Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity and Specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sooting tendencies of 20 bio-derived fuels for advanced spark-ignition engines

The sooting tendencies of 20 bio-derived fuels indicated as potential blendstocks for spark-ignition engines by the Co-Optimization of Fuels & Engines (Co-Optima) Initiative are studied. The Yield Sooting Index (YSI) is used to quantify the sooting tendencies. The Co-Optima Chemical Model is used to predict the numerical YSIs for all test fuels, and these results are compared with measurements. Experimental YSIs are newly measured for 2 furans and are taken from our previous work for the other compounds. Overall, the predicted YSIs agree well with measurements, within the experimental uncertainties, except for 2,5-dimethylfuran (2,5-DMF). It is found that Polycyclic Aromatic Hydrocarbons (PAH) growth reactions have little influence on the relative soot production from each fuel and therefore on YSI predictions. A modified sensitivity coefficient formulation is proposed to evaluate reaction sensitivities specifically for YSI. This formulation is applied to the 2,5-DMF-doped flame, and six 2,5-DMF initial decomposition reactions, which lead to different major soot precursors, are identified as the most sensitive reactions. The impact of the chemical kinetic uncertainties embedded in these reactions is quantified by randomly perturbing their reaction rates within a factor of two. The resulting prediction uncertainty in the 2,5-DMF-doped flame is found to be ± 8 YSI units (±11%), which demonstrates that the test-fuel-specific decomposition reactions indeed have considerable influence on its YSI prediction. Our research suggests that more accurate kinetic parameters for fuel initial decomposition reactions can potentially improve YSI predictions effectively, without altering the YSI predictions of other fuels with significantly different molecular structures.

09 BIOMASS FUELS↗

Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

Diskin, Glenn S.↗

An assessment of the safety, hemodynamic response, and diagnostic accuracy of commonly used vasodilator stressors in patients with severe aortic stenosis

Background: Increasing numbers of patients are undergoing transcatheter aortic valve replacement, which often involves assessment of coronary artery disease ischemic burden. The safety and diagnostic accuracy of vasodilator stress agents in patients with severe aortic stenosis (AS) undergoing SPECT myocardial perfusion imaging (MPI) has not been established. Methods: Patients with severe AS (valve area <1 cm{sup 2}) on echocardiography who underwent vasodilator stress SPECT MPI at two centers were identified. Patients with aortic valve intervention prior to MPI or who underwent concurrent exercise during stress testing were excluded. AS patients were matched to controls without AS based on age, gender, BMI, ejection fraction, and stress agent. Symptoms, serious adverse events, hemodynamic response, and correlation to invasive angiography were assessed. Results: A total of 95 cases were identified with 45% undergoing regadenoson, 31% dipyridamole, and 24% adenosine stress. A significant change in systolic blood pressure (BP), cases vs controls, was observed with adenosine [−17.9 ± 20.1 vs −2.6 ± 24.9 P = .03)], with a trend toward significance with regadenoson [−16.8 ± 20.3 vs −9.4 ± 17.9 (P = .08)] and dipyridamole [−17.8 ± 20.6 vs -9.0 ± 12.1 (P = .05)]. The change in heart rate was significantly different only for adenosine [5.3 ± 16.8 vs 14.2 ± 10.8 (P = .04)]. Overall, 45% of cases vs 24% of controls (P = .004) had a >20 mmHg decrease in systolic BP. Age, BMI, and resting systolic BP were related to a >20 mmHg decrease in systolic BP on univariate analysis, although only higher resting systolic BP was a predictor on multivariate analysis. In 33 patients who underwent angiography, the sensitivity, specificity, and diagnostic accuracy of vasodilator stress MPI was 77%, 69%, and 73%, respectively. No serious adverse events occurred in the severe AS patients. Conclusion: Severe AS patients are more likely to have a hemodynamically significant decrease in systolic BP with vasodilator stress. There were no serious adverse events in this severe AS cohort with good diagnostic performance of MPI compared to angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a Test for Invasive Breast Cancer Using X-ray Diffraction of Hair—Results of a Clinical Trial

