Technical Safety Requirements for the B695 Segment

This document contains Technical Safety Requirements (TSRs) for the Radioactive and Hazardous Waste Management (RHWM) Division's B695 Segment of the Decontamination and Waste Treatment Facility (DWTF) at Lawrence Livermore National Laboratory (LLNL). The TSRs constitute requirements regarding the safe operation of the B695 Segment. The TSRs are derived from the Documented Safety Analysis (DSA) for the B695 Segment (LLNL 2007). The analysis presented there determined that the B695 Segment is a low-chemical hazard, Hazard Category 3, nonreactor nuclear facility. The TSRs consist primarily of inventory limits as well as controls to preserve the underlying assumptions in the hazard analyses. Furthermore, appropriate commitments to safety programs are presented in the administrative controls section of the TSRs. The B695 Segment (B695 and the west portion of B696) is a waste treatment and storage facility located in the northeast quadrant of the LLNL main site. The approximate area and boundary of the B695 Segment are shown in the B695 Segment DSA. Activities typically conducted in the B695 Segment include container storage, lab-packing, repacking, overpacking, bulking, sampling, waste transfer, and waste treatment. B695 is used to store and treat radioactive, mixed, and hazardous waste, and it also contains equipment used in conjunction with waste processing operations to treat various liquid and solid wastes. The portion of the building called Building 696 Solid Waste Processing Area (SWPA), also referred to as B696S in this report, is used primarily to manage solid radioactive, mixed, and hazardous waste. Operations specific to the SWPA include sorting and segregating waste, lab-packing, sampling, and crushing empty drums that previously contained waste. Furthermore, a Waste Packaging Unit will be permitted to treat hazardous and mixed waste. RHWM generally processes LLW with no, or extremely low, concentrations of transuranics (i.e., much less than 100 nCi/g). Wastes processed often contain only depleted uranium and beta- and gamma-emitting nuclides, e.g., {sup 90}Sr, {sup 137}Cs, {sup 3}H. Chapter 5 of the DSA documents the derivation of TSRs and develops the operational limits that protect the safety envelope defined for this facility. The DSA is applicable to the handling of radioactive waste stored and treated in the B695 Segment. Section 5 of the TSR, Administrative Controls, contains those Administrative Controls necessary to ensure safe operation of the B695 Segment. A basis explanation for each of the requirements described in Section 5.5, Specific Administrative Controls is provided in Appendix B. The basis explanation does not constitute an additional requirement, but is intended as an expansion of the logic and reasoning behind development of the requirement. Programmatic Administrative Controls are addressed in Section 5.6. This introduction to the B695 Segment TSRs is not part of the TSR limits or conditions and contains no requirements related to B695 Segment operations or to the safety analyses in the DSA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coherent phasing of segmented mirrors

The technical issues associated with a coherently phased segmented mirror can be divided into two types. The first involves the issues of manufacturing the surface quality of the mirror segments themselves (coherent phasing of individual segments). The second involves assembly issues of initializing in 1 G and retaining in 0 G an aggregate segmented mirror (coherent phasing between individual segments). Using a rectangular coordinate system at the vertex of a mirror segment, the rigid body motions are the six translational and rotational degrees of freedom. A first cut primary mirror wavefront error budget is presented. For a minimum operational wavelength of 30 micrometers, the derived values from the budget are: segment surface quality (0.45 micrometers RMS), radius mismatch (50 PPM), segment piston error (1.3 micrometers, segment tip/tilt error (0.6 microrad). Either active or passive segmented mirrors can be addressed, but if the surface quality of the off-axis segment and the radius matching requirements can be passively met, then only segment alignment need be sensed and controlled during operation in orbit. For the active mirror case, dimensional stability of the mirror material during operation is a key factor in establishing the degree of active figure control required.

