At least 109 records · Page 6

Machine Learning Algorithms for Aerosol and Cloud Detection Using CATS on the ISS

Clouds and aerosols are one of the largest uncertainties in understanding and forecasting the Earth’s changing climate system. The type and height of aerosols are important factors in determining the top-of-atmosphere (TOA) radiation budget, either direct reflection of solar radiation back to space and/or absorption of solar radiation. In addition to their impact on the Earth’s climate system, aerosols near the surface from wildfires, man-made pollution events, and dust storms are hazardous to human health. The phase and height of clouds also play a critical role in determining the role of clouds in the Earth’s climate system. Cirrus clouds in the upper troposphere can induce a significant daytime TOA warming effect, while liquid water clouds near the surface cause a large corresponding cooling effect. Lidar measurements provide accurate vertically resolved information about clouds and aerosols, including complex multi-layer scenes where passive sensors are challenged and at night, when passive sensors are unable to measure cloud and aerosol properties. The Cloud-Aerosol Transport System (CATS) is a lidar instrument that operated for 33 months on the International Space Station (ISS) at the 1064 nm wavelength to measure attenuated total backscatter and depolarization ratio. These fundamental measurements are used to derive “vertical feature mask” cloud and aerosol products, including layer top/base heights, layer geometrical thickness, aerosol type, and cloud phase. While space-based lidar systems like CATS provide cloud and aerosol vertical distributions that improve our understanding of the climate system, averaging of the daytime data from these sensors is required, at the expense of spatial resolution, to improve the daytime signal-to noise (SNR) and thus atmospheric layer detection. This presentation shows results from machine learning (ML) techniques that, when applied to CATS data: 1. improve the 1064 nm SNR 2. enable detection of atmospheric features during daytime with a horizontal resolution of 350 m or 5 km (compared to the 60 km required for standard CATS data products) 3. increase the number of atmospheric layers detected in the CATS data. A Convolutional Neural Network (CNN) trained using CATS standard data products also demonstrated the potential for improved cloud-aerosol discrimination, cloud phase, and aerosol typing compared to the operational CATS algorithms for cloud edges and complex near-surface scenes during daytime. The ML tools described in this paper can facilitate the development of smaller, low-cost lidar systems in the future and enable real-time accessibility of lidar data products from future lidar systems for monitoring and forecasting of hazardous events.

John Yorks↗

Demonstration of improvement in the signal-to-noise ratio of Thomson scattering signal obtained by using a multi-pass optical cavity on the Tokyo Spherical Tokamak-2

The multi-pass Thomson scattering (TS) scheme enables obtaining many photons by accumulating multiple TS signals. The signal-to-noise ratio (SNR) depends on the accumulation number. In this study, we performed multi-pass TS measurements for ohmically heated plasmas, and the relationship between SNR and the accumulation number was investigated. As a result, improvement of SNR in this experiment indicated similar tendency to that calculated for the background noise dominant situation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing Signal Design for Power System Identification

This paper investigates the design of effective input signals for low-level probing of power systems. In 2005, 2006, and 2008 the Western Electricity Coordinating Council (WECC) conducted four large-scale system wide tests of the western interconnected power system where probing signals were injected by modulating the control signal at the Celilo end of the Pacific DC intertie. A major objective of these tests is the accurate estimation of the inter-area electromechanical modes. A key aspect of any such test is the design of an effective probing signal that leads to measured outputs rich in information about the modes. This paper specifically studies low-level probing signal design for power-system identification. The paper describes the design methodology and the advantages of this new probing signal which was successfully applied during these tests. This probing input is a multi-sine signal with its frequency content focused in the range of the inter-area modes. The period of the signal is over two minutes providing high-frequency resolution. Up to 15 cycles of the signal are injected resulting in a processing gain of 15. The resulting system response is studied in the time and frequency domains. Because of the new probing signal characteristics, these results show significant improvement in the output SNR compared to previous tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report on LDRD project 130784 : functional brain imaging by tunable multi-spectral Event-Related Optical Signal (EROS).

