A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

A New Inelastic Neutron Spectrometer HODACA

In this study, a new multiplex-type inelastic neutron scattering spectrometer, HOrizontally Defocusing Analyzer Concurrent data Acquisition spectrometer (HODACA), was recently developed and built at the C1-1 cold neutron beam port in the neutron source reactor JRR-3 at Japan Atomic Energy Agency. The spectrometer is suitable for dynamics measurements in the energy range of -1 meV ≲ ℏω ≲ 7 meV, catering to a broad array of research fields in physics and material science. HODACA combines 24 detectors and 132 pieces of analyzer crystals and has an estimated measurement efficiency that is 70 times greater than the existing conventional triple-axis spectrometer at the C1-1 beam port. The concept, design, specification, and results of commissioning experiments are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-0IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 pm (1000 -4000 cm-') to allow high-resolution, high-speed hyperspectral imaging applications [l-51. One application will be theremote sensing of the measurement of a large number of different atmospheric gases simultaneously in the sameairmass. Due to the use of a combination of birefiingent phase retarders and multiple achromatic phase switches toachieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventionalFourier transform spectrometer but without any moving parts. In this paper, the principle of operations, systemarchitecture and recent experimental progress will be presen.

solild state imaging Fourier tranform spectrometer↗

Electro-optic Imaging Fourier Transform Spectrometer

JPL is developing an innovative compact, low mass, Electro-Optic Imaging Fourier Transform Spectrometer (E-O IFTS) for hyperspectral imaging applications. The spectral region of this spectrometer will be 1 - 2.5 micron (1000-4000/cm) to allow high-resolution, high-speed hyperspectral imaging applications. One application will be the remote sensing of the measurement of a large number of different atmospheric gases simultaneously in the same airmass. Due to the use of a combination of birefringent phase retarders and multiple achromatic phase switches to achieve phase delay, this spectrometer is capable of hyperspectral measurements similar to that of the conventional Fourier transform spectrometer but without any moving parts. In this paper, the principle of operations, system architecture and recent experimental progress will be presented.

liquid crystal achromatic phase switch↗

HyTES: Thermal Imaging Spectrometer Development

The Jet Propulsion Laboratory has developed the Hyperspectral Thermal Emission Spectrometer (HyTES). It is an airborne pushbroom imaging spectrometer based on the Dyson optical configuration. First low altitude test flights are scheduled for later this year. HyTES uses a compact 7.5-12 micrometer m hyperspectral grating spectrometer in combination with a Quantum Well Infrared Photodetector (QWIP) and grating based spectrometer. The Dyson design allows for a very compact and optically fast system (F/1.6). Cooling requirements are minimized due to the single monolithic prism-like grating design. The configuration has the potential to be the optimal science-grade imaging spectroscopy solution for high altitude, lighter-than-air (HAA, LTA) vehicles and unmanned aerial vehicles (UAV) due to its small form factor and relatively low power requirements. The QWIP sensor allows for optimum spatial and spectral uniformity and provides adequate responsivity which allows for near 100mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. The QWIP's repeatability and uniformity will be helpful for data integrity since currently an onboard calibrator is not planned. A calibration will be done before and after eight hour flights to gage any inconsistencies. This has been demonstrated with lab testing. Further test results show adequate NEDT, linearity as well as applicable earth science emissivity target results (Silicates, water) measured in direct sunlight.

remote sensing↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

Wideband Spectroscopy: The Design and Implementation of a 3 GHz, 2048 Channel Digital Spectrometer

A state-of-the-art digital Fourier Transform spectrometer has been developed, with a combination of high bandwidth and fine resolution unavailable elsewhere. Analog signals consisting of radiation emitted by constituents in planetary atmospheres or galactic sources are downconverted and subsequently digitized by a pair of interleaved Analog-to-Digital Converters (ADC). This 6 Gsps (giga sample per second) digital representation of the analog signal is then processed through an FPGA-based streaming Fast Fourier Transform (FFT), the key development described below. Digital spectrometers have many advantages over previously used analog spectrometers, especially in terms of accuracy and resolution, both of which are particularly important for the type of scientific questions to be addressed with next-generation radiometers. The implementation, results and underlying math for this spectrometer, as well as potential for future extension to even higher bandwidth, resolution and channel orthogonality, needed to support proposed future advanced atmospheric science and radioastronomy, are discussed.

field programmable gate array↗

MaGIXS 2: Preparations for the Second Flight of the Marshall Grazing Incidence X-ray Spectrometer

Overview MaGIXS is a slitless soft X-ray (SXR) imaging spectrometer designed to observe solar active regions. - The instrument produces spatially resolved SXR spectra, known as “overlappograms.” (Athiray et al. 2019 & Champey et al., 2022) The first sounding rocket flight of the Marshall Grazing Incidence X-ray Spectrometer occurred on July 30, 2021 from the White Sands Missile Range, New Mexico. - Spectrally pure images of X-ray bright points were obtained through the inversion of overlappograms, e.g. Fig. 3 (Savage et al., 2022). MaGIXS 2 is a simplified version of the original design, less the spectrometer mirror pair. - Eliminating the spectrometer mirror pair improves spatial resolution, increases effective area and the field of view (Table 1). No field stop in this design, data will be an overlappogram with the same spatial and spectral plate scale.

