughputs to mass storage devices at a high aggregate rate, typically 60 MB/s for its LWIR/EO payload. MAICSS is a complete stand-alone imaging server instrument with an easy-to-use software package for either autonomous data collection or interactive airborne operation. Advanced multisensor data acquisition and onboard processing software features have been implemented for MAICSS. With the onboard processing for real time image development, correction, histogram-equalization, compression, georeference, and data organization, fast aerial imaging applications, including the real time LWIR image mosaic for Google Earth, have been realized for NASA fs LWIR QWIP instrument. MAICSS is a significant improvement and miniaturization of current multisensor technologies. Structurally, it has a complete modular and solid-state design. Without rotating hard drives and other moving parts, it is operational at high altitudes and survivable in high-vibration environments. It is assembled from a suite of miniaturized, precision-machined, standardized, and stackable interchangeable embedded instrument modules. These stackable modules can be bolted together with the interconnection wires inside for the maximal simplicity and portability. Multiple modules are electronically interconnected as stacked. Alternatively, these dedicated modules can be flexibly distributed to fit the space constraints of a flying vehicle. As a flexibly configurable system, MAICSS can be tailored to interface a variety of multisensor packages. For example, with a 1,024x1,024 pixel LWIR and a 8,984x6,732 pixel EO payload, the complete MAICSS volume is approximately 7x9x11 in. (=18x23x28 cm), with a weight of 25 lb (=11.4 kg).

Sun, Xiuhong↗

Wave Energy Prize - 1/50th Testing - Principle Power Oscillating Water Column

This submission of data includes all the 1/50th scale testing data completed on the Wave Energy Prize for the Principle Power team, and includes: - 1/50th test data (raw & processed) - 1/50th test data video and pictures - 1/50th Test plans and testing documents - SSTF_Submission (summarized results)

1/50th scale↗

Designing an autonomous environment for mission critical operation of the EUVE satellite

Since the launch of NASA's Extreme Ultraviolet Explorer (EUVE) satellite in 1992, there has only been a handful of occurrences that have warranted manual intervention in the EUVE Science Operations Center (ESOC). So, in an effort to reduce costs, the current environment is being redesigned to utilize a combination of off-the-shelf packages and recently developed artificial intelligence (AI) software to automate the monitoring of the science payload and ground systems. The successful implementation of systemic automation would allow the ESOC to evolve from a seven day/week, three shift operation, to a seven day/week one shift operation. First, it was necessary to identify all areas considered mission critical. These were defined as follows: (1) The telemetry stream must be monitored autonomously and anomalies identified. (2) Duty personnel must be automatically paged and informed of the occurrence of an anomaly. (3) The 'basic' state of the ground system must be assessed. (4) Monitors should check that the systems and processes needed to continue in a 'healthy' operational mode are working at all times. (5) Network loads should be monitored to ensure that they stay within established limits. (6) Connectivity to Goddard Space Flight Center (GSFC) systems should be monitored as well, not just for connectivity of the network itself but also for the ability to transfer files. (7) All necessary peripheral devices should be monitored. This would include the disks, routers, tape drives, printers, tape carousel, and power supplies. (8) System daemons such as the archival daemon, the Sybase server, the payload monitoring software, and any other necessary processes should be monitored to ensure that they are operational. (9) The monitoring system needs to be redundant so that the failure of a single machine will not paralyze the monitors. (10) Notification should be done by means of looking though a table of the pager numbers for current 'on call' personnel. The software should be capable of dialing out to notify, sending email, and producing error logs. (11) The system should have knowledge of when real-time passes and tape recorder dumps will occur and should know that these passes and data transmissions are successful. Once the design criteria were established, the design team split into two groups: one that addressed the tracking, commanding, and health and safety of the science payload and another group that addressed the ground systems and communications aspects of the overall system.

Abedini, Annadiana↗

Lanai high-density irradiance sensor network for characterizing solar resource variability of MW-scale PV system.

Sandia National Laboratories (Sandia) and SunPower Corporation (SunPower) have completed design and deployment of an autonomous irradiance monitoring system based on wireless mesh communications and a battery operated data acquisition system. The Lanai High-Density Irradiance Sensor Network is comprised of 24 LI-COR{reg_sign} irradiance sensors (silicon pyranometers) polled by 19 RF Radios. The system was implemented with commercially available hardware and custom developed LabVIEW applications. The network of solar irradiance sensors was installed in January 2010 around the periphery and within the 1.2 MW ac La Ola PV plant on the island of Lanai, Hawaii. Data acquired at 1 second intervals is transmitted over wireless links to be time-stamped and recorded on SunPower data servers at the site for later analysis. The intent is to study power and solar resource data sets to correlate the movement of cloud shadows across the PV array and its effect on power output of the PV plant. The irradiance data sets recorded will be used to study the shape, size and velocity of cloud shadows. This data, along with time-correlated PV array output data, will support the development and validation of a PV performance model that can predict the short-term output characteristics (ramp rates) of PV systems of different sizes and designs. This analysis could also be used by the La Ola system operator to predict power ramp events and support the function of the future battery system. This experience could be used to validate short-term output forecasting methodologies.