Objective: To assess the performance of a test for breast cancer utilizing synchrotron x-ray diffraction analysis of scalp hair from women undergoing diagnostic radiology assessment. Design and Setting: A double-blinded clinical trial of women who attended diagnostic radiology clinics in Australia. Patients: 1796 women referred for diagnostic radiology, with no previous history of cancer. Main Outcome Measures: Sensitivity, specificity and accuracy of the hair test analysis compared to the gold standard of imaging followed by biopsy where indicated. Results: The hair-based assay had an overall accuracy of > 77% and a negative predictive value of 99%. For all women, the sensitivity of both mammography and X-ray diffraction alone was 64%, but when used together the sensitivity rose to 86%. The sensitivity of the hair test for women under the age of 70 was 74%. Conclusion: In this large population trial the association between the presence of breast cancer and an altered hair fiber X-ray diffraction pattern previously reported has been confirmed. It appears that mammography and X-ray diffraction of hair detect different populations of breast cancers, and are synergistic when used together.

60 APPLIED LIFE SCIENCES↗

Developing Highly Sensitive Micro-Biosensors for in-situ Monitoring Mercury and Chromium(IV) Contaminants by Genetically-evolving and Computer-designing Metal-binding Proteins

Mercury has been well known as an environmental pollutant to the environment and to cause serious effects on human health for several decades. To effectively control mercury pollution and reduce mercury damages, the sensitive determination of mercury is essential. Currently, many different types of sensor-based assays have been developed, while the whole-cell biosensor has been gaining increasingly attentions due to its easy reproducibility and the possibility to greatly reduce the cost. However, significant improvements on the specificity, sensitivity, stability and simplicity of the whole-cell biosensor are still needed prior to its eventual commercialization. Sponsored by US Department of Energy under the contract agreement DE-FG02-07ER64410, we applied the special synthetic biology and directed evolution strategies to improve the effectiveness and performance of whole-cell biosensors. We have constructed different whole-cell biosensors for the mercuric ion and methylmercury detection with metalloregulator MerR, fluorescent protein mCherry and organomercurial lyase MerB. By introducing the mercuric transporter MerT, we were able to increase the detection sensitivity of whole-cell biosensors by at least one fold. By introducing the bio-amplification genetic circuit based on the gene cascade expression system of $P_{RM-}cI$ from bacteriophage λ and Pm-XylS2 from Pseudomonas putida, we have increased the detection sensitivity of whole-cell biosensors by 1~2 folds in our tested conditions. With the directed evolution of MerR and subsequent high-throughput screening via color assay and microplate screening, we have dramatically increased the detection sensitivity by up to 10 folds at low concentration of mercury (II) of 1-10nM. Structural modeling and computational analysis of the mutated MerR showed that many mutations could cause the change of a loop to helix, which could be responsible for the increased mercury sensitivity.

02 PETROLEUM↗

Kinetic profiles of photocurrents in cells expressing two types of channelrhodopsin genes

Highlights: • Expression of an additional channelrhodopsin gene compensates ChR2 function. • Two channelrhodopsins can coexist in a cell without affecting their function. • Sensitivity to low light intensity is enhanced by expressing two channelrhodopsins. • Turning-ON and turning-OFF constants are prolonged in dual gene expression. Channelrhodopsin-2 (ChR2), a light-activated cation-selective ion channel, has been widely used as a tool in optogenetic research. ChR2 is specifically sensitive to wavelengths less than 550 nm. One of the methods to expand the sensitivity of a channelrhodopsin to a wider range of wavelengths is to express another channelrhodopsin in the cells by the transduction of an additional gene. Here, we report the characteristic features of cells expressing two types of channelrhodopsins, each having different wavelength sensitivities. In HEK293 cells stably expressing ChR2, photocurrents were elicited at stimuli of 400–550 nm, and the wavelength sensitivity range was expanded by the additional transduction of the modified Volvox channelrhodopsin-1 (mVChR1) gene, which has broad wavelength sensitivities, ranging from 400 to 600 nm. However, the photocurrent at 550 nm was lower than that of the mVChR1-expressing cell; moreover, the turning-on and turning-off constants were delayed, and the deactivation rates were decreased. Meanwhile, the response to lower light intensity was improved by the additional gene. Thus, the transduction of an additional gene is a useful method to improve the light and wavelength sensitivities, as well as photocurrent kinetic profiles, of channelrhodopsins.

