Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Public electric vehicle charging station utilization in the United States

The utilization of electric vehicle (EV) charging equipment is a key driver of charging station economics, but current trends and factors related to the utilization of public charging infrastructure in the United States are not well understood. This study analyzes EV charging data from 3,705 nationwide public Level 2 (L2) and direct current fast charging (DCFC) stations over 2.5 years (2019-2022), observing utilization patterns over time. Regression analysis is used to assess the relationships between station utilization and several contextual and environmental factors. We conclude that local EV adoption is a strong indicator of utilization; L2 station utilization decreases with the size of the local charging network, while DCFC stations are less affected; and increased charging power has a greater effect on utilization for DCFC stations than L2. This study fills a critical research gap by reporting updated public charging station utilization statistics and analysis for the U.S. market.

33 ADVANCED PROPULSION SYSTEMS↗

Status of the nuclear measurement stations for the process control of spent fuel reprocessing at AREVA NC/La Hague

Nuclear measurements are used at AREVA NC/La Hague for the monitoring of spent fuel reprocessing. The process control is based on gamma-ray spectroscopy, passive neutron counting and active neutron interrogation, and gamma transmission measurements. The main objectives are criticality and safety, online process monitoring, and the determination of the residual fissile mass and activities in the metallic waste remained after fuel shearing and dissolution (empty hulls, grids, end pieces), which are put in radioactive waste drums before compaction. The whole monitoring system is composed of eight measurement stations which will be described in this paper. The main measurement stations no. 1, 3 and 7 are needed for criticality control. Before fuel element shearing for dissolution, station no. 1 allows determining the burn-up of the irradiated fuel by gamma-ray spectroscopy with HP Ge (high purity germanium) detectors. The burn-up is correlated to the {sup 137}Cs and {sup 134}Cs gamma emission rates. The fuel maximal mass which can be loaded in one bucket of the dissolver is estimated from the lowest burn-up fraction of the fuel element. Station no. 3 is dedicated to the control of the correct fuel dissolution, which is performed with a {sup 137}Cs gamma ray measurement with a HP Ge detector. Station no. 7 allows estimating the residual fissile mass in the drums filled with the metallic residues, especially in the hulls, from passive neutron counting (spontaneous fission and alpha-n reactions) and active interrogation (fission prompt neutrons induced by a pulsed neutron generator) with proportional {sup 3}He detectors. The measurement stations have been validated for the reprocessing of Uranium Oxide (UOX) fuels with a burn-up rate up to 60 GWd/t. This paper presents a brief overview of the current status of the nuclear measurement stations. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

H2FIRST Reference Station Design Task

The goal of the H2FIRST Reference Station Design Task is to accelerate acceptance of hydrogen infrastructure build-out by exploring the advantages and disadvantages of various station designs. It is hoped that these reference designs will help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design. These designs enable quick assessment of the suitability of a particular site for a hydrogen station, and they drive interchangeability of parts and manufacturing scale by employing uniformly-sized components. The station configurations evaluated in this report are not all inclusive. It is not intent to promote any specific station configuration or exclude any designs, but rather provide a rigorous analysis of a subset of likely near-term station configurations.

08 HYDROGEN↗

Hydrogen Stations for Urban Sites

Additional fueling stations need to be constructed in the U.S. to enable the wide-spread adoption of fuel cell electric vehicles. A wide variety of private and public stakeholders are involved in the development of this hydrogen fueling infrastructure. Each stakeholder has particular needs in the station planning, development, and operation process that may include evaluation of potential sites and requirements, understanding the components in a typical system, and/or improving public acceptance of this technology. Publicly available templates of representative station designs can be used to meet many of these stakeholder needs. These 'Reference Stations' help reduce the cost and speed the deployment of hydrogen stations by providing a common baseline with which to start a design, enabling quick assessment of the suitability of a particular site for a hydrogen station, and identifying contributors to poor economics and research and development areas for certain station designs.

