At least 109 records · Page 6

Inflight Treadmill Exercise Can Serve as Multi-Disciplinary Countermeasure System

The goals of the Functional Task Test (FTT) study were to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. Ultimately this information will be used to assess performance risks and inform the design of countermeasures for exploration class missions. We have previously shown that for Shuttle, ISS and bed rest subjects, functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for postural stability (i.e. hatch opening, ladder climb, manual manipulation of objects and tool use) showed little reduction in performance. These changes in functional performance were paralleled by similar decrements in sensorimotor tests designed to specifically assess postural equilibrium and dynamic gait control. The bed rest analog allows us to investigate the impact of axial body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance and then compare them with the results obtained in our space flight study. These results indicate that body support unloading experienced during space flight plays a central role in postflight alteration of functional task performance. These data also support the concept that space flight may cause central adaptation of converging body-load somatosensory and vestibular input during gravitational transitions [1]. Therefore, we conclude that providing significant body-support loading during inflight treadmill along with balance training is necessary to mitigate decrements in critical mission tasks that require dynamic postural stability and mobility. Data obtained from space flight and bed rest support the notion that in-flight treadmill exercise, in addition to providing aerobic exercise and mechanical stimuli to the bone, also has a number of sensorimotor benefits by providing: 1) A balance challenge during locomotion requiring segmental coordination in response to a downward force. 2) Body-support loading during performance of a full-body active motor task. 3) Oscillatory stimulation of the otoliths and synchronized periodic foot impacts that facilitate the coordination of gait motions and tune the full-body gaze control system. 4) Appropriate sensory input (foot tactile input, muscle and tendon stretch input) to spinal locomotor central pattern generators required for the control of locomotion. Forward work will focus on a follow-up bed rest study that incorporates aerobic and resistance exercise with a treadmill balance and gait training system that can serve as an integrated interdisciplinary countermeasure system for future exploration class missions.

Bloomberg, J. J.↗

The persistence of a visual dominance effect in a telemanipulator task: A comparison between visual and electrotactile feedback

The possibility to use an electrotactile stimulation in teleoperation and to observe the interpretation of such information as a feedback to the operator was investigated. It is proposed that visual feedback is more informative than an electrotactile one; and that complex electrotactile feedback slows down both the motor decision and motor response processes, is processed as an all or nothing signal, and bypasses the receptive structure and accesses directly in a working memory where information is sequentially processed and where memory is limited in treatment capacity. The electrotactile stimulation is used as an alerting signal. It is suggested that the visual dominance effect is the result of the advantage of both a transfer function and a sensory memory register where information is pretreated and memorized for a short time. It is found that dividing attention has an effect on the acquisition of the information but not on the subsequent decision processes.

Gaillard, J. P.↗

Vestibular responses to linear acceleration are absent in otoconia-deficient C57BL/6JEi-het mice

Vestibular evoked potentials (VsEPs) were measured in normal mice and in mice homozygous for the head tilt mutation (het/het, abbr. het). The het mice lack otoconia, the inertial mass critical for natural stimulation of inner ear gravity receptors. Our findings demonstrate that vestibular neural responses to pulsed linear acceleration are absent in het mice. The results: (1) confirm that adequate sensory stimuli fail to activate gravity receptors in the het model; and (2) serve as definitive evidence that far-field vestibular responses to pulsed linear acceleration depend critically on otolith end organs. The C57BL/6JEi-het mouse may be an excellent model of gravity receptor sensory deprivation.

NASA Discipline Neuroscience↗

Statoconia formation in molluscan statocysts

The gravity sensors of all molluscs phylogenetically below the cephalopods are spherical organs called statocysts. The wall of the sphere contains mechanosensory cells whose sensory cilia project into the lumen of the cyst. The lumen is filled with fluid and dense "stones", the statoconia or statoliths, which sink under the influence of gravity to load, and stimulate, those receptor cells which are at the bottom. The statoconia of Aplysia californica are shown to be calcified about a lamellar arrangement of membranes. Similar lamellar membrane arrangements are seen within the receptor cells, and their possible role in the formation of the statoconia is discussed. SEM of unfixed statoconia reveals plate-like crystallization on their surface. Elemental analysis shows a relatively high Sr content, which is of interest, since others have recently reported that Sr is required in the culture medium of several laboratory reared molluscs in order for the statoconia to develop.

