Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Means for Positioning and Repositioning Scanning Instruments

A method is presented for positioning a scanning instrument to point toward the center of the desired scan wherein the scan is achieved by rotating unbalanced masses (RUMs) rotating about fixed axes of rotation relative to and associated with the instrument, the RUMs being supported on drive shafts spaced from the center of the mass of the instrument and rotating 180 degrees out-of-phase with each other and in planes parallel to each other to achieve the scan. The elevation and cross-elevation angles of the instrument are sensed to determine any offset and offset time rate-of-change, and the magnitude and direction are converted to a RUM cycle angular velocity component to be superimposed on the nominal velocity of the RUMs. This RUM angular velocity component modulates the RUM angular velocity to cause the speed of the RUMs to increase and decrease during each revolution to drive the instrument toward the desired center of the scan.

Polites, Michael E.↗

A Boundary Scan Test Vehicle for Direct Chip Attach Testing

To facilitate the new faster, better and cheaper spacecraft designs, smaller more mass efficient avionics and instruments are using higher density electronic packaging technologies such as direct chip attach (DCA). For space flight applications, these technologies need to have demonstrated reliability and reasonably well defined fabrication and assembly processes before they will be accepted as baseline designs in new missions. As electronics shrink in size, not only can repair be more difficult, but 49 probing" circuitry can be very risky and it becomes increasingly more difficult to identify the specific source of a problem. To test and monitor these new technologies, the Direct Chip Attach Task, under NASA's Electronic Parts and Packaging Program (NEPP), chose the test methodology of boundary scan testing. The boundary scan methodology was developed for interconnect integrity and functional testing at hard to access electrical nodes. With boundary scan testing, active devices are used and failures can be identified to the specific device and lead. This technology permits the incorporation of "built in test" into almost any circuit and thus gives detailed test access to the highly integrated electronic assemblies. This presentation will describe boundary scan, discuss the development of the boundary scan test vehicle for DCA and current plans for testing of direct chip attach configurations.

Parsons, Heather A.↗

PSIDD3: Post-Scan Ultrasonic Data Display System for the Windows-Based PC Including Fuzzy Logic Analysis

Post-Scan Interactive Data Display (PSIDD) III is a user-oriented Windows-based system that facilitates the display and comparison of ultrasonic contact data. The system is optimized to compare ultrasonic measurements made at different locations within a material or at different stages of material degradation. PSIDD III provides complete analysis of the primary wave forms in the time and frequency domains along with the calculation of several frequency dependent properties including Phase Velocity and Attenuation Coefficient and several frequency independent properties, like the Cross Correlation Velocity. The system allows image generation on all of the frequency dependent properties at any available frequency (limited by the bandwidth used in the scans) and on any of the frequency independent properties. From ultrasonic contact scans, areas of interest on an image can be studied with regard to underlying raw waveforms and derived ultrasonic properties by simply selecting the point on the image. The system offers various modes of in-depth comparison between scan points. Up to five scan points can be selected for comparative analysis at once. The system was developed with Borland Delphi software (Visual Pascal) and is based on a SQL database. It is ideal for classification of material properties, or location of microstructure variations in materials.

Lovelace, Jeffrey J.↗

On Utilization of NEXRAD Scan Strategy Information to Infer Discrepancies Associated With Radar and Rain Gauge Surface Volumetric Rainfall Accumulations