Functional brain imaging is of great interest for understanding correlations between specific cognitive processes and underlying neural activity. This understanding can provide the foundation for developing enhanced human-machine interfaces, decision aides, and enhanced cognition at the physiological level. The functional near infrared spectroscopy (fNIRS) based event-related optical signal (EROS) technique can provide direct, high-fidelity measures of temporal and spatial characteristics of neural networks underlying cognitive behavior. However, current EROS systems are hampered by poor signal-to-noise-ratio (SNR) and depth of measure, limiting areas of the brain and associated cognitive processes that can be investigated. We propose to investigate a flexible, tunable, multi-spectral fNIRS EROS system which will provide up to 10x greater SNR as well as improved spatial and temporal resolution through significant improvements in electronics, optoelectronics and optics, as well as contribute to the physiological foundation of higher-order cognitive processes and provide the technical foundation for miniaturized portable neuroimaging systems.

60 APPLIED LIFE SCIENCES↗

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

Laboratory comparison of continuous vs. binary phase-mostly filters

Recent developments in spatial light modulators have led to devices which are capable of continuous phase modulation, even if only over a limited range. One of these devices, the deformable mirror device is used, to compare the relative merits of binary and partially-continuous phase filters in a specific problem of pattern recognition by optical correlation. Each filter was physically limited to only about a radiation of modulation. Researchers have predicted that for low input noise levels, continuous phase-only filters should have a higher absolute correlator peak output than the corresponding binary filters, as well as having a larger SNR. When continuous and binary filters were implemented on the DMD and they exhibited the same performance; an ad hoc filter optimization procedure was developed for use in the laboratory. The optimized continuous filter gave higher correlation peaks than did an independently optimized binary filter. Background behavior in the correlation plane was similar for the two filters, and thus the SNR showed the same improvement for the continuous filter. A phasor diagram analysis and computer simulation have explained part of the optimization procedure's success.

Monroe, Stanley E., Jr.↗

Performance of residual carrier array-feed combining in correlated noise

An array feed combining system for the recovery of signal-to-noise ratio (SNR) loss due to antenna reflector deformation has been implemented and is currently being evaluated on the Jet Propulsion Laboratory's 34-meter DSS-13 antenna. In this system, the defocused signal field captured by a focal plane array feed is recovered using real-time signal-processing and signal-combining techniques. The current signal-processing and signal-combining algorithms are optimum under the assumption that the white Gaussian noise processes in the received signals from different array elements are mutually uncorrelated. Experimental data at DSS 13 indicate that these noise processes are indeed mutually correlated. The main result of this article is an analytical derivation of the actual SNR performance of the current suboptimal signal-combining algorithm in this correlated-noise environment. The analysis here shows that the combined signal SNR can either be improved or degraded depending on the relation between the array signal and noise correlation coefficient phases. Further performance improvement will require the development of signal-combining methods that take into account the correlated noises.

Tan, H. H.↗

Functional Flight Test Report for Positive Systems' ADAR System 5500 Sensor SN8 Linear

This report describes results of the functional flight test conducted with the Positive Systems' ADAR 5500 sensor system (serial number 8, linear configuration) near Winslow, Arizona on June 30 and July 1, 1999. The in-flight test is one component of the NASA Scientific Data Purchase (SDP) Validation and Verification (V&V) process. It allows to measure characteristics of the entire sensor system affected by both performance of the sensor during a flight and post-flight image processing. The following characteristics were analyzed: changes of dark digital numbers (DN's), radiometric linearity, signal-to-noise ratio (SNR), spatial resolution, and geolocation accuracy. The measured characteristics were compared with the image product specifications defined in the Positive Systems' SDP contract. Dependence of the dark DN's on several factors was analyzed, but no significant correlation was found. However, the observed changes in dark DN's were relatively small, which justifies usage of a constant value in the dark DN subtraction procedure during post-processing. Dependence of measured at-sensor, in-band radiance (in arbitrary units) on measured in-band ground reflectance is very well described by a linear function - The sensor fulfills the linearity requirement. Measured SNR values lower than the contract specifications, but accuracy of that test was possibly affected by non-uniformity of the employed gray-scale panels. The SNR values are generally sufficiently high for most applications. SNR can also be improved during standard flights by using longer exposure times. Full width at half maximum (FWHM) of an edge response derived line spread function was used as a measure of spatial resolution. FWHM was generally smaller than twice the ground sample distance (GSD), in agreement with the contract specifications. Accuracy of the geolocation information, which is provided for the particular images in a metadata file, was found to meet contract requirements as well.

