Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of AGS E880 polarimeter data at Gγ = 12.5

Data were collected with the AGS internal (E880) polarimeter at Gγ = 12.5 during the FY04 polarized proton run. Measurements were made with forward scintillation counters in coincidence with recoil counter telescopes, permitting an absolute calibration of the polarimeter for both nylon and carbon targets. The results are summarized and they will also be useful for an absolute calibration of the AGS CNI polarimeter at Gγ = 12.5.

43 PARTICLE ACCELERATORS↗

Analysis of AGS E880 polarimeter data at G$_\gamma$ = 12.5.

Data were collected with the AGS internal (E880) polarimeter at G$_\gamma$ = 12.5 during the FY04 polarized proton run. Measurements were made with forward scintillation counters in coincidence with recoil counter telescopes, permitting an absolute calibration of the polarimeter for both nylon and carbon targets. The results are summarized and they will also be useful for an absolute calibration of the AGS CNI polarimeter at G$_\gamma$ = 12.5.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research and Development for the Mu2e Extinction Monitor

Mu2e is a planned experiment to search for flavor-violating conversion from a muon to an electron. The experiment will use a pulsed 8 GeV proton beam to produce muons which will then stop in an aluminum target. Mu2e will search for the $\mu^- + Al \rightarrow e^- + Al$ process. For Mu2e, an extinction rate of 10$^{-10}$ is required to reduce the backgrounds to an acceptable level. Extinction is the ratio of the amount of protons striking the production target between beam pulses to the number striking it during the beam pulse. One of the backgrounds, off-target interactions, was simulated using G4beamline and Fermilab's Grid setup to confirm that an extinction rate of 10$^{-10}$ is possible. The extinction level will be measured by the extinction monitor which will include scintillation counters read out by photomultiplier tubes. In order to build a beam time profile, low fake responses (after pulses) are needed in the photomultiplier tubes. This thesis determines the best combination of resistors, voltage, and other components that provide the lowest after pulse rate.

43 PARTICLE ACCELERATORS↗

Depleted Uranium Discrimination Using Spectral Ratios from Data-Starved Spectra - 18619

The Institute for Clean Energy Technology (ICET) has developed mobile surveying platforms for the retrieval of fired depleted uranium (DU) munitions. ICET surveying platforms are fitted with differential global positioning system (GPS), scintillation detectors, and central processing units (CPUs). The surveying technology has historically been used to assist facilities where DU contamination is a concern to locate, retrieve, and remediate DU-contaminated areas. Residence times over DU sources for mobile systems normally do not produce enough data to use gamma ray spectroscopy to verify the source type. Discussed is a potential method used to discriminate DU signatures in data-starved gamma ray spectral data collected during field surveys. Laboratory tests have shown that data-starved gamma ray spectra for zero-valence, oxide, and uranium ores can be distinguished from each other and from background by spectral ratioing. Zero-valence DU and DU oxide gamma ray signatures differ due to the attenuation of low-energy gammas emitted from U-238 daughters. DU signatures can be differentiated from naturally occurring uranium spectra due to the presence of daughters below U-234, primarily bismuth (Bi)-214, in the uranium decay series. Three primary regions of interest (ROI) within the analyzed test spectra are used to roughly characterize the shape of each test spectrum and compare them to background. The three ROIs are focused around the gamma-emitting daughters of U-238: thorium (Th)-234, protactinium (Pa)-234 metastable (m), and Bi-214. One of the three regions is considered the base region. This region is used to estimate what the counts in the other two regions should be by multiplying the counts in the ROIs by a ratio of background counts from an area previously found to be impacted. Using this spectral ratioing technique, a non-zero difference in spectral ratio values indicates a shift in the test spectra away from background. Calculating ratios between the base region and the other two regions allows for a graphical representation of the data in a two-dimensional spectral ratioing space, which is used to differentiate between the types of uranium sources previously mentioned. Surveying processes that are based on gross counts from scintillation counters can result in a large number of false positives as a result of shifting background signals or the presence of naturally occurring uranium. Application of the spectral ratioing technique can further assist in site characterization by analyzing all of the data-starved survey spectra to identify false positives or the need for additional data collection. Accurate surveys of DU testing and training ranges reduces the costs associated with range clean-up by discriminating clean areas from those requiring remediation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236{+-}0.677 kBq/L and 1.704{+-}0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samples were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO{sub 4} addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 {mu}Sv/year and 0.532 {mu}Sv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 {mu}Sv/year.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electroluminescence TPCs at the thermal diffusion limit

