Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Examining the Effects of Oxygen Doping on SRF Cavity Performance

Superconducting radiofrequency (SRF) cavities are resonators with extremely low surface resistance that enable accelerating cavities to have extremely high quality factors (Q₀). High (Q₀) decreases the capital required to keep accelerators cold by reducing power loss. The performance of SRF cavities is largely governed by the surface composition of the first 100 nm of the cavity surface. Impurities such as oxygen and nitrogen have been observed to yield high Q₀, but their precise roles are still being studied. Here, we compare the performance of cavities doped with nitrogen and oxygen in terms of fundamental material properties to understand how these impurities affect performance. This enables us to have further insight into the underlying mechanisms that enable these surface treatments to yield high Q₀ performance.

43 PARTICLE ACCELERATORS↗

Analysis of Low RRR SRF Cavities

Recent findings in the superconducting radio-frequency (SRF) community have shown that introducing certain impurities into high-purity niobium can improve quality factors and accelerating gradients. Success has been found in nitrogen-doping, diffusion of the native oxide into the niobium surface, and thin films of alternate superconductors atop a niobium bulk cavity. We question why some impurities improve RF performance while others hinder it. The purpose of this study is to characterize the impurity profile of niobium with a low residual resistance ratio (RRR) and correlate these impurities with the RF performance of low RRR cavities so that the mechanism of recent impurity-based improvements can be better understood and improved upon. Additionally, we performed surface treatments, low temperature baking and nitrogen-doping, on low RRR cavities to evaluate how the intentional addition of more impurities to the RF layer affects performance. We have found that low RRR cavities experience low temperature-dependent BCS resistance behavior more prominently than their high RRR counterparts. The results of this study have the potential to unlock a new understanding on SRF materials.

43 PARTICLE ACCELERATORS↗

Field Emission Mitigation in CEBAF SRF Cavities Using Deep Learning

The Continuous Electron Beam Accelerator Facility (CEBAF) operates hundreds of superconducting radio frequency (SRF) cavities in its two main linear accelerators. Field emission can occur when the cavities are set to high operating RF gradients and is an ongoing operational challenge. This is especially true in newer, higher gradient SRF cavities. Field emission results in damage to accelerator hardware, generates high levels of neutron and gamma radiation, and has deleterious effects on CEBAF operations. So, field emission reduction is imperative for the reliable, high gradient operation of CEBAF that is required by experimenters. Here we explore the use of deep learning architectures via multilayer perceptron to simultaneously model radiation measurements at multiple detectors in response to arbitrary gradient distributions. These models are trained on collected data and could be used to minimize the radiation production through gradient redistribution. This work builds on previous efforts in developing machine learning (ML) models, and is able to produce similar model performance as our previous ML model without requiring knowledge of the field emission onset for each cavity.

Ahammed, K.↗

DEMONSTRATION OF TWICE REDUCED LORENTZ FORCE DETUNING IN SRF CAVITY BY COPPER COLD SPRAYING

Superconducting RF (SRF) cavities usually are made of thin-wall high RRR Niobium that is susceptible to Lorentz Force Detuning (LFD) ? cavity deformation phenomena caused by high magnitude RF fields. This type of deformation can be mitigated by using an additional copper layer deposited on the outer surface of the cavity. In this paper, we present both modeling results and experimental data of high gradient test of an SRF cavity at cryogenic temperatures. It was demonstrated that LFD can be significantly reduced (factor of two) by the copper cold spray reinforcement without sacrificing cavity flexibility for tuning. We also present a finite-element model that allows us to confirm our experimental results and optimize the cavity geometry for LFD reduction with incorporated coupled RF, structural and thermal modules.

Kostin, R.↗

Advancing Conduction-Cooled 650 MHz SRF Technology for Industrial Accelerators at Fermilab's IARC

The National Nuclear Security Administration (NNSA) funds the Illinois Accelerator Research Center (IARC) at Fermilab in developing a high-power, conduction-cooled Superconducting Radio Frequency (SRF) accelerator tailored for industrial applications requiring robust and efficient operation. A 650 MHz, 1.6 MeV, 20 kW SRF accelerator is currently under development, employing a conduction cooling approach to simplify cryogenic requirements and enhance accessibility for industrial use. The accelerator’s control system is implemented on the Blinky Lite platform, selected for its open-source architecture, secure remote access capabilities, and operational flexibility—attributes advantageous for industrial deployment and sustained operation. A dedicated beamline is designed to measure essential beam parameters and test the integrated performance of the accelerator and control systems, thereby validating their operational readiness for intended applications

Ji, Y. [Fermilab] (ORCID:0000000233981752)↗

Validation of the 650 MHz SRF Cavity Tuner for PIP-II at 2 K

The PIP-II linac will include thirty-six β=0.61 and twenty-four β=0.92 650 MHz 5 cell elliptical SRF cavities. Each cavity will be equipped with a tuning system consisting of a double lever slow tuner for coarse frequency tuning and a piezoelectric actuator for fine frequency tuning. One dressed cavity equipped with an SRF tuner has been tested in the horizontal test stand at Fermilab. Results of testing the cavity-tuner system will be presented.