Stanley, Tom↗

Performance of Residual Carrier Array Feed Combining in Correlated Noise

An array feed combining system for the recovery of SNR loss due to antenna reflector deformation has been implemented and is currently being evaluated on the Jet Propulsion Laboratory 34 meter DSS-13 antenna. In this system, the defocused signal field captured by a focal plane array feed is recovered using real-time signal processing and signal combining techniques. The current signal processing and signal combining algorithms are optimum under the assumption that the white Gaussian noise processes in the received signals from different array elements are mutually uncorrelated. Experimental data at DSS-13 indicate that these noise processes are indeed mutually correlated. The main result of this paper is an analytical derivation of the actual SNR performance of the current suboptimal signal combining algorithm in this correlated noises environment. The analysis here shows that the combined signal SNR can either be improved or degraded depending on the relation between the array signal and noise correlation coefficient phases. Further performance improvement will require the development of signal combining methods that take into account the correlated noises.

Residual↗

Microwave Photonics for Distributed Sensing

In the past few years, microwave-photonics technologies have been investigated for optical fiber sensing. By introducing microwave modulation into the optical system, the optical detection is synchronized with the microwave modulation frequency. As a result, the system has a high SNR and thus an improved detection limit. In addition, the phase of the microwave-modulated light can be obtained and Fourier transformed to find the time-of-arrival information for distributed sensing. Recently, an incoherent optical-carrier-based microwave interferometry (OCMI) technique has been demonstrated for fully distributed sensing with high spatial resolution and large measurement range. Since the modal interference has little influence on the OCMI signal, the OCMI is insensitive to the types of optical waveguide. Motivated by the eeds of distributed measurement in the harsh environment, in the first part of this paper, several OCMI-based sensing systems were built by using special multimode waveguides to perform sensing for heavy duty applications. Driven by an interest on the high-resolution sensing, in the second part of the paper, I propose a coherence-gated microwave photonics interferometry (CMPI) technique, which uses a coherent light source to obtain the optical interference signal from cascaded weak reflectors. The coherence length of the light source is carefully chosen or controlled to gate the signal so that distributed sensing can be achieved. The experimental results indicate that the strain resolution can be better than 0.6 μ using a Fabry-Perot interferometer (FPI) iii with a cavity length of 1.5 cm. Further improvement of the strain resolution to the 1 n level is achievable by increasing the cavity length of the FPI to over 1m. The CMPI has also been utilized for distributed dynamic measurement of vibration by using a new signal processing method. The fast time-varying optical interference intensity change induced by the sub-scan rate vibration is recorded in the frequency domain. After Fourier transform, distinctive features are shown at the vibration location in the time domain signal, where the vibration frequency and intensity can be retrieved. The signal processing method supports vibration measurement of multiple points with the measurable frequency of up to 20 kHz.

Hua, Liwei↗

Estimating The SNR Of AVIRIS Data

Combination of established statistical and filtering techniques yields improved estimates of signal-to-noise ratio (SNR) of multispectral imagery produced by Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). Method yields more accurate estimate of random variability in AVIRIS imagery. Combination of techniques called "geostatistical" method. In first step of method, periodic noise removed by notch filtering in frequency domain. In subsequent steps, sensor noise and variability within picture elements isolated by use of semi-variance of picture elements.

Curran, Paul J.↗

A Dispersive Backend Design for the 'Double-Fourier' Interferometer BETTII

BETTII (Balloon Experimental Twin Telescope for Infra-red Interferometry) is designed to provide high angular resolution spectroscopic data in the far-infrared (FIR) wavelengths. The most significant limitation for BETTII is its sensitivity; obtaining spectral signal-to-noise ratio greater than 5 in less than 10 minutes requires sources greater than 13 Janskys (Jy). One possible way to improve the signal-to-noise ratio (SNR) for future BETTII flights is by reducing the spectral bandwidth post beam-combination. This involves using a dispersive element to spread out a polychromatic point source PSF (Point Spread Function) on the detector array, such that each pixel corresponds to a small fraction of the bandwidth. This results in a broader envelope of the interferometric fringe pattern allowing more fringes to be detected, and thereby improving the spectral SNR. Here we present the analysis and optical design of the dispersive backend, discussing the tradeoffs and how it can be combined with the existing design.