60 APPLIED LIFE SCIENCES↗

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

End-User Perspectives on Using Quantitative Real-Time PCR and Genomic Sequencing in the Field

Quantitative real-time PCR and genomic sequencing have become mainstays for performing molecular detection of biological threat agents in the field. There are notional assessments of the benefits, disadvantages, and challenges that each of these technologies offers according to findings in the literature. However, direct comparison between these two technologies in the context of field-forward operations is lacking. Most market surveys, whether published in print form or provided online, are directed to product manufacturers who can address their respective specifications and operations. One method for comparing these technologies is surveying end-users who are best suited for discussing operational capabilities, as they have hands-on experience with state-of-the-art molecular detection platforms and protocols. These end-users include operators in military defense and first response, as well as various research scientists in the public sector such as government and service laboratories, private sector, and civil society such as academia and nonprofit organizations performing method development and executing these protocols in the field. Our objective was to initiate a survey specific to end-users and their feedback. We developed a questionnaire that asked respondents to (1) determine what technologies they currently use, (2) identify the settings where the technologies are used, whether lab-based or field-forward, and (3) rate the technologies according to a set list of criteria. Of particular interest are assessments of sensitivity, specificity, reproducibility, scalability, portability, and discovery power. This article summarizes the findings from the end-user perspective, highlighting technical and operational challenges.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding the Decreased Segmental Dynamics of Supported Thin Polymer Films Reported by Incoherent Neutron Scattering

Incoherent neutron scattering (INS) has commonly reported a suppression of segmental dynamics for supported thin polymer films as thickness is decreased, which is counter to expectations based on other measurement techniques such as ellipsometry and fluorescence. We utilized INS in order to measure the dynamics of thin films of comb polystyrene (PS) from 50 to 525 K. There is a significant suppression in dynamics as determined from the similar to 5 ns DebyeWaller factor, < u(2)>, as measured via INS for films as thick as 213 nm, while there is no change in the glass transition temperature (T-g) as determined by ellipsometry for films as thin as 20 nm. This poor correlation between T-g from ellipsometry and dynamics as measured by is attributed to contamination of nanosecond by incipient relaxation processes, differences in sensitivity to the postulated dynamically dead layer near the substrate due to the relative weighting of the distribution of dynamics between the two techniques, differences in the time scales probed, and possible decoupling between fast and slow dynamics under nanoconfinement. Moreover, these results suggest that branching of PS significantly increases the interactions with the substrate to suppress the dynamics. Both technique-specific sensitivity to time scales and its weighing of the average over the gradient in dynamic properties present at the interfaces are important to consider when qualitatively different phenomena are inferred from different measurements.

36 MATERIALS SCIENCE↗

A systematic review of validated suicide outcome classification in observational studies

Abstract Background Suicidal outcomes, including ideation, attempt, and completed suicide, are an important drug safety issue, though few epidemiological studies address the accuracy of suicidal outcome ascertainment. Our primary objective was to evaluate validated methods for suicidal outcome classification in electronic health care database studies. Methods We performed a systematic review of PubMed and EMBASE to identify studies that validated methods for suicidal outcome classification published 1 January 1990 to 15 March 2016. Abstracts and full texts were screened by two reviewers using prespecified criteria. Sensitivity, specificity, and predictive value for suicidal outcomes were extracted by two reviewers. Methods followed PRISMA-P guidelines, PROSPERO Protocol: 2016: CRD42016042794. Results We identified 2202 citations, of which 34 validated the accuracy of measuring suicidal outcomes using International Classification of Diseases (ICD) codes or algorithms, chart review or vital records. ICD E-codes (E950-9) for suicide attempt had 2–19% sensitivity, and 83–100% positive predictive value (PPV). ICD algorithms that included events with ‘uncertain’ intent had 4–70% PPV. The three best-performing algorithms had 74–92% PPV, with improved sensitivity compared with E-codes. Read code algorithms had 14–68% sensitivity and 0–56% PPV. Studies estimated 19–80% sensitivity for chart review, and 41–97% sensitivity and 100% PPV for vital records. Conclusions Pharmacoepidemiological studies measuring suicidal outcomes often use methodologies with poor sensitivity or predictive value or both, which may result in underestimation of associations between drugs and suicidal behaviour. Studies should validate outcomes or use a previously validated algorithm with high PPV and acceptable sensitivity in an appropriate population and data source.

