Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigation of orientation inhomogeneities in polycrystalline materials by means of FEG-SEM, FIB, EBSD and 3-D reconstruction

The efficiency of different techniques application for the investigation of orientation inhomogeneities in polycrystalline materials was studied using FEG SEM-FIB dual beam station equipped with EBSD. It is shown that for the visualization of pearlitic ferrite fragments it is more appropriate to acquire the images in secondary electrons induced by Ga ions. At the same time for the visualization of nano-sized particles it is more prospective to use images in forward scatter electrons in combination with IQ maps. It is established that pearlitic ferrite fragments are not flat. Complicated spatial configuration of orientation inhomogeneities in pearlitic ferrite is shown by means of 3-d reconstruction. The features of ferrites aggregation are revealed depending on pearlitic ferrite fragmentation criterion. The existence of long-range misorientations in the aggregation area of proeutectoid and pearlitic ferrites is shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SEM, Chemical Etching and THz Wave Generation of 4-Dimethylamino-N-methyl-4-stilbazolium Tosylate (DAST) Single Crystals

The 4-dimethylamino-N-methyl-4-stilbazolium tosylate (DAST) crystal which was candidate for generating and detecting terahertz (THz) wave was grown by slope nucleation method (SNM). The functional groups of DAST were identified by Fourier Transform Infrared (FTIR) studies. Macroscopic steps and streaks on the (001) face were found by scanning electron microscope (SEM). Different patterns of etch pits under different chemical etchants were studied by optical microscope. Widely tunable THz waves ranging from 0.38 to 18.10 THz were generated from 0.5 mm-thick DAST crystal. The maximum output energy was 345.4 nJ/pulse at 3.39 THz and the conversion efficiency was 8.44 × 10{sup –5}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEM in situ MiniCantilever Beam Bending of U-10Mo/Zr/Al Fuel Elements

In this work, the fracture behavior of Al/Zr and Zr/dU-10Mo interfaces was measured via the minicantilever bend technique. The energy dissipation rates were found to be approximately 3.7-5 mj/mm 2 and 5.9 mj/mm 2 for each interface, respectively. It was found that in order to test the Zr/U-10Mo interface, location of the hinge of the cantilever was a key parameter. While this test could be adapted to hot cell use through careful alignment fixturing and measurement of crack lengths with an optical microscope (as opposed to SEM, which was used here out of convenience), machining of the cantilevers via MiniMill in such a way as to locate the interfaces at the cantilever hinge, as well as proper placement of a femtosecond laser notch will continue to be key challenges in a hot cell environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-stress study of bioinspired multifunctional PEDOT:PSS/nanoclay nanocomposites using AFM, SEM and numerical simulation

Bioinspired design has been central in the development of hierarchical nanocomposites. Particularly, the nacre-mimetic brick-and-mortar structure has shown excellent mechanical properties, as well as gas-barrier properties and optical transparency. Along with these intrinsic properties, the layered structure has also been utilized in sensing devices. Here we extend the multifunctionality of nacre-mimetics by designing an optically transparent and electron conductive coating based on PEDOT:PSS and nanoclays Laponite RD and Cloisite Na + . We carry out extensive characterization of the nanocomposite using transmittance spectra (trans-parency), conductive atomic force microscopy (conductivity), contact-resonance force microscopy (mechanical properties), and SEM combined with a variety of stress-strain AFM experiments and AFM numerical simulations (internal structure). We further study the nanoclay’s response to the application of pressure with multifrequency AFM and conductive AFM, whereby increases and decreases in conductivity can occur for the Laponite RD composites. We offer a possible mechanism to explain the changes in conductivity by modeling the coating as a 1-dimensional multibarrier potential for electron transport, and show that conductivity can change when the separation between the barriers changes under the application of pressure, and that the direction of the change depends on the energy of the electrons. We did not observe changes in conductivity under the application of pressure with AFM for the Cloisite Na+ nanocomposite, which has a large platelet size compared with the AFM probe diameter. No pressure-induced changes in conductivity were observed in the clay-free polymer either.

59 BASIC BIOLOGICAL SCIENCES↗

SCILLA Scanning Electrical Mobility Spectrometer (SEMS) airborne data

The Scanning Electrical Mobility Spectrometer (SEMS) provides measurements of bulk aerosol size distributions, which are crucial for studying aerosol-cloud interactions. The instrument sampled through two different inlets: an isokinetic inlet and a counter-flow virtual impactor (CVI) inlet. Data were collected to help improve climate and earth systems models, characterize atmospheric conditions, and validate satellite observations and climate simulations.

