Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electronic stopping power calculation for water under the Lindhard formalism for application in proton computed tomography

Because of the behavior that charged particles have when they interact with biological material, proton therapy is shaping the future of radiation therapy in cancer treatment. The planning of radiation therapy is made up of several stages. The first one is the diagnostic image, in which you have an idea of the density, size and type of tumor being treated; to understand this it is important to know how the particles beam interacts with the tissue. In this work, by using de Lindhard formalism and the Y.R. Waghmare model for the charge distribution of the proton, the electronic stopping power (SP) for a proton beam interacting with a liquid water target in the range of proton energies 10{sup 1} eV - 10{sup 10} eV taking into account all the charge states is calculated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving dynamic collision frequencies: Impacts on dynamic structure factors and stopping powers in warm dense matter

Simulations and diagnostics of high-energy-density plasmas and warm dense matter rely on models of material response properties, both static and dynamic (frequency-dependent). Here, in this work, we systematically investigate variations in dynamic electron–ion collision frequencies ν(ω) in warm dense matter using data from a self-consistent-field average-atom model. We show that including the full quantum density of states, strong collisions, and inelastic collisions lead to significant changes in ν(ω). These changes result in red shifts and broadening of the plasmon peak in the dynamic structure factor, an effect observable in x-ray Thomson scattering spectra, and modify stopping powers around the Bragg peak. These changes improve the agreement of computationally efficient average-atom models with first-principles time-dependent density functional theory in warm dense aluminum, carbon, and deuterium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-147: Monte Carlo Study of the Precision and Accuracy of Proton CT Reconstructed Relative Stopping Power Maps

Purpose: The quantification of the intrinsic performances of proton computed tomography (pCT) as a modality for treatment planning in proton therapy. The performance of an ideal pCT scanner is studied as a function of various parameters. Methods: Using GATE/Geant4, we simulated an ideal pCT scanner and scans of several cylindrical phantoms with various tissue equivalent inserts of different sizes. Insert materials were selected in order to be of clinical relevance. Tomographic images were reconstructed using a filtered backprojection algorithm taking into account the scattering of protons into the phantom. To quantify the performance of the ideal pCT scanner, we study the precision and the accuracy with respect to the theoretical relative stopping power ratios (RSP) values for different beam energies, imaging doses, insert sizes and detector positions. The planning range uncertainty resulting from the reconstructed RSP is also assessed by comparison with the range of the protons in the analytically simulated phantoms. Results: The results indicate that pCT can intrinsically achieve RSP resolution below 1%, for most examined tissues at beam energies below 300 MeV and for imaging doses around 1 mGy. RSP maps accuracy of less than 0.5 % is observed for most tissue types within the studied dose range (0.2–1.5 mGy). Finally, the uncertainty in the proton range due to the accuracy of the reconstructed RSP map is well below 1%. Conclusion: This work explores the intrinsic performance of pCT as an imaging modality for proton treatment planning. The obtained results show that under ideal conditions, 3D RSP maps can be reconstructed with an accuracy better than 1%. Hence, pCT is a promising candidate for reducing the range uncertainties introduced by the use of X-ray CT alongside with a semiempirical calibration to RSP.Supported by the DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗

Effects of alpha stopping power modelling on the ignition threshold in a directly-driven inertial confinement fusion capsule

The alpha-particle energy deposition mechanism modifies the ignition conditions of the thermonuclear Deuterium-Tritium fusion reactions, and constitutes a key issue in achieving high gain in Inertial Confinement Fusion implosions. One-dimensional hydrodynamic calculations have been performed with the code Multi-IFE to simulate the implosion of a capsule directly irradiated by a laser beam. The diffusion approximation for the alpha energy deposition has been used to optimize three laser profiles corresponding to different implosion velocities. A Monte-Carlo package has been included in Multi-IFE to calculate the alpha energy transport, and in this case the energy deposition uses both the LP and the BPS stopping power models. Homothetic transformations that maintain a constant implosion velocity have been used to map out the transition region between marginally-igniting and high-gain configurations. Furthermore, the results provided by the two models have been compared and it is found that – close to the ignition threshold – in order to produce the same fusion energy, the calculations performed with the BPS model require about 10% more invested energy with respect to the LP model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measured WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.

