Integrated System Health Management: Pilot Operational Implementation in a Rocket Engine Test Stand

This paper describes a credible implementation of integrated system health management (ISHM) capability, as a pilot operational system. Important core elements that make possible fielding and evolution of ISHM capability have been validated in a rocket engine test stand, encompassing all phases of operation: stand-by, pre-test, test, and post-test. The core elements include an architecture (hardware/software) for ISHM, gateways for streaming real-time data from the data acquisition system into the ISHM system, automated configuration management employing transducer electronic data sheets (TEDS?s) adhering to the IEEE 1451.4 Standard for Smart Sensors and Actuators, broadcasting and capture of sensor measurements and health information adhering to the IEEE 1451.1 Standard for Smart Sensors and Actuators, user interfaces for management of redlines/bluelines, and establishment of a health assessment database system (HADS) and browser for extensive post-test analysis. The ISHM system was installed in the Test Control Room, where test operators were exposed to the capability. All functionalities of the pilot implementation were validated during testing and in post-test data streaming through the ISHM system. The implementation enabled significant improvements in awareness about the status of the test stand, and events and their causes/consequences. The architecture and software elements embody a systems engineering, knowledge-based approach; in conjunction with object-oriented environments. These qualities are permitting systematic augmentation of the capability and scaling to encompass other subsystems.

Figueroa, Fernando↗

Presyncopal/Non-Presyncopal Outcomes of Post Spaceflight Stand Tests are Consistent from Flight to Flight

The overall prevalence of orthostatic hypotension after short duration (6-18 d) spaceflight is 20% with existing countermeasures. However, it is not known if the outcomes of stand tests for orthostatic tolerance are consistent within individuals on subsequent flights, or if first time fliers are more (or less) likely to experience orthostatic hypotension and presyncope than are veteran astronauts. Fifty astronauts were studied retrospectively. Stand test data, which had been collected before and after spaceflight, were compared from at least two flights for each astronaut. For twenty-five of these astronauts, their first flight in this database was also their first time to fly into space. For the remaining 25, their first flight in this database was their second, third or fourth flight, as data were available. No subject became presyncopal during preflight testing. Of the 50 subjects, 45 (90%) had the same outcome on their first and second fligh ts of this study. Of 14 subjects on whom we had data from a third mission, 12 had the same stand test outcome on all three flights (86% same outcome across three flights). There was no correlation between flight duration and orthostatic tolerance (r = 0.39). These data support the idea that astronauts are predisposed to orthostatic tolerance/intolerance after spaceflight and that this predisposition is not altered by subsequent flights. Flight durations within this data set did not alter the likelihood of orthostatic intolerance and rookie fliers were no more likely to experience orthostatic intolerance than were veteran astronauts.

Martin, D. S.↗

Application of the Life Safety Code to a Historic Test Stand

NASA has conducted a study to assess alternatives to refurbishing existing launch vehicle modal test facilities as opposed to developing new test facilities to meet the demands of a very fiscally constrained test and evaluation environment. The results of this study showed that Marshall Space Flight Center (MSFC) Test Stand (TS) 4550 could be made compliant, within reasonable cost and schedule impacts, if safety processes and operational limitations were put in place to meet the safety codes and concerns of the Fire Marshall. Trades were performed with key selection criteria to ensure that appropriate levels of occupant safety are incorporated into test facility design modifications. In preparation for the ground vibration tests that were to be performed on the Ares I launch vehicle, the Ares Flight and Integrated Test Office (FITO) organization evaluated the available test facility options, which included the existing mothballed structural dynamic TS4550 used by Apollo and Shuttle, alternative ground vibration test facilities at other locations, and construction of a new dynamic test stand. After an exhaustive assessment of the alternatives, the results favored modifying the TS4550 because it was the lowest cost option and presented the least schedule risk to the NASA Constellation Program for Ares Integrated Vehicle Ground Vibration Test (IVGVT). As the renovation design plans and drawings were being developed for TS4550, a safety concern was discovered the original design for the construction of the test stand, originally built for the Apollo Program and renovated for the Shuttle Program, was completed before NASA s adoption of the currently imposed safety and building codes per National Fire Protection Association Life Safety Code [NFPA 101] and International Building Codes. The initial FITO assessment of the design changes, required to make TS4550 compliant with current safety and building standards, identified a significant cost increase and schedule impact. An effort was launched to thoroughly evaluate the applicable life safety requirements, examine the context in which they were derived, and determine a means by which the TS4550 modifications could be made within budget and on schedule, while still providing the occupants with appropriate levels of safety.