Non-NASA Center↗

Tactile responses in the granule cell layer of cerebellar folium crus IIa of freely behaving rats

We recorded activity from the granule cell layer (GCL) of cerebellar folium Crus IIa as freely moving rats engaged in a variety of natural behaviors, including grooming, eating, and free tactile exploration. Multiunit responses in the 1000-4500 Hz range were found to be strongly correlated with tactile stimulation of lip and whisker (perioral) regions. These responses occurred regardless of whether the stimulus was externally or self-generated and during both active and passive touch. In contrast, perioral movements that did not tactually stimulate this region of the face (e.g., chewing) produced no detectable increases in GCL activity. In addition, GCL responses were not correlated with movement extremes. When rats used their lips actively for palpation and exploration, the tactile responses in the GCL were not detectably modulated by ongoing jaw movements. However, active palpation and exploratory behaviors did result in the largest and most continuous bursts of GCL activity: responses were on average 10% larger and 50% longer during palpation and exploration than during grooming or passive stimulation. Although activity levels differed between behaviors, the position and spatial extent of the peripheral receptive field was similar over all behaviors that resulted in tactile input. Overall, our data suggest that the 1000-4500 Hz multiunit responses in the Crus IIa GCL of awake rats are correlated with tactile input rather than with movement or any movement parameter and that these responses are likely to be of particular importance during the acquisition of sensory information by perioral structures.

Neurons/cytology/physiology↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain's ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable and provides imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles. SR using imperceptible stochastic electrical stimulation of the vestibular system (stochastic vestibular stimulation, SVS) applied to normal subjects has shown to improve the degree of association between the weak input periodic signals introduced via venous blood pressure receptors and the heart-rate responses. Also, application of SVS over 24 hours improves the long-term heart-rate dynamics and motor responsiveness as indicated by daytime trunk activity measurements in patients with multi-system atrophy, Parkinson s disease, or both, including patients who were unresponsive to standard therapy for Parkinson s disease. Recent studies conducted at the NASA JSC Neurosciences Laboratories showed that imperceptible SVS, when applied to normal young healthy subjects, leads to significantly improved balance performance during postural disturbances on unstable compliant surfaces. These studies have shown the benefit of SR noise characteristic optimization with imperceptible SVS in the frequency range of 0-30 Hz, and amplitudes of stimulation have ranged from 100 to 400 microamperes.

Bloomberg, Jacob↗

Improving Balance Function Using Low Levels of Electrical Stimulation of the Balance Organs

Crewmembers returning from long-duration space flight face significant challenges due to the microgravity-induced inappropriate adaptations in balance/ sensorimotor function. The Neuroscience Laboratory at JSC is developing a method based on stochastic resonance to enhance the brain s ability to detect signals from the balance organs of the inner ear and use them for rapid improvement in balance skill, especially when combined with balance training exercises. This method involves a stimulus delivery system that is wearable/portable providing imperceptible electrical stimulation to the balance organs of the human body. Stochastic resonance (SR) is a phenomenon whereby the response of a nonlinear system to a weak periodic input signal is optimized by the presence of a particular non-zero level of noise. This phenomenon of SR is based on the concept of maximizing the flow of information through a system by a non-zero level of noise. Application of imperceptible SR noise coupled with sensory input in humans has been shown to improve motor, cardiovascular, visual, hearing, and balance functions. SR increases contrast sensitivity and luminance detection; lowers the absolute threshold for tone detection in normal hearing individuals; improves homeostatic function in the human blood pressure regulatory system; improves noise-enhanced muscle spindle function; and improves detection of weak tactile stimuli using mechanical or electrical stimulation. SR noise has been shown to improve postural control when applied as mechanical noise to the soles of the feet, or when applied as electrical noise at the knee and to the back muscles.