Jones, Peter A.↗

Quantum-Assisted Variational Segmentation for Image-to-Image Wildfire Detection Using Satellite Data

The quantum computing community has been searching for suitable applications to demonstrate the potential of near-term quantum devices. Quantum machine learning is a potential candidate, particularly using models that cannot be efficiently simulated with classical computers [1, 2]. This work focuses on a transition phase of quantum computers where the quantum machine learning model is still simulable classically but projected not to be simulable as the size of the model grows. Ultimately quantum computers may have advantages for high-dimensional real-world problems. Due to the limited number of qubits in current noisy intermediate-scale quantum (NISQ) devices, the direct application of quantum computers in high dimensional data is not feasible. To remedy this problem, an encoder-decoder architecture can be utilized. The encoder model would transform the high-dimensional data into a compact representation, to a level that small quantum computers can be used today (or in the near future), and the decoder would take the quantum processed outputs back to the high-dimensional space. Addressing the two challenges of quantum machine learning, this work investigates a hybrid supervised generative model with a quantum Ising Born machine embedded as the latent distribution. The model contains four main parts (Figure 1.a.): (1) a U-NET architecture responsible for learning segmentation flow, (2) a Prior network responsible for learning an encoded latent distribution of the input data, (3) a Born machine which represents the latent distribution, and (4) a Posterior network in charge of learning the joint encoded latent distribution of inputs and target data. The initial model, proposed by [3], is optimized by (1) maximizing the overlap of the prior and posterior latent distributions, and (2) minimizing the segmentation loss. The proposed model is designed to be investigated in a simulation environment applied to the real-world application of wildfire segmentation. Specifically, the model is designed to solve the patchy wildfire segmentations of Moderate Resolution Imaging Spectroradiometer (MODIS) by taking the MODIS observations and using Visible Infrared Imaging Radiometer Suite’s (VIIRS) consistent wildfire product as the target. The model solves patchy wildfire segmentations and provides insight into the epistemic errors sourced from model variation. The model utilizes the Born machine as a QUBO solver to represent the latent space as a Bernoulli distribution. The proposed configuration allows the variational segmentation model to leverage the true quantum probabilistic nature and derive a more expressive latent configuration, increasing the model performance in describing wildfire segmentations. The quantum probabilistic information of the Born machine is directly incorporated in the Kullback-Leibler divergence loss in the prior and posterior distributions, forcing the Bernoulli latent distribution to maximize the overlap of input and joint input-target distributions. The proposed model is then trained and compared with a baseline only consisting of direct Bernoulli latent distribution with no Born machine representing the latent space. The models are evaluated based on the segmentation metrics, such as precision, recall, intersect of union, with uncertainty boundaries accounting for the stochastic nature of the model. Our findings show that even in low latent-dimensional space (due to the limit in computational power of the classical quantum simulator), we are able to effectively capture the latent representation and hence the model performs better than the baseline. The findings are a projection for scaling the model into higher dimensional latent space with the Born machine surpassing the baseline performance. Figure 1. Sub-figure (a) demonstrates the architecture for the training phase. The model consists of a Prior and Posterior network that encode inputs and joint input-target data into compact representations, respectively. The Born machine represents the latent distribution, and the U-NET branch learns the segmentation patterns of the data. The stochasticity is introduced to the U-NET through its last layer to create meaningful but stochastic segmentations. Sub-figure (b) represents the inference phase where the model takes the stochastic behavior from the prior network and injects that into the U-NET. Each attempt of inference will generate different but similar segmentations from the same distribution of the wildfire event. REFERENCES [1] Coyle, B., Mills, D., Danos, V., & Kashefi, E. (2020). The Born supremacy: quantum advantage and training of an Ising Born machine. npj Quantum Information, 6(1), 1-11. [2] Liu, J. G., & Wang, L. (2018). Differentiable learning of quantum circuit born machines. Physical Review A, 98(6), 062324. [3] Kohl, S., Romera-Paredes, B., Meyer, C., De Fauw, J., Ledsam, J. R., Maier-Hein, K., ... & Ronneberger, O. (2018). A probabilistic u-net for segmentation of ambiguous images. Advances in neural information processing systems, 31.

quantum machine learning↗

Segmentation of pulmonary nodules in three-dimensional CT images by use of a spiral-scanning technique

