Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYSTEM FAILURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Failure detection system risk reduction assessment

A process includes determining a probability of a failure mode of a system being analyzed reaching a failure limit as a function of time to failure limit, determining a probability of a mitigation of the failure mode as a function of a time to failure limit, and quantifying a risk reduction based on the probability of the failure mode reaching the failure limit and the probability of the mitigation.

Aguilar, Robert B.↗

Test Results for the Automated Rendezvous and Capture System

The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.

Cruzen, Craig↗

Preliminary System Interface Failure Mode Analysis for Two Advanced Reactors

This study explores two distinct Balance of Plant (BOP) configurations: the Rankine cycle for a sodium-cooled fast reactor (SFR) and the Brayton cycle for a gas-cooled reactor (GCR). As representative designs, the Power Reactor Innovative Small Module (PRISM) by GE Hitachi Nuclear Energy was selected for the SFR, while the Gas Turbine Modular Helium Reactor (GT MHR) by General Atomics was chosen for the gas-cooled reactor. Both configurations were adapted to deliver high-quality heat for industrial applications. A Failure Modes and Effects Analysis (FMEA) was conducted for each system to identify critical failure modes affecting key components. This study marks the first phase of a two-step design optimization approach, integrating FMEA into the design process. Based on the analysis, design modifications and mitigation strategies were proposed to enhance system resilience. The second phase, to be detailed in a subsequent report, will focus on the role of the control system in mitigating these failures. The FMEA serves as a foundation for defining the control topology, ensuring system resilience against component failures that could compromise essential functions, such as electricity and heat production.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Testing of a failure accommodation system on a highly flexible grid

This paper presents a scheme for on-line failure detection in systems with appreciable structural dynamics. The design is suboptimal because of extensive computational requirements of optimal schemes. To accomplish failure detection, the innovations sequence of a finite order Kalman filter is examined. Because of the heavy dependence of the system on the zero-mean character of the innovations sequence of the filter much attention has been given to the design and evaluation of the Kalman filters used. The filter designs are based on modal models of the structural dynamics. Two modal models were considered, one based on an analytic finite element model and the other based on empirically derived frequency and damping. Experiments using a grid structure are presented which illustrate operation and performance of the filter designs based on these models. The general character of the results presented is that appreciable errors exist in the filter design based on the finite element model. Substantial improvement results if the design model is modified to include empirically derived frequency and damping.

Montgomery, R. C.↗

The System Complexity Metric (SCM) Predicts System Costs and Failure Rates

A complex system has many parts and interactions and so is difficult to understand. Systems with higher complexity generally have higher costs and failure rates. A System Complexity Metric (SCM) is defined to be the sum of the number of nodes, N, in the system block diagram plus the number of one-way interactions, I, between the nodes. SCM = N + I. SCMs are easily determined by direct inspection of high level block diagrams of life support systems. System cost was found to be directly proportional to SCM. The system MTBF (Mean Time Before Failure) is the inverse of the system failure rate. MTBF = 1/f. The system MTBF was found to be proportional to SCM^(-2.2) for estimated preflight MTBFs. As is typical for systems that are not extensively tested and redesigned to eliminate unexpected failure modes, the life support flight failure rates were about ten times higher than the preflight estimates and the MTBFs one-tenth the preflight estimates. The system MTBF was found to be proportional to SCM^(-2.6) for observed flight MTBFs.

System compleity↗

Common Cause Failures Dominate and Defeat Redundancy

Common cause failures occur when several malfunctions are produced by a single event or process. They are especially damaging when they eliminate an entire set of redundant systems and disable their intended function. Redundancy is used when the individual system failure probability is unacceptably high. Redundancy can improve the overall system failure probability if the failures are independent, but the reliability gain is limited if there are dependent failures having a common cause. No amount of redundancy can reduce the total failure probability below the common cause failure probability. Common cause failures defeat redundancy. Systems with high reliability requirements often use extensive redundancy. These highly redundant systems rarely fail unless all the redundant components providing a particular function fail. Complete failures of such highly redundant systems are then usually common cause failures. Common cause failures are prevalent in highly redundant, high reliability systems. Common cause failures dominate redundancy. Redundant systems may fail due to specification, design, manufacturing, operations, or maintenance problems that disable all the identical redundant systems. Common cause failures typically account for one tenth of all failures. If the failure probability is relatively low and common cause failures are significant, adding more than two or three redundant identical units usually gives little added reliability improvement. Common cause failures can be reduced by using diverse components with different technologies and manufacturers, by separating and shielding subsystems, and by avoiding shared control, power, or location. External events and shared vulnerabilities may still cause common cause failures.

