Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINDA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evolution and use of combined mechanical and thermal codes for cryogenic turbopump bearings

Shaft bearing system analysis codes were developed, improved, and used to investigate Space Shuttle Main Engine (SSME) Liquid Oxygen (LOX) turbopump bearing problems, and to support the Marshall Space Flight Center Bearing and Seal Materials Test (BSMT) program. Thermal network modeling uses the SINDA thermal code, and the modeling of bearing quasi-dynamic characteristics uses the SHABERTH bearing/shaft code. These codes are solved concurrently for a bearing/shaft system using software developed for this purpose. Simulation of the SSME LOX turbopump turbine and pump end bearings and the MSFC BSMT operating in liquid nitrogen (LN sub 2) and LOX was done. The thermal network models include the bearing components, bearing carriers, shaft, housing, frictional heat, and viscous fluid energy. A cage model was included to account for heat generation between the cage and rolling elements. Since most bearing surfaces operate at temperatures well above the coolant saturation temperature, and move at high speed relative to the coolant, forced convection boiling is the dominant mechanism for heat removal. Improved modeling of forced convection film boiling was incorporated to take into account the local vapor generation at the high temperature surfaces. Rearing preloads in the pump and tester are provided by preload springs. As bearing operating clearances and contact angles change due to thermal effects and loading, the bearing preload changes with these varying conditions. These characteristics were modeled and are included in the overall system models. Results from these models indicate an operational limit which, if exceeded, predicts a thermal excursion.

Cody, Joe C.↗

Optimization of silicon 8 cm x 8 cm wrapthrough Space Station cells for 'on orbit' operation

The optimization of Space Station cells for on-orbit performance is described. Design trades were performed in which back DAR coating thickness was traded against thermal absorptance and performance under front and back (albedo) illumination. Typical examples of modeled cell performance under different scenarios are given. Experimental illuminated output data under back illumination for specific DAR coating thicknesses are also given. Computer modeling of the solar array using TRASYS and SINDA programs also provide on-orbit thermal data and performance predictions. The overall backside response from albedo illumination was found to make a considerable contribution to the total array performance, particularly during the early stages of space station assembly when the arrays are feathered.

Lillington, D. R.↗

Transient analysis of chilldown in a cryogenic transfer line

A numerical model was developed, with the SINDA'85/FLUINT program, for calculating the thermal and hydrodynamic transients that occur during the chilldown of a cryogenic transfer line, using a well documented test case to validate the modeling process. Using this model, a total of ten cases were analyzed to evaluate the effects of variable inlet valve position, inlet pressures, and the use of an internal flow liner to promote nucleate boiling. It was found that an efficient transfer line cooldown can be achieved if the inlet flow is throttled, to reduce the flow rate and quality, and an internal flow liner such as Teflon is used.

Martin, T.↗

Radiation force modeling for the Topex/Poseidon spacecraft

The largest nongravitational forces that will be acting on the Topex satellite will be those due to incident and emitted radiation on the spacecraft surfaces. In order to minimize the effects of these forces on orbit determination, a detailed model is being developed so that they may be accurately predicted. This model requires a precise description of the spacecraft shape and orientation, evaluation of the solar and earth radiation impinging on the surfaces, and a determination of the radiation being emitted from the surfaces as they heat and cool throughout the orbit. The TRASYS software system is used to evaluate the solar and earth radiation striking each surface of the spacecrat. This software has been modified to include an earth radiation model which follows the seasonal variations in albedo and IR radiation. The SINDA software system is then used to determine the transient temperatures of the spacecraft surfaces.

Rosborough, George W.↗

Thermal Radiation Analysis System (TRASYS)

Designed for solar heating design, TRASYS handles partial shading of one surface by another, and translucent surfaces. Runs on DEC computer and generates output compatible with SINDA '85/FLUINT.

Vogt, R. A.↗

Preliminary thermal design of the COLD-SAT spacecraft

The COLD-SAT free-flying spacecraft was to perform experiments with LH2 in the cryogenic fluid management technologies of storage, supply and transfer in reduced gravity. The Phase A preliminary design of the Thermal Control Subsystem (TCS) for the spacecraft exterior and interior surfaces and components of the bus subsystems is described. The TCS was composed of passive elements which were augmented with heaters. Trade studies to minimize the parasitic heat leakage into the cryogen storage tanks are described. Selection procedure for the thermally optimum on-orbit spacecraft attitude was defined. TRASYS-2 and SINDA'85 verification analysis was performed on the design and the results are presented.

Arif, Hugh↗

Sensible heat receiver for solar dynamic space power system

A sensible heat receiver considered in this study uses a vapor grown carbon fiber-carbon (VGCF/C) composite as the thermal storage media and was designed for a 7 kW Brayton engine. The proposed heat receiver stores the required energy to power the system during eclipse in the VGCF/C composite. The heat receiver thermal analysis was conducted through the Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA) software package. The sensible heat receiver compares well with other latent and advanced sensible heat receivers analyzed in other studies while avoiding the problems associated with latent heat storage salts and liquid metal heat pipes. The concept also satisfies the design requirements for a 7 kW Brayton engine system. The weight and size of the system can be optimized by changes in geometry and technology advances for this new material.