Accurate segmentation of pulmonary nodules in computed tomography (CT) is an important and difficult task for computer-aided diagnosis of lung cancer. Therefore, the authors developed a novel automated method for accurate segmentation of nodules in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. To simplify nodule segmentation, the 3D VOI was transformed into a two-dimensional (2D) image by use of a key 'spiral-scanning' technique, in which a number of radial lines originating from the center of the VOI spirally scanned the VOI from the 'north pole' to the 'south pole'. The voxels scanned by the radial lines provided a transformed 2D image. Because the surface of a nodule in the 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified the segmentation method and enabled reliable segmentation results to be obtained. A dynamic programming technique was employed to delineate the 'optimal' outline of a nodule in the 2D image, which corresponded to the surface of the nodule in the 3D image. The optimal outline was then transformed back into 3D image space to provide the surface of the nodule. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric for evaluating the segmentation method. The database included two Lung Imaging Database Consortium (LIDC) data sets that contained 23 and 86 CT scans, respectively, with 23 and 73 nodules that were 3 mm or larger in diameter. For the two data sets, six and four radiologists manually delineated the outlines of the nodules as reference standards in a performance evaluation for nodule segmentation. The segmentation method was trained on the first and was tested on the second LIDC data sets. The mean overlap values were 66% and 64% for the nodules in the first and second LIDC data sets, respectively, which represented a higher performance level than those of two existing segmentation methods that were also evaluated by use of the LIDC data sets. The segmentation method provided relatively reliable results for pulmonary nodule segmentation and would be useful for lung cancer quantification, detection, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining segment generation with direct step-and-shoot optimization in intensity-modulated radiation therapy

A method for generating a sequence of intensity-modulated radiation therapy step-and-shoot plans with increasing number of segments is presented. The objectives are to generate high-quality plans with few, large and regular segments, and to make the planning process more intuitive. The proposed method combines segment generation with direct step-and-shoot optimization, where leaf positions and segment weights are optimized simultaneously. The segment generation is based on a column generation approach. The method is evaluated on a test suite consisting of five head-and-neck cases and five prostate cases, planned for delivery with an Elekta SLi accelerator. The adjustment of segment shapes by direct step-and-shoot optimization improves the plan quality compared to using fixed segment shapes. The improvement in plan quality when adding segments is larger for plans with few segments. Eventually, adding more segments contributes very little to the plan quality, but increases the plan complexity. Thus, the method provides a tool for controlling the number of segments and, indirectly, the delivery time. This can support the planner in finding a sound trade-off between plan quality and treatment complexity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for robust segmentation of arbitrarily shaped radiopaque structures in cone-beam CT projections

Purpose: Implanted markers are commonly used in radiotherapy for x-ray based target localization. The projected marker position in a series of cone-beam CT (CBCT) projections can be used to estimate the three dimensional (3D) target trajectory during the CBCT acquisition. This has important applications in tumor motion management such as motion inclusive, gating, and tumor tracking strategies. However, for irregularly shaped markers, reliable segmentation is challenged by large variations in the marker shape with projection angle. The purpose of this study was to develop a semiautomated method for robust and reliable segmentation of arbitrarily shaped radiopaque markers in CBCT projections. Methods: The segmentation method involved the following three steps: (1) Threshold based segmentation of the marker in three to six selected projections with large angular separation, good marker contrast, and uniform background; (2) construction of a 3D marker model by coalignment and backprojection of the threshold-based segmentations; and (3) construction of marker templates at all imaging angles by projection of the 3D model and use of these templates for template-based segmentation. The versatility of the segmentation method was demonstrated by segmentation of the following structures in the projections from two clinical CBCT scans: (1) Three linear fiducial markers (Visicoil) implanted in or near a lung tumor and (2) an artificial cardiac valve in a lung cancer patient. Results: Automatic marker segmentation was obtained in more than 99.9% of the cases. The segmentation failed in a few cases where the marker was either close to a structure of similar appearance or hidden behind a dense structure (data cable). Conclusions: A robust template-based method for segmentation of arbitrarily shaped radiopaque markers in CBCT projections was developed.

60 APPLIED LIFE SCIENCES↗

SU-E-T-592: Relationship Between Dose of Distribution and Area of Segment Fields Among Different Intensity-Modulated Radiotherapy Planning in Cervix Cancer