Scanning Electrical Mobility Spectrometer↗

Microcircuit failure analysis using the SEM

The scanning electron microscope adds a new dimension to the knowledge that can be obtained from a failed microcircuit. When used with conventional techniques, SEM assists and clarifies the analysis, but it does not replace light microscopy. The most advantageous features for microcircuit analysis are long working distances and great depth of field. Manufacturer related failure modes of microcircuits are metallization defects, poor bonding, surface and particle contamination, and design and fabrication faults. User related failure modes are caused by abuse, such as overstress. The Physics of Failure Procedure followed by the Astrionics Laboratory in failure analysis is described, which is designed to obtain maximum information available from each step.

Nicolas, D. P.↗

Study of SEM induced current and voltage contrast modes to assess semiconductor reliability

The purpose of the scanning electron microscopy study was to review the failure history of existing integrated circuit technologies to identify predominant failure mechanisms, and to evaluate the feasibility of their detection using SEM application techniques. The study investigated the effects of E-beam irradiation damage and contamination deposition rates; developed the necessary methods for applying the techniques to the detection of latent defects and weaknesses in integrated circuits; and made recommendations for applying the techniques.

Beall, J. R.↗

SEM probe of IC radiation sensitivity

Scanning Electron Microscope (SEM) used to irradiate single integrated circuit (IC) subcomponent to test for radiation sensitivity can localize area of IC less than .03 by .03 mm for determination of exact location of radiation sensitive section.

Gauthier, M. K.↗

Analysis of the interaction of an electron beam with a solar cell. III - The effect of spacial variations of the number density of recombination centers on SEM measurements

By means of an exactly soluble model the short circuit current generated by a scanning electron microscope in a P-N junction has been determined in cases where the trap density is inhomogeneous. The diffusion length for minority carriers becomes then dependent on the spacial coordinates. It is shown that in this case the dependence of the Isc on characteristic parameters as cell thickness, distance of the beam excitation spot from ohmic contacts, etc., becomes very intricate. This fact precludes the determination of the local diffusion length in the usual manner. Although the model is somewhat simplified in order to make it amenable to exact solutions, it is nevertheless realistic enough to lead to the conclusion that SEM measurements of bulk transport parameters in inhomogeneous semiconductor material are impractical since they may lead to serious errors in the interpretation of the data by customary means.

Von Roos, O.↗

Viewing Integrated-Circuit Interconnections By SEM

Back-scattering of energetic electrons reveals hidden metal layers. Experiment shows that with suitable operating adjustments, scanning electron microscopy (SEM) used to look for defects in aluminum interconnections in integrated circuits. Enables monitoring, in situ, of changes in defects caused by changes in temperature. Gives truer picture of defects, as etching can change stress field of metal-and-passivation pattern, causing changes in defects.

Lawton, Russel A.↗

Mechanical and SEM analysis of artificial comet nucleus samples

Since 1987 experiments dealing with comet nucleus phenomena have been carried out in the DFVLR space simulation chambers. The main objective of these experiments is a better understanding of thermal behavior, surface phenomena and especially the gas dust interaction. As a function of different sample compositions and exposure to solar irradiation (xenon-bulbs) crusts of different hardness and thickness were measured. The measuring device consists of a motor driven pressure foot (5 mm diameter), which is pressed into the sample. The applied compressive force is electronically monitored. The microstructure of the crust and dust residuals is investigated by scanning electron microscopy (SEM) techniques. Stress-depth profiles of an unirradiated and an irradiated model comet are given.

Thiel, K.↗

In situ SEM thermal fatigue of Al/graphite metal matrix composites

Several thermal fatigue-induced failure mechanisms are deduced for unidirectional graphite-reinforced 6061 Al-alloy MMCs subjected to in situ thermal cycling. These thermal cycling conditions are representative of MMC service cycles in aerospace environments, where thermal fatigue is primarily associated with changes in the stress states near the interfaces due to coefficient of thermal expansion mismatch between fiber and matrix. This in situ SEM thermal-cycling study clarified such factors affecting MMCs' thermal fatigue as local fiber content and distribution, void volume, fiber stiffness, thermal excursion magnitude, and number of thermal cycles. MMC microfailure modes in thermal fatigue have been deduced.