Perez-Davis, Marla E.↗

The transient performance of a two-phase fluid reservoir

Thermal control of future large, high power spacecraft will require a two-phase fluid central bus. The two-phase fluid reservoir is a critical component in the two-phase fluid bus. It both controls the saturation temperature and provides a space for volumetric changes. A dynamic reservoir simulation model does not currently exist, but it is needed to expedite efforts and reduce risk. During 1989 an effort was made to develop a simulation model of the transient performance of a two-phase fluid reservoir. As a beginning, a preliminary model was developed. It is based upon component mathematical models in lumped parametric form and build upon five component mathematical models for calculating dynamic responses of two-phase fluid reservoirs, primary feedback elements, controller commands, heater actuators, and reservoir heaters. As much as possible, the model took advantage of the available SINDA'85/FLUINT thermal/fluid integrator. Additional calculation logic and computer subroutines were developed to complete implementation of the model. The model is capable of simulating dynamic response of an equilibrium two-phase fluid reservoir. Modification of the model to include the liquid/vapor nonequilibrium is required for applications of the model to simulate performance of reservoir in which the liquid and vapor phases of the reservoir fluid are not in equilibrium. In addition, the model in its present form, needs to be refined in several respects. More empirical data are needed to guide the model development. The model may then be used to conduct a full parametric study of two-phase fluid reservoirs. More complexities in two-phaes flow regions in laboratory and flight conditions may have to be considered eventually if empirical data cannot be simulated satisfactorily. System with other components arrangement also need to be simulated if optimization is ever to be attained. The present model does, however, preliminarily demonstrates that such analyses are quite possible and offers a far less expensive method to understand the transient of a two-phase fluid reservoir system than a totally headware approach.

Chi, Joseph↗

Preliminary thermal design of the COLD-SAT spacecraft

The COLD-SAT free-flying spacecraft was to perform experiments with LH2 in the cryogenic fluid management technologies of storage, supply and transfer in reduced gravity. The Phase A preliminary design of the Thermal Control Subsystem (TCS) for the spacecraft exterior and interior surfaces and components of the bus subsystems is described. The TCS was composed of passive elements which were augmented with heaters. Trade studies to minimize the parasitic heat leakage into the cryogen storage tanks are described. Selection procedure for the thermally optimum on-orbit spacecraft attitude was defined. TRASYS-2 and SINDA'85 verification analysis was performed on the design and the results are presented.

Arif, Hugh↗

Advanced Communication Technology Satellite (ACTS) multibeam antenna analysis and experiment

One of the most important aspects of a satellite communication system design is the accurate estimation of antenna performance degradation. Pointing error, end coverage gain, peak gain degradation, etc. are the main concerns. The thermal or dynamic distortions of a reflector antenna structural system can affect the far-field antenna power distribution in a least four ways. (1) The antenna gain is reduced; (2) the main lobe of the antenna can be mispointed thus shifting the destination of the delivered power away from the desired locations; (3) the main lobe of the antenna pattern can be broadened, thus spreading the RF power over a larger area than desired; and (4) the antenna pattern sidelobes can increase, thus increasing the chances of interference among adjacent beams of multiple beam antenna system or with antenna beams of other satellites. The in-house developed NASA Lewis Research Center thermal/structural/RF analysis program was designed to accurately simulate the ACTS in-orbit thermal environment and predict the RF antenna performance. The program combines well establish computer programs (TRASYS, SINDA and NASTAN) with a dual reflector-physical optics RF analysis program. The ACTS multibeam antenna configuration is analyzed and several thermal cases are presented and compared with measurements (pre-flight).

Acosta, Roberto J.↗

High temperature furnace modeling and performance verifications

Analytical, numerical, and experimental studies were performed on two classes of high temperature materials processing sources for their potential use as directional solidification furnaces. The research concentrated on a commercially available high temperature furnace using a zirconia ceramic tube as the heating element and an Arc Furnace based on a tube welder. The first objective was to assemble the zirconia furnace and construct parts needed to successfully perform experiments. The 2nd objective was to evaluate the zirconia furnace performance as a directional solidification furnace element. The 3rd objective was to establish a data base on materials used in the furnace construction, with particular emphasis on emissivities, transmissivities, and absorptivities as functions of wavelength and temperature. A 1-D and 2-D spectral radiation heat transfer model was developed for comparison with standard modeling techniques, and were used to predict wall and crucible temperatures. The 4th objective addressed the development of a SINDA model for the Arc Furnace and was used to design sample holders and to estimate cooling media temperatures for the steady state operation of the furnace. And, the 5th objective addressed the initial performance evaluation of the Arc Furnace and associated equipment for directional solidification. Results of these objectives are presented.

