Fatigue crack growth resistance of the austenitic stainless steel Alloy 709 at elevated temperatures
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Not provided.
Not provided.
Abstract not provided.
Highlights: • AISI 304 stainless steel was cold rolled under 3 cryogenic temperatures and room temperature, after annealing bulk nano/ultrafine grained material was obtained. • Microstructure of samples was studied by TEM, −120 °C rolled sample had an equiaxed microstructure. • Corrosion resistance of samples was studied by polarization curve, EIS, and Mott-Schottky plot, −120 °C rolled sample had the best corrosion performance. • The distinctive polarization curve of −120 °C rolled sample indicated its passive film had peculiar feature, the M-S plot showed its abnormal semiconductor character. - Abstract: AISI 304 metastable austenite stainless steel was cold rolled under cryogenic temperature and transformed into martensite completely, after reverse transformation by annealing, bulk nano/ultrafine grained material was obtained. The material’s microstructure was observed by TEM, and the corrosion resistance was studied by polarization curve, EIS, and Mott-Schottky plot. Results showed that samples cold rolled at −120 °C had an equiaxed microstructure and displayed the best corrosion performance. The distinctive polarization curve shape indicated that its passive film had a peculiar feature, and the M-S plot showed its abnormal semiconductor character. XPS measurements are used to directly characterize the composition of passive film formed on specimens. Heterogeneous microstructures might help with the improvement on corrosion resistance of the nano/ultrafine grained stainless steel.
Stainless steel is ubiquitous in our modern world, however it can become contaminated. This can endanger our health. The aim of our study is to disinfect stainless steel using Bacillus cereus as a model organism. Bacillus cereus is a microbe that is ubiquitous in nature, specifically soil. B. cereus is known to cause illness in humans. To prevent this, we propose to use a glycoconjugate solution (GS) for disinfection of stainless steel after it is contamination by B. cereus spores. In this study, two GS (9, 10) were tested for disinfection effectiveness on B. cereus spores on the surface of stainless steel foil (AISI-Series 200/300/400, THERMA-FOIL, Dayville, CT 0241). The disinfection rate of each GS was assessed by exposing the steel surface to B. cereus spores first and allowing them to settle for 24 hours. GS was used to treat the contaminated surface. The steel is washed and the resulting solution is plated on tryptic soy agar (TSA) plates. The GS with the fewest colony forming unit (CFU) formed on TSA is determined to be the most efficient during disinfection. Results show that both GS demonstrate a strong ability to disinfect B. cereus spores. Between the two, GS 9 shows the highest disinfection efficacy by killing approximately 99.5% of spores. This is a drastic improvement over the 0-20% disinfection of the control. Based on this we find that studied GS do have the capacity to act as a disinfectant on stainless steel.
Here, we will present recently peer-reviewed results to showcase the advanced multimodal imaging capabilities developed to study irradiated materials at the Pacific Northwest National Laboratory. Irradiated cladding samples selected to support the tritium science and technology program will be used as an example to demonstrate the multimodal imaging capabilities.
The AISI Type 420 stainless steels are commonly used to steam generators, mixer blades, etc. These stainless steels are most prone to pitting in dissolved Cl{sup −} containing environments. In this paper, the effect of tempering temperature on pitting corrosion resistance of AISI Type 420 stainless steels was studied. The AISI Type 420 stainless steels specimens were heat treated at the temperature of 1050°C for 1 hour to reach austenite stabilization and then quench in the oil. After that, the specimens were tempered at the temperature of 150, 250, 350 and 450°C for 30 minutes and then air cooled to the room temperature. The electrochemical potentiodynamic polarization test was conducted at 3.5% sodium chloride solution to evaluate corrosion rate and pitting corrosion behaviour. The Scanning Electron Microscope (SEM), Energy Dispersive X-Ray Spectroscopy (EDS) were used to evaluate the pitting corrosion product. The result have shown that highest pitting potential was found in the sample tempered at 250°C and corrosion pits were found to initiate preferentially around chromium carbides.
Abstract not provided.