To evaluate the Tropical Rainfall Measuring Mission (TRMM) monthly Ground Validation (GV) rain map, 42 quality controlled tipping bucket rain gauge data (1 minute interpolated rain rates) were utilized. We have compared the gauge data to the surface volumetric rainfall accumulation of NEXRAD reflectivity field, (converting to rain rates using a 0.5 dB resolution smooth Z-R table). The comparison was carried out from data collected at Melbourne, Florida during the month of July 98. GV operational level 3 (L3 monthly) accumulation algorithm was used to obtain surface volumetric accumulations for the radar. The gauge records were accumulated using the 1 minute interpolated rain rates while the radar Volume Scan (VOS) intervals remain less than or equal to 75 minutes. The correlation coefficient for the radar and gauge totals for the monthly time-scale remain at 0.93, however, a large difference was noted between the gauge and radar derived rain accumulation when the radar data interval is either 9 minute, or 10 minute. This difference in radar and gauge accumulation is being explained in terms of the radar scan strategy information. The discrepancy in terms of the Volume Coverage Pattern (VCP) of the NEXRAD is being reported where VCP mode is ascertained using the radar tilt angle information. Hourly radar and gauge accumulations have been computed using the present operational L3 method supplemented with a threshold period of +/- 5 minutes (based on a sensitivity analysis). These radar and gauge accumulations are subsequently improved using a radar hourly scan weighting factor (taking ratio of the radar scan frequency within a time bin to the 7436 total radar scans for the month). This GV procedure is further being improved by introducing a spatial smoothing method to yield reasonable bulk radar to gauge ratio for the hourly and daily scales.

Roy, Biswadev↗

Microstructural and Defect Characterization in Ceramic Composites Using an Ultrasonic Guided Wave Scan System

In this study, an ultrasonic guided wave scan system was used to characterize various microstructural and flaw conditions in two types of ceramic matrix composites, SiC/SiC and C/SiC. Rather than attempting to isolate specific lamb wave modes to use for characterization (as is desired for many types of guided wave inspection problems), the guided wave scan system utilizes the total (multi-mode) ultrasonic response in its inspection analysis. Several time and frequency-domain parameters are calculated from the ultrasonic guided wave signal at each scan location to form images. Microstructural and defect conditions examined include delamination, density variation, cracking, and pre/ post-infiltration. Results are compared with thermographic imaging methods. Although the guided wave technique is commonly used so scanning can be eliminated, applying the technique in the scanning mode allows a more precise characterization of defect conditions.

Roth, D. J.↗

Millimeter Wave Synthetic Aperture Imaging System with a Unique Rotary Scanning System

In recent years, millimeter wave imaging techniques, using synthetic aperture focusing and holographical approaches, have shown tremendous potential for nondestructive testing applications, involving materials and structures used in space vehicles, including the space shuttle external fuel tank spray on foam insulation and its acreage heat tiles. The ability of signals at millimeter wave frequencies (30 - 300 GHz) to easily penetrate inside of low loss dielectric materials, their relatively small wavelengths, and the possibility of detecting coherent (magnitude and phase) reflections make them suitable for high resolution synthetic aperture focused imaging the interior of such materials and structures. To accommodate imaging requirements, commonly a scanning system is employed that provides for a raster scan of the desired structure. However, most such scanners, although simple in design and construction, are inherently slow primarily due to the need to stop and start at the beginning and end of each scan line. To this end, a millimeter wave synthetic aperture focusing system including a custom-designed transceiver operating at 35 - 45 GHz (Q-band) and unique and complex rotary scanner was designed and developed. The rotary scanner is capable of scanning an area with approximately 80 cm in diameter in less than 10 minutes at step sizes of 3 mm and smaller. The transceiver is capable of producing accurate magnitude and phase of reflected signal from the structure under test. Finally, a synthetic aperture focusing algorithm was developed that translates this rotary-obtained magnitude and phase into a synthetic aperture focusing image of inspected structures. This paper presents the design of the transceiver and the rotary scanning system along with showing several images obtained with this system from various complicated structures.