Purpose: In premise of uninfluenced to dose distribution of tumor target and organ at risk(OAR) in cervical cancer,area of segment fields was changed to increase efficacy and optimize treatment method by designing different plan of intensity modulated radiotherapy(IMRT). Methods: 12 cases of cervical cancer were confirmed in pathology and treated with step and shoot IMRT. Dose of PTV was 50Gy/25fractions. Every patient was designed 9 treatment plans of IMRT by Pinnacle 8.0m planning system,each plan was used with 9 beams of uniform distribution and fixing incidence direction(200°,240°,280°,320°,0°,40°,80°,120°and 160°respectively),and designed for delivery on Elekta Synergy linear accelerator. All plans were optimized with the direct machine parameter optimization(DMPO) algorithm using the same set of optimization objectives. Number of maximum segment field was defined at 80 and minimum MU in each segment was 5MU,and minimal segment area was 2*1cm{sup 2},2*2cm{sup 2},3*3cm{sup 2},4*4cm{sup 2},5*5cm{sup 2},6*6cm{sup 2},7*7cm{sup 2},8*8cm{sup 2}and 9*9cm{sup 2},respectively.Coverage,homogeneity and conformity of PTV,sparing of OAR, MU and number of segment were compared. Results: In this group, mean volume of PTV was 916.8±228.7 cm{sup 3}. Compared with the area of minimal segment field increased from 2*1cm{sup 2} to 9*9 cm{sup 2},the number of mean MU was decreased from 1405±170 to 490±47 and the number of segment field was reduced from 76±4 to 39±7 respectively(p<0.05). When the limit of minimal segment area was increased from 2*1cm{sup 2} to 7*7 cm{sup 2},dose distribution of PTV,OAR,CI,HI and V{sub 2} {sub 3} were not different (p>0.05),but when the minimal segment area was 8*8 cm{sup 2} and 9*9 cm{sup 2},they were changed compared with 7*7 cm{sup 2} and below(p<0.05). Conclusion: The minimal segment field of IMRT plan designed by Pinnacle 8.0m planning system in cervical carcinoma should be enlarge reasonably and minimal segment area of 7*7 cm{sup 2} was recommend.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-02: Automated Lung Segmentation Method Using Atlas-Based Sparse Shape Composition with a Shape Constrained Deformable Model

Purpose: To develop an automated lung segmentation method, which combines the atlas-based sparse shape composition with a shape constrained deformable model in thoracic CT for patients with compromised lung volumes. Methods: Ten thoracic computed tomography scans for patients with large lung tumors were collected and reference lung ROIs in each scan was manually segmented to assess the performance of the method. We propose an automated and robust framework for lung tissue segmentation by using single statistical atlas registration to initialize a robust deformable model in order to perform fine segmentation that includes compromised lung tissue. First, a statistical image atlas with sparse shape composition is constructed and employed to obtain an approximate estimation of lung volume. Next, a robust deformable model with shape prior is initialized from this estimation. Energy terms from ROI edge potential and interior ROI region based potential as well as the initial ROI are combined in this model for accurate and robust segmentation. Results: The proposed segmentation method is applied to segment right lung on three CT scans. The quantitative results of our segmentation method achieved mean dice score of (0.92–0.95), mean accuracy of (0.97,0.98), and mean relative error of (0.10,0.16) with 95% CI. The quantitative results of previously published RASM segmentation method achieved mean dice score of (0.74,0.96), mean accuracy of (0.66,0.98), and mean relative error of (0.04, 0.38) with 95% CI. The qualitative and quantitative comparisons show that our proposed method can achieve better segmentation accuracy with less variance compared with a robust active shape model method. Conclusion: The atlas-based segmentation approach achieved relatively high accuracy with less variance compared to RASM in the sample dataset and the proposed method will be useful in image analysis applications for lung nodule or lung cancer diagnosis and radiotherapy assessment in thoracic computed tomography.

60 APPLIED LIFE SCIENCES↗

Interactive lung segmentation in abnormal human and animal chest CT scans

Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling results can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in challenging chest CT images. Both systems do not require prior knowledge of the scans under consideration and work on a variety of scans.

60 APPLIED LIFE SCIENCES↗

Toward accurate tooth segmentation from computed tomography images using a hybrid level set model