08 HYDROGEN↗

Analytic Framework for Optimal Sizing of Hydrogen Fueling Stations for Heavy Duty Vehicles at Ports (CRADA 512)

This CRADA presents the strategy that PNNL and Sandia National Laboratories (SNL) will take to support Seattle City Light (SCL) in properly sizing a hydrogen station for class 8 drayage trucks at the Port of Seattle (Port), as part of a coordinated plan of mixed uses for hydrogen. The proper sizing for the fueling station is unique from past experiences because it will be part of a coordinated plan for a multi-use scheme for the hydrogen, and not a stand-alone fueling station. The multiple use-streams, and their relative values, will impact all facets of station sizing and design, including fueling rates, storage technology and size, equipment selection, and safety considerations. The future deployment of this fueling station, and its proper sizing, is seen as a critical first step in the larger vision of utilizing hydrogen to address a range of issues for SCL and the Port. These include, but are not limited to, large scale fueling of medium duty (MD) and heavy duty (HD) vehicles to reduce emissions, support of adjacent light duty (LD) vehicles, support of critical port operation during extreme events (e.g. resiliency), mitigation of capital intensive electrical distribution system upgrades to support evolving port operations, a market resource that can be used by SCL to generate revenue, and support of planned future maritime operations that currently require heavy use of shipboard hydrogen. While the broader use of hydrogen by SCL and the Port is not the focus of this CRADA, how its use impacts the design of the initial vehicle fueling station, and the modular approach, are the central work. As such, this project will develop the framework and process for developing a modular station design that considers the broader range of coordinate uses of hydrogen as an energy resource.

08 HYDROGEN↗

Predicting demand for hydrogen station fueling

Full function hydrogen stations are a reality; fuel cell electric vehicle drivers can pull up to commercial fueling stations and receive 3–5 kg in less than 5 min, for an approximately 300-mile range. The demand for hydrogen is increasing, driven by an increase in the fueling of public and private fuel cell vehicles. This study describes the development and value of a model that simulates stochastic future demand at a hydrogen filling station. The predictive hydrogen demand model described in this article is trained from mathematical models constructed from actual hydrogen fill count, amount, and frequency data. Future fill probabilities inform the hour-by-hour demand profile and the station state of either “available, ready to fill” or “available, filling”. For example, a prediction for a station generally dispensing 5,000 kg a week on a Friday afternoon at 4 p.m. is 16 fills, totaling 48.7 kg, with a 0.52 proportion of time spent in “available, filling” state yielding 31 min of filling time. This is a first-of-its kind, published study on predicting future hydrogen demand by the time of day (e.g., hour-by-hour intervals) and day of week. This study can be used for hydrogen station requirements and operation and maintenance strategies and to assess the impact of demand variations and scenarios. Finally, this article presents the current status of hydrogen demand, the model development methods, a set of sample results. Discussion and conclusions concentrate on the value and use of the proposed model.

08 HYDROGEN↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

Effects of Different Types of Entrances on Natural Ventilation in a Subway Station

In this study, the natural ventilation of a horizontal entrance of a typical subway station is investigated based on numerical simulations and experiments. In addition, a renormalization group k-e model (RNG k-e model) is applied to compute both the internal and external airflow patterns. Computational fluid dynamics (CFD) simulations are validated based on the experimental results. Furthermore, a multiple variable regression model is employed to study how the different parameters affect the internal airflow rates of the subway station statistically, according to the experimental results. For this typical model, the parameter importance can be ranked as follows: (1) outdoor wind speed; (2) flow resistance of the subway station; (3) height of the wind catcher; and (4) length of the wind catcher. To understand the detailed pressure distribution of the horizontal entrance of the subway station with and without the wind catcher, 3D numerical simulations are conducted for different scenarios. We attempt to alter the size of the wind catcher (including the length and height) to study the characteristics of the pressure on the horizontal entrance of the subway station under outdoor wind-driven conditions. The pressure distributions for the entrance for different scenarios are compared and analyzed. Finally, the interactions between the internal and external flows are investigated by changing the resistance of the subway station. When the internal flow resistance is changed, the pressure coefficient (Cp) of the entrance is different as well. Hence, the Cp is not only affected by the outdoor environment, but is also influenced by the internal airflows.