Bloomberg, Jacob↗

Effects of microgravity on the interaction of vestibular and optokinetic nystagmus in the vertical plane

The extent to which the slow phase velocity (SPV) of nystagmus elicited by a vertical optokinetic stimulation with constant velocity could be modulated by sinusoidal angular motion in the vertical plane was investigated under normal gravity condition and during the microgravity period of parabolic flight. In normal gravity, when the angular head motion and the optokinetic stimulation were in the same direction, the peak SPV was slower than the velocity of the optokinetic display. When the head motion and the optokinetic stimulation were in opposite directions, the peak SPV was equal to the velocity of the optokinetic display. In microgravity, the peak SPV was approximately equal to the velocity of the optokinetic display when head rotation and optokinetic stimulation were in the same direction, and was faster than the velocity of the optokinetic dispaly when head rotation and optokinetic stimulation were in opposite directions. In addition, the interaction of vestibular and optokinetic nystagmus was found to be nonlinear in microgravity, especially when the optokinetic stimulation was directed downward. These results suggest an interaction between the vestibular and the optokinetic systems modulated as a function of the gravitational state, and support the observation that visual input is more effective in reducing sensory conflict experienced in microgravity.

Clement, Gilles↗

Recovery of postural equilibrium control following space flight

DSO 605 represents the first large study of balance control following spaceflight. Data collected during DSO 605 confirm the theory that postural ataxia following short duration spaceflight is of vestibular origin. We used the computerized dynamic posturography technique developed by Nashner et al. to study the role of the vestibular system in balance control in astronauts during quiet stance before and after spaceflight. Our results demonstrate unequivocally that balance control is disrupted in all astronauts immediately after return from space. The most severely affected returning crew members performed in the same way as vestibular deficient patients exposed to this test battery. We conclude that otolith mediated spatial reference provided by the terrestrial gravitational force vector is not used by the astronauts balance control systems immediately after spaceflight. Because the postflight ataxia appears to be mediated primarily by CNS adaptation to the altered vestibular inputs caused by loss of gravitational stimulation, we believe that intermittent periods of exposure to artificial gravity may provide an effective in-flight countermeasure. Specifically, we propose that in-flight centrifugation will allow crew members to retain their terrestrial sensory-motor adapted states while simultaneously developing microgravity adapted states. The dual-adapted astronaut should be able to make the transition from microgravity to unit gravity with minimal sensory-motor effects. We have begun a ground based program aimed at developing short arm centrifuge prescriptions designed to optimize adaptation to altered gravitational environments. Results from these experiments are expected to lead directly to in-flight evaluation of the proposed centrifuge countermeasure. Because our computerized dynamic posturography system was able to (1) quantify the postflight postural ataxia reported by crew members and observed by flight surgeons and scientists, (2) track the recovery of normal (preflight) balance control, (3) differentiate between rookie and veteran subjects, and (4) provide normative and clinical databases for comparison, and because our study successfully characterized postflight balance control recovery in a large cross-section of Shuttle crew members, we recommend that this system and protocol be adopted as a standard dependent measure for evaluating the efficacy of countermeasures and/or evaluating the postflight effects of changing mission durations or activities.

Paloski, William H.↗

Some influences of touch and pressure cues on human spatial orientation

In order to evaluate the influences of touch and pressure cues on human spatial orientation, blindfolded subjects were exposed to 30 rmp rotation about the Z-axis of their bodies while the axis was horizontal or near horizontal. It was found that the manipulation of pressure patterns to which the subjects are exposed significantly influences apparent orientation. When provided with visual information about actual orientation the subjects will eliminate the postural illusions created by pressure-cue patterns. The localization of sounds is dependent of the apparent orientation and the actual pattern of auditory stimulation. The study provides a basis for investigating: (1) the postural illusions experienced by astronauts in orbital flight and subjects in the free-fall phase of parabolic flight, and (2) the spatial-constancy mechanisms distinguishing changes in sensory afflux conditioned by a subject's movements in relation to the environment, and those conditioned by movements of the environment.

Lackner, J. R.↗

The effect of attention loading on the inhibition of choice reaction time to visual motion by concurrent rotary motion

This study investigates the influence of attention loading on the established intersensory effects of passive bodily rotation on choice reaction time (RT) to visual motion. Subjects sat at the center of rotation in an enclosed rotating chamber and observed an oscilloscope on which were, in the center, a tracking display and, 10 deg left of center, a RT line. Three tracking tasks and a no-tracking control condition were presented to all subjects in combination with the RT task, which occurred with and without concurrent cab rotations. Choice RT to line motions was inhibited (probability less than .001) both when there was simultaneous vestibular stimulation and when there was a tracking task; response latencies lengthened progressively with increased similarity between the RT and tracking tasks. However, the attention conditions did not affect the intersensory effect; the significance of this for the nature of the sensory interaction is discussed.