Askins, Bruce↗

Installation of TVC Actuators in a Two Axis Inertial Load Simulator Test Stand

This paper is about the installation of Space Shuttle Main Engines (SSME) actuators in the new Two Axis Inertial Load Simulator (ILS) at MSFC. The new test stand will support the core stage of the Space Launch System (SLS). Because of the unique geometry of the new test stand standard actuator installation procedures will not work. I have been asked to develop a design on how to install the actuators into the new test stand. After speaking with the engineers and technicians I have created a possible design solution. Using Pro Engineer design software and running my own stress calculations I have proven my design is feasible. I have learned how to calculate the stresses my design will see from this task. From the calculations I have learned I have over built the apparatus. I have also expanded my knowledge of Pro Engineer and was able to create a model of my idea.

Dziubanek, Adam↗

Lightning Protection and Structural Bonding for the B2 Test Stand

With the privatization of the space industry, NASA has entered a new era. To explore deeper parts of the solar system, NASA is developing a new spacecraft, the Space Launch System (SLS), capable of reaching these destinations, such as an asteroid or Mars. However, the test stand that is capable of testing the stage has been unused for many years. In addition to the updating/repair of the stand, more steel is being added to fully support the SLS. With all these modifications, the lightning protection system must be brought up to code to assure the protection of all personnel and assets. Structural bonding is a part of the lightning protection system. The focus of this project was to assure proper structural bonding. To begin, all relevant technical standards and the construction specifications were reviewed. This included both the specifications for the lightning protection and for general construction. The drawings were reviewed as well. From the drawings, bolted structural joints were reviewed to determine whether bonding was necessary. Several bolted joints were determined to need bonding according to the notes in the drawings. This exceeds the industry standards. The bolted joints are an electrically continuous joint. During tests, the stand experiences heavy vibration that may weaken the continuity of the bolted joint. Therefore, the secondary bonding is implemented to ensure that the structural joint has low resistance. If the structural joint has a high resistance because of corrosion, a potential gradient can occur that can cause a side flash. Damage, injury, or death can occur from a side flash so they are to be prevented. A list of the identified structural joints was compiled and sent to the contractor to be bonded. That covers the scope of this project.

Kinard, Brandon↗

Astronaut Kinematics and Injury Risk for Piloted Lunar Landings and Launches While Standing

During future lunar missions, astronauts may be required to pilot vehicles while standing, and the associated kinematic and injury response is not well understood. In this study we used human body modeling to predict unsuited astronaut kinematics and injury risk for piloted lunar launches and landings in the standing posture. Three pulses (2-5 g; 10–150 ms rise times) were applied in 10 directions (vertical; ± 10-degree offsets) for a total of 30 simulations. Across all simulations, motion envelopes were computed to quantify displacement of the astronaut’s head (max 9.0 cm forward, 7.0 cm backward, 2.1 cm upward, 7.3 cm downward, 2.4 cm lateral) and arms (max 25 cm forward, 35 cm backward, 15 cm upward, 20 cm downward, 20 cm lateral). All head, neck, lumbar, and lower extremity injury metrics were within NASA’s tolerance limits, except tibia compression forces (0–1543 N upper tibia; 0–1482 N lower tibia; tolerance—1350 N) and revised tibia index (0.04–0.58 upper tibia; 0.03–0.48 lower tibia; tolerance—0.43) for the 2.7 g/150 ms pulse. Pulse magnitude and duration contributed over 80% to the injury metric values, whereas loading direction contributed less than 3%. Overall, these simulations suggest piloting a lunar lander vehicle in the standing posture presents a low risk of injury to the astronaut, although risk of tibia injury is potentially outside NASA’s acceptance limits and warrants further investigation.

