Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Risk Register”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-F-T-632: On the Use of Intensity Modulated Arc Therapy for Thoracic Vertebral Metastases SBRT Treatment

Purpose: To retrospectively evaluate quality, efficiency and delivery accuracy of intensity modulated arc therapy (IMAT) plans for thoracic-vertebral metastases using stereotactic body radiotherapy (SBRT). Methods: After obtaining approval of RPC-benchmark plan, seven previously treated thoracic-vertebral metastases patients with non-coplanar hybrid arcs(NC-HA)using 1–2 3D-dynamic conformal partial-arcs plus 7–9 IMRT-beams were re-optimized with IMAT using 3 full co-planar arcs. Tumors were located between T2–T7. T1/T2-weighted MRI images were co-registered with planning-CT. PTVs were between 24.3–240.1cc(median=48.1cc). Prescription was 30Gy in 5 fractions with 6-MV beams at Novalis-TX consisting of HD-MLC.Plans were compared for target coverage:conformality index(CI),homogeneity index(HI),PTVD90. Organs-at-risks(OARs)was evaluated for spinal cord(Dmax, D0.35cc, and D1.2cc), esophagus(Dmax and D5cc),heart(Dmax, D15cc)and lung(V5 and V10). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance(QA) plan. Beam-on time was recorded and a gamma index was used to compare agreement between planned and measured doses. Results: SBRT IMAT plans resulted in superior CI(1.02 vs. 1.36, p=0.05) and HI (0.14 vs. 0.27, p=0.01). PTVD90 was improved but statistically insignificant (31.0 vs. 30.4Gy, p=0.38). IMAT resulted in statistically significant improvements in OARs sparing: esophagus max(22.5 vs. 27.0Gy, p=0.03), esophagus 5cc (17.6 vs. 21.5Gy, p=0.02) and heart max(13.1 vs. 15.8Gy, p=0.03). Spinal cord,lung V5 and V10 were lower but statistically insignificant. Average total MU and beam-on time were 2598±354 vs. 3542±495 and 4.7±0.6 min vs. 7.1±1.0min for IMAT vs. NC-HA (without accounting for couch kicks time for NC-HA). IMAT plans demonstrated an accurate dose delivery of 95.5±1.0% for clinical gamma passing-rate of 2%/2mm criteria on MapCHECK, that was comparable to NC-HA plans. Conclusion: IMAT plans provided highly conformal and homogeneous dose distributions to target and reduced OARs doses compared to NC-HA. Total MU was reduced by a factor of 1.4 and subsequently decreased treatment times significantly - potentially minimizing intra-fraction motion error and owing to patient comfort. SBRT using IMAT planning for single fraction thoracic-vertebrae metastases will be investigated.

60 APPLIED LIFE SCIENCES↗

Mars Exploration Rovers Landing Dispersion Analysis

Landing dispersion estimates for the Mars Exploration Rover missions were key elements in the site targeting process and in the evaluation of landing risk. This paper addresses the process and results of the landing dispersion analyses performed for both Spirit and Opportunity. The several contributors to landing dispersions (navigation and atmospheric uncertainties, spacecraft modeling, winds, and margins) are discussed, as are the analysis tools used. JPL's MarsLS program, a MATLAB-based landing dispersion visualization and statistical analysis tool, was used to calculate the probability of landing within hazardous areas. By convolving this with the probability of landing within flight system limits (in-spec landing) for each hazard area, a single overall measure of landing risk was calculated for each landing ellipse. In-spec probability contours were also generated, allowing a more synoptic view of site risks, illustrating the sensitivity to changes in landing location, and quantifying the possible consequences of anomalies such as incomplete maneuvers. Data and products required to support these analyses are described, including the landing footprints calculated by NASA Langley's POST program and JPL's AEPL program, cartographically registered base maps and hazard maps, and flight system estimates of in-spec landing probabilities for each hazard terrain type. Various factors encountered during operations, including evolving navigation estimates and changing atmospheric models, are discussed and final landing points are compared with approach estimates.