CFD↗

Resilient design of recharging station networks for electric transportation vehicles

As societies shift to 'greener' means of transportation using electricity-driven vehicles one critical challenge we face is the creation of a robust and resilient infrastructure of recharging stations. A particular issue here is the optimal location of service stations. In this work, we consider the placement of battery replacing service station in a city network for which the normal traffic flow is known. For such known traffic flow, the service stations are placed such that the expected performance is maximized without changing the traffic flow. This is done for different scenarios in which roads, road junctions and service stations can fail with a given probability. To account for such failure probabilities, the previously developed facility interception model is extended. Results show that service station failures have a minimal impact on the performance following robust placement while road and road junction failures have larger impacts which are not mitigated easily by robust placement.

02 PETROLEUM↗

Detecting impacts of surface development near weather stations since 1895 in the San Joaquin Valley of California

Abstract Temperature readings observed at surface weather stations have been used for detecting changes in climate due to their long period of observations. The most common temperature metrics recorded are the daily maximum (TMax) and minimum (TMin) extremes. Unfortunately, influences besides background climate variations impact these measurements such as changes in (1) instruments, (2) location, (3) time of observation, and (4) the surrounding artifacts of human civilization (buildings, farms, streets, etc.) Quantifying (4) is difficult because the surrounding infrastructure, unique to each site, often changes slowly and variably and is thus resistant to general algorithms for adjustment. We explore a direct method of detecting this impact by comparing a single station that experienced significant development from 1895 to 2019, and especially since 1970, relative to several other stations with lesser degrees of such development (after adjustments for the (1) to (3) are applied). The target station is Fresno, California (metro population ~ 15,000 in 1900 and ~ 1 million in 2019) situated on the eastern side of the broad, flat San Joaquin Valley in which several other stations reside. A unique component of this study is the use of pentad (5-day averages) as the test metric. Results indicate that Fresno experienced + 0.4 °C decade −1 more nighttime warming (TMin) since 1970 than its neighbors—a time when population grew almost 300%. There was little difference seen in TMax trends between Fresno and non-Fresno stations since 1895 with TMax trends being near zero. A case is made for the use of TMax as the preferred climate metric relative to TMin for a variety of physical reasons. Additionally, temperatures measured at systematic times of the day (i.e., hourly) show promise as climate indicators as compared with TMax and especially TMin (and thus TAvg) due to several complicating factors involved with daily high and low measurements.

54 ENVIRONMENTAL SCIENCES↗

Mediastinal lymph node detection and station mapping on chest CT using spatial priors and random forest

Purpose: To develop an automated system for mediastinal lymph node detection and station mapping for chest CT. Methods: The contextual organs, trachea, lungs, and spine are first automatically identified to locate the region of interest (ROI) (mediastinum). The authors employ shape features derived from Hessian analysis, local object scale, and circular transformation that are computed per voxel in the ROI. Eight more anatomical structures are simultaneously segmented by multiatlas label fusion. Spatial priors are defined as the relative multidimensional distance vectors corresponding to each structure. Intensity, shape, and spatial prior features are integrated and parsed by a random forest classifier for lymph node detection. The detected candidates are then segmented by the following curve evolution process. Texture features are computed on the segmented lymph nodes and a support vector machine committee is used for final classification. For lymph node station labeling, based on the segmentation results of the above anatomical structures, the textual definitions of mediastinal lymph node map according to the International Association for the Study of Lung Cancer are converted into patient-specific color-coded CT image, where the lymph node station can be automatically assigned for each detected node. Results: The chest CT volumes from 70 patients with 316 enlarged mediastinal lymph nodes are used for validation. For lymph node detection, their system achieves 88% sensitivity at eight false positives per patient. For lymph node station labeling, 84.5% of lymph nodes are correctly assigned to their stations. Conclusions: Multiple-channel shape, intensity, and spatial prior features aggregated by a random forest classifier improve mediastinal lymph node detection on chest CT. Using the location information of segmented anatomic structures from the multiatlas formulation enables accurate identification of lymph node stations.

60 APPLIED LIFE SCIENCES↗

Reevaluation of air surveillance station siting

DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GMS Station SOH Monitoring Configuration Guide (V.1.2)

The GMS Station State-of-Health (SOH) monitoring capability provides the system controller the ability to view current SOH values and calculated statistics for stations and channels, view trend plots of SOH values, be notified when station SOH status changes, and acknowledge or quiet notifications while the station issues are being investigated. The SOH monitoring capability includes components to acquire CD 1.1 protocol station data, extract SOH information from the raw data packets, process the raw SOH information for display, store the SOH information, and display the SOH information in an interactive display. All these components use system and processing configuration to provide the system controller mission-relevant information about station health. This document is a guide to setting the processing configuration for GMS SOH monitoring.

