Laboratory on the Moon: Equipping and Testing of a Habitat Laboratory for the Scientific Exploration of the Moon by Humans

A human habitat on the Moon is predestined to house a laboratory, especially if it is built for scientific missions on the Moon. This laboratory could be used for (1) conducting experiments utilizing the lunar gravity and prepare experiments to be placed outside the laboratory in the lunar environment, (2) conducting analyses of lunar rock and regolith in high volume, and (3) performing preliminary analyses and screening of samples to be sent to Earth for more detailed, specialized analysis. In the past, spaceflight missions have often been implemented by adding scientific instruments after most of the engineering work is already finished, limiting scientific studies to relatively scattered, insular topics. However, if prepared appropriately, a research laboratory on the Moon can help address scientific questions thoroughly and at a fundamental level. Moreover, the challenge of creating a viable habitat is not only an engineering one, but one that requires input from architects, designers, and psychologists. After all, the crew not only works inside the habitat laboratory, but they spend (close to) their entire time on the Moon inside the habitat and under the isolation and confinement that comes with it. We combine science, engineering, and architecture to create a habitat laboratory that meets their conflicting requirements: The laboratory of the Moon and Mars Base Analog (MaMBA) has been designed with inputs from (1) scientists of selected disciplines, particularly geology, materials science, chemistry, biology, and medicine, (2) space architects specializing on extraterrestrial bases, and (3) engineers for the constraints imposed by the lunar environment. The MaMBA laboratory was built in 2019 into the mock-up of the first MaMBA module (out of six). Subsequently, the laboratory was tested by volunteer scientists for its usability. The scientists used the laboratory for work deemed representative of lunar scientific analyses; the complete test runs lasted one week each, with one test run in June 2019 and the second test run in late September 2019 following some modifications suggested by the scientists. Here, we will present an overview of the scientific topics that we think should be addressed on the Moon, together with a suggestion of scientific instrumentation that would be helpful for such investigations. Moreover, we present the MaMBA laboratory, equipped with the proposed instrumentation, and the outcomes of the test runs with a particular focus on the lessons learned regarding the equipping of the laboratory.

Christiane Heinicke↗

Creep suppression and fatigue in bio-based composites manufactured via conventional and large format additive manufacturing processes

The emergence of novel extrusion-based additive manufacturing (AM) processes has prompted the development of new thermoplastic composite feedstocks, and broadening sustainability initiatives have driven the development of bio-based and recyclable material for AM feedstocks. Poly(lactic acid) (PLA) with wood flour (WF) is one composite system that has been demonstrated in numerous AM applications, as well as traditional processing methods (i.e., compression and injection molding); however, there has been a need to understand how the variation in processing methodology impacts the material performance of these bio-based feedstocks from a fundamental perspective, with particular emphasis on creep for an extended application use-life. Herein, PLA/WF is explored as a feedstock material for large format additive manufacturing (LFAM) and the performance of additively manufactured materials is compared to those produced via more traditional processing methods. It is also demonstrated that the addition of WF decreases the material’s coefficient of thermal expansion (CTE) while increasing its Young’s modulus, susceptibility to water uptake, and creep fatigue resistance. Essentially, the addition of 20 wt% WF results in a 92 % decrease in rubbery regime CTE while simultaneously resulting in a 14 % increase in modulus, 190 % increase in water uptake, and a 31 % decrease in residual strain after cyclic creep tests. The processing method was also found to play a large role in the final part performance, with the printed material increasing the crystallinity by 183 % and 214 % compared to its compression and injection molded counterparts. Furthermore, the porosity of printed samples increased by two orders of magnitude compared to samples prepared via traditional processing methods.