Knocke, Philip C.↗

Mars Exploration Rovers landing dispersion analysis

Landing dispersion estimates for the Mars Exploration Rover missions were key elements in the site targeting process and in the evaluation of landing risk. This paper addresses the process and results of the landing dispersion analyses performed for both Spirit and Opportunity. The several contributors to landing dispersions (navigation and atmospheric uncertainties, spacecraft modeling, winds, and margins) are discussed, as are the analysis tools used. The JPL MarsLS program, a MATLAB-based landing dispersion visualization and statistical analysis tool, was used to calculate the probability of landing within hazardous areas. By convolving this with the probability of landing within flight system limits (in-spec landing) for each hazard area, a single overall measure of landing risk was calculated for each landing ellipse. In-spec probability contours were also generated, allowing a more synoptic view of site risks, illustrating the sensitivity to changes in landing location, and quantifying the possible consequences of anomalies such as incomplete maneuvers. Data and products required to support these analyses are described, including the landing footprints calculated by NASA Langley's POST program and the JPL AEPL program, cartographically registered base maps and hazard maps, and flight system estimates of in-spec landing probabilities for each hazard terrain type. Various factors encountered during operations, including evolving navigation estimates and changing atmospheric models, are discussed and final landing points are compared with approach estimates.

Desai, Prasun N.↗

Role of Adaptive Radiotherapy During Concomitant Chemoradiotherapy for Lung Cancer: Analysis of Data From a Prospective Clinical Trial

Purpose: Respiratory-gated radiotherapy allows for the reduction of the toxicity associated with concomitant chemoradiotherapy, but the smaller fields used could increase the risk of missing the target. A prospective study was performed to evaluate the dosimetric consequences of time-trend changes in patients with lung cancer who were treated with concomitant chemoradiotherapy. Methods and Materials: A total of 24 lung cancer patients eligible for chemoradiotherapy and gated delivery underwent four-dimensional computed tomography (4D-CT) after 15 fractions. This scan was co-registered with the initial planning 4D-CT and a new planning target volume (PTV) was generated on the basis of the tumor visualized after 15 fractions. Coverage of the repeat PTV was evaluated by applying the original plan to the second scan and recalculating the dose. Plan modification was triggered by a 5% reduction in the PTV included within the 95% isodose volume or an unacceptable increase in the critical organ dose. Results: Of the 21 evaluable patients, 15 had an average reduction in the PTV of 8% after 30 Gy. The PTV increased in the remaining 6 patients, but the increase was >20% in only 1 patient. In the latter patient, disease progression was observed, and repeat planning was required. The plans created using the new PTV were acceptable in all the other patients. Conclusion: The role of adaptive radiotherapy appears limited when respiratory-gated radiotherapy is used to reduce the toxicity related to concomitant chemoradiotherapy. The use of more conformal treatment techniques might provide the rationale for repeat imaging as a method to identify patients at risk of dosimetric miss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis

Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SV determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-80: A Comparative Analysis of MIM and Pinnacle Software for Adaptive Planning

Purpose: IMRT treatment is often administered with image guidance and small PTV margins. Change in body habitus such as weight loss and tumor response during the course of a treatment could be significant, thus warranting re-simulation and re-planning. Adaptive planning is challenging and places significant burden on the staff, as such some commercial vendors are now offering adaptive planning software to stream line the process of re-planning and dose accumulation between different CT data set. The purpose of this abstract is to compare the adaptive planning tools between Pinnacle version 9.8 and MIM 6.4 software. Methods: Head and Neck cases of previously treated patients that experienced anatomical changes during the course of their treatment were chosen for evaluation. The new CT data set from the re-simulation was imported to Pinnacle and MIM software. The dynamic planning tool in pinnacle was used to calculate the old plan with fixed MU setting on the new CT data. In MIM, the old CT was registered to the new data set, followed by a dose transformation to the new CT. The dose distribution to the PTV and critical structures from each software were analyzed and compared. Results: 9% difference was observed between the Global maximum doses reported by both software. Mean doses to organs at risk and PTV’s were within 6 % however pinnacle showed greater difference in PTV coverage change. Conclusion: MIM software adaptive planning corrects for geometrical changes without consideration for the effect of radiological path length on dose distribution; however Pinnacle corrects for both geometric and radiological effect on the dose distribution. Pinnacle gives a better estimate of the dosimetric impact due to anatomical changes.