Ghasr, M. T.↗

High-Resolution, Wide-Field-of-View Scanning Telescope

A proposed telescope would afford high resolution over a narrow field of view (<0.10 ) while scanning over a total field of view nominally 16 wide without need to slew the entire massive telescope structure. The telescope design enables resolution of a 1-m-wide object in a 50- km-wide area of the surface of the Earth as part of a 200-km-wide area field of view monitored from an orbit at an altitude of 700 km. The conceptual design of this telescope could also be adapted to other applications both terrestrial and extraterrestrial in which there are requirements for telescopes that afford both wide- and narrow-field capabilities. In the proposed telescope, the scanning would be effected according to a principle similar to that of the Arecibo radio telescope, in which the primary mirror is stationary with respect to the ground and a receiver is moved across the focal surface of the primary mirror. The proposed telescope would comprise (1) a large spherical primary mirror that would afford high resolution over a narrow field of view and (2) a small displaceable optical relay segment that would be pivoted about the center of an aperture stop to effect the required scanning (see figure). Taken together, both comprise a scanning narrow-angle telescope that does not require slewing the telescope structure. In normal operation, the massive telescope structure would stare at a fixed location on the ground. The inner moveable relay optic would be pivoted to scan the narrower field of view over the wider one, making it possible to retain a fixed telescope orientation, while obtaining high-resolution images over multiple target areas during an interval of 3 to 4 minutes in the intended orbit. The pivoting relay segment of the narrow-angle telescope would include refractive and reflective optical elements, including two aspherical mirrors, to counteract the spherical aberration of the primary mirror. Overall, the combination of the primary mirror and the smaller relay optic would provide narrow-angle, diffraction-limited high resolution at a wavelength of 500 nm.

Sepulveda, Cesar↗

Space Communications and Navigation (SCaN) Integrated Network Architecture Definition Document (ADD): Executive Summary - Volume 1

The SCaN Program has defined an integrated network architecture that fully meets the Administrator s mandate to the Program, and will result in a NASA infrastructure capable of providing the needed and enabling communications services to future space missions. The integrated network architecture will increase SCaN operational efficiency and interoperability through standardization, commonality and technology infusion. It will enable NASA missions requiring advanced communication and tracking capabilities such as: a. Optical communication b. Antenna arraying c. Lunar and Mars Relays d. Integrated network management (service management and network control) and integrated service execution e. Enhanced tracking for navigation f. Space internetworking with DTN and IP g. End-to-end security h. Enhanced security services Moreover, the SCaN Program has created an Integrated Network Roadmap that depicts an orchestrated and coherent evolution path toward the target architecture, encompassing all aspects that concern network assets (i.e., operations and maintenance, sustaining engineering, upgrade efforts, and major development). This roadmap identifies major NASA ADPs, and shows dependencies and drivers among the various planned undertakings and timelines. The roadmap is scalable to accommodate timely adjustments in response to Agency needs, goals, objectives and funding. Future challenges to implementing this architecture include balancing user mission needs, technology development, and the availability of funding within NASA s priorities. Strategies for addressing these challenges are to: define a flexible architecture, update the architecture periodically, use ADPs to evaluate options and determine when to make decisions, and to engage the stakeholders in these evaluations. In addition, the SCaN Program will evaluate and respond to mission need dates for technical and operational capabilities to be provided by the SCaN integrated network. In that regard, the architecture defined in this ADD is scalable to accommodate programmatic and technical changes.

Younes, Badri A.↗

Thermal Stability of a 4 Meter Primary Reflector for the Scanning Microwave Limb Sounder

We describe the fabrication and thermal-stability analysis and test of a composite demonstration model of the Scanning Microwave Limb Sounder (SMLS) primary reflector, having full 4m height and 1/3 the width planned for flight. SMLS is a space-borne heterodyne radiometer which will measure pressure, temperature and atmospheric constituents from thermal emission between 180 and 660 GHz. Current MLS instruments in low Earth orbit scan pencil-beam antennas (sized to resolve about one scale height) vertically over the atmospheric limb. SMLS, planned for the Global Atmospheric Composition Mission of the NRC Decadal Survey, adds azimuthal scanning for better horizontal and temporal resolution and coverage than typical orbit spacing provides. SMLS combines the wide scan range of the parabolic torus with unblocked offset Cassegrain optics. The resulting system is diffraction-limited in the vertical plane but highly astigmatic in the horizontal, having a beam aspect ratio [tilde operator]1:20. Symmetry about the nadir axis ensures that beam shape is nearly invariant over +/-65(white bullet) azimuth. The a feeds a low-noise SIS receiver whose FOV is swept over the reflector system by a small scanning mirror. Using finiteelement models of antenna reflectors and structure, we evaluate thermal deformations and the resulting optical performance for 4 orbital environments and isothermal soak. We compare deformations with photogrammetric measurements made during wide-range (ambient+[-97,+75](white bullet) C) thermal soak tests of the primary in a chamber. This range exceeds predicted orbital soak ranges by large factors, implying in-orbit thermal stability of 0.21(mu)m rms/(white bullet)C, which meets SMLS requirements.