Smith, James E., Jr.↗

Thermal modeling of the NASA-Ames Research Center Cryogenic Optical Test Facility and a single-arch, fused-natural-quartz mirror

A thermal model of the dewar and optical system of the Cryogenic Optical Test Facility at NASA-Ames Research Center was developed using the computer codes SINDA and MONTE CARLO. The model was based on the geometry, boundary conditions, and physical properties of the test facility and was developed to investigate heat transfer mechanisms and temperatures in the facility and in test mirrors during cryogenic optical tests. A single-arch, fused-natural-quartz mirror was the first mirror whose thermal loads and temperature distributions were modeled. From the temperature distribution, the thermal gradients in the mirror were obtained. The model predicted that a small gradient should exist for the single arch mirror. This was later verified by the measurement of mirror temperatures. The temperatures, predicted by the model at various locations within the dewar, were in relatively good agreement with the measured temperatures. The model is applicable to both steady-state and transient cooldown operations.

Ng, Y. S.↗

Space Station Freedom main truss thermal analysis

The main truss structure of the Permanently Manned Capability configuration of the Space Station Freedom is analyzed in order to evaluate orbital heating loads and determine the temperature distributions and temperature gradients in the structure. The results are to be utilized in a thermal/structure analysis in the determination of thermal stresses and deflections in the truss members caused by solar heating loads and by shadowing of the truss members by other segments of the Space Station as it moves around the orbit. A SINDA thermal finite different model and a TRASYS radiation interchange model of the truss were generated automatically from a NASTRAN finite element structural model. The analysis yielded transient temperature distribution in the truss structure around the orbit, indicating large temperature gradients in the structure.

Warren, Andrew H.↗

Semi-coupled flow and thermal analysis of the field joint during rapid pressurization of the redesigned solid rocket motor

A transient, semi-coupled, multi-dimensional thermal and flow analysis methodology was developed to predict the thermal/gas dynamic conditions in the field joint region of the Redesigned Solid Rocket Motor (RSRM). Transient temperature response, pressure history, and combustion gas flow rate (within the field joint region), were of principle interest, in the course of this study. The thermal environment in the field joint was modeled using SINDA, a finite difference based thermal network analyzer. The combustion gas flow boundary condition was generated using the FLAP code; this code performs a transient, lumped-parameter, control volume analysis to solve the mass, momentum, and energy conservation equations. The FLAP computer code was modified to account for erosion of the NBR insulation material, following ignition. An independent grid sensitivity study was conducted to determine an appropriate grid distribution near the wall. The predicted results, obtained using an optimum grid distribution and computer generated flow boundary condition, were compared with subscale test data.

Ghaffarian, Benny↗

Hydraulic model of the proposed Water Recovery and Management system for Space Station Freedom

A model of the Water Recovery and Management (WRM) system utilizing SINDA '85/FLUINT to determine its hydraulic operation characteristics, and to verify the design flow and pressure drop parameters is presented. The FLUINT analysis package is employed in the model to determine the flow and pressure characteristics when each of the different loop components is operational and contributing to the overall flow pattern. The water is driven in each loop by storage tanks pressurized with cabin air, and is routed through the system to the desired destination.

Martin, Charles E.↗

Sensible heat receiver for solar dynamic space power system

A sensible heat receiver is considered which uses a vapor grown carbon fiber-carbon (VGCF/C) composite as the thermal storage medium and which was designed for a 7-kW Brayton engine. This heat receiver stores the required energy to power the system during eclipse in the VGCF/C composite. The heat receiver thermal analysis was conducted through the Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA) software package. The sensible heat receiver compares well with other latent and advanced sensible heat receivers analyzed in other studies, while avoiding the problems associated with latent heat storage salts and liquid metal heat pipes. The concept also satisfies the design requirements for a 7-kW Brayton engine system. The weight and size of the system can be optimized by changes in geometry and technology advances for this new material.

Perez-Davis, Marla E.↗

Thermal Radiation Analyzer System (TRASYS)

Working alone or with SINDA '85/FLUINT, TRASYS solves radiation components of thermal analysis problems. Calculates both internode radiation exchange and incident and absorbed heat rate due to sunlight. Used in satellite design, program handles situations where one surface wholly or partially shades another from direct sunlight.

Vogt, R. A.↗

Program Computes Flows Of Fluids And Heat

SINDA'85/FLUINT incorporates lumped-parameter-network and one-dimensional-flow mathematical models. System enables analysis of mutual influences of thermal and flow phenomena. Offers two finite-difference numerical solution techniques: forward-difference explicit approximation and Crank-Nicholson approximation. Enables simulation of nonuniform heating and facilitates mathematical modeling of thin-walled heat exchangers. Ability to model nonequilibrium behavior within two-phase volumes included. Recent changes in program improve modeling of real evaporator pumps and other capillary-assist evaporators. Written in FORTRAN 77.

Cullimore, Brent↗