Irradiation of austenitic stainless steels results in the formation of dislocation loops, stacking fault tetrahedral, Ni-Si clusters and radiation-induced segregation (RIS). Of these features, it is the formation of precipitates which is most likely to impact the mechanical integrity at high dose. Unlike dislocation loops and RIS, precipitates exhibit an incubation period that can extend from 10 to 46 dpa, above which the cluster composition changes and a separate phase, (G-phase) forms. Both neutron and heavy ion irradiation showed that these clusters develop slowly and continue to evolve beyond 100 dpa. Overall, this work shows that the irradiated microstructure features produced by heavy ion irradiation are remarkably comparable in nature to those produced by neutron irradiation at much lower dose rates. The use of a temperature shift to account for the higher damage rate in heavy ion irradiation results in a fairly good match in the dislocation loop microstructure and the precipitate microstructure in austenitic stainless steels. Both irradiations also show segregation of the same elements and in the same directions, but to achieve comparable magnitudes, heavy ion irradiation must be conducted at a much higher temperature than that which produces a match with loops and precipitates. First-principles modeling has confirmed that the formation of Ni-Si precipitates under irradiation is likely caused by supersaturation of solute to defect sinks caused by highly correlated diffusion of Ni and Si. Thus, the formation and evolution of Ni-Si precipitates at high dose in austenitic stainless steels containing Si is inevitable.
Stainless steel is used for variety of applications with different grades, alloys, filaments and powders. Additive manufacturing (AM) enables unique design features and refined microstructures. Performance testing on AM parts are needed as input to modeling and accelerated qualification processes. The objective of this work is to determine the effect of surface roughness on corrosion rate for from different manufacturers Preliminary evaluation shows that the 500-hour data set was scattered, and trend analysis are complex, while the 1000h and 1500h test results evaluation show more distinct trends.
Three 316L stainless steel materials are studied and reported upon; wrought, as-built additively manufactured (AM), and heat-treated AM material. The AM material was produced from the laser engineered net shaping (LENS) process. Macroscopic uniaxial compression stress-strain curves were obtained for all three materials. The curves were similar for the wrought and heat-treated AM materials but the as-built AM material demonstrated approximately 1.7 times greater flow stress at any given level of strain than the other two materials. Electron-backscatter diffraction analysis of the materials also showed that the microstructures of the three materials differed; with complex grain morphology for the as-built AM material. The mean grain size of each of the three materials also differed. Furthermore, the initial dislocation density was also measured with neutron diffraction and line-profile analysis for both wrought and as-built AM materials with the density in the AM material approximately 2.5 times greater.
Not provided.
Type 304H and 316H stainless steels are codified in the ASME Boiler and Pressure Vessel Code for Section III, Division 5, Class A construction for up to 1500F (816C) and 300,000 hours. Extension of the design lifetimes to 500,000 hours has been undertaken by various research projects and by the ASME Section III, Division 5 Code Committees. Due to a long-standing issue related to non-classical creep behavior on the use of the time to the onset of tertiary creep as one of the time-dependent allowable stress criteria, little progress was made in the extension of the time-dependent allowable stresses for Type 304H and 316H stainless steels. A recent effort by Dabrow and Nestell (Impact of Tertiary Creep on Time Dependent Allowable Stresses for Type 304H and 316H Stainless Steels, Report 0300-0003-RPT-001, MPR Associates, Alexandria, VA, 2020) has provided a rational method for the treatment of the highly variable data for the time to onset of tertiary creep. In this paper, the background formulas for determining the time-dependent allowable stress values of Type 304H and 316H stainless steels, as assembled from relevant project work, are presented. These updates and extensions are being recommended to the ASME Code committees for approval, and are subject to change upon feedback from ASME Section III Code committees.
A mixed Fe+CoO precursor was successfully utilized to synthesize a dense CoFe 2 O 4 spinel coating on the Crofer 22 APU interconnect via reactive sintering at 900°C for 2 h in air without the use of any reduction treatment. Both the uncoated and coated samples were subject to thermal oxidation at 850°C for 500 h in air. Phase constituents, microstructure, and area specific resistance (ASR) of the uncoated and coated samples before and after the oxidation testing were evaluated. The CoFe 2 O 4 layer effectively reduced the Cr 2 O 3 scale growth and lowered the scale ASR.