common cause failures↗

Common Cause Failures Dominate and Defeat Redundancy

Common cause failures occur when several malfunctions are produced by a single event or process. They are especially damaging when they eliminate an entire set of redundant systems and disable their intended function. Redundancy is used when the individual system failure probability is unacceptably high. Redundancy can improve the overall system failure probability if the failures are independent, but the reliability gain is limited if there are dependent failures having a common cause. No amount of redundancy can reduce the total failure probability below the common cause failure probability. Common cause failures defeat redundancy. Systems with high reliability requirements often use extensive redundancy. These highly redundant systems rarely fail unless all the redundant components providing a particular function fail. Complete failures of such highly redundant systems are then usually common cause failures. Common cause failures are prevalent in highly redundant, high reliability systems. Common cause failures dominate redundancy. Redundant systems may fail due to specification, design, manufacturing, operations, or maintenance problems that disable all the identical redundant systems. Common cause failures typically account for one tenth of all failures. If the failure probability is relatively low and common cause failures are significant, adding more than two or three redundant identical units usually gives little added reliability improvement. Common cause failures can be reduced by using diverse components with different technologies and manufacturers, by separating and shielding subsystems, and by avoiding shared control, power, or location. External events and shared vulnerabilities may still cause common cause failures.

common cause failures↗

Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes ('Temperature Control' and 'Power Control') on Procedural Outcome

Purpose: This study was designed to analyze the effect of two different ablation modes ('temperature control' and 'power control') of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 {+-} 0 s in group I and 102 {+-} 21 s in group II. Long axis diameter was 20.3 {+-} 4.6 mm in group I and 19.8 {+-} 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 {+-} 2 mm in group I and 10.5 {+-} 2.4 mm in group II (NS). Circularity was 0.5 {+-} 0.1 in group I and 0.5 {+-} 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complex Failure Forewarning System - DHS Conference Proceedings

As the critical infrastructures of the United States have become more and more dependent on public and private networks, the potential for widespread national impact resulting from disruption or failure of these networks has also increased. Securing the nation s critical infrastructures requires protecting not only their physical systems but, just as important, the cyber portions of the systems on which they rely. A failure is inclusive of random events, design flaws, and instabilities caused by cyber (and/or physical) attack. One such domain, aging bridges, is used to explain the Complex Structure Failure Forewarning System. We discuss the workings of such a system in the context of the necessary sensors, command and control and data collection as well as the cyber security efforts that would support this system. Their application and the implications of this computing architecture are also discussed, with respect to our nation s aging infrastructure.

5th Annual University Network Summit↗

A latent fault Markov model for a highly reliable triplex computer system

A Markov model of a highly reliable triplex system was constructed to evaluate the probability of system failure as a function of the propagation of latent faults. It is found that if the propagation rate of latent faults is extremely high, they do not significantly affect the probability of system failure, while if the propagation rate is extremely low, the survivability of the system is improved. The propagation rate that is most harmful to the survivability of the system is determined as a function of the duration of the flight. A decrease in the probability of system failure due to latency is noted if the probability of any two faults giving the same output is extremely low.

Swern, Frederic L.↗

Sensor failure detection system

Advanced concepts for detecting, isolating, and accommodating sensor failures were studied to determine their applicability to the gas turbine control problem. Five concepts were formulated based upon such techniques as Kalman filters and a screening process led to the selection of one advanced concept for further evaluation. The selected advanced concept uses a Kalman filter to generate residuals, a weighted sum square residuals technique to detect soft failures, likelihood ratio testing of a bank of Kalman filters for isolation, and reconfiguring of the normal mode Kalman filter by eliminating the failed input to accommodate the failure. The advanced concept was compared to a baseline parameter synthesis technique. The advanced concept was shown to be a viable concept for detecting, isolating, and accommodating sensor failures for the gas turbine applications.