60 APPLIED LIFE SCIENCES↗

Mean excitation energies for stopping powers in various materials using local plasma oscillator strengths

The basic model of Lindhard and Scharff, known as the local plasma model, is used to study the effects on stopping power of the chemical and physical state of the medium. Unlike previous work with the local plasma model, in which individual electron shifts in the plasma frequency were estimated empirically, he Pines correction derived for a degenerate Fermi gas is shown herein to provide a reasonable estimate, even on the atomic scale. Thus, the model is moved to a complete theoretical base requiring no empirical adjustments, as characteristic of past applications. The principal remaining error is in the overestimation of the low-energy absorption properties that are characteristic of the plasma model in the region of the atomic discrete spectrum, although higher-energy phenomena are accurately represented, and even excitation-to-ionization ratios are given to fair accuracy. Mean excitation energies for covalent-bonded gases and solids, for ionic gases and crystals, and for metals are calculated using first-order models of the bonded states.

Wilson, J. W.↗

Mean excitation energies for stopping powers in various materials composed of elements hydrogen through argon

The local plasma model is used to study the effects of the chemical and physical state of a medium on its stopping power. The relationship between that model and a more exact quantum treatment of bound systems is elucidated by examining related quantities in both theories for the case of one and two-electron systems. Atomic mean excitation energies and straggling parameters in the local plasma model are compared with the accurate calculations of Inokuti et al. (1975, 1978, 1981). The use of the Gordon-Kim electron gas model of molecular bonding is used to determine the effects of covalent chemical bond shifts on the mean excitation energies for elements of the first two rows. Calculations of mean excitation energies of ionic bonded substances are presented, and the mean excitation energies of metals are discussed.

Wilson, J. W.↗

Low-energy proton stopping power of N2, O2 and water vapor and deviations from Bragg's rule

A modified local plasma model, based on the works of Lindhard and Winther; and Bethe, Brown, and Walske, is established. The Gordon-Kim model for molecular electron density is used to calculate stopping power of N2, O2, and water vapor for protons of energy ranging from 40 keV to 2.5 MeV, resulting in good agreement with experimental data. Deviations from Bragg's rule are evaluated and are discussed under the present theoretical model.

Xu, Y. J.↗

Stopping powers and cross sections due to two-photon processes in relativistic nucleus-nucleus collisions

The effects of electromagnetic-production processes due to two-photon exchange in nucleus-nucleus collisions are discussed. Feynman diagrams for two-photon exchange are evaluated using quantum electrodynamics. The total cross section and stopping power for projectile and target nuclei of identical charge are found to be significant for heavy nuclei above a few GeV per nucleon-incident energy.

Cheung, Wang K.↗

Atomic mean excitation energies for stopping powers from local plasma oscillator strengths

The stopping of a charged particle by isolated atoms is investigated theoretically using an 'atomic plasma' model in which atomic oscillator strengths are replaced by the plasma frequency spectrum. The plasma-frequency correction factor for individual electron motion proposed by Pines (1953) is incorporated, and atomic mean excitation energies are calculated for atoms through Sr. The results are compared in a graph with those obtained theoretically by Inokuti et al. (1978, 1981) and Dehmer et al. (1975) and with the experimental values compiled by Seltzer and Berger (1982): good agreement is shown.

Wilson, J. W.↗

Orientation-dependent stopping power of a degenerate electron gas for slow homonuclear dimers

We present a theoretical study on the orientation-dependent retarding force experienced by slow homonuclear dimers moving at arbitrary alignment with the direction of their flight in a three-dimensional degenerate electron gas of metallic densities. The analytical results are derived within the approximate framework of Brueckner for elastic scattering of an electron by a system of two auxiliary potentials of short range. The influence of the screened field of a single constituent of the slowly moving composite projectile on the scattering electron is modeled by an effective phase shift parameter {eta} in the short-range potential in order to characterize the real-constituent system coupling due to displacement. The orientation-dependent closed expressions reveal the dependence of observables on the classical geometry and quantum dynamics. The interplay of wave-interference and multiple scattering in the orientation-dependent friction is analyzed for realistic sets of the input parameters. Comparison with experimental data is made and good agreement is found.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-T-219: Verification of the Accuracy of a Relative Stopping Power (RSP) to Hounsfield Unit (HU) Calibration Curve Produced for Proton Treatment Planning Using EBT3-Gafchromic Film Dosimetry