Thermal stability tests↗

A Cross-Track Cloud-Scanning Dual-Frequency Doppler (C2D2) Radar for the Proposed ACE Mission and Beyond

The National Resource Council’s Earth Science Decadal Survey” (NRCDS) has identified the Aerosol/Climate/Ecosystems (ACE) Mission as a priority mission for NASA Earth science. The NRC recommended the inclusion of "a cross-track scanning cloud radar with channels at 94 GHz and possibly 34 GHz for measurement of cloud droplet size, glaciation height, and cloud height". Several radar concepts have been proposed that meet some of the requirements of the proposed ACE mission but none have provided scanning capability at both 34 and 94 GHz due to the challenge of constructing scanning antennas at 94 GHz. In this paper, we will describe a radar design that leverages new developments in microwave monolithic integrated circuits (MMICs) and micro-machining to enable an electronically-scanned radar with both Ka-band (35 GHz) and W-band (94-GHz) channels. This system uses a dual-frequency linear active electronically-steered array (AESA) combined with a parabolic cylindrical reflector. This configuration provides a large aperture (3m x 5m) with electronic-steering but is much simpler than a two-dimension AESA of similar size. Still, the W-band frequency requires element spacing of approximately 2.5 mm, presenting significant challenges for signal routing and incorporation of MMICs. By combining (Gallium Nitride) GaN MMIC technology with micro-machined radiators and interconnects and silicon-germanium (SiGe) beamforming MMICs, we are able to meet all the performance and packaging requirements of the linear array feed and enable simultaneous scanning of Ka-band and W-band radars over swath of up to 100 km.

Aerosol/Climate/Ecosystems (ACE) Mission↗

Space Communications and Navigation (SCaN) Network Simulation Tool Development and Its Use Cases

In this work, we focus on the development of a simulation tool to assist in analysis of current and future (proposed) network architectures for NASA. Specifically, the Space Communications and Navigation (SCaN) Network is being architected as an integrated set of new assets and a federation of upgraded legacy systems. The SCaN architecture for the initial missions for returning humans to the moon and beyond will include the Space Network (SN) and the Near-Earth Network (NEN). In addition to SCaN, the initial mission scenario involves a Crew Exploration Vehicle (CEV), the International Space Station (ISS) and NASA Integrated Services Network (NISN). We call the tool being developed the SCaN Network Integration and Engineering (SCaN NI&E) Simulator. The intended uses of such a simulator are: (1) to characterize performance of particular protocols and configurations in mission planning phases; (2) to optimize system configurations by testing a larger parameter space than may be feasible in either production networks or an emulated environment; (3) to test solutions in order to find issues/risks before committing more significant resources needed to produce real hardware or flight software systems. We describe two use cases of the tool: (1) standalone simulation of CEV to ISS baseline scenario to determine network performance, (2) participation in Distributed Simulation Integration Laboratory (DSIL) tests to perform function testing and verify interface and interoperability of geographically dispersed simulations/emulations.

