Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STAGNATION PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Maximum two-phase flow rates of subcooled nitrogen through a sharp-edged orifice

An experiment was conducted and data are presented in which subcooled liquid nitrogen was discharged through a sharp-edged orifice at flow rates near the maximum. The data covered a range of inlet stagnation pressure from slightly above saturation to twice the thermodynamic critical pressure. The data were taken along five separate inlet stagnation isotherms ranging from 0.75 to 1.035 times the thermodynamic critical temperature. The results indicate that: (1) subcooled liquids do not choke or approach maximum flow in an asymptotic manner even though the back pressure is well below saturation; (2) orifice flow coefficients are not constant as is frequently assumed. A metastable jet appears to exist which breaks down if the difference between back pressure and saturation pressure is large enough.

Simoneau, R. J.↗

The Scaling of Broadband Shock-Associated Noise with Increasing Temperature

A physical explanation for the saturation of broadband shock-associated noise (BBSAN) intensity with increasing jet stagnation temperature has eluded investigators. An explanation is proposed for this phenomenon with the use of an acoustic analogy. To isolate the relevant physics, the scaling of BBSAN peak intensity level at the sideline observer location is examined. The equivalent source within the framework of an acoustic analogy for BBSAN is based on local field quantities at shock wave shear layer interactions. The equivalent source combined with accurate calculations of the propagation of sound through the jet shear layer, using an adjoint vector Green's function solver of the linearized Euler equations, allows for predictions that retain the scaling with respect to stagnation pressure and allows for saturation of BBSAN with increasing stagnation temperature. The sources and vector Green's function have arguments involving the steady Reynolds- Averaged Navier-Stokes solution of the jet. It is proposed that saturation of BBSAN with increasing jet temperature occurs due to a balance between the amplication of the sound propagation through the shear layer and the source term scaling.

Miller, Steven A. E.↗

Absorption Laser Differential Interferometry for Simultaneous Colinear Flow Property and Fluctuation Measurements

An absorption laser differential interferometer (A-LDI) was constructed and tested in an effort to simultaneously and colinearly measure flow properties (pressure, temperature, concentration) and flow fluctuations (changes in optical path length). Whereas typical LDI and focused LDI (FLDI) systems use fixed wavelength lasers as the light source (often either green at approximately 532 nm or red at approximately 630 nm), a tunable 760 nm diode laser was used to probe the A-band absorption spectrum of molecular oxygen. The A-LDI system was used to measure O2 absorption and flow fluctuations in a sub-atmospheric pressure-controlled test cell, with absorption profiles from direct absorption and wavelength modulation absorption matching simulated results, while simultaneously being sensitive to high frequency fluctuations from jets of either compressed air or 100% O2 from a gas bottle. The A-LDI system was also installed at the NASA Langley Research Center Probe Calibration Tunnel to assess the freestream flow state in a Mach 3.5 flow. LDI measurements of the freestream indicated increasing amplitudes of flow fluctuations with increasing stagnation pressure at a fixed stagnation temperature, while absorption results demonstrated sensitivity to freestream pressure changes.

Joshua M. Weisberger↗

Results of closed cycle MHD power generation tests with a helium-cesium working fluid

The cross-sectional dimensions of the MHD channel in the NASA Lewis closed loop facility have been reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 1.6 x 10 to the 5th N/sq m, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/m. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/m were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/cu m have been obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those reported for the m = 0.2 channel at the last EAM Symposium.

Sovie, R. J.↗

Three dimensional mean flow and turbulence characteristics of the near wake of a compressor rotor blade

The investigation was carried out using the rotating hot wire technique. Measurements were taken inside the end wall boundary layer to discern the effect of annulus and hub wall boundary layer, secondary flow, and tip leakage on the wake structure. Static pressure gradients across the wake were measured using a static stagnation pressure probe insensitive to flow direction changes. The axial and the tangential velocity defects, the radial component of velocity, and turbulence intensities were found to be very large as compared to the near and far wake regions. The radial velocities in the trailing edge region exhibited characteristics prevalent in a trailing vortex system. Flow near the blade tips found to be highly complex due to interaction of the end wall boundary layers, secondary flows, and tip leakage flow with the wake. The streamwise curvature was found to be appreciable near the blade trailing edge. Flow properties in the trailing edge region are quite different compared to that in the near and far wake regions with respect to their decay characteristics, similarity, etc. Fourier decomposition of the rotor wake revealed that for a normalized wake only the first three coefficients are dominant.

Ravindranath, A.↗

Experiments on high speed ejectors

Experimental studies were conducted to investigate the flow and the performance of thrust augmenting ejectors for flight Mach numbers in the range of 0.5 to 0.8, primary air stagnation pressures up to 107 psig (738 kPa), and primary air stagnation temperatures up to 1250 F (677 C). The experiment verified the existence of the second solution ejector flow, where the flow after complete mixing is supersonic. Thrust augmentation in excess of 1.2 was demonstrated for both hot and cold primary jets. The experimental ejector performed better than the corresponding theoretical optimal first solution ejector, where the mixed flow is subsonic. Further studies are required to realize the full potential of the second solution ejector. The research program was started by the Flight Dynamics Research Corporation (FDRC) to investigate the characteristic of a high speed ejector which augments thrust of a jet at high flight speeds.