Purpose: A three-dimensional (3D) model of the teeth provides important information for orthodontic diagnosis and treatment planning. Tooth segmentation is an essential step in generating the 3D digital model from computed tomography (CT) images. The aim of this study is to develop an accurate and efficient tooth segmentation method from CT images. Methods: The 3D dental CT volumetric images are segmented slice by slice in a two-dimensional (2D) transverse plane. The 2D segmentation is composed of a manual initialization step and an automatic slice by slice segmentation step. In the manual initialization step, the user manually picks a starting slice and selects a seed point for each tooth in this slice. In the automatic slice segmentation step, a developed hybrid level set model is applied to segment tooth contours from each slice. Tooth contour propagation strategy is employed to initialize the level set function automatically. Cone beam CT (CBCT) images of two subjects were used to tune the parameters. Images of 16 additional subjects were used to validate the performance of the method. Volume overlap metrics and surface distance metrics were adopted to assess the segmentation accuracy quantitatively. The volume overlap metrics were volume difference (VD, mm{sup 3}) and Dice similarity coefficient (DSC, %). The surface distance metrics were average symmetric surface distance (ASSD, mm), RMS (root mean square) symmetric surface distance (RMSSSD, mm), and maximum symmetric surface distance (MSSD, mm). Computation time was recorded to assess the efficiency. The performance of the proposed method has been compared with two state-of-the-art methods. Results: For the tested CBCT images, the VD, DSC, ASSD, RMSSSD, and MSSD for the incisor were 38.16 ± 12.94 mm{sup 3}, 88.82 ± 2.14%, 0.29 ± 0.03 mm, 0.32 ± 0.08 mm, and 1.25 ± 0.58 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the canine were 49.12 ± 9.33 mm{sup 3}, 91.57 ± 0.82%, 0.27 ± 0.02 mm, 0.28 ± 0.03 mm, and 1.06 ± 0.40 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the premolar were 37.95 ± 10.13 mm{sup 3}, 92.45 ± 2.29%, 0.29 ± 0.06 mm, 0.33 ± 0.10 mm, and 1.28 ± 0.72 mm, respectively; the VD, DSC, ASSD, RMSSSD, and MSSD for the molar were 52.38 ± 17.27 mm{sup 3}, 94.12 ± 1.38%, 0.30 ± 0.08 mm, 0.35 ± 0.17 mm, and 1.52 ± 0.75 mm, respectively. The computation time of the proposed method for segmenting CBCT images of one subject was 7.25 ± 0.73 min. Compared with two other methods, the proposed method achieves significant improvement in terms of accuracy. Conclusions: The presented tooth segmentation method can be used to segment tooth contours from CT images accurately and efficiently.

60 APPLIED LIFE SCIENCES↗

Validation of clinical acceptability of an atlas-based segmentation algorithm for the delineation of organs at risk in head and neck cancer

Purpose: The aim of this study was to assess whether clinically acceptable segmentations of organs at risk (OARs) in head and neck cancer can be obtained automatically and efficiently using the novel “similarity and truth estimation for propagated segmentations” (STEPS) compared to the traditional “simultaneous truth and performance level estimation” (STAPLE) algorithm. Methods: First, 6 OARs were contoured by 2 radiation oncologists in a dataset of 100 patients with head and neck cancer on planning computed tomography images. Each image in the dataset was then automatically segmented with STAPLE and STEPS using those manual contours. Dice similarity coefficient (DSC) was then used to compare the accuracy of these automatic methods. Second, in a blind experiment, three separate and distinct trained physicians graded manual and automatic segmentations into one of the following three grades: clinically acceptable as determined by universal delineation guidelines (grade A), reasonably acceptable for clinical practice upon manual editing (grade B), and not acceptable (grade C). Finally, STEPS segmentations graded B were selected and one of the physicians manually edited them to grade A. Editing time was recorded. Results: Significant improvements in DSC can be seen when using the STEPS algorithm on large structures such as the brainstem, spinal canal, and left/right parotid compared to the STAPLE algorithm (all p < 0.001). In addition, across all three trained physicians, manual and STEPS segmentation grades were not significantly different for the brainstem, spinal canal, parotid (right/left), and optic chiasm (all p > 0.100). In contrast, STEPS segmentation grades were lower for the eyes (p < 0.001). Across all OARs and all physicians, STEPS produced segmentations graded as well as manual contouring at a rate of 83%, giving a lower bound on this rate of 80% with 95% confidence. Reduction in manual interaction time was on average 61% and 93% when automatic segmentations did and did not, respectively, require manual editing. Conclusions: The STEPS algorithm showed better performance than the STAPLE algorithm in segmenting OARs for radiotherapy of the head and neck. It can automatically produce clinically acceptable segmentation of OARs, with results as relevant as manual contouring for the brainstem, spinal canal, the parotids (left/right), and optic chiasm. A substantial reduction in manual labor was achieved when using STEPS even when manual editing was necessary.