14 SOLAR ENERGY↗

New approach based on group technology for the consolidation problem in cloud computing-mathematical model and genetic algorithm

Resource management is a hotspot issue in distributed systems like cloud computing (CC). It means how to prepare the computational resources, i.e., servers and virtual machines (VMS), to execute the tasks. This paper offers a new approach based on Group Technology (GT)—known as a powerful philosophy for the resource management in cellular manufacturing systems—to deal with the resource management problem in CC. We develop a mathematical model to optimally consolidate the VMs, servers and tasks simultaneously to control several important factors such as task migrations and server load variation, as well as the number of VMs. To test the validity of our proposed model, several small problems are generated randomly and solved by LINGO 9 software. Furthermore, to cope with larger problems, which cannot be solved optimally, a genetic algorithm is proposed. We, finally, compare our methods with the most well-known algorithms in this context, round robin (RR) and first-come, first-served (FCFS) algorithms.

97 MATHEMATICS AND COMPUTING↗

SiC-Based Wireless Power Transformation for Data Centers & Medium Voltage Applications

Data centers have grown in physical size and their electrical power consumption has grown to levels of several 100kW and approaching 1 GW in large installations. The low voltage electrical distribution inside of Data Centers consists of several conversion stages and a lot of wiring to bring the power from medium voltage (MV) levels outside of the building to the low voltage levels that the servers and racks require. Energy losses during distribution and conversion and high incident arc flash energy levels at the point of use are significant. The electrical distribution system is complex and costly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recovery Act: A Measurement -- Management Technology for Improving Energy Efficiency in Data Centers and Telecommunication Facilities (Final Technical Report)

Data center (DC) electricity use is increasing at an annual rate of over 20% and presents a concern for the Information Technology (IT) industry, governments, and the society. A large fraction of the energy use is consumed by the compressor cooling to maintain the recommended operating conditions for IT equipment. The most common way to improve the DC efficiency is achieved by optimally provisioning the cooling power to match the global heat dissipation in the DC. However, at a more granular level, the large range of heat densities of today's IT equipment makes the task of provisioning cooling power optimized to the level of individual computer room air conditioning (CRAC) units much more challenging. Distributed sensing within a DC enables the development of new strategies to improve energy efficiency, such as hot spot elimination through targeted cooling, matching power consumption at rack level with workload schedule, and minimizing power losses. The scope of Measurement and Management Technologies (MMT) is to develop a software tool and the underlying sensing technology to provide critical decision support and control for DC and telecommunication facilities (TF) operations. A key aspect of MMT technology is integration of modeling tools to understand how changes in one operational parameter affect the overall DC response. It is demonstrated that reduced ordered models for DC can generate, in less than 2 seconds computational time, a three dimensional thermal model in a 50 kft 2 DC. This rapid modeling enables real time visualization of the DC conditions and enables "0what if" scenarios simulations to characterize response to "disturbances". One such example is thermal zone modeling that matches the cooling power to the heat generated at a local level by identifying DC zones cooled by a specific CRAC. Turning off a CRAC unit can be simulated to understand how the other CRAC utilization changes and how server temperature responds. Several new sensing technologies were added to the existing MMT platform: (1) air contamination (corrosion) sensors, (2) power monitoring, and (3) a wireless environmental sensing network. All three technologies are built on cost effective sensing solutions that increase the density of sensing points and enable high resolution mapping of DCs. The wireless sensing solution enables Air Conditioning Unit (ACU) control while the corrosion sensor enables air side economization and can quantify the risk of IT equipment failure due to air contamination. Validation data for six test sites demonstrate that leveraging MMT energy efficiency solutions combined with industry best practices results in an average of 20% reduction in cooling energy, without major infrastructure upgrades. As an illustration of the unique MMT capabilities, a data center infrastructure efficiency (DCIE) of 87% (industry best operation) was achieved. The technology is commercialized through IBM System and Technology Lab Services that offers MMT as a solution to improve DC energy efficiency. Estimation indicates that deploying MMT in existing DCs can results in an 8 billion kWh savings and projection indicates that constant adoption of MMT can results in obtainable savings of 44 billion kWh in 2035. Negotiations are under way with business partners to commercialize/license the ACU control technology and the new sensor solutions (corrosion and power sensing) to enable third party vendors and developers to leverage the energy efficiency solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy–Performance Trade-offs in Privacy-Preserving Federated Learning on SmartNIC-Enabled HPC Systems