Looper, M.↗

Gravity, light and plant form

Plants have evolved highly sensitive and selective mechanisms that detect and respond to various aspects of their environment. As a plant develops, it integrates the environmental information perceived by all of its sensory systems and adapts its growth to the prevailing environmental conditions. Light is of critical importance because plants depend on it for energy and, thus, survival. The quantity, quality and direction of light are perceived by several different photosensory systems that together regulate nearly all stages of plant development, presumably in order to maintain photosynthetic efficiency. Gravity provides an almost constant stimulus that is the source of critical spatial information about its surroundings and provides important cues for orientating plant growth. Gravity plays a particularly important role during the early stages of seedling growth by stimulating a negative gravitropic response in the primary shoot that orientates it towards the source of light, and a positive gravitropic response in the primary root that causes it to grow down into the soil, providing support and nutrient acquisition. Gravity also influences plant form during later stages of development through its effect on lateral organs and supporting structures. Thus, the final form of a plant depends on the cumulative effects of light, gravity and other environmental sensory inputs on endogenous developmental programs. This article is focused on developmental interactions modulated by light and gravity.

NASA Discipline Plant Biology↗

Differences in Otolith and Abdominal Viscera Graviceptor Dynamics: Implications for Motion Sickness and Perceived Body Position

Human graviceptors, located in the trunk by Mittelstaedt probably transduce acceleration by abdominal viscera motion. As demonstrated previously in biodynamic vibration and impact tolerance research the thoraco-abdominal viscera exhibit a resonance at 4 to 6 Hz. Behavioral observations and mechanical models of otolith graviceptor response indicate a phase shift increasing with frequency between 0.01 and O.5 Hz. Consequently the potential exists for intermodality sensory conflict between vestibular and visceral graviceptor signals at least at the mechanical receptor level. The frequency range of this potential conflict corresponds with the primary frequency range for motion sickness incidence in transportation, in subjects rotated about Earth-horizontal axes (barbecue spit stimulation) and in periodic parabolic flight microgravity research and also for erroneous perception of vertical oscillations in helicopters. We discuss the implications of this hypothesis for previous self motion perception research and suggestions for various future studies.

vonGierke, Henning E.↗

Space adaptation syndrome: multiple etiological factors and individual differences

Space motion sickness is a significant operational concern in the American and Soviet space programs. Nearly 70% of all astronauts and cosmonauts are affected to some degree during their first several days of flight. It is now beginning to appear that space motion sickness like terrestrial motion sickness is the consequence of multiple etiological factors. As we come to understand basic mechanisms of spatial orientation and sensory-motor adaptation we can begin to predict etiological factors in different motion environments. Individuals vary greatly in the extent to which they are susceptible to these different factors. However, individuals seem to be relatively self-consistent in terms of their rates of adaptation to provocative stimulation and their retention of adaptation. Attempts to relate susceptibility to motion sickness during the microgravity phases of parabolic flight maneuvers to vestibular function under 1G and 0G test conditions are described.

short duration↗

Sensory, motor, and combined contexts for context-specific adaptation of saccade gain in humans

Saccadic eye movements can be adapted in a context-specific manner such that their gain can be made to depend on the state of a prevailing context cue. We asked whether context cues are more effective if their nature is primarily sensory, motor, or a combination of sensory and motor. Subjects underwent context-specific adaptation using one of three different context cues: a pure sensory context (head roll-tilt right or left); a pure motor context (changes in saccade direction); or a combined sensory-motor context (head roll-tilt and changes in saccade direction). We observed context-specific adaptation in each condition; the greatest degree of context-specificity occurred in paradigms that used the motor cue, alone or in conjunction with the sensory cue. Copyright 2002 Elsevier Science Ireland Ltd.