Swain, Richard S.↗

Review, Evaluation, and Directions for Gene-Targeted Assembly for Ecological Analyses of Metagenomes

Shotgun metagenomics has greatly advanced our understanding of microbial communities over the last decade. Metagenomic analyses often include assembly and genome binning, computationally daunting tasks especially for big data from complex environments such as soil and sediments. In many studies, however, only a subset of genes and pathways involved in specific functions are of interest; thus, it is not necessary to attempt global assembly. In addition, methods that target genes can be computationally more efficient and produce more accurate assembly by leveraging rich databases, especially for those genes that are of broad interest such as those involved in biogeochemical cycles, biodegradation, and antibiotic resistance or used as phylogenetic markers. Here, we review six gene-targeted assemblers with unique algorithms for extracting and/or assembling targeted genes: Xander, MegaGTA, SAT-Assembler, HMM-GRASPx, GenSeed-HMM, and MEGAN. We tested these tools using two datasets with known genomes, a synthetic community of artificial reads derived from the genomes of 17 bacteria, shotgun sequence data from a mock community with 48 bacteria and 16 archaea genomes, and a large soil shotgun metagenomic dataset. We compared assemblies of a universal single copy gene (rplB) and two N cycle genes (nifH and nirK). We measured their computational efficiency, sensitivity, specificity, and chimera rate and found Xander and MegaGTA, which both use a probabilistic graph structure to model the genes, have the best overall performance with all three datasets, although MEGAN, a reference matching assembler, had better sensitivity with synthetic and mock community members chosen from its reference collection. Also, Xander and MegaGTA are the only tools that include post-assembly scripts tuned for common molecular ecology and diversity analyses. Additionally, we provide a mathematical model for estimating the probability of assembling targeted genes in a metagenome for estimating required sequencing depth.

59 BASIC BIOLOGICAL SCIENCES↗

Purification and characterization of lipopolysaccharides from six strains of non-O157 Shiga toxin-producing Escherichia coli

Certain Shiga toxin-producing Escherichia coli (STEC) are virulent human pathogens that are most often acquired through contaminated food. The United States Department of Agriculture, Food Safety and Inspection Service has declared several serogroups of STEC as adulterants in non-intact raw beef products. Hence, sensitive and specific tests for the detection of these STEC are a necessity for implementation in food safety programs. E. coli serogroups are identified by their respective O-antigen moiety on the lipopolysaccharide (LPS) macromolecule. We propose that the development of O-antigen-specific immunological assays can facilitate simple and rapid discriminatory detection of STEC in beef. However, the resources (antigens and antibodies) required for such development are not readily available. To overcome this, we extracted and characterized LPS and O-antigen from six STEC strains. Using hot phenol extraction, we isolated the LPS component from each strain and purified it using a series of steps to eliminate proteins, nucleic acids, and lipid A antigens. Antigens and crude LPS extracts were characterized using gel electrophoresis, immunoblotting, and modified Western blotting with commercially available antibodies, thus assessing the serogroup specificity and sensitivity of available ligands as well. The results indicate that, while many commercially available antibodies bind LPS, their activities and specificities are highly variable, and often not as specific as those required for serogroup discrimination. This variability could be minimized by the production of antibodies specific for the O-antigen. Additionally, the antigens generated from this study provide a source of characterized LPS and O-antigen standards for six serogroups of STEC.