Federated learning (FL) is increasingly deployed on accelerator-rich high-performance computing (HPC) systems, yet the system-level energy cost of privacy-aware FL remains poorly understood, particularly across heterogeneous networking and server-placement options. We present a measurement-driven study of energy–performance trade-offs for FL on GH200-class nodes across three deployment configurations: CPU-Ethernet, CPU-InfiniBand (RDMA-capable), and a DPU-hosted FL server over InfiniBand using a BlueField-3 SmartNIC/DPU. Using NVIDIA FLARE (NVFLARE), we align node-level power telemetry with per-round timing extracted from NVFLARE logs to quantify time-to-solution (TTS), energy-to-solution (ETS), energy-delay product (EDP), and synchronization behavior for three transformer models (ALBERT, DistilBERT, BERT), trained with and without differential privacy (DP). We find that interconnect choice is the dominant driver of runtime and energy: host-managed InfiniBand consistently reduces communication overhead versus Ethernet, yielding lower TTS/ETS/EDP. In contrast, in our NVFLARE deployment, placing the FL server on the DPU does not consistently match CPU-InfiniBand performance and can be slower—especially for larger models—highlighting that server placement alone is not sufficient to guarantee end-to-end gains. Finally, under our fixed-round protocol, DP increases per-round cost and runtime variance; ETS increases largely in proportion to TTS because average node power remains relatively stable across configurations.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Towards 100,000 CPU Cycle-Scavenging by Genetic Algorithms

We examine a web-centric design using standard tools such as web servers, web browsers, PHP, and mySQL. We also consider the applicability of Information Power Grid tools such as the Globus (no relation to the author) Toolkit. We intend to implement this architecture with JavaGenes running on at least two cycle-scavengers: Condor and United Devices. JavaGenes, a genetic algorithm code written in Java, will be used to evolve multi-species reactive molecular force field parameters.

Globus, Al↗

ADVANCING THE TRANSPORTATION – SECURITY, TRACKING, AND REPORTING (T-STAR) SYSTEM

The Transportation – Security, Tracking and Reporting (T-STAR) System was developed by NNSA NA-21 Office of Radiological Security (ORS) to provide a transportation security system for use during transport of Category 1 and Category 2 radiological material to provide detection and tracking capability for shipments. While many off the shelf systems provide asset tracking of the conveyance, few offer detection of a breach into the cargo compartment or the removal of cargo from the conveyance. Systems that do offer such capability need to be permanently installed on the conveyance, requiring drilling of holes and running of cables throughout the conveyance itself. This means that dedicated shipping containers or vehicles are required, and this is not sustainable in many countries where ORS is building capacity for the security of radioactive materials in use, storage, and in transport. T-STAR is leveraging various ORNL technologies for improved communications capability and reduced power requirements; the multimode communications module developed by the Unmanned Aerial Systems group and the low power and extensible Authenticatable Container Tracking System (ACTS) tag developed for the US Department of Energy’s Packaging Certification Program provide a small footprint tracking system which can be installed quickly as needed. T-STAR uses a cellular and an Iridium modem to communicate configuration and alert information to a server used to monitor the shipment and incorporates a Z-wave © wireless security system allowing various intrusion detection sensors to be located in the conveyance. The Z-wave sensors are readily available, inexpensive, and power efficient, making them replaceable and low maintenance. The server software be configured as a standalone system installed on a light duty computer hosted by the competent authority, carrier, or response agency, or hosted as part of an Amazon Cloud Server (AWS) accessible via a secure login. The server has two functions, first is to handle messages to/from the T-STAR field unit, second is to host the user interface which can be accessed using a web browser on desktop or mobile device. The user interface implements roles to determine the level of access to shipment information, define geo-fences, and configure notifications. The user interface also supports multiple languages for display as well as notifications by using a simple lookup file which can be modified by the host country to ensure translations are correct and meaningful to responders receiving notifications and alerts. This paper will detail the overarching T-STAR capabilities, architecture and components, and provide insights on how it is deployed, used, and monitored during transportation of radioactive material.

Schultze, Michael↗

Django Remote Submission

The Django Remote Submission (DRS) is a Django (Django, n.d.) application to manage long running job submission, including starting the job, saving logs, and storing results. It is an independent project available as a standalone pypi package (PyPi, n.d.). It can be easily integrated in any Django project. The source code is freely available as a GitHub repository (django-remote-submission, n.d.). To run the jobs in background, DRS takes advantage of Celery (Celery, n.d.), a powerful asynchronous job queue used for running tasks in the background, and the Redis Server (Redis, n.d.), an in-memory data structure store. Celery uses brokers to pass messages between a Django Project and the Celery workers. Redis is the message broker of DRS. In addition DRS provides real time monitoring of the progress of Jobs and associated logs. Through the Django Channels project (Channels, n.d.), and the usage of Web Sockets, it is possible to asynchronously display the Job Status and the live Job output (standard output and standard error) on a web page.