x-ray spectrometer, x-ray optics, solar corona, so↗

An Overview of MaGIXS-2, The Second Flight of the Marshall Grazing Incidence X-ray Spectrometer

MaGIXS is a slitless soft X-ray (SXR) imaging spectrometer designed to observe solar active regions. - The instrument produces spatially resolved SXR spectra, known as “overlappograms.” (Athiray et al. 2019 & Champey et al., 2022) The first sounding rocket flight of the Marshall Grazing Incidence X-ray Spectrometer occurred on July 30, 2021 from the White Sands Missile Range, New Mexico. - Spectrally pure images of X-ray bright points were obtained through the inversion of overlappograms, e.g. Fig. 3 (Savage et al., 2022). MaGIXS 2 is a simplified version of the original design, less the spectrometer mirror pair. - Eliminating the spectrometer mirror pair improves spatial resolution, increases effective area and the field of view (Table 1). No field stop in this design, data will be an overlappogram with the same spatial and spectral plate scale.

x-ray spectrometer, x-ray optics, solar corona, so↗

Tunable Laser Spectrometers for Planetary Science

Distinguishing planetary formation and evolution pathways and understanding the origins of volatiles on planetary bodies requires determination of relative abundances and isotope ratios in the noble gases, and also of the isotope ratios in C, H, N, O and S at high precisions. Traditional planetary mass spectrometers uniquely provide excellent survey capability including the noble gas relative abundances and their isotope ratios. However, to distinguish planetary evolution models for the outer planets, stable isotope ratios in C and O require precisions of ∼10 or better, readily achievable with a tunable laser spectrometer (TLS). As demonstrated on the Mars Curiosity rover, and as planned for a now-selected NASA Venus mission, tunable laser spectrometers play a unique role synergistic with the capabilities of planetary mass spectrometers. The TLS technique of recording infrared absorption spectra at ultrahigh resolution (resolving power λ/δλ ∼ 5 million) provides unambiguous detection of a wide variety of gases such as H2O, H2O2, H2CO, HOCl, NO, NO2, HNO3, N2O, O3, CO, CO2, NH3, N2H4, PH3, H2S, SO2, OCS, HCl, HF, O2, HCN, and CH4, C2H2, C2H4, C2H6 at parts-per-billion levels. Through line-depth or line-area ratio comparisons of adjacent spectral lines, planetary TLS instruments can achieve isotope ratio measurements in C, H, N, O, and S molecules at precisions of ∼1–2, including for the triple isotope components of O and S. Expected performance of TLS instruments for Venus, Saturn, Enceladus and Uranus will be described as constrained by actual measurements reported at Mars on the Curiosity rover.

Planetary↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

Design and Characterization of the Engineering Model of the Spectrometer Onboard LuSEE‐Night

Abstract The Lunar Surface Electromagnetics Explorer—Night, LuSEE‐Night, is a low‐frequency radio astronomy experiment that will explore the cosmic Dark Ages signal on the radio‐quiet farside of the Moon. The LuSEE‐Night carries a radio frequency spectrometer consisting of a set of antennas, analog and digital processing electronics, and will be launched by NASA's Commercial Lunar Payload Services in 2025. The spectrometer is designed to observe the spectrum of the radio sky in the 0.5−50 MHz band. The engineering model (EM) of the four‐channel spectrometer has been developed. The EM has been characterized for linearity, gain, noise, and their temperature dependence, confirming that the EM meets all the requirements for LuSEE‐Night. Three mitigation techniques have been implemented and verified to suppress self‐induced electromagnetic interference. The flight model of the spectrometer is currently being developed and is scheduled to be shipped to the integration site in early 2024.

Tamura, Emi↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

Absolute throughput calibration of multiple spherical crystals for the Orion High-REsolution X-ray spectrometer (OHREX)

We present absolute throughput analysis of several crystals for the Orion High-REsolution X-ray (OHREX) imaging crystal spectrometer using ray tracing and experimental measurements. The OHREX spectrometer is a high-resolution x-ray spectrometer designed to measure spectral line shapes at the Orion laser facility. The spectrometer is fielded with up to two spherical crystals simultaneously covering two independent spectral ranges. Each crystal has a nominal radius of curvature of R = 67.2 cm and is fielded at a nominal Bragg angle of 51.3°. To cover different bands of interest, several different crystals are available, including Ge (111), KAP, and several cuts of quartz, whose resolving power λ/Δλ exceeds 10 000. The calibrated response of the available crystals has previously been reported from measurements at the EBIT-I electron beam ion trap at Lawrence Livermore National Laboratory. Here, we model the absolute throughput of each crystal using ray tracing and verify the results using experimental data for the quartz $(10\bar{1}1)$ crystal.

47 OTHER INSTRUMENTATION↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.