60 APPLIED LIFE SCIENCES↗

Automated segmentation of dental CBCT image with prior-guided sequential random forests

Purpose: Cone-beam computed tomography (CBCT) is an increasingly utilized imaging modality for the diagnosis and treatment planning of the patients with craniomaxillofacial (CMF) deformities. Accurate segmentation of CBCT image is an essential step to generate 3D models for the diagnosis and treatment planning of the patients with CMF deformities. However, due to the image artifacts caused by beam hardening, imaging noise, inhomogeneity, truncation, and maximal intercuspation, it is difficult to segment the CBCT. Methods: In this paper, the authors present a new automatic segmentation method to address these problems. Specifically, the authors first employ a majority voting method to estimate the initial segmentation probability maps of both mandible and maxilla based on multiple aligned expert-segmented CBCT images. These probability maps provide an important prior guidance for CBCT segmentation. The authors then extract both the appearance features from CBCTs and the context features from the initial probability maps to train the first-layer of random forest classifier that can select discriminative features for segmentation. Based on the first-layer of trained classifier, the probability maps are updated, which will be employed to further train the next layer of random forest classifier. By iteratively training the subsequent random forest classifier using both the original CBCT features and the updated segmentation probability maps, a sequence of classifiers can be derived for accurate segmentation of CBCT images. Results: Segmentation results on CBCTs of 30 subjects were both quantitatively and qualitatively validated based on manually labeled ground truth. The average Dice ratios of mandible and maxilla by the authors’ method were 0.94 and 0.91, respectively, which are significantly better than the state-of-the-art method based on sparse representation (p-value < 0.001). Conclusions: The authors have developed and validated a novel fully automated method for CBCT segmentation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Semiautomated segmentation of head and neck cancers in 18F-FDG PET scans: A just-enough-interaction approach

Purpose: The purpose of this work was to develop, validate, and compare a highly computer-aided method for the segmentation of hot lesions in head and neck 18F-FDG PET scans. Methods: A semiautomated segmentation method was developed, which transforms the segmentation problem into a graph-based optimization problem. For this purpose, a graph structure around a user-provided approximate lesion centerpoint is constructed and a suitable cost function is derived based on local image statistics. To handle frequently occurring situations that are ambiguous (e.g., lesions adjacent to each other versus lesion with inhomogeneous uptake), several segmentation modes are introduced that adapt the behavior of the base algorithm accordingly. In addition, the authors present approaches for the efficient interactive local and global refinement of initial segmentations that are based on the “just-enough-interaction” principle. For method validation, 60 PET/CT scans from 59 different subjects with 230 head and neck lesions were utilized. All patients had squamous cell carcinoma of the head and neck. A detailed comparison with the current clinically relevant standard manual segmentation approach was performed based on 2760 segmentations produced by three experts. Results: Segmentation accuracy measured by the Dice coefficient of the proposed semiautomated and standard manual segmentation approach was 0.766 and 0.764, respectively. This difference was not statistically significant (p = 0.2145). However, the intra- and interoperator standard deviations were significantly lower for the semiautomated method. In addition, the proposed method was found to be significantly faster and resulted in significantly higher intra- and interoperator segmentation agreement when compared to the manual segmentation approach. Conclusions: Lack of consistency in tumor definition is a critical barrier for radiation treatment targeting as well as for response assessment in clinical trials and in clinical oncology decision-making. The properties of the authors approach make it well suited for applications in image-guided radiation oncology, response assessment, or treatment outcome prediction.

60 APPLIED LIFE SCIENCES↗

TH-CD-206-02: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in MR Images Using Patch-Based Anatomical Signature

Purpose: MRI has shown promise in identifying prostate tumors with high sensitivity and specificity for the detection of prostate cancer. Accurate segmentation of the prostate plays a key role various tasks: to accurately localize prostate boundaries for biopsy needle placement and radiotherapy, to initialize multi-modal registration algorithms or to obtain the region of interest for computer-aided detection of prostate cancer. However, manual segmentation during biopsy or radiation therapy can be time consuming and subject to inter- and intra-observer variation. This study’s purpose it to develop an automated method to address this technical challenge. Methods: We present an automated multi-atlas segmentation for MR prostate segmentation using patch-based label fusion. After an initial preprocessing for all images, all the atlases are non-rigidly registered to a target image. And then, the resulting transformation is used to propagate the anatomical structure labels of the atlas into the space of the target image. The top L similar atlases are further chosen by measuring intensity and structure difference in the region of interest around prostate. Finally, using voxel weighting based on patch-based anatomical signature, the label that the majority of all warped labels predict for each voxel is used for the final segmentation of the target image. Results: This segmentation technique was validated with a clinical study of 13 patients. The accuracy of our approach was assessed using the manual segmentation (gold standard). The mean volume Dice Overlap Coefficient was 89.5±2.9% between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D MRI-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning label fusion framework, demonstrated its clinical feasibility, and validated its accuracy. This segmentation technique could be a useful tool in image-guided interventions for prostate-cancer diagnosis and treatment.