Mitesh Lalwala↗

Identification of Noise Sources in a Rocket Engine Test Stand using Microphone Phased Array

A new, phased array of microphones, suitable for the harsh environment of a rocket launch, was built and tested during a static firing of a RS-25 engine. It uses 70 piezo-resistive, dynamic pressure sensors, optimally distributed on a 10.5ft diameter open frame dome structure, and has a 200-ft long cable bundle to carry the signals to a weather-protected cabinet containing the data systems. The test stand was imaged using an infra-red camera and a visible wavelength camera, and the beamformed noise maps were superimposed on the photographs. The first-time data from a full-scale engine test stand showed that the plume deflector at the bottom of the engine to be the primary noise source. The openings of the test stand around the nozzle exit were also found to be noise sources particularly at higher frequencies. The final goal is to use the array during NASA’s Artemis-II launch at Kennedy Space Center.

Identification of Noise Source↗

Design Concepts for an Optimized, Modular, and Scalable Liquid Amine Test Stand

The Air Revitalization Labs at NASA Ames Research Center (ARC) is investigating liquid amines to for their performance removing spacecraft carbon dioxide (CO2) for crewed space missions. Development of the current one-crew scale amine test stand stems from several modifications to a test stand initially built at NASA Johnson Space Center (JSC) This sub-scale system has been modified to incorporate a flow spreader for the inlet air stream, an updated contactor design for CO2 capture, a degasser to regenerate the liquid sorbent and recover the captured CO2, and a condenser to reduce water loss. Results from the existing integrated liquid amine test stand have provided valuable insight, but continued performance optimization requires design and build of a new integrated test system. New design concepts will institute a modular configuration to allow for interfacing with novel contactor and degasser architecture, parallel or series flow pathways for the air stream and liquid sorbent, and scaling up to a 4-crew CO2 removal system.

Tiago Faria Costa↗

Commissioning of the Low Energy Electron Gun Test Stand at the University of Chicago

We built a test stand for evaluating the performance of the thermionic electron sources for the electron lens project at the Integrable Optics Test Accelerator (IOTA) in Fermilab. The lens will be used to study nonlinear dynamics and electron cooling of 2.5 MeV protons with strong space charge. The test stand will validate the characteristics of the thermionic sources and the main parameters of the generated beams. In this paper we present the results of the commissioning of the UChicago test stand and validation of the hollow beam source.

43 PARTICLE ACCELERATORS↗

Renewable Diesel Production through Stand-Alone and Co-Hydrotreating of Catalytic Fast Pyrolysis Oil

Catalytic Fast Pyrolysis (CFP) of biomass followed by hydrotreating can be used for the production of renewable transportation fuels, such as sustainable aviation fuel and renewable diesel, which can reduce the dependence on fossil fuels and help achieve greenhouse gas reduction goals. Stand-alone hydrotreating of CFP oil and co-hydrotreating of the CFP oil with straight-run diesel (SRD) showed potential to produce high-quality diesel products in this study. Stand-alone hydrotreating of CFP oil produced a diesel fraction with oxygen content < 0.1 wt.% and an indicated cetane number (ICN) of 45. Co-hydrotreating of CFP oil and SRD using a 1:4 volumetric ratio produced diesel products with 0.1 wt.% of oxygen and ICNs of 42-45. Compared to CoMo/Al2O3, NiMo/Al2O3 was a more attractive catalyst for co-hydrotreating of two streams, leading to a higher carbon efficiency, a higher selectivity of cycloalkanes, a higher ICN, and enhanced desulfurization. Compared to stand-alone hydrotreating of CFP oil, co-hydrotreating with SRD could be achieved at a less severe operating condition and it produced hydrotreated products with a higher carbon efficiency. Synergy between CFP oil and SRD during co-hydrotreating process was suggested by the better experimental results in comparison with theoretical interpolation results. Co-hydrotreating gave high biogenic carbon incorporations of 91%-97% as determined by C-14 analysis.

biomass↗

Permeability of Single–Layer–Free–Standing Meshes at Varying Capillary Pressure via a Novel Method