Wu, J. J.↗

High Reynolds number transonic tests on a NACA 0012 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

Tests were conducted in the two-dimensional test section of the Langley 0.3-m Transonic Cryogenic Tunnel on a NACA 0012 airfoil to obtain aerodynamic data as a part of the Advanced Technology Airfoil Test (ATAT) program. The test program covered a Mach number range of 0.30 to 0.82 and a Reynolds number range of 3.0 to 45.0 x 10 to the 6th. The stagnation pressure was varied between 1.2 and 6.0 atmospheres and the stagnation temperature was varied between 300 K and 90 K to obtain these test conditions. Plots of the spanwise variation of drag coefficient as a function of normal force coefficient and the variation of the basic aerodynamic characteristics with angle of attack are shown. The data are presented uncorrected for wall interference effects and without analysis.

Ladson, Charles L.↗

Tests Of Array Of Flush Pressure Sensors

Report describes tests of array of pressure sensors connected to small orifices flush with surface of 1/7-scale model of F-14 airplane in wind tunnel. Part of effort to determine whether pressure parameters consisting of various sums, differences, and ratios of measured pressures used to compute accurately free-stream values of stagnation pressure, static pressure, angle of attack, angle of sideslip, and mach number. Such arrays of sensors and associated processing circuitry integrated into advanced aircraft as parts of flight-monitoring and -controlling systems.

Larson, Larry J.↗

Estimation of fan pressure ratio requirements and operating performance for the National Transonic Facility

The National Transonic Facility (NTF), a fan-driven, transonic, pressurized, cryogenic wind tunnel, will operate over the Mach number range of 0.10 to 1.20 with stagnation pressures varying from 1.00 to about 8.8 atm and stagnation temperatures varying from 77 to 340 K. The NTF is cooled to cryogenic temperatures by the injection of liquid nitrogen into the tunnel stream with gaseous nitrogen as the test gas. The NTF can also operate at ambient temperatures using a conventional chilled water heat exchanger with air on nitrogen as the test gas. The methods used in estimating the fan pressure ratio requirements are described. The estimated NTF operating envelopes at Mach numbers from 0.10 to 1.20 are presented.

Gloss, B. B.↗

The effect of test-cell pressure on resistojet nozzle flow

Previous experimental work has shown that measured resistojet thrust decreases from that obtained at hard vacuum conditions as the test-cell pressure rises above 0.001 torr. Thrust losses have been observed for both cold and heated flow conditions, and the most significant losses have been experienced using thrusters with low Reynolds number flow and high area ratio nozzles. In order to further investigate nozzle flow characteristics, a pressure probe having four degrees of freedom has been used to obtain stagnation pressure surveys across the nozzle exit planes of four resistojets. The surveys show a change in the ratio of the supersonic core to the viscous boundary layer flow areas as the test-cell pressure increases. The surveys are also used for detecting whether an oblique shock is present in an overexpanded nozzle flow. Thruster temperature measurements and nozzle exit plane pressure surveys indicate that thrust losses are the combined result of convection heat losses and nozzle flow momentum effects.

Penko, Paul F.↗

A visual study of radial inward choked flow of liquid nitrogen.

Data and high speed movies were acquired on pressurized subcooled liquid nitrogen flowing radially inward through a 0.0076 cm gap. The stagnation pressure ranged from 0.7 to 4 MN/sq m. Steady radial inward choked flow appears equivalent to steady choked flow through axisymmetric nozzles. Transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets. The critical mass flow rate data for the transient case appear different from those for the steady case. On the mass flow rate vs pressure map, the slope and separation of the isotherms appear to be less for transient than for steady radial choked flow.

Hendricks, R. C.↗

Mean velocity and decay characteristics of the near- and far-wake of a compressor rotor blade of moderate loading

This paper reports the experimental study of the three-dimensional characteristics of the mean velocity in the wake of a moderately loaded compressor rotor blade. The measurements were taken with a three-sensor hot-wire probe rotating with the rotor. The wake was surveyed at several radial and axial stations. The loading was found to have substantial effect and this was reflected not only in the axial and tangential components, but also in the radial component. The radial velocities were found to be high very near the trailing-edge and this exhibits the characteristics prevalent in a trailing vortex system. The static pressures across the wake were measured using a direction insensitive spherical head static-stagnation pressure probe. The static pressure was found to be higher inside the wake. These and other measurements are reported and correlated in this paper.

Ravindranath, A.↗

Viking Mars mission support investigations in the Langley transonic dynamics tunnel

Six experimental investigations conducted in the transonic dynamics tunnel, which supported elements of the entry and the landed phases of the Viking mission, are described. The objective of each investigation and selected experimental results are presented. How these particular wind tunnel results contributed to spacecraft development and ultimately to the success of the Viking mission is indicated. Experimental studies applicable to the entry phase of the mission included parachute environment and performance definition, aerodynamic characteristics exhibited by two separating bodies, and pressure measurements in the transonic range to optimize the location and orientation of a stagnation-pressure sensor on the Lander. The experimental investigations which supported the landed phase of the mission included a convective heat transfer test to establish the requirements for wind covers for the radioisotope thermoelectric generators and two tests which supported the development and calibration of the meteorological science experiment.