Purpose: Accuracy of a RSP-HU calibration curve produced for proton treatment planning is tested by comparing the treatment planning system dose grid to physical doses delivered on film by a Mevion S250 double-scattering proton unit. Methods: A single batch of EBT3 Gafchromic film was used for calibration and measurements. The film calibration curve was obtained using Mevion proton beam reference option 20 (15cm range, 10cm modulation). Paired films were positioned at the center of the spread out Bragg peak (SOBP) in solid water. The calibration doses were verified with an ion chamber, including background and doses from 20cGy to 350cGy. Films were scanned in a flatbed Epson-Expression 10000-XL scanner, and analyzed using the red channel. A Rando phantom was scanned with a GE LightSpeed CT Simulator. A single-field proton plan (Eclipse, Varian) was calculated to deliver 171cGy to the pelvis section (heterogeneous region), using a standard 4×4cm aperture without compensator, 7.89cm beam range, and 5.36cm SOBP. Varied depths of the calculated distal 90% isodose-line were recorded and compared. The dose distribution from film irradiated between Rando slices was compared with the calculated plans using RIT v.6.2. Results: Distal 90% isodose-line depth variation between CT scans was 2mm on average, and 4mm at maximum. Fine calculation of this variation was restricted by the dose calculation grid, as well as the slice thickness. Dose differences between calibrated film measurements and calculated doses were on average 5.93cGy (3.5%), with the large majority of differences forming a normal distribution around 3.5cGy (2%). Calculated doses were almost entirely greater than those measured. Conclusion: RSP to HU calibration curve is shown to produce distal depth variation within the margin of tolerance (±4.3mm) across all potential scan energies and protocols. Dose distribution calculation is accurate to 2–4% within the SOBP, including areas of high tissue heterogeneity.

07 ISOTOPE AND RADIATION SOURCES↗

Collisional stopping power of ions in warm dense matter

Here, a model for the collisional stopping of ions on free electrons in warm dense matter is developed and explored. It is based on plasma kinetic theory, but with modifications to address the warm dense matter regime. Specifically, it uses the Boltzmann-Uehling-Uhlenbeck kinetic equation to incorporate effects of Fermi degeneracy of electrons. The cross section is computed from quantum scattering of electrons and ions occurring via the potential of mean force derived from an average atom model, which incorporates effects of strong Coulomb correlations. Predictions from this model show comparable accuracy to results from time-dependent density functional theory calculations for deuterium near solid density and a temperature of several electronvolts, at a fraction of the computational cost. Further, the model captures the transition of a plasma from the classical limit to the degenerate limit, including qualitative behaviors of solid state theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shell correction for the stopping power of K electrons

In view of the inapplicability of the asymptotic expressions for the stopping number available in the literature at high energies, an alternative approach is taken to compute the shell correction to the stopping number of K electrons. Anholt's formula for the K-shell ionization has been used to calculate the excitation function for longitudinal interaction and numerical integration over energy has been carried out to evaluate the shell correction. Comparison with other theoretical calculations is made. It is proposed that, with the inclusion of relativistic effects, an asymptotic expansion of the stopping number with a leading-term logarithmic in the energy of the incident particle would be more meaningful and might enable one to extract the relativistic contribution to the shell correction from it.

Leung, P. T.↗

Stopping power of neutrinos and antineutrinos in polymers

The Weinberg-Salam model is applied to quantify the energy loss of antineutrinos and neutrinos encountering polymers. The scattering cross-sectional energy due to encounters with electrons is calculated, along with the probability that an antineutrino will remain the same particle. The energy loss reaches a maximum, i.e., stopping occurs, when the probability is unity. The technique is applied to study the energy losses in kapton, a solid organic insulator used for antennas on spacecraft exposed to solar neutrinos with energies ranging from 0.5-10 MeV. The energy loss is found to be negligible.

Rustgi, M. L.↗

WDM-SP-25A: Development of a stopping power platform using secondary nuclear reactions in Warm Dense Matter (Director’s Post-Doc Shot Request) [Slides]

Motivation: Recent theoretical modeling at LANL has demonstrated that the ignition criteria is a strong function of the temperature of the DT ice that surrounds the hot spot [Daughton et al. PoP 2023]. Alpha heating of the DT shell can raise the ignition threshold. Critical to modeling the alpha-particle deposition in the shell is understanding charged particle stopping in warm dense matter.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