59 BASIC BIOLOGICAL SCIENCES↗

Application of a transmission crystal x-ray spectrometer to moderate-intensity laser driven sources

In the pursuit of novel, laser-produced x-ray sources for medical imaging applications, appropriate instrumental diagnostics need to be developed concurrently. A type of transmission crystal spectroscopy has previously been demonstrated as a survey tool for sources produced by high-power and high-energy lasers. The present work demonstrates the extension of this method into the study of medium-intensity laser driven hard x-ray sources with a design that preserves resolving power while maintaining high sensitivity. Specifically, spectroscopic measurements of characteristic K{alpha} and K{beta} emissions were studied from Mo targets irradiated by a 100 fs, 200 mJ, Ti: sapphire laser with intensity of 10{sup 17} W/cm{sup 2} to 10{sup 18} W/cm{sup 2} per shot. Using a transmission curved crystal spectrometer and off-Rowland circle imaging, resolving powers (E/{Delta}E) of around 300 for Mo K{alpha}{sub 2} at 17.37 keV were obtained with an end-to-end spectrometer efficiency of (1.13 {+-} 0.10) x 10{sup -5}. This sensitivity is sufficient for registering x-ray lines with high signal to background from targets following irradiation by a single laser pulse, demonstrating the utility of this method in the study of the development of medium-intensity laser driven x-ray sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for new physics in top quark production in dilepton final states in proton-proton collisions at $\sqrt{s} = 13\,\text {TeV}$

A search for new physics in top quark production is performed in proton-proton collisions at $13\,\text {TeV} $ . The data set corresponds to an integrated luminosity of $35.9{\,\text {fb}^{-1}} $ collected in 2016 with the CMS detector. Events with two opposite-sign isolated leptons (electrons or muons), and $\mathrm{b}$ quark jets in the final state are selected. The search is sensitive to new physics in top quark pair production and in single top quark production in association with a $\mathrm{W}$ boson. No significant deviation from the standard model expectation is observed. Results are interpreted in the framework of effective field theory and constraints on the relevant effective couplings are set, one at a time, using a dedicated multivariate analysis. This analysis differs from previous searches for new physics in the top quark sector by explicitly separating $\mathrm{t}\mathrm{W}$ from $\mathrm{t}{\bar{\mathrm{t}}}$ events and exploiting the specific sensitivity of the $\mathrm{t}\mathrm{W}$ process to new physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Antarctic lake phytoplankton and bacteria from near‐surface waters exhibit high sensitivity to climate‐driven disturbance

Abstract The McMurdo Dry Valleys (MDVs), Antarctica, represent a cold, desert ecosystem poised on the threshold of melting and freezing water. The MDVs have experienced dramatic signs of climatic change, most notably a warm austral summer in 2001–2002 that caused widespread flooding, partial ice cover loss and lake level rise. To understand the impact of these climatic disturbances on lake microbial communities, we simulated lake level rise and ice‐cover loss by transplanting dialysis‐bagged communities from selected depths to other locations in the water column or to an open water perimeter moat. Bacteria and eukaryote communities residing in the surface waters (5 m) exhibited shifts in community composition when exposed to either disturbance, while microbial communities from below the surface were largely unaffected by the transplant. We also observed an accumulation of labile dissolved organic carbon in the transplanted surface communities. In addition, there were taxa‐specific sensitivities: cryptophytes and Actinobacteria were highly sensitive particularly to the moat transplant, while chlorophytes and several bacterial taxa increased in relative abundance or were unaffected. Our results reveal that future climate‐driven disturbances will likely undermine the stability and productivity of MDV lake phytoplankton and bacterial communities in the surface waters of this extreme environment.