Jennings, Esther↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earth's surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Response Versus Scan-Angle Corrections for MODIS Reflective Solar Bands Using Deep Convective Clouds

The absolute radiometric calibration of the reflective solar bands (RSBs) of Aqua- and Terra-MODIS is performed using on-board calibrators. A solar diffuser (SD) panel along with a solar diffuser stability monitor (SDSM) system, which tracks the performance of the SD over time, provides the absolute reference for calibrating the MODIS sensors. MODIS also views the moon and deep space through its space view (SV) port for lunar-based calibration and computing the zero input radiance, respectively. The MODIS instrument views the Earths surface through a two-sided scan mirror, whose reflectance is a function of angle of incidence (AOI) and is described by response versus scan-angle (RVS). The RVS for both MODIS instruments was characterized prior to launch. MODIS also views the SD and the moon at two different assigned RVS positions. There is sufficient evidence that the RVS is changing on orbit over time and as a function of wavelength. The SD and lunar observation scans can only track the RVS variation at two RVS positions. Consequently, the MODIS Characterization Support Team (MCST) developed enhanced approaches that supplement the onboard calibrator measurements with responses from pseudo-invariant desert sites. This approach has been implemented in Level 1B (L1B) Collection 6 (C6) for selected short-wavelength bands. This paper presents an alternative approach of characterizing the mirror RVS to derive the time-dependent RVS correction factors for MODIS RSBs using tropical deep convective cloud (DCC) targets. An initial assessment of the DCC response from Aqua-MODIS band 1 C6 data indicates evidence of RVS artifacts, which are not uniform across the scans and are more prevalent in the left side Earth-view scans.

Bhatt, Rajendra↗

Postlaunch Assessment of the Response Versus Scan Angle for the Thermal Emissive Bands of Visible Infrared Imaging Radiometer Suite On-Board the Suomi National Polar-Orbiting Partnership Satellite

The visible infrared imaging radiometer suite (VIIRS) is a key sensor carried on the Suomi national polar-orbiting partnership (S-NPP) satellite, which was launched in October 2011. It has several on-board calibration components, including a solar diffuser and a solar diffuser stability monitor for the reflective solar bands, a V-groove blackbody for the thermal emissive bands (TEB), and a space view port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle. Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first 3 months of intensive Cal/Val. The S-NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of Earth view scan angles, which can be used to characterize the TEB RVS. This study provides our analysis of the pitch maneuver data and assessment of the derived TEB RVS by comparison with prelaunch results. In addition, the stability of the RVS after the first 5 years of operation is examined using observed brightness temperatures (BT) over a clear ocean at various angles of incidence (AOI). To reduce the impact of variations in the BT measurements, the daily overpasses collected over the ocean are screened for cloud contamination, normalized to the results obtained at the blackbody AOI, and averaged each year.

Wu, Aisheng↗

Analysis of the on-orbit Response-Versus-Scan-angle for the MODIS SWIR Bands Derived from Lunar Observations

The Moderate Resolution Imaging Spectroradiometer (MODIS) on board the Terra and Aqua platforms is a multi-spectral, whiskbroom scanning radiometer with 36 spectral bands covering wavelengths from 0:4 - 14:2 μm. Among these bands, the 20 reflective solar bands (RSB, 0:4 - 2:1 μm) use an on-board solar difuser (SD) and SD stability monitor (SDSM) to track the detector gain changes on orbit. In addition to this, lunar and Earth-view (EV) observations are used in order to characterize the scan-mirror response versus scan angle (RVS), which improves the Earth-view retrieval over the full width of each scan. For the short-wave infrared bands (SWIR, 1:2 - 2:1 μm), the prelaunch RVS has been used for both Aqua and Terra MODIS throughout each mission. While these bands are not expected to have a significant change in the RVS on-orbit, issues such as electronic crosstalk and an out-of-band optical leak have prevented the use of the Moon for deriving the on-orbit RVS for validation. However, recent improvements to the MODIS lunar calibration for the SWIR bands allow us to mitigate the electronic crosstalk impact and derive the RVS for the SWIR bands. In this work, we will assess the impact of this newly derived RVS on the EV data compared to MODIS Collection 6.1. By comparing to EV data obtained from pseudo-invariant calibration sites at different angles-of-incidence on the scan mirror, we can assess the effectiveness of the newly derived RVS from the Moon. We find that while the change in the RVS on-orbit for the SWIR bands is relatively small, applying a correction to the RVS based on the Moon and SD data can provide an improvement for some bands.