60 APPLIED LIFE SCIENCES↗

Assessment of the Impacts of ACLS on the ISS Life Support System using Dynamic Simulations in V-HAB

The Advanced Closed Loop System (ACLS) is currently under development by Airbus Defense and Space and is slated for launch to the International Space Station (ISS) in 2017. The addition of new hardware into an already complex system such as the ISS life support system (LSS) always poses operational risks. It is therefore important to understand the impacts ACLS will have on the existing systems to ensure smooth operations for the ISS. This analysis can be done by using dynamic computer simulations and one possible tool for such a simulation is Virtual Habitat (V-HAB). Based on Matlab (Registered Trademark) V-HAB has been under development at the Institute of Astronautics of the Technical University Munich (TUM) since 2006 and in the past has been successfully used to simulate the ISS life support systems. The existing V-HAB ISS simulation model treated the interior volume of the space station as one large ideally-stirred container. This model was improved to allow the calculation of the atmospheric composition inside the individual modules of the ISS by splitting it into ten distinct volumes. The virtual volumes are connected by a simulation of the inter-module ventilation flows. This allows for a combined simulation of the LSS hardware and the atmospheric composition aboard the ISS. A dynamic model of ACLS is added to the ISS simulation and different operating modes for both ACLS and the existing ISS life support systems are studied to determine the impacts of ACLS on the rest of the system. The results suggest that the US, Russian and ACLS CO2 systems can operate at the same time without impeding each other. Furthermore, based on the results of this analysis, the US and ACLS Sabatier systems can be operated in parallel as well to achieve the highest possible CO2 recycling together with a low CO2 concentration.

Puetz, Daniel↗

TU-AB-303-06: Does Online Adaptive Radiation Therapy Mean Zero Margin for Intermediate-Risk Prostate Cancer? An Intra-Fractional Seminal Vesicles Motion Analysis

Purpose: To provide benchmark for seminal vesicles (SVs) margin selection to account for intra-fractional motion; and to investigate the effectiveness of two motion surrogates in predicting intra-fractional SV underdosage. Methods: 9 prostate SBRT patients were studied; each has five pairs of pre-treatment and post-treatment cone-beam CTs (CBCTs). Each pair of CBCTs was registered based on fiducial markers in the prostate. To provide “ground truth” for coverage evaluation, all pre-treatment SVs were expanded with isotropic margin of 1,2,3,5 and 8mm, and their overlap with post-treatment SVs were used to quantify intra-fractional coverage. Two commonly used motion surrogates, the center-of-mass (COM) and the border of contour (the most distal points in SI/AP/LR directions) were evaluated using Receiver-Operating Characteristic (ROC) analyses for predicting SV underdosage due to intra-fractional motion. Action threshold of determining underdosage for each surrogate was calculated by selecting the optimal balancing between sensitivity and specificity. For comparison, margin for each surrogate was also calculated based on traditional margin recipe. Results: 90% post-treatment SV coverage can be achieved in 47%, 82%, 91%, 98% and 98% fractions for 1,2,3,5 and 8mm margins. 3mm margin ensured the 90% intra-fractional SV coverage in 90% fractions when prostate was aligned. The ROC analysis indicated the AUC for COM and border were 0.88 and 0.72. The underdosage threshold was 2.9mm for COM and 4.1mm for border. The Van Herk’s margin recipe recommended 0.5, 0 and 1.8mm margin in LR, AP and SI direction based on COM and for border, the corresponding margin was 2.1, 4.5 and 3mm. Conclusion: 3mm isotropic margin is the minimum required to mitigate the intra-fractional SV motion when prostate is aligned. ROC analysis reveals that both COM and border are acceptable predictors for SV underdosage with 2.9mm and 4.1mm action threshold. Traditional margin calculation is less reliable for this application. This work is partially supported a master research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Radioiodine Biogeochemistry and Prevalence in Groundwater