The permeability of mesh wicks is important for various applications, including two–phase heat transfer. However, the understanding of the permeability of single–layer, free–standing mesh wicks, with liquid–gas interfaces on both sides, is limited. A novel and simpler method is presented to determine the permeability of a free–standing wick and apply it to a representative mesh. This method involves modifying the capillary pressure via elevation and simultaneously measuring the permeability to determine the permeability–capillary pressure relationship. When applied to a copper mesh with plain weave having undergone surface cleaning, the permeability is found to decrease as capillary pressure for deionized water increases. A dimensional analysis is presented to generalize this data for other mesh sizes with similar weaves and fluids. The behavior of mesh in application is modeled, based on the integration of Darcy's law with an analytic function fit to measured data, and parametric studies are conducted to investigate the superficial velocity of liquids through the mesh under varying driving pressures, transport lengths, and liquid viscosity, based on the obtained capillary pressure–permeability relationship. This study provides valuable insights into the transport properties of mesh wicks, with potential applications in fields such as electronics cooling, electrochemical devices, and fluid purification technologies.

36 MATERIALS SCIENCE↗

On High-Temperature Dynamometer Test Stand Development

RePED is a novel prototype alternator that has been designed and built to operate at 35 kW under 250 degrees C ambient temperature conditions. The operating efficiency will be measured using a 225-kW motor to drive the machine in a back-to-back configuration. The goal is to determine if the RePED alternator can deliver 35 kW at a rotational speed of 1,000 rpm while operating in 250 degrees C ambient temperature and have a minimum efficiency of 60%. Dynamometer testing of a high-temperature alternator for geothermal drilling presents several unique challenges, especially around maintaining and managing the various sources and types of energy passing through the system without impacting data quality. The objectives of this report are to (1) describe the test stand in detail, the relative orientation of each major component, and the data acquisition system and (2) discuss the behavior of the test stand components such that this report can serve as a reference document for future projects.

15 GEOTHERMAL ENERGY↗

Pretest Comprehensive Analysis for the Urban Air Mobility Side-by-Side Test Stand

The Urban Air Mobility (UAM) Side-by-Side Test Stand (SBS) is a two-rotor test stand designed and built at NASA Ames Research Center under the Revolutionary Vertical Lift Technology (RVLT) Project. The SBS entered service in the wind tunnel in the latter part of 2021 and allows for the experimental analysis of rotor-rotor interactions for UAM vehicles of the side-by-side variety. The SBS will allow investigation of the effect of numerous variables such as rotor lateral separation, rotor collective pitch, model pitch angle (𝛼), rotor rotation direction, and flight speed. This paper presents performance predictions for the SBS. These predictions, which were generated using CAMRAD II, provided increased assurance of the safe operational limits of the system. Additionally, these results, when compared with future data, will be used for validation of the computational models.

Comprehensive Analysis↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗

Magnetosonic ULF Waves With Anomalous Plasma–Magnetic Field Correlations: Standing Waves and Inhomogeneous Plasmas

Ultra-low frequency (ULF) wave observations across the heliosphere often rely on the sign of correlations between plasma (density/pressure) and magnetic field perturbations to distinguish between fast and slow magnetosonic modes. However, the assumptions behind this magnetohydrodynamic result are not always valid, particularly within the magnetosphere which is inhomogeneous and supports standing waves along the geomagnetic field. Through theory and a global simulation, we find both effects can result in anomalous plasma–magnetic field correlations. The interference pattern in standing waves can lead both body and surface magnetosonic waves to have different cross-phases than their constituent propagating waves. Furthermore, if the scale of gradients in the background are shorter than the wavelength or the waves are near-incompressible, then advection by the wave of inhomogeneities can overcome the wave's inherent sense of compression. These effects need to be allowed for and taken into account when applying the typical diagnostic to observations.

MHD Waves↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗

STAND Quickstart Guide

STAND is a flexible web application designed to identify and examine potentially feasible sites where advanced nuclear facilities might be welcomed by host communities. STAND allows the user to explore and provide insight on socioeconomic, proximity, and safety data, generate county reports, review regulatory data, and complete a comparative analysis across multiple sites by following several paths, either individually or sequentially based on the user’s needs and where they are in the deployment process.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