60 APPLIED LIFE SCIENCES↗

Space Adaptation of Active Mirror Segment Concepts

This report summarizes the results of a three year effort by Blue Line Engineering Co. to advance the state of segmented mirror systems in several separate but related areas. The initial set of tasks were designed to address the issues of system level architecture, digital processing system, cluster level support structures, and advanced mirror fabrication concepts. Later in the project new tasks were added to provide support to the existing segmented mirror testbed at Marshall Space Flight Center (MSFC) in the form of upgrades to the 36 subaperture wavefront sensor. Still later, tasks were added to build and install a new system processor based on the results of the new system architecture. The project was successful in achieving a number of important results. These include the following most notable accomplishments: 1) The creation of a new modular digital processing system that is extremely capable and may be applied to a wide range of segmented mirror systems as well as many classes of Multiple Input Multiple Output (MIMO) control systems such as active structures or industrial automation. 2) A new graphical user interface was created for operation of segmented mirror systems. 3) The development of a high bit rate serial data loop that permits bi-directional flow of data to and from as many as 39 segments daisy-chained to form a single cluster of segments. 4) Upgrade of the 36 subaperture Hartmann type Wave Front Sensor (WFS) of the Phased Array Mirror, Extendible Large Aperture (PAMELA) testbed at MSFC resulting in a 40 to 5OX improvement in SNR which in turn enabled NASA personnel to achieve many significant strides in improved closed-loop system operation in 1998. 5) A new system level processor was built and delivered to MSFC for use with the PAMELA testbed. This new system featured a new graphical user interface to replace the obsolete and non-supported menu system originally delivered with the PAMELA system. The hardware featured Blue Line's new stackable processing system which included fiber optic data links, a WFS digital interface, and a very compact and reliable electronics package. The project also resulted in substantial advances in the evolution of concepts for integrated structures to be used to support clusters of segments while also serving as the means to distribute power, timing, and data communications resources. A prototype cluster base was built and delivered that would support a small array of 7 cm mirror segments. Another conceptual design effort led to substantial progress in the area of laminated silicon mirror segments. While finished mirrors were never successfully produced in this exploratory effort, the basic feasibility of the concept was established through a significant amount of experimental development in microelectronics processing laboratories at the University of Colorado in Colorado Springs. Ultimately lightweighted aluminum mirrors with replicated front surfaces were produced and delivered as part of a separate contract to develop integrated segmented mirror assemblies. Overall the project was very successful in advancing segmented mirror system architectures on several fronts. In fact, the results of this work have already served as the basic foundation for the system architectures of several projects proposed by Blue Line for different missions and customers. These include the NMSD and AMSD procurements for NASA's Next Generation Space Telescope, the HET figure maintenance system, and the 1 meter FAST telescope project.

Ames, Gregory H.↗

Method of Adjusting Acoustic Impedances for Impedance-Tunable Acoustic Segments

A method is provided for making localized decisions and taking localized actions to achieve a global solution. In an embodiment of the present invention, acoustic impedances for impedance-tunable acoustic segments are adjusted. A first acoustic segment through an N-th acoustic segment are defined. To start the process, the first acoustic segment is designated as a leader and a noise-reducing impedance is determined therefor. This is accomplished using (i) one or more metrics associated with the acoustic wave at the leader, and (ii) the metric(s) associated with the acoustic wave at the N-th acoustic segment. The leader, the N-th acoustic segment, and each of the acoustic segments exclusive of the leader and the N-th acoustic segment, are tuned to the noise-reducing impedance. The current leader is then excluded from subsequent processing steps. The designation of leader is then given one of the remaining acoustic segments, and the process is repeated for each of the acoustic segments through an (N-1)-th one of the acoustic segments.