97 MATHEMATICS AND COMPUTING↗

A mechanistic model of a PWR-based nuclear power plant in response to external hazard-induced station blackout accidents

Natural hazard-induced nuclear accidents, such as the Fukushima Daiichi Accident that occurred in Japan in 2011, have significantly increased reactor safety studies in understanding nuclear power plant (NPP) responses to external hazard events such as earthquakes and floods. Natural hazards could cause the loss of offsite power in nuclear power plants, potentially leading to a Station Blackout (SBO) accident that significantly contributes to the overall risk of nuclear power plant accidents. Despite the fact that extensive research has been conducted on the station blackout accident for nuclear power plant, further understanding of these events is needed, particularly in the context of the dynamic nature of external hazards such as external flooding. This paper estimates the progression of station blackout events for a generic pressurized water reactor (PWR) in response to external flooding events. The original RELAP5-3D model of the Westinghouse four-loop design pressurized water reactor was adopted and modified to simulate the external flood-induced station blackout accident, including the short-term and long-term station blackout scenarios. A sensitivity analysis of long-term station blackout, examining reactor operation times and analyzing key parameters over time, was also conducted in this work. The results of the analyses, especially the critical timing parameters of key event sequences, provide useful insights about the time during the external flooding event, which is important for plant operators to make timely decisions to prevent potential core damage. This paper represents significant progress toward developing an integrated risk assessment framework for further identifying and assessing the effects of the critical sources of uncertainties of nuclear power plant under external hazard-induced events.

Liu, Tao↗

EarthScope Seismic Station A21K (A21K-6) Field Campaign Report

Seismic station A21K has been successfully operating over the last five years. The station was constructed on 4/24/2014 by creating a borehole using an auger drill and inserting a PVC pipe casing. Roughly one month later, on 6/2/2014, the seismometer, weather station (Vaisala WXT520 meteorological sensor), enclosure, and electronics were installed. Collected data is being reported in real-time and is publicly available. On rare occasion, the station has required in-person service/maintenance visits, occurring on 4/29/2015 (fix faulty cable), 4/5/2016 (swap VIE), and 8/4/2017 (general check-up visit while in the area). This station is one in a 280-station seismic array/grid that make up the EarthScope: Transportable Array (USArray) project, funded by the National Science Foundation. USArray is operated by the Incorporated Research Institutions for Seismology (IRIS), a nonprofit 503(c) Corporation founded in 1984, that is a consortium of over 100 US universities dedicated to the operation of science facilities for the acquisition, management, and distribution of seismological data.

North Slope of Alaska, seismology, Earth system↗

Multipurpose epithermal neutron beam on new research station at MARIA research reactor in Swierk-Poland