MODIS↗

Advanced Libya-4 radiometric and atmospheric characterization utilizing MODIS and VIIRS full-scan reflective solar band measurements

The NASA Clouds and the Earth's Radiant Energy System (CERES) project provides observed flux and cloud products to the climate science community. The CERES instruments, along with the MODIS and VIIRS imagers, are onboard the Terra, Aqua, NPP, and NOAA20 satellites. In order to produce seamless multi-platform integrated products, long-term sensor stability and inter-calibration are required. Inter-calibration between sensors within the same sun-synchronous orbit relies on Earth invariant targets because simultaneous nadir overpasses are not possible. To facilitate inter-calibration efforts, the CERES Imager and Geostationary Calibration Group (IGCG) has improved the Libya-4 target characterization. Improvements include full scan angle characterization to enable daily observations, clear-sky identification using individual scan angle dynamic spatial homogeneity thresholds, and atmospheric corrections. The water vapor correction was found to be effective across the full scan, whereas the ozone and aerosol corrections were less effective. The atmospheric-corrected normalized radiance temporal fluctuations are similar across scan angles, spectral bands, and between the MODIS and VIIRS imagers, suggesting that the fluctuations are a result of the natural variability of the Libya-4 surface reflectance. The Libya-4 surface variability is more than likely caused by changes in the prevailing winds that alter sand dune orientation and resulting shadows. The full-scan-imager atmosphere and angle corrected reflected solar band radiance trend standard errors are between 0.6% and 1.0%, and for near-nadir observations, are between 0.5% and 0.8%. The advanced characterization suggests that the Libya-4 short-term surface reflectance anomalies may need to be considered for imager stability monitoring and inter-calibration efforts.

Libya-4 Pseudo-invariant Calibration Site↗

A Deployable 4 Meter 180 to 680 GHz Antenna for the Scanning Microwave Limb Sounder

The Scanning Microwave Limb Sounder (SMLS) is a space-borne heterodyne radiometer which will measure pressure, temperature and atmospheric constituents from thermal emission between 180 and 680 GHz. SMLS, planned for the Global Atmospheric Composition Mission of the NRC Decadal Survey, uses a novel toric Cassegrain antenna to perform both elevation and azimuth scanning. These provide better horizontal and temporal resolution and coverage than were possible with elevation-only scanning at typical Low-Earth orbit spacing in the two previous MLS satellite instruments. Development of the SMLS antenna was the focus of a 2006 Small Business Innovative Research (SBIR) program whose phase II culminated in the fabrication and thermal stability testing of a composite demonstration model of the SMLS primary reflector. This reflector has the full 4m height and 1/3 the width planned for flight. An Instrument Incubator Program (IIP) titled "A deployable 4 Meter 180 to 680 GHz antenna for the Scanning Microwave Limb Sounder" continues development of the SMLS antenna with the study of 5 topics: 1) detailed mathematical modeling of the antenna patterns from which we simulate geophysical parameter retrievals in order to establish FOV performance requirements; 2) thorough correlation of finite element model predictions with measurements made on the SBIR reflector. We will again measure deformations of this reflector, under more flight-like thermal gradients, using higher precision metrology techniques available in a new large-aperture facility at JPL; 3) fabrication of a full-width primary reflector whose asbuilt surface figure will better meet the figure requirements of SMLS than did the SBIR reflector; 4) integration of the primary with other reflectors, and with residual front ends built in a 2007 IIP, in a breadboard antenna; and finally 5) RF testing of the breadboard on a Near Field Range at JPL. We report on significant progress in 3 areas of the current IIP: development of the mathematical model to predict SMLS antenna patterns and their application in a preliminary set of geophysical retrievals; the correlation between surface deformation predicted by finite element models and measurement in the 2009 isothermal stability tests of the SBIR, with implications for the thermal gradient testing to be performed at JPL; and aspects of the conceptual design of the full-width primary reflector to be fabricated and tested in the 2nd and 3rd years of the IIP.

heterodyne radiometer↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