Here, the NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the ${}^{136}$Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/$\sqrt{\mathrm{m}}$ for pure xenon down to 2.5 mm/$\sqrt{\mathrm{m}}$ using additive concentrations of about 0.05%, 0.2% and 0.02% for CO${}_{2}$, CH${}_{4}$ and CF${}_{4}$, respectively. Our results show that CF${}_{4}$ admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH${}_{4}$ presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO${}_{2}$ and CH${}_{4}$ show potential as molecular additives in a large xenon TPC, CH${}_{4}$ showing the best performance and stability to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of cosmic ray techniques

It is pointed out that most advances of cosmic-ray physics have been directly related to the development of observational techniques. A review is presented of the history of the evolution of the techniques and equipment for the study of cosmic-ray physics, taking into account the new scientific advances accompanying each new development related to experimental technology. All of the early observations were performed by means of ionization chambers. These chambers had already been in use for a number of years, when they were first applied to the study of cosmic rays in the early years of this century. However, an application to the low-intensity cosmic radiation required special refinements. Attention is given to the design of suitable electrometers, the development of self-recording instruments, the 'tube counter', the development of the coincidence method, a cosmic-ray 'telescope', a magnetic lens for cosmic rays, an arrangement of Geiger-Mueller counters for the demonstration of secondary radiation, cloud chambers, scintillation counters, and air shower experiments.

Rossi, B.↗

Proportional counter for X-ray analysis of lunar and planetary surfaces

A position sensitive proportional scintillation detector was developed and evaluated for use in applications involving X-ray imaging as well as spectroscopy. Topics covered include limitations of the proportional scintillation counter for use in space; purification of the xenon gas in the detector, and the operation of the detector system. Results show that the light signal in a proportional scintillation detector remains well localized. With modest electric fields in xenon, the primary electrons from a photoelectric absorption of an X-ray can be brought a distance of a few millimeters to a higher field region without spreading more than a millimeter or so. Therefore, it is possible to make a proportional scintillation detector with good position sensitivity that could be used to calibrate out the difference in light collection over its sensitive volume.

Source record↗

A Combined Neutron and Gamma-Ray Multiplicity Counter Based on Liquid Scintillation Detectors

Multiplicity counters for neutron assay have been extensively used in materials control and accountability for nonproliferation and nuclear safeguards. Typically, neutron coincidence counters are utilized in these fields. In this work, we present a measurement system that makes use not only of neutron (n) multiplicity counting but also of gamma-ray (g) multiplicity counting and the combined higher-order multiples containing both neutrons and gamma rays. The benefit of this approach is in using both particle types available from the sample, leading to a reduction in measurement times needed when using more measurables. We present measurement results of n, g, nn, ng, gg, nnn, nng, ngg, and ggg multiples emitted by Mixed-Oxide (MOX) samples measured at Idaho National Laboratory (INL). The MOX measurement is compared to initial validation of the detection system done using a 252Cf source. The dual radiation measuring system proposed here uses extra measurables to improve the statistics when compared to a neutron-only system and allows for extended analysis and interpretation of sample parameters. New challenges such as the effect of very high intrinsic gamma-ray sources in the case of MOX samples is discussed. Successful measurements of multiples rates can be performed also when using high-Z shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal and nonthermal X-ray bursts observed from OSO-7

The UCSD solar X-ray experiment on the OSO-7 observes X-rays in the 2 to 15 keV range with a proportional counter and in the 10.6 to 300 keV range with a scintillation counter. The dynamic range and instrument parameters are chosen to separate X-ray emission due to a hot thermal plasma from that due to nonthermal electron populations for a large number of X-ray events associated with small flares. Many different morphological classes have been observed in the 200 or so principal events observed between October 1971 and June 1972. For events which have both a thermal and nonthermal component, we can perform an analysis which shows that in not all events is it possible for the nonthermal electrons to energize the thermal plasma. We observe many events which have no nonthermal component, at least one event which was purely power law on initiation, and several events which had a long, slow decay of the hard X-rays.