43 PARTICLE ACCELERATORS↗

A Fast Mechanical Tuner for SRF Cavities

There is a particular need for fast tuners and phase shifters for advanced superconducting accelerator RF systems. The tuners based on ferrite, ferroelectric and piezo materials are commonly used. However, those methods suffer from one or another issue of high power loss, slow response, and narrow tuning range. We propose a robust, fast (up to ~5 MHz/sec), high efficient mechanical tuner for SRF cavities operating at the frequency 50 MHz. We develop an external mechanical tuner that is strongly coupled to the cavity. The tuner design represents a trade-off of high efficiency (low RF losses and low heat flux) and frequency tunability range. Our approach solves this trade-off issue. We propose RF design which exploits two coupled resonators so that a main high-field cavity is controlled with a small tunable resonator with a flexible metallic wall operating in a relatively low RF field. Simulations, carried out for a 7.5 MV/m 50 MHz SRF Quarter Wave Resonator (QWR), show that frequency tunability at level 10⁻³ is obtainable.

43 PARTICLE ACCELERATORS↗

Review of the Application Piezoelectric Actuators for SRF Cavity Tuners

Large SRF Linacs and HEP experiments require accurate frequency control, which is achieved using cavity tuners typically actuated by the piezoelectric ceramic stacks. The piezoelectric ceramic stacks became ’standard’ components of the SRF cavity tuner and, depending on the application, could be operated in the different environment: in air, at cryogenic temperature, in vacuum, and submerged in liquid helium. Different applications place different requirements on the piezo actuators, but the important parameters, common to all applications, are the lifetime and reliability of the actuators. Several R&D programs targeting the development of reliable piezo actuators are reviewed in this contribution.

43 PARTICLE ACCELERATORS↗

Microstructure development in a cold worked SRF Nb sheet undergoing 700°C-900°C/3h heat treatments.

Bulk Nb for TESLA shaped SRF cavities is a mature technology, with high gradient (>35 MV/m) and high Q cavities (>1010, ~2K) routinely fabricated. Significant advances are in order to push Q?s to 1011 (~2K), and involve modifications to the sub-surface Nb layers by impurity doping (N, O). In order to achieve the lowest surface resistance any trapped flux needs to be expelled for cavities to reach high Q?s. There is clear evidence that cavities fabricated from polycrystalline sheets meeting current specifications require higher temperatures beyond 800oC leads to better flux expulsion, and hence improves Q. Recently, cavities fabricated with a non-traditional Nb sheet with initial cold work due to cold rolling expelled flux better after 800°C/3h heat treatment than cavities fabricated using fine-grain polycrystalline Nb sheets. Here, we analyze the microstructure development in Nb from the vendor supplied cold work non-annealed sheet that was fabricated into an SRF cavity as a function of heat treatment building upon the methodology development to analyze microstructure being developed by the FSU-MSU-UT-Austin- JLAB collaboration. The results indicate correlation between full recrystallization and better flux expulsion.

Balachandran, S.↗

SURFACE ROUGHNESS REDUCTION AND PERFORMANCE OF Nb3Sn FILM FOR SRF APPLICATIONS

Nb3Sn offers better RF performance (Q and Eacc) than Nb at any given temperature because of its superior superconducting properties. The potential deployment of Nb3Sn-coated SRF cavities at 4 K, delivering similar performance to that of Nb cavities at 2 K, will be a transformational technology to enable new classes of SRF accelerator applications. A clean and smooth surface can enhance the performance of the Nb3Sn-coated cavity, typically, the attainable acceleration gradient. The reduction of surface roughness is often linked with a correlative reduction in average coating thickness and grain size. A new approach to enhance the nucleation centers using the pre-deposition of Sn on Nb is introduced for surface roughness reduction. Besides Sn supply's careful tuning, the temperature profiles were varied to engineer the coating surface with reduced roughness as low as ~40 nm in 20 µm × 20 µm AFM scans, one-third that of the typical coating. Electropolishing of coated sample shows surface a clear surface smoothening. A few sets of coating parameters were used to coat 1.3 GHz sin-gle-cell cavities to understand the effects of roughness variation on the RF performance. This presentation discusses ways to reduce surface roughness with results from a systematic analysis of the samples and Nb3Sn-coated single-cell cavities.