36 MATERIALS SCIENCE↗

Neutrons reveal the dynamics of leaf thylakoids in living plants

The study is the first known exploration of photosynthetic membranes dynamics in living plants by high resolution quasielastic neutron scattering spectroscopy. We investigated the mobility and flexibility of thylakoid membranes in common duckweed (Landoltia punctata) and identified dynamics across various length scales corresponding to individual membranes and membranes stack. We employed classical models typically used to study lipid bilayers to characterize the undulation modes and rigidity of the membranes and reveal how structural variations influence the observed complex dynamics. Our findings show that the stacks of thylakoids in duckweed behave as rigid systems, exhibiting an effective bending coefficient in the lower range associated with surfactant membranes. In contrast, the single thylakoid leaflets display greater apparent flexibility and are well situated within the bi-continuous surfactant phase dynamics. While our observations enhance the understanding of the intricate architecture and mobility of photosynthetic cellular machinery, they also highlight the limitations of applying ideal lipid membranes models to describe complex biological systems. This work opens more questions and the need for further investigations across extended length and time scales, as well as the importance of rigorous sample preparation and experimental control.

Applied physics↗

Lawrence Livermore National Laboratory Experimental Test Site 300 (Site 300): Site 300 Roadway Improvements - 836 Complex Soil Sampling and Analysis Plan (May 2023)

This Soil Sampling and Analysis Plan (SAP) was prepared by the Environmental Functional Area (EFA)/Technical Services Department (TSD) of the Environment, Safety & Health (ES&H) Directorate for the Project Management Office (PMO) for the proposed Roadway Improvements Project at the 836 Complex (project). The purpose of the SAP is to describe the procedures for collection and analysis of environmental samples and evaluation of analytical data (chemical and radiological) to determine management options of excavated soil during project construction. This SAP follows criteria established in Lawrence Livermore National Laboratory’s (LLNL) Soils Screening and Management Plan (SSMP) (LLNL 2022), which was formalized in accordance with U.S. Environmental Protection Agency (EPA) guidance for developing Data Quality Objectives for environmental data (EPA 2006) and the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) guidance (U.S. NRC, U.S. EPA, U.S. DOE, and U.S. DOD 2000). The scope of this SAP is based on preliminary design information provided by PMO.

54 ENVIRONMENTAL SCIENCES↗

LDEF space optics handbook

There is a need to present design guidelines derived from the Long Duration Exposure Facility (LDEF) space optics experiments to hardware designers. In response to this need a small study program was just started by SAIC and POD Associates for the Phillips Laboratory. The objective is to prepare a top-level review of available results on the behavior of certain optical components in the LDEF space experiments. The optics interest centers on optical surfaces and coatings, and fabrication processes for laser windows and mirrors. The program has two main parts: the first phase, to be completed by the end of 1992, consists of identifying and acquiring data from the appropriate investigators. The second phase, ending in December 1993, comprises report preparation as well as selected, prioritized, additional characterization of certain samples, coordinated with the principal investigators and the Phillips Laboratory. This program is getting under way at the time of the Symposium and does not warrant more than the present summary at this time.

Champetier, Robert J.↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

233 U(n,$\gamma$) measurements at LANSCE [Slides]

A new measurement at LANSCE combined DANCE and NEUANCE at the end of 2020 and 2021. The 233 U material was provided by Oak Ridge National Laboratory (December 2020).Two samples of 10 mg and 20 mg of 233 U have been prepared at LANL by Evelyn M. Bond (December 2020). The experiment was performed in December 2020 and June/July 2021. Data analysis is ongoing to extract capture data knowing fission. LANL is looking forward to delivering the capture/fission ratio from (1-300) keV by the end of the FY2022.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

233 U(n,$\gamma$) measurements at LANSCE [Slides]

A new measurement at LANSCE combined DANCE and NEUANCE at the end of 2020 and 2021. The 233 U material was provided by Oak Ridge National Laboratory (December 2020).Two samples of 10 mg and 20 mg of 233 U have been prepared at LANL by Evelyn M. Bond (December 2020). The experiment was performed in December 2020 and June/July 2021. Data analysis is ongoing to extract capture data knowing fission. LANL is looking forward to delivering the capture/fission ratio from (1-300) keV by the end of the FY2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash electropolishing for TEM: Reducing FIB‐induced defects in tungsten with protocols for new materials