Peterson, L. E.↗

Recent results from the OPERA experiment

OPERA is a long-baseline neutrino oscillation experiment whose main goal is to detect for the first time neutrino oscillations in an appearance mode. Using an almost pure v{sub {mu}} beam we search for a v{sub {mu}}{r_reversible}v{sub {tau}}, transition detecting in a direct way the {tau} lepton. The detector is located on the high-energy, long-baseline CERN to LNGS beam (CNGS) at a baseline of 730 km. The apparatus consists of a target made of lead/emulsion-films bricks and of electronic detectors which are used to tag the neutrino interaction. Experiment description and results from the short but fruitful 2007 CNGS run are reported in details.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Very Short Bursts with the AGILE Mini-Calorimeter

In this paper the results of the first months of burst search on very short time scales with the Mini-Calorimeter (MCAL) on-board the AGILE mission are presented. MCAL is equipped with a flexible on-board trigger logic for autonomous GRB detection. In addition to standard trigger time windows, MCAL has been equipped with trigger capabilities on 16 ms, 1 ms and sub-millisecond time windows. Since June 2008 burst search on these short time scales has been enabled, resulting in an average rate of 4 triggers/orbit, compliant with telemetry budget. An on-ground rejection strategy is applied, allowing more sophisticated selection criteria than those allowed by the on-board trigger logic. Triggers due to instrumental effects or geophysical phenomena can be spotted due to their photon-by-photon pattern; what remains after this cleaning is an almost unexplored territory and could shed light on the origin of very short bursts. The trigger criteria, as well as the on-ground rejection strategy and the properties of the selected events will be described and discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Installation for the search of heavy nonrelativistic particles at sea level

A detector of heavy nonrelativistic sea level particles is described. Selection of events is based on the dependence of the particle path on particle mass at a given speed. Cerenkov counters with beta sub tr = 0.59 are used as speed selectors. Mounted above the detector is a scintillation counter for measuring the ionization caused by a particle. The particle track is recorded by spark chambers.

Galper, A. M.↗

RXTE observations of AGN

The Rossi X-ray Timing Explorer (RXTE) observed three active galaxies during its in-orbit verification phase: NGC 4151; NGC 4945, and MCG 8-11-11. All three were detected from 2 keV to more than 100 keV by a combination of the proportional counter array (PCA) and the high energy X-ray timing experiment (HEXTE). The PCA contains five, xenon/methane, multilayer, multiwire, gas proportional counters covering the 2 to 60 keV range, while HEXTE is an array of eight NaI/CsI phoswich scintillation counters covering the 15 to 250 keV range. The three active galaxies represent the classes of Seyfert 1, Seyfert 2 and intermediate Seyfert galaxies. The results of the fitting of various models containing partial covering fractions, Compton reflection components and high energy spectral breaks are discussed.

Rothschild, R. E.↗

Small angle detectors for study diffractive processes with CMS

The approach and detectors for diffractive physics based on two current projects—Forward Shower Counter (FSC) and Proton Precision Spectrometer (PPS) are presented. FSC system consists of six (3+3) Stations of scintillator counters, which surround closely the beam pipes along 59 m < |z| < 140 m from IP5 on both plus (+) and minus (-) sides. These will detect showers from very forward particles with rapidity 7.5 < |η| < 10 interacting in the beam pipe and surrounding material. FSC allow measurements of single diffraction: p+p → p+G+X (where G is rapidity gap) for lower masses and double diffraction p+p → X+G+X with a large central rapidity gap. The counters can also be used for beam real-time monitoring and will make an invaluable contribution to the understanding of the background environment and its topology. PPS is designed for study the central exclusive production pp → p+X+p, where the + signs denote the absence of hadronic activity (that is, the presence of a rapidity gap) between the outgoing protons and the decay products of the central system X. The precise measurement of the kinematical parameters of the outgoing protons enables to study the properties of the central state X. In PPS part we consider the detector for high precision timing of these protons—QUARTIC. It consists of L-shape bars with quartz or sapphire radiator. The time resolution of the QUARTIC prototypes achieved ≈ 10 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Certain problems in the development and design of scintillation and Cerenkov counters

The feasibility is examined of increasing the effectiveness of the scintillation and Cerenkov counters through improving light collection of the recorded radiation on the photoelectric cathode of the photomultiplier. An example of how to select a detector of the directional plexiglas Cerenkov counter is given. Also presented are experimentally obtained amplitude distributions during the recording of cosmic ray muons. The necessity to obtain agreement between the characteristic spectrum of the photocathode of the photomultiplier and the spectrum of the recorded radiation is stressed.

Chukin, V. S.↗