Jones, Kennie H↗

Reactor Vessel and Reactor Vessel Internals Segmentation at Zion Nuclear Power Station - 13230

Zion Nuclear Power Station (ZNPS) is a dual-unit Pressurized Water Reactor (PWR) nuclear power plant located on the Lake Michigan shoreline, in the city of Zion, Illinois approximately 64 km (40 miles) north of Chicago, Illinois and 67 km (42 miles) south of Milwaukee, Wisconsin. Each PWR is of the Westinghouse design and had a generation capacity of 1040 MW. Exelon Corporation operated both reactors with the first unit starting production of power in 1973 and the second unit coming on line in 1974. The operation of both reactors ceased in 1996/1997. In 2010 the Nuclear Regulatory Commission approved the transfer of Exelon Corporation's license to ZionSolutions, the Long Term Stewardship subsidiary of EnergySolutions responsible for the decommissioning of ZNPS. In October 2010, ZionSolutions awarded Siempelkamp Nuclear Services, Inc. (SNS) the contract to plan, segment, remove, and package both reactor vessels and their respective internals. This presentation discusses the tools employed by SNS to remove and segment the Reactor Vessel Internals (RVI) and Reactor Vessels (RV) and conveys the recent progress. SNS's mechanical segmentation tooling includes the C-HORCE (Circumferential Hydraulically Operated Cutting Equipment), BMT (Bolt Milling Tool), FaST (Former Attachment Severing Tool) and the VRS (Volume Reduction Station). Thermal segmentation of the reactor vessels will be accomplished using an Oxygen- Propane cutting system. The tools for internals segmentation were designed by SNS using their experience from other successful reactor and large component decommissioning and demolition (D and D) projects in the US. All of the designs allow for the mechanical segmentation of the internals remotely in the water-filled reactor cavities. The C-HORCE is designed to saw seven circumferential cuts through the Core Barrel and Thermal Shield walls with individual thicknesses up to 100 mm (4 inches). The BMT is designed to remove the bolts that fasten the Baffle Plates to the Baffle Former Plates. The FaST is designed to remove the Baffle Former Plates from the Core Barrel. The VRS further volume reduces segmented components using multiple configurations of the 38i and horizontal reciprocating saws. After the successful removal and volume reduction of the Internals, the RV will be segmented using a 'First in the US' thermal cutting process through a co-operative effort with Siempelkamp NIS Ingenieurgesellschaft mbH using their experience at the Stade NPP and Karlsruhe in Germany. SNS mobilized in the fall of 2011 to commence execution of the project in order to complete the RVI segmentation, removal and packaging activities for the first unit (Unit 2) by end of the 2012/beginning 2013 and then mobilize to the second unit, Unit 1. Parallel to the completion of the segmentation of the reactor vessel internals at Unit 1, SNS will segment the Unit 2 pressure vessel and at completion move to Unit 1. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adaptive Breast Radiation Therapy Using Modeling of Tissue Mechanics: A Breast Tissue Segmentation Study

Purpose: To validate and compare the accuracy of breast tissue segmentation methods applied to computed tomography (CT) scans used for radiation therapy planning and to study the effect of tissue distribution on the segmentation accuracy for the purpose of developing models for use in adaptive breast radiation therapy. Methods and Materials: Twenty-four patients receiving postlumpectomy radiation therapy for breast cancer underwent CT imaging in prone and supine positions. The whole-breast clinical target volume was outlined. Clinical target volumes were segmented into fibroglandular and fatty tissue using the following algorithms: physical density thresholding; interactive thresholding; fuzzy c-means with 3 classes (FCM3) and 4 classes (FCM4); and k-means. The segmentation algorithms were evaluated in 2 stages: first, an approach based on the assumption that the breast composition should be the same in both prone and supine position; and second, comparison of segmentation with tissue outlines from 3 experts using the Dice similarity coefficient (DSC). Breast datasets were grouped into nonsparse and sparse fibroglandular tissue distributions according to expert assessment and used to assess the accuracy of the segmentation methods and the agreement between experts. Results: Prone and supine breast composition analysis showed differences between the methods. Validation against expert outlines found significant differences (P<.001) between FCM3 and FCM4. Fuzzy c-means with 3 classes generated segmentation results (mean DSC = 0.70) closest to the experts' outlines. There was good agreement (mean DSC = 0.85) among experts for breast tissue outlining. Segmentation accuracy and expert agreement was significantly higher (P<.005) in the nonsparse group than in the sparse group. Conclusions: The FCM3 gave the most accurate segmentation of breast tissues on CT data and could therefore be used in adaptive radiation therapy-based on tissue modeling. Breast tissue segmentation methods should be used with caution in patients with sparse fibroglandular tissue distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