NASA Discipline Neuroscience↗

Developing An Earth-Fixed Visual Reference to Aid Stability, Readaptation and Egress After a Water Landing

INTRODUCTION Water landings present the worst possible sensory conditions for crews trying to orient and stabilize themselves immediately after long-duration spaceflight. Of the three sensory feedback systems involved in maintaining stability (i.e., proprioceptive, vestibular, and visual), none will provide reliable orientation information under the current water landing scenarios. The proprioceptive and vestibular systems are affected during spaceflight by disuse and adaptation to microgravity. Vision may not suffer the same degradation, but the visual environment within the enclosed space of a capsule, or interior room of a recovery ship, is disorienting when subject to wave-induced motion. The result is an increased risk of fall-related injury. In a prior study, 70% (21 of 30) of nonimpaired subjects reported that the presence of an Earth-fixed horizontal line helped them stabilize when their visually enclosed environment was exposed to wave motion. In addition to aiding stability, sensory re-adaptation occurs when inputs from the three sensory systems are synchronized with one another and aligned with Earth’s gravity. The earlier an Earth-fixed visual reference can be introduced the sooner the readaptation process can begin. The goal of this project is to identify the optimal features of a device that visually presents gravitational reference cues to support stability and readaptation. METHODS The capsule sensory-condition simulator is a three-sided enclosure atop a six degree-of-freedom motion platform. A sum-of-sines equation is used to drive the motion platform, producing the simulated wave motion. The equation was derived using the frequency range present in inertial measurement unit (IMU) data collected during open-water Orion mock-up testing. The enclosure creates the nature of a floating visual environment where the walls move in relation to the standing surface. To more accurately represent the condition of postflight crewmembers, galvanic vestibular stimulation (GVS) is applied to disrupt normal vestibular function and standing on a compliant surface attenuates proprioceptive feedback. An instrumented handhold allows the subjects to stabilize themselves and serves as the primary dependent variable. Subjects are instructed to minimize handhold use so the higher forces applied to the handhold correspond to greater instability. Various forms of a visual reference have been explored. Passive systems, such as mechanical gimbals and weighted plumb bobs were eliminated from consideration because of the intertia-induced oscillations that the wave-motion causes. Laser lines presented as horizontal, vertical, or the combination of both are being used to provide the Earth-fixed visual reference. These are presented in the central visual field or periphery from laser sources that are mounted either from within or outside the visual enclosure. RESULTS Data collection for this study is currently in progress. CONCLUSIONS This study will determine whether a visual reference system can help improve stability during challenging sensory conditions and define the optimal chacteristics for such a system.

Brian T Peters↗

Spaceflight Sensorimotor Analogs: Simulating Acute and Adaptive Effects

Adaptive changes in sensorimotor function during spaceflight are reflected by spatial disorientation, motion sickness, gaze destabilization and decrements in balance, locomotion and eye-hand coordination that occur during and following transitions between different gravitational states. The purpose of this study was to conduct a meta-synthesis of data from spaceflight analogs to evaluate their effectiveness in simulating adaptive changes in sensorimotor function. METHODS. The analogs under review were categorized as either acute analogs used to simulate performance decrements accompanied with transient changes, or adaptive analogs used to drive sensorimotor learning to altered sensory feedback. The effectiveness of each analog was evaluated in terms of mechanisms of action, magnitude and time course of observed deficits compared to spaceflight data, and the effects of amplitude and exposure duration. RESULTS. Parabolic flight has been used extensively to examine effects of acute variation in gravitational loads, ranging from hypergravity to microgravity. More recently, galvanic vestibular stimulation has been used to elicit acute postural, locomotor and gaze dysfunction by disrupting vestibular afferents. Patient populations, e.g., with bilateral vestibular loss or cerebellar dysfunction, have been proposed to model acute sensorimotor dysfunction. Early research sponsored by NASA involved living onboard rotating rooms, which appeared to approximate the time course of adaptation and post-exposure recovery observed in astronauts following spaceflight. Exposure to different bed-rest paradigms (6 deg head down, dry immersion) result in similar motor deficits to that observed following spaceflight. Shorter adaptive analogs have incorporated virtual reality environments, visual distortion paradigms, exposure to conflicting tilt-translation cues, and exposure to 3Gx centrifugation. As with spaceflight, there is considerable variability in responses to most of the analogs reviewed. DISCUSSION. A true ground-based flight analog for sensorimotor function is not feasible. A combination of flight analogs; however, can be used to selectively mimic different aspects of the spaceflight-induced sensorimotor performance decrements.

Taylor, Laura C.↗