54 ENVIRONMENTAL SCIENCES↗

Fragmentation of spherical radioactive heavy nuclei as a novel probe of transient effects in fission

Peripheral collisions with radioactive heavy-ion beams at relativistic energies are discussed as an innovative approach for probing the transient regime experienced by fissile systems evolving toward quasiequilibrium and thereby studying the viscous nature of nuclear matter. A dedicated experiment using the advanced technical installations of GSI, Darmstadt, made it possible to realize ideal conditions for the investigation of relaxation effects in a metastable well. Combined with a highly sensitive experimental signature, it provides a measure of the transient effects with respect to the flux over the fission barrier. Within a two-step reaction process, 45 proton-rich unstable spherical isotopes between At and Th produced by projectile-fragmentation of a stable {sup 238}U beam have been used as secondary projectiles which impinge on lead target nuclei. The fragmentation of the radioactive projectiles results in nearly spherical compound nuclei that span a wide range in excitation energy and fissility. The decay of these excited systems by fission is studied with a dedicated setup which, together with the inverse kinematics of the reaction, permits the detection of both fission products in coincidence and the determination of their atomic numbers with high resolution. The information on the nuclear charges of the two fragments is used to sort the data according to the initial excitation energy and fissility of the compound nucleus. The width of the fission-fragment nuclear charge distribution is shown to be specifically sensitive to presaddle transient effects and is used to establish a clock for the passage of the saddle point. The comparison of the experimental results with model calculations points to a fission delay tau{sub trans} of (3.3+-0.7)x10{sup -21} s for initially spherical compound nuclei, independent of excitation energy and fissility. This value suggests a nuclear dissipation strength beta at small deformation of (4.5+-0.5)x10{sup 21} s{sup -1}. The very specific combination of the physics and technical equipment exploited in this work sheds light on previous controversial conclusions, which were drawn without considering the influence of the initial conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved diagnosis of the number of stenosed coronary artery vessels by segmentation with scatter and photo-peak window data for attenuation correction in myocardial perfusion SPECT

Background: Attenuation correction using segmentation of scatter and photo-peak window data (SSPAC) enables an evaluation of the attenuation map in a patient-specific manner without additional radiation exposure. We compared the accuracy of SSPAC and non-corrected myocardial perfusion scintigraphy methods for diagnosing the number of stenosed coronary artery vessels. Methods and Results: We retrospectively reviewed the data from 183 consecutive patients who underwent {sup 99m}Tc-tetrofosmin stress/rest SPECT examination and a coronary angiography within 3 months. The MPS images were reconstructed with and without SSPAC attenuation correction. We examined the accuracy of the quantitative interpretation using summed differential score in the detection of coronary artery disease (CAD). The attenuation maps were successfully determined in 179 of 183 patients (98%). In terms of the vessel-based diagnostic ability, sensitivity, specificity, positive predictive and negative predictive values of the SSPAC and non-correction methods for diagnosing CAD in individual coronary territories were 77%*, 89%, 74%*, and 90%* vs 51%, 87%, 62%, and 82%, respectively (*P < .05). In 35 patients with multi-vessel CAD, those values were 78%*, 81%, 93%, and 55%* vs 49%, 81%, 89%, and 34%, respectively (*P < .05; AUC: 0.82 vs 0.62, P < .05). Conclusion: SSPAC-corrected SPECT myocardial perfusion images exhibit improved accuracy in the detection of the number of stenosed coronary artery vessels, even in patients with multi-vessel CAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Application Specific k eff Sensitivities to Existing and New Subcritical and Critical Experiments

Integral subcritical and critical experiments are essential in providing validation of computational codes which improve confidence in the predicted k eff results of specific applications. This work discusses the relevance of existing integral subcritical and critical experiments to applications far reaching across the nuclear complex. These applications include Travelling Wave Reactors (TWR), Kilopower Reactor Using Stirling Technology (KRUSTY), and plutonium reflected by tantalum. The primary goal of this work is to improve knowledge of energy-dependent cross-section sensitivities for specific applications, identify nuclear data gaps in existing experiments, enable an optimized design of new experiments to address these gaps, and design practical new experiments that could be executed at the National Criticality Experiments Research Center (NCERC) that have a high-value to these applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