Dhabal, Arnab↗

Linear Stokes Measurement of Thermal Targets using Compact LWIR Spectropolarimeter

The trade-o↵ between spectral resolution and instrument throughput is analyzed for a compact, uncooled, longwave infrared (LWIR) channeled spectropolarimeter (IRCSP). The IRCSP was developed as a part of the Submm Wave and InfraRed Polarimeters (SWIRP) project out of NASA’s Goddard Spaceflight Center. The IRCSP scientific objective targets measurements of AOLP and DOLP with 1-μm spectral resolution from 8.5 - 12.5 μm in a single snapshot. The geometry of the field stop determines the field of view (FOV) of the IRCSP. This work relates the spectral resolution, instrument throughput, and polarimetric accuracy of a spectro-polarimeter to the FOV. The accuracy of linear Stokes retrievals for low temperature thermal targets are predicted for varying FOV and measurement noise conditions. This work presents a method to quantify the achievable accuracy in AOLP and DOLP as a function of field stop dimensions and signal-to-noise ratio (SNR). While smaller field stops are shown to improve accuracy as the spectral resolution is increased, low SNR is the dominant source of error for the IRCSP prototype. For the IRCSP, a SNR of at least 80 is required to produce DOLP measurements with < 5% error for targets with DOLP < 0.2.

LWIR↗

TEV GAMMA-RAY OBSERVATIONS OF THE GALACTIC CENTER RIDGE BY VERITAS

The Galactic Center ridge has been observed extensively in the past by both GeV and TeV gamma-ray instruments revealing a wealth of structure, including a diffuse component and the point sources G0.9+0.1 (a composite supernova remnant) and Sgr A* (believed to be associated with the supermassive black hole located at the center of our Galaxy). Previous very high energy (VHE) gamma-ray observations with the H.E.S.S. experiment have also detected an extended TeV gamma-ray component along the Galactic plane in the >300 GeV gamma-ray regime. Here we report on observations of the Galactic Center ridge from 2010 to 2014 by the VERITAS telescope array in the >2 TeV energy range. From these observations we (1) provide improved measurements of the differential energy spectrum for Sgr A* in the >2 TeV gamma-ray regime, (2) provide a detection in the >2 TeV gamma-ray emission from the composite SNR G0.9+0.1 and an improved determination of its multi-TeV gamma-ray energy spectrum, and (3) report on the detection of VER J1746-289, a localized enhancement of >2 TeV gamma-ray emission along the Galactic plane.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-F-18C-02: Increasing Amorphous Selenium Thickness in Direct Conversion Flat-Panel Imagers for Contrast-Enhanced Dual-Energy Breast Imaging

Purpose: Contrast-enhanced (CE) breast imaging using iodinated contrast agents requires imaging with x-ray spectra at energies greater than those used in mammography. Optimizing amorphous selenium (a-Se) flat panel imagers (FPI) for this higher energy range may increase lesion conspicuity. Methods: We compare imaging performance of a conventional FPI with 200 μm a-Se conversion layer to a prototype FPI with 300 μm a-Se layer. Both detectors are evaluated in a Siemens MAMMOMAT Inspiration prototype digital breast tomosynthesis (DBT) system using low-energy (W/Rh 28 kVp) and high-energy (W/Cu 49 kVp) x-ray spectra. Detectability of iodinated lesions in dual-energy images is evaluated using an iodine contrast phantom. Effects of beam obliquity are investigated in projection and reconstructed images using different reconstruction methods. The ideal observer signal-to-noise ratio is used as a figure-of-merit to predict the optimal a-Se thickness for CE lesion detectability without compromising conventional full-field digital mammography (FFDM) and DBT performance. Results: Increasing a-Se thickness from 200 μm to 300 μm preserves imaging performance at typical mammographic energies (e.g. W/Rh 28 kVp), and improves the detective quantum efficiency (DQE) for high energy (W/Cu 49 kVp) by 30%. While the more penetrating high-energy x-ray photons increase geometric blur due to beam obliquity in the FPI with thicker a-Se layer, the effect on lesion detectability in FBP reconstructions is negligible due to the reconstruction filters employed. Ideal observer SNR for CE objects shows improvements in in-plane detectability with increasing a-Se thicknesses, though small lesion detectability begins to degrade in oblique projections for a-Se thickness above 500 μm. Conclusion: Increasing a-Se thickness in direct conversion FPI from 200 μm to 300 μm improves lesion detectability in CE breast imaging with virtually no cost to conventional FFDM and DBT. This work was partially supported by a research grant from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An innovative approach for performance enhancement of 320 Gbps free space optical communication system over turbulent channel