MARIA reactor is an open-pool research reactor what gives the chance to install uranium fission converter on the periphery of the core. It could be installed far enough not to induce reactivity of the core but close enough to produce high flux of fast neutrons. Special design of the converter is now under construction. It is planned to set the research stand based on such uranium converter in the near future: in 2015 MARIA reactor infrastructure should be ready (preparation started in 2013), in 2016 the neutron beam starts and in 2017 opening the stand for material and biological research or for medical training concerning BNCT. Unused for many years, horizontal channel number H2 at MARIA research rector in Poland, is going to be prepared as a part of unique stand. The characteristics of the neutron beam will be significant advantage of the facility. High flux of neutrons at the level of 2x10{sup 9} cm{sup -2}s{sup -1} will be obtainable by uranium neutron converter located 90 cm far from the reactor core fuel elements (still inside reactor core basket between so called core reflectors). Due to reaction of core neutrons with converter U{sub 3}Si{sub 2} material it will produce high flux of fast neutrons. After conversion neutrons will be collimated and moderated in the channel by special set of filters and moderators. At the end of H2 channel i.e. at the entrance to the research room neutron energy will be in the epithermal energy range with neutron intensity at least at the level required for BNCT (2x10{sup 9} cm{sup -2}s{sup -1}). For other purposes density of the neutron flux could be smaller. The possibility to change type and amount of installed filters/moderators which enables getting different properties of the beam (neutron energy spectrum, neutron-gamma ratio and beam profile and shape) is taken into account. H2 channel is located in separate room which is adjacent to two other empty rooms under the preparation for research laboratories (200 m2). It is planned to create fully equipped complex facility possible to perform various experiments on the intensive neutron beam. Epithermal neutron beam enables development across the full spectrum of materials research for example shielding concrete tests or electronic devices construction improvement. Due to recent reports on the construction of the accelerator for the Boron Neutron Capture Therapy (BNCT) it has the opportunity to become useful and successful method in the fight against brain and other types of cancers not treated with well known medical methods. In Europe there is no such epithermal neutron source which could be used throughout the year for training and research for scientist working on BNCT what makes the stand unique in Europe. Also our research group which specializes in mixed radiation dosimetry around nuclear and medical facilities would be able to carry out research on new detectors and methods of measurements for radiological protection and in-beam (therapeutic) dosimetry. Another group of scientists from National Centre for Nuclear Research, where MARIA research reactor is located, is involved in research of gamma detector systems. There is an idea to develop Prompt-gamma Single Photon Emission Computed Tomography (Pg- SPECT). This method could be used as imaging system for compounds emitting gamma rays after nuclear reaction with thermal neutrons e.g. for boron concentration in BNCT. Inside the room, where H2 channel is located, there is another horizontal channel - H1 which is also unused. Simultaneously with the construction of the H2 stand it will be possible to create special pneumatic horizontal mail inside the H1 channel for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. It might expand the scope of research at the planned neutron station. Secondly it is planned to equip both stands with moveable positioning system, video system and facilities to perform animal experiments (anaesthesia, vital signs control, imaging devices, positioning). These all above make constructed station unique in the world (uranium fission converter-based beam) and the only one of such intense neutron beam in the Europe. Moreover implementation of the station would allow the development of research on a number of issues for researchers from all over the Europe. One of very important advantages of the station is undisturbed exploitation of the reactor and other vertical and horizontal channels. MARIA reactor operates 6000 hours per year and that amount of time will be achievable for research on the neutron station. It have to be underlined that new neutron station will work parallel to all another ventures. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The criticality incident detection system omission cases for the fuel routes at EDF energy power stations - 14280

Criticality safety cases have been produced to justify the omission of criticality alarms from the fuel routes of EDF Energy's UK power stations. This work has addressed the UK regulator's expectations that adequate criticality warning systems should be provided wherever fissile material is present, unless a safety case shows that no criticality excursion could give any individual a whole body dose exceeding the annual whole body dose limit of 20 mSv, or that the predicted frequency of such excursions is acceptably low. In the UK, EDF Energy operates eight nuclear power stations; one Pressurized Water Reactor (PWR) and seven Advanced Gas-cooled Reactor stations (AGRs). At these stations, the term 'fuel route' is used to encompass all of the ex-reactor arrangements for the handling and storage of both new fuel and discharged irradiated fuel. These fuel routes were all designed in the 1980's (or earlier), using sound deterministic criticality safety principles, from which it was concluded that criticality alarms were not required in any of these areas. Subsequent changes to UK regulations have resulted in the need for the stations' criticality safety cases to be updated to include formal justifications for the omission of criticality alarms from these fuel routes. The EDF Energy Criticality Incident Detection System (CIDS) omission cases have been produced using the principles originally developed for UKAEA in the early 1960's by Aspinall and Daniels. These principles continue to be regarded as a best-practice approach by UK industry. Modern UK regulations also incorporate the ALARP principle, which requires operators to minimize and balance all of the safety risks from power station operations, so that the risks to both the public and to workers are As Low As is Reasonably Practicable. This paper describes how the work undertaken used the so-called Aspinall and Daniels criteria in conjunction with the requirements of the ALARP principle. The fuel storage pond at the Sizewell B PWR was addressed by dose calculations to show that, from the shielding effects of the concrete structure and the pond water, the potential consequences of a criticality accident could not result in a radiation dose in excess of 20 mSv. All of the other fuel route areas were addressed on the basis that, even if all of the active engineered and administrative criticality controls were to fail, a criticality accident would still not be reasonably expected, i.e. the predicted frequencies of all such excursions are acceptably low. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