97 MATHEMATICS AND COMPUTING↗

Wireless Integrated Microelectronic Vacuum Sensor System

NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum-gauge measurements automatically and wirelessly, in near-real time - using a low-maintenance, lowpower sensor mesh network. The WIMVSS operates by using a self-configuring mesh network of wireless sensor units. Mesh networking is a type of networking where each sensor or node can capture and disseminate its own data, but also serve as a relay to receive and transmit data from other sensors. Each sensor node can synchronize with adjacent sensors, and propagate data from one sensor to the next, until the destination is reached. In this case, the destination is a Network Interface Unit (NIU). The WIMVSS sensors are mounted on the existing vacuum gauges. Information gathered by the sensors is sent to the NIU. Because of the mesh networking, if a sensor cannot directly send the data to the NIU, it can be propagated through the network of sensors. The NIU requires antenna access to the sensor units, AC power, and an Ethernet connection. The NIU bridges the sensor network to a WIMVSS server via an Ethernet connection. The server is configured with a database, a Web server, and proprietary interface software that makes it possible for the vacuum measurements from vacuum jacketed fluid lines to be saved, retrieved, and then displayed from any Web-enabled PC that has access to the Internet. Authorized users can then simply access the data from any PC with Internet connection. Commands can also be sent directly from the Web interface for control and maintenance of the sensor network. The technology enabled by the WIMVSS decreases labor required for gathering vacuum measurements, increases access to vacuum data by making it available on any computer with access to the Internet, increases the frequency with which data points can be acquired for evaluating the system, and decreases the recurring cost of the sensors by using off-the-shelf components and integrating these with heritage vacuum gauges.

Krug, Eric↗

Energy 101: Energy Efficient Data Centers

Data centers provide mission-critical computing functions vital to the daily operation of top U.S. economic, scientific, and technological organizations. These data centers consume large amounts of energy to run and maintain their computer systems, servers, and associated high-performance components—up to 3% of all U.S. electricity powers data centers. And as more information comes online, data centers will consume even more energy. Data centers can become more energy efficient by incorporating features like power-saving "stand-by" modes, energy monitoring software, and efficient cooling systems instead of energy-intensive air conditioners. These and other efficiency improvements to data centers can produce significant energy savings, reduce the load on the electric grid, and help protect the nation by increasing the reliability of critical computer operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-Sustainable IoT-Based Remote Sensing Powered by Energy Harvesting Using Stacked Piezoelectric Transducer and Thermoelectric Generator

We propose a self-powered remote multi-sensing system for traffic sensing which is powered by the collective energy harvested from the mechanical vibration of the road caused by the passing vehicles and from the temperature gradient between the asphalt of the road and the soil underneath. A stacked piezoelectric transducer converts mechanical vibrations into electrical energy and a thermoelectric generator harvests the thermal energy from the thermal gradient. Electrical energy signals from the stacked piezoelectric transducer and the thermoelectric generators are converted into usable DC power to recharge the battery using AC-DC and DC-DC converters working simultaneously. The multi-sensing system comprises an embedded system with a microcontroller that acquires data from the sensors and sends the sensory data to an IoT transceiver which transmits the data as RF packets to an ethernet gateway. The gateway converts the RF packets into Internet Protocol (IP) packets and sends them to a remote server. Laboratory and road-testing results showed over 98% sensory data accuracy with the system functioning solely powered by the energy harvested from the alternative energy sources. The successful maximum transmission distance obtained between the IoT, and the gateway was approximately 1 mile, which is a considerable transmission distance achieved in an urban environment. Successful operation of the self-powered multi-sensing system under both laboratory and road conditions contributes considerably to the fields of energy harvesting and self-powered remote sensing systems. The energy flow chart and efficiency for the steps in the system were found to be mechanical power from vehicles to the energy harvester of 0.25%, stacked PZT transducer efficiency was found to be 37%, and for the TEGs the efficiency is 11%. AC-to-DC and DC-to-DC converters’ efficiencies were found to be 90% and 11%. The wireless communication RF transceiver efficiency was found to be 62.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lazy Shadowing - An Adaptive, Power-Aware, Resiliency Framework for Extreme Scale Computing

The major goal of the project was to examine the problem of resilience in exascale systems via mechanisms that minimize the impact of server crashes resulting from both permanent faults and transient errors or subtle time-dependent bugs in hardware or software. Shadowing was proposed as the main technique for accomplishing this in the proposal, wherein some replicas of the application are run at much lower power and opportunistically speeded up during periods of low activity of the main or when the main fails. A related goal of the project was to detect the errors early so that program crashes could be avoided or the scope of the rollbacks could be limited.

97 MATHEMATICS AND COMPUTING↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