Free space optical (FSO) communication systems have recently gained huge attention as possible last mile solution in delivering high speed data services for terrestrial applications. However the FSO link performance, particularly the link range is significantly limited by the severity of atmospheric adversities affecting the channel. In this paper we advocate the use of multi-hop relay techniques to transmit wavelength division multiplexed (WDM) signal over the FSO channel. Since weather induced impairments in FSO links are distance dependent phenomena, hence relay transmission allows substantial performance enhancement by alleviating channel losses while, WDM provides cost effective solution in improving the transmission capacity. With aggregate link losses as high as 40 dB/km, the proposed 32 channel—10 Gbps (320 Gbps) FSO link has been evaluated by comparing bit error rate (BER) performances and eye patterns over different turbulent regimes. Gain optimized EDFA amplification and conventional electrical amplification have been employed to realize amplify-and-forward (A–F) multi-hop transmission in the proposed link with the former delivering more inspiring BER performance of over the latter. Our simulation results indicate that for receiver SNR of 35 dB, BER improvement up to five orders of magnitude can achieved using triple relay FSO link in contrast to direct link operating under similar conditions. Additionally, it is also observed during the analysis that for target BER of 10{sup −5}, incorporation of triple relay enhances the link range by approximately 1200 m over direct link. However on the flip side, our investigations also revealed that as the number of relay nodes is increased, the SNR gain for specified BER does increase but the magnitude of gain declines. The proposed link was designed and investigated using OptiSystem™ 14.2.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Pulsar-Inspired Timing Framework for Power System: Optimization and Performance Evaluation

Due to their excellent stability, neutron pulsar stars are considered promising candidate timing sources for power system applications. However, the complexity of pulsar signals necessitates advanced processing algorithms to provide accurate timing references. This paper presents the foundational framework for pulsar signal processing, serving as the basis for further optimization. To enhance the timing accuracy and computation efficiency in pulsar period searches, three algorithms are proposed as the initial optimization step: wavelet de-noising, fast folding, and cross-correlation for profile evaluation. Wavelet de-noising improves signal-to-noise ratio (SNR) by 36%–70%. Fast folding reduces computation time from hundreds of seconds to mere milliseconds. Cross-correlation works better than traditional SNR-based methods by effectively identifying the optimal period. The performance of the proposed algorithms is evaluated using observation data from telescopes. Together, these algorithms significantly improve pulsar timing performance, reducing the error of the Pulse Per Second (PPS) signal from hundreds to tens of microseconds.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Investigation of energy weighting using an energy discriminating photon counting detector for breast CT

Purpose: Breast CT is an emerging imaging technique that can portray the breast in 3D and improve visualization of important diagnostic features. Early clinical studies have suggested that breast CT has sufficient spatial and contrast resolution for accurate detection of masses and microcalcifications in the breast, reducing structural overlap that is often a limiting factor in reading mammographic images. For a number of reasons, image quality in breast CT may be improved by use of an energy resolving photon counting detector. In this study, the authors investigate the improvements in image quality obtained when using energy weighting with an energy resolving photon counting detector as compared to that with a conventional energy integrating detector.Methods: Using computer simulation, realistic CT images of multiple breast phantoms were generated. The simulation modeled a prototype breast CT system using an amorphous silicon (a-Si), CsI based energy integrating detector with different x-ray spectra, and a hypothetical, ideal CZT based photon counting detector with capability of energy discrimination. Three biological signals of interest were modeled as spherical lesions and inserted into breast phantoms; hydroxyapatite (HA) to represent microcalcification, infiltrating ductal carcinoma (IDC), and iodine enhanced infiltrating ductal carcinoma (IIDC). Signal-to-noise ratio (SNR) of these three lesions was measured from the CT reconstructions. In addition, a psychophysical study was conducted to evaluate observer performance in detecting microcalcifications embedded into a realistic anthropomorphic breast phantom.Results: In the energy range tested, improvements in SNR with a photon counting detector using energy weighting was higher (than the energy integrating detector method) by 30%–63% and 4%–34%, for HA and IDC lesions and 12%–30% (with Al filtration) and 32%–38% (with Ce filtration) for the IIDC lesion, respectively. The average area under the receiver operating characteristic curve (AUC) for detection of microcalcifications was higher by greater than 19% (for the different energy weighting methods tested) as compared to the AUC obtained with an energy integrating detector.Conclusions: This study showed that breast CT with a CZT photon counting detector using energy weighting can provide improvements in pixel SNR, and detectability of microcalcifications as compared to that with a conventional energy integrating detector. Since a number of degrading physical factors were not modeled into the photon counting detector, this improvement should be considered as an upper bound on achievable performance.