Focused ion beam (FIB) milling has become the dominant approach for site-specific transmission electron microscopy (TEM) specimen preparation; however, FIB damage remains a critical limitation for reliable microstructural characterisation, particularly in radiation effects studies. Tungsten is especially susceptible to FIB damage due to its high nuclear stopping power, which promotes the formation and strong diffraction contrast of FIB-induced ‘black spot’ defects that are indistinguishable from very fine irradiation-induced loops/defects resulting from low to intermediate temperature neutron irradiation. In this work, flash electropolishing is systematically evaluated as a post-FIB treatment for minimising preparation-induced artefacts for TEM analysis of tungsten-based alloys. Using a range of non-, ion-, and neutron-irradiated tungsten materials, the effectiveness of flash electropolishing has been assessed through direct comparison with conventional FIB and plasma-FIB preparation including low-energy Ga, Ar, Xe ion cleaning. The results demonstrate that flash electropolishing effectively removes FIB-damaged layers and ‘black spot’ defects, thereby enabling reliable observation of irradiation-induced dislocation structures. Key processing parameters governing flash electropolishing quality – including lamella thickness, applied voltage, polishing duration, electrolyte chemistry, and cathode geometry – have been systematically evaluated, and clear criteria were established for determining when flash electropolishing is required to ensure reliable microstructural analysis. This work also provides practical guidance for implementing flash electropolishing as an artefact-controlled specimen-preparation approach for TEM characterisation of FIB-produced specimens. The systematic protocol can be extended to other, non-tungsten materials.

TEM sample preparation↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Lawrence Livermore National Laboratory Experimental Test Site 300 (Site 300): Site 300 Roadway Improvements - Chem Mag Loop Soil Sampling and Analysis Plan (May 2023)

This Soil Sampling and Analysis Plan (SAP) was prepared by the Environmental Function Area (EFA)/Technical Services Department (TSD) of the Environment, Safety & Health (ES&H) Directorate for the Project Management Office (PMO) for the proposed Roadway Improvements Project at the Chem Mag Loop (project). The purpose of the SAP is to describe the procedures for collection and analysis of environmental samples and evaluation of analytical data (chemical and radiological) to determine management options of excavated soil during project construction. This SAP follows criteria established in Lawrence Livermore National Laboratory’s (LLNL) Soils Screening and Management Plan (SSMP) (LLNL 2022), which was formalized in accordance with U.S. Environmental Protection Agency (EPA) guidance for developing Data Quality Objectives for environmental data (EPA 2006) and the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) guidance (U.S. NRC, U.S. EPA, U.S. DOE, and U.S. DOD 2000). The scope of this SAP is based on preliminary design information provided to EFA by PMO.

54 ENVIRONMENTAL SCIENCES↗

Electromagnetic Compatibility Test and Analysis Campaign of NASA's Mars 2020 Rover Final Submission

NASA's Mars 2020 Perseverance Rover—with a launch window opening July 2020, and landing expected February 2021—has mission objectives to look for evidence of habitability, seek biosignatures of past life, collect and cache samples for possible future return to Earth, and prepare for future human missions to Mars. The Rover platform is similar to the previous Mars Science Laboratory (MSL) “Curiosity” rover that landed in 2012 but contains a new suite of scientific instruments and upgrades to existing functionality: seven new and/or upgraded scientific payloads, an upgraded arm and sampling system, and a Helicopter demonstration. These changes—along with new efficiency goals to operate more Rover subsystems concurrently and thus collect more science—presented new electromagnetic compatibility (EMC) challenges. In this paper, we will describe the campaign to ensure Mars 2020 mission success from an electromagnetic environment perspective: 1) confirming existing MSL heritage subsystems and EMC requirements were compatible with the new Mars 2020 mission objectives, 2) engaging with engineers and scientists early in the project to identify and evaluate risks before hardware assembly and performing ambitious risk reduction tests, 3) undertaking a comprehensive subsystem qualification test program based on tailored MIL-STD-461F requirements, occasionally leading to redesign, 4) synthesizing the data collected to perform detailed analyses toward the goal of making risk-informed decisions at a system level. The spacecraft successfully completed all three planned system level tests, demonstrating self-compatibility with minimal impact to operations from electromagn