Foughner, J. T., Jr.↗

Trajectory characteristics and heating of hypervelocity projectiles having large ballistic coefficients

A simple, approximate equation describing the velocity-density relationship (or velocity-altitude) has been derived from the flight of large ballistic coefficient projectiles launched at high speeds. The calculations obtained by using the approximate equation compared well with results for numerical integrations of the exact equations of motion. The flightpath equation was used to parametrically calculate maximum body decelerations and stagnation pressures for initial velocities from 2 to 6 km/s. Expressions were derived for the stagnation-point convective heating rates and total heat loads. The stagnation-point heating was parametrically calculated for a nonablating wall and an ablating carbon surface. Although the heating rates were very high, the pulse decayed quickly. The total nose-region heat shield weight was conservatively estimated to be only about 1 percent of the body mass.

Tauber, Michael E.↗

Pressure distributions from high Reynolds number transonic tests of an NACA 0012 airfoil in the Langley 0.3-meter transonic cryogenic tunnel

Tests were conducted in the 2-D test section of the Langley 0.3-meter Transonic Cryogenic Tunnel on a NACA 0012 airfoil to obtain aerodynamic data as a part of the Advanced Technology Airfoil Test (ATAT) program. The test program covered a Mach number range of 0.30 to 0.82 and a Reynolds number range of 3.0 to 45.0 x 10 to the 6th power. The stagnation pressure was varied between 1.2 and 6.0 atmospheres and the stagnation temperature was varied between 300 K and 90 K to obtain these test conditions. Tabulated pressure distributions and integrated force and moment coefficients are presented as well as plots of the surface pressure distributions. The data are presented uncorrected for wall interference effects and without analysis.

Ladson, Charles L.↗

Time-dependent measurement of base pressure in a blowdown tunnel with varying unit Reynolds number

An operational characteristic of blowdown-type of wind tunnels is the drop in the stagnation temperature with time and the accompanying change in the test-section unit Reynolds number at constant stagnation pressure and Mach number. This apparent disadvantage can be turned to advantage in some cases where a Reynolds number scan is desired in order to study the effect of unit Reynolds number variation on a particular viscous flow phenomenon. This note presents such an instance arising from recent investigations on base pressure at transonic speeds conducted in the NAL 1-ft tunnel.

Kangovi, S.↗

Description and calibration of the Langley 6- by 28-inch transonic tunnel

The Langley 6 by 28 inch transonic tunnel is described. The tunnel is a two dimensional facility with slotted top and bottom walls, used for testing two dimensional airfoil sections. Basic tunnel-empty Mach number distributions, noise surveys, and test section total pressure surveys are presented. The Mach number capability of the facility is from about 0.3 to 1.2. The stagnation pressure can be varied from 207 kN/sq m (30 lb/sq in) absolute to 620 kN/sq m (90 lb/sq in) absolute. This range of pressure can provide a Reynolds number of about 10 million, based on a 15.2 cm (6.0 in.) model chord at Mach numbers from 0.5 to 1.0. The maximum Reynolds number capability at a Mach number of 1.0 is about 15 million, based on the same model chord.

Ladson, C. L.↗

Characteristics of the NASA-Ames Laminar Flow Supersonic Wind Tunnel for Unique Mach 1.6 Transition Studies

Flow quality measurements have been performed in the unique Laminar Flow Supersonic Wind Tunnel (LFSWT) to examine both mean and dynamic characteristics. The intent was to provide the necessary flow information about this ground test facility, to support meaningful transition research at Mach 1.6 and flight unit Reynolds numbers. This paper is intended to assist other experimentalists with similar goals of characterizing low-supersonic test environments. An array of instrumentation has been used to highlight the importance of proper selection of pressure instruments and data acquisition procedures. We conclude that the test section is low-disturbance (based on classical standards of pressure disturbances less than 0.1% with no specified data bandwidth), and has uniform flow. This is confirmation that the quiet design features of the LFSWT are effective. However, characterization of the test section flow over a 0.25k-5Ok bandwidth shows that the disturbance levels can be greater than classical standards particularly for stagnation pressures less than 9.5 psia (0.65 bar) with low stagnation temperatures. Variability of the flow disturbances in the settling chamber and test section is contained in a narrow frequency bandwidth below 5k Hz, which is associated with resonant frequencies from the pressure reduction system. So far, these disturbances have not impacted transition along the tunnel walls or a 10 degrees cone. However, continual vigilance is required to maintain a known low-disturbance environment for transition research in the LFSWT. Furthermore, the formation of standards for flow quality measurements is strongly recommended, so that transition research can be better isolated from tunnel disturbances.

Wolf, Stephen W. D.↗