Zong, G. S.↗

SEMS: System for Environmental Monitoring and Sustainability

The goal of this project was to establish a computational and data management system, SEMS, building on our existing system and MTPE-related research. We proposed that the new system would help support Washington University's efforts in environmental sustainability through use in: (a) Problem-based environmental curriculum for freshmen and sophomores funded by the Hewlett Foundation that integrates scientific, cultural, and policy perspectives to understand the dynamics of wetland degradation, deforestation, and desertification and that will develop policies for sustainable environments and economies; (b) Higher-level undergraduate and graduate courses focused on monitoring the environment and developing policies that will lead to sustainable environmental and economic conditions; and (c) Interdisciplinary research focused on the dynamics of the Missouri River system and development of policies that lead to sustainable environmental and economic floodplain conditions.

Arvidson, Raymond E.↗

Automated SEM Modal Analysis Applied to the Diogenites

Analysis of volume proportions of minerals, or modal analysis, is routinely accomplished by point counting on an optical microscope, but the process, particularly on brecciated samples such as the diogenite meteorites, is tedious and prone to error by misidentification of very small fragments, which may make up a significant volume of the sample. Precise volume percentage data can be gathered on a scanning electron microscope (SEM) utilizing digital imaging and an energy dispersive spectrometer (EDS). This form of automated phase analysis reduces error, and at the same time provides more information than could be gathered using simple point counting alone, such as particle morphology statistics and chemical analyses. We have previously studied major, minor, and trace-element chemistry of orthopyroxene from a suite of diogenites. This abstract describes the method applied to determine the modes on this same suite of meteorites and the results of that research. The modal abundances thus determined add additional information on the petrogenesis of the diogenites. In addition, low-abundance phases such as spinels were located for further analysis by this method.

Bowman, L. E.↗

SEM visualization of glycosylated surface molecules using lectin-coated microspheres

There are several techniques currently used to localize glycosylated surface molecules by scanning electron microscopy (Grinnell, 1980; Molday, 1976; Linthicum and Sell, 1975; Nicolson, 1974; Lo Buglio, et al, 1972). A simple and rapid method, using a modification of Grinnell's technique is reported here. Essentially, microspheres coated with Concavalin A are used to bind to glycosylated regions of the palatal shelf epithelium and are visualized in the scanning electron microscope (SEM).

Non-NASA Center↗

Low cost environmental sensors for Spaceflight : NMP Space Environmental Monitor (SEM) requirements

An outstanding problem in spaceflight is the lack of adequate sensors for monitoring the space environment and its effects on engineering systems. By adequate, we mean low cost in terms of mission impact (e.g., low price, low mass/size, low power, low data rate, and low design impact). The New Millennium Program (NMP) is investigating the development of such a low-cost Space Environmental Monitor (SEM) package for inclusion on its technology validation flights. This effort follows from the need by NMP to characterize the space environment during testing so that potential users can extrapolate the test results to end-use conditions. The immediate objective of this effort is to develop a small diagnostic sensor package that could be obtained from commercial sources. Environments being considered are: contamination, atomic oxygen, ionizing radiation, cosmic radiation, EMI, and temperature. This talk describes the requirements and rational for selecting these environments and reviews a preliminary design that includes a micro-controller data logger with data storage and interfaces to the sensors and spacecraft. If successful, such a sensor package could be the basis of a unique, long term program for monitoring the effects of the space environment on spacecraft systems.

Galileo↗

SEM-EDS Analyses of Small Craters in Stardust Aluminum Foils: Implications for the Wild-2 Dust Distribution

Aluminium foils were used on Stardust to stabilize the aerogel specimens in the modular collector tray. Part of these foils were fully exposed to the flux of cometary grains emanating from Wild 2. Because the exposed part of these foils had to be harvested before extraction of the aerogel, numerous foil strips some 1.7 mm wide and 13 or 33 mm long were generated during Stardusts's Preliminary Examination (PE). These strips are readily accommodated in their entirety in the sample chambers of modern SEMs, thus providing the opportunity to characterize in situ the size distribution and residue composition - employing EDS methods - of statistically more significant numbers of cometary dust particles compared to aerogel, the latter mandating extensive sample preparation. We describe here the analysis of nearly 300 impact craters and their implications for Wild 2 dust.

Borg, J.↗