Gonzales, Edward C↗

Evaporation Rate Study and NDMA Formation from UDMH/NO2 Reaction Products

Laboratory samples of uns-dimethylhydrazine (UDMH) fuel/oxidizer (nitrogen dioxide) non-combustion reaction products (UFORP) were prepared using a unique permeation tube technology. Also, a synthetic UFORP was prepared from UDMH, N-nitrosodimethylamine (NDMA), dimethylammonium nitrate, sodium nitrite and purified water. The evaporation rate of UFORP and synthetic UFORP was determined under space vacuum (approx 10(exp -3) Torr) at -40 ?C and 0 ?C. The material remaining was analyzed and showed that the UFORP weight and NDMA concentration decreased over time; however, NDMA had not completely evaporated. Over 85% of the weight was removed by subjecting the UFORP to 10(-3) Torr for 7 hours at -40 ?C and 4 hours at 0 ?C. A mixture of dimethylammonium nitrate and sodium nitrite formed NDMA at a rapid rate in a moist air environment. A sample of UFORP residue was analyzed for formation of NDMA under various conditions. It was found that NDMA was not formed unless nitrite was added.

Buchanan, Vanessa D.↗

Ultrasonic Apparatus for Pulverizing Brittle Material

The figure depicts an apparatus that pulverizes brittle material by means of a combination of ultrasonic and sonic vibration, hammering, and abrasion. The basic design of the apparatus could be specialized to be a portable version for use by a geologist in collecting powdered rock samples for analysis in the field or in a laboratory. Alternatively, a larger benchtop version could be designed for milling and mixing of precursor powders for such purposes as synthesis of ceramic and other polycrystalline materials or preparing powder samples for x-ray diffraction or x-ray fluorescence measurements to determine crystalline structures and compositions. Among the most attractive characteristics of this apparatus are its light weight and the ability to function without need for a large preload or a large power supply: It has been estimated that a portable version could have a mass <0.5 kg, would consume less than 1 W h of energy in milling a 1-cm3 volume of rock, and could operate at a preload <10 N. The basic design and principle of operation of this apparatus are similar to those of other apparatuses described in a series of prior NASA Tech Briefs articles, the two most relevant being Ultrasonic/ Sonic Drill/Corers With Integrated Sensors (NPO-20856), Vol. 25, No. 1 (January 2001), page 38 and Ultrasonic/ Sonic Mechanisms for Deep Drilling and Coring (NPO-30291), Vol. 27, No. 9 (September 2003), page 65. As before, vibrations are excited by means of a piezoelectric actuator, an ultrasonic horn, and a mass that is free to move axially over a limited range. As before, the ultrasonic harmonic motion of the horn drives the free-mass in a combination of ultrasonic harmonic and lower-frequency hammering motion. In this case, the free-mass is confined within a hollow cylinder that serves as a crushing chamber, and the free-mass serves as a crushing or milling tool. The hammering of the free-mass against a material sample at the lower end of the chamber grinds the sample into powder in a relatively short time. The restriction of the free-mass to axial motion only makes the grinding very efficient. The free-mass can be fabricated to have teeth on its lower face to enhance the grinding effect. Optionally, there can be a hole at the bottom of the chamber covered with a sieve to tailor the size distribution of the powder leaving the crushing chamber.

Sherrit, Stewart↗

Sample Preparation Method for Low-Level Total 129 I Measurements by ICP-MS

Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Small Particulate Contamination Survey Of Genesis Flight Sample 61423

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind stop in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We continue to work with the community of scientists analyzing Genesis samples using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. We continue to evaluate the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping spacecraft and terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