Pudasaini, Uttar↗

ON THE WAY TO A 10MEV, CONDUCTION-COOLED COMPACT SRF ACCELERATOR

After the success of designing a compact 1MeV, 1MW accelerator based on conduction-cooled SRF, Jefferson Lab is now pursuing a concept to provide a tenfold increase of the beam energy. The obvious challenge for SRF is to move from a single-cell to a multicell cavity while maintaining high efficiency and the ability to operate the machine without a complex cryogenic plant. This paper summarizes the current state of this effort with respect to the design of a Nb3Sn coated five-cell cavity and the corresponding RF components, especially the fundamental power coupler (FPC), as well as first thermal analysis of the cryocooler-based cooling setup.

Ciovati, G.↗

THERMODYNAMIC PROPERTIES OF SRF NIOBIUM

Bulk and thin films of niobium are the materials of choice in fabricating superconducting radio frequency (SRF) cavities for modern particle accelerators and quantum computing applications. The thermodynamic properties of Nb are of particular interest in heat management in cryogenic environments. Here, we report the results of measurements of the thermodynamic properties of niobium used in the fabrication of SRF cavities. The temperature and magnetic field dependence of thermal conductivity, Seebeck coefficient, and specific heat capacity was measured on bulk niobium samples.

Dhakal, Pashupati↗

Conduction-Cooled Operation of an SRF Multi-Cell Cavity

The development of compact, SRF-based accelerators for applications beyond research is experiencing notable advancements due to the use of cryocoolers for conduction-cooling instead of traditional liquid cryogens. Following the successful demonstration of a single-cell cavity operated through conduction cooling with three two-stage cryocoolers, Jefferson Lab (JLab) has made strides in the operation of a multi-cell resonator. This milestone paves the way for high-energy applications of compact, conduction-cooled SRF machines. The demonstration, carried out in collaboration with General Atomics, will take place in a dedicated horizontal test cryostat (HTC) at their San Diego facility. This presentation will highlight the technological developments, the latest results, and valuable lessons learned.

Vennekate, J. [Thomas Jefferson National Accelerat↗

Unveiling the Interplay: Cold Work, Recrystallization, and Flux Expulsion in SRF Cavities

The fabrication of SRF cavities from sheet materials includes deep-drawing, electron beam welding, chemical and mechanical polishing, high-temperature heat treatment, and material diffusion. The performance of these cavities is frequently limited by magnetic flux trapping giving rise to additional rf loss. In this presentation, we thoroughly examine how recrystallization influences flux expulsion in SRF cavities, using cold-worked niobium sheets from various suppliers. Our findings reveal that cold-worked sheets enhance flux expulsion, especially at lower heat treatment temperatures, by promoting improved recrystallization. In particular, a traditionally fabricated Nb cavity half-cell from an annealed poly-crystalline Nb sheet after an 800 C heat treatment leads to a bi-modal microstructure that ties in with flux trapping and inefficient flux expulsion. This non-uniform microstructure is related to varying strain profiles along the cavity shape. A novel approach to prevent this non-uniform microstructure is presented by fabricating a 1.3 GHz single cell Nb cavities with a cold-worked sheet and subsequent heat treatment leading to better flux expulsion after 800 C/3h

Dhakal, P. [Old Dominion Univ., Norfolk, VA (Unite↗

SRF Levitation and Trapping of Nanoparticles Experiment

The levitation and trapping of micro particles using lasers is not a new accomplishment and has been applied in containerless processing and spectroscopy of microparticles. Recent developments in the field of optomechanics have achieved levitating nanoparticles such that quantum phenomena was observed which would have relevance in quantum science and technology. This two-year project sought to levitate and trap mesoscopic particles using radio frequency (RF) fields in a resonating superconducting RF (SRF) cavity. By exploiting the intrinsic characteristics of an SRF resonating cavity, the project was to explore overcoming a major limit faced by current laser trapping techniques. The goal was to establish a foundation to enable the observation of quantum phenomena of an isolated mechanical oscillator interacting with microwave fields. If successful the experiment could establish its ground-breaking relevance to quantum information science and technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using AI for Management of Field Emission in SRF Linacs

Field emission control, mitigation, and reduction is critical for reliable operation of high gradient superconducting radio-frequency (SRF) accelerators. With the SRF cavities at high gradients, the field emission of electrons from cavity walls can occur and will impact the operational gradient, radiological environment via activated components, and reliability of CEBAF’s two linacs. A new effort has started to minimize field emission in the CEBAF linacs by re-distributing cavity gradients. To measure radiation levels, newly designed neutron and gamma radiation dose rate monitors have been installed in both linacs. Artificial intelligence (AI) techniques will be used to identify cavities with high levels of field emission based on control system data such as radiation levels, cryogenic readbacks, and vacuum loads. The gradients on the most offending cavities will be reduced and compensated for by increasing the gradients on least offensive cavities. Training data will be collected during this year’s operational program and initial implementation of AI models will be deployed. Preliminary results and future plans are presented.

Carpenter, Adam↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technology development for modern SRF accelerators

Superconducting RF (SRF) linear accelerators are widely used for scientific application. Challenges, status, breakthroughs and progress in SRF technology for accelerator application are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