Beattie, E. C.↗

EUREX D: An expert system for failure diagnosis and recovery in the TCS of the European retrievable carrier EURECA

An expert system for diagnosis and recovery of failures in the Freon cooling loop of the European retrievable experiment carrier EURECA is described. The system demonstrates the feasibility of a functional scope of expert diagnostic systems which appears to be essential for practical applications of such systems in space technology. The scope includes early warning and treatment of incomplete information, fault tolerance, identification of failure superpositions, intelligent reaction to unforeseen events, and detailed status display for optimal recovery action.

Kellner, A.↗

Prognostic Relevance of Treatment Failure Patterns in Pediatric High-Grade Glioma: Is There a Role for a Revised Failure Classification System?

Purpose: We sought to investigate the pattern of treatment failure with respect to anatomic extent, radiation dose, and criteria for failure according to the Response Assessment in Neuro-Oncology (RANO). We evaluated the corresponding prognostic significance of these factors in patients with pediatric high-grade glioma (pHGG). Methods and Materials: Fifty-six patients with pHGG were enrolled in an institutional phase 1 to 2 prospective trial that included maximal safe resection and radiation therapy with concurrent and adjuvant erlotinib. The radiation therapy dose administered was 54 to 59.4 Gy at 1.8 Gy/d. Tumor progression was defined according to clinical symptoms and imaging features and was classified in relation to the original extent of the tumor, radiation prescription target volume coverage, and RANO criteria (RANOc). Results: With a median follow-up period of 90 months (range, 70-124 months), progression occurred in 48 patients (85.7%) while 8 (14.3%) were without progression. Central failure represented 42.6% of the total cohort, while in-field, marginal, and distant failures occurred in 7.4%, 9.3%, and 22.2%, respectively. Patients with biopsy or subtotal resection had increased rates of central failure and represented 14.81% and 16.67% of the total cohort, respectively. Tumor progression was classified as local, local plus distant, or distant. Among patients with local failure as a component of failure, 5 were considered to have marginal failure. Patients with frontal, temporal, and parietal disease had the highest rates of multifocal failure. A comparison between responses defined by RANOc demonstrated varied time to death (TTD) from progression. Conclusions: Pediatric high-grade glioma was shown to have high rates of central failure, particularly in cases with limited resection. Patients with central failure had a trend toward more prolonged TTD from failure relative to other failure patterns. The low marginal failure rates seen in this group suggest that less conservative radiation target margins may be possible. TTD from failure varied according to RANO type, suggesting that adult RANOc require modification before being applied to pHGG.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reinitialization issues in fault tolerant systems

This paper is concerned with the reinitialization of fault tolerant systems in which detection and isolation (FDI) techniques are used, on-line, to identify and compensate for system failures. Specifically, it will focus on FDI techniques which utilize analytic redundancy, arising from a knowledge of the plant dynamics, by analyzing the residuals of a no-fail filter designed on the assumption of no failures. In these types of fault tolerant systems, system failures have to propagate through the no-fail filter dynamics in order to get detected. Therefore, the no-fail filter must be reinitialized after the isolation of a failure so that the accumulated effects of the failure are removed. In this paper, various approaches to this reinitialization problem will be discussed.

Caglayan, A. K.↗

A failure diagnosis system based on a neural network classifier for the space shuttle main engine

A conceptual design of a model based failure detection and diagnosis system is developed for the space shuttle main engine. This design relies on the accurate and reliable identification of the parameters of the highly nonlinear and very complex engine. The design approach is presented in some detail and results for a failed valve are presented. These preliminary results verify that the developed parameter identification technique together with a neural network classifier can be used for this purpose.

Duyar, Ahmet↗

A failure diagnosis system based on a neural network classifier for the Space Shuttle Main Engine

A conceptual design of a model based failure deeteection and diagnosis system is deeveloped for the Space Shuttle Main Engine. This design relies on the accurate and reliable identification of the parameters of the highly nonlinear and very complex engine. The design approach is presented in some detail and results for a failed valve are presented. These preliminary results verify that the developed parameter identification technique, together with a neural network classifier, can be used for this purpose.

Duyar, Ahmet↗