129I is commonly either the top or among the top risk drivers, along with 99Tc, at radiological waste disposal sites and contaminated groundwater sites where nuclear material fabrication or reprocessing has occurred. The risk stems largely from 129I having a high toxicity, a high bioaccumulation factor (90% of all the body’s iodine concentrates in the thyroid), a high inventory at source terms (due to its high fission yield), an extremely long half-life (16M yr), and rapid mobility in the subsurface environment. Another important reason that 129I is a key risk driver is that there is the uncertainty regarding its biogeochemical fate and transport in the environment. We typically can define 129I mass balance and flux at sites, but cannot predict accurately its response to changes in the environment. As a consequence of some of these characteristics, 129I has a very low Drinking Water Standard, DWS, which is set at 1 pCi/L, the lowest of all radionuclides in the Federal Register. Recently, significant advancements have been made in detecting iodine species at ambient groundwater concentrations, defining the nature of the organic matter and iodine bond, and quantifying the role of naturally occurring sediment microbes to promote iodine oxidation and reduction. These recent studies have led to a more mechanistic understanding of radioiodine biogeochemistry. The objective of this review is to describe these advances and to provide a state of the science of radioiodine biogeochemistry relevant to its fate and transport in the terrestrial environment and provide information useful for making decisions regarding the stewardship and remediation of 129I contaminated sites. As part of this review, knowledge gaps were identified that would significantly advance the goals of basic and applied research programs for accelerating 129I environmental remediation and reducing uncertainty associated with disposal of 129I waste. Together the information gained from addressing these knowledge gaps will not alter the observation that 129I is primarily mobile, but it will likely permit demonstration that the entire 129I pool in the source term is not moving at the same rate and some may be tightly bound to the sediment, thereby “smearing” the modeled 129I peak and reducing maximum calculated risk.

Kaplan, Daniel I.↗

Image-Guided Radiotherapy for Left-Sided Breast Cancer Patients: Geometrical Uncertainty of the Heart

Purpose: To quantify the geometrical uncertainties for the heart during radiotherapy treatment of left-sided breast cancer patients and to determine and validate planning organ at risk volume (PRV) margins. Methods and Materials: Twenty-two patients treated in supine position in 28 fractions with regularly acquired cone-beam computed tomography (CBCT) scans for offline setup correction were included. Retrospectively, the CBCT scans were reconstructed into 10-phase respiration correlated four-dimensional scans. The heart was registered in each breathing phase to the planning CT scan to establish the respiratory heart motion during the CBCT scan ({sigma}{sub resp}). The average of the respiratory motion was calculated as the heart displacement error for a fraction. Subsequently, the systematic ({Sigma}), random ({sigma}), and total random ({sigma}{sub tot}={radical}({sigma}{sup 2}+{sigma}{sub resp}{sup 2})) errors of the heart position were calculated. Based on the errors a PRV margin for the heart was calculated to ensure that the maximum heart dose (D{sub max}) is not underestimated in at least 90% of the cases (M{sub heart} = 1.3{Sigma}-0.5{sigma}{sub tot}). All analysis were performed in left-right (LR), craniocaudal (CC), and anteroposterior (AP) directions with respect to both online and offline bony anatomy setup corrections. The PRV margin was validated by accumulating the dose to the heart based on the heart registrations and comparing the planned PRV D{sub max} to the accumulated heart D{sub max}. Results: For online setup correction, the cardiac geometrical uncertainties and PRV margins were N-Ary-Summation = 2.2/3.2/2.1 mm, {sigma} = 2.1/2.9/1.4 mm, and M{sub heart} = 1.6/2.3/1.3 mm for LR/CC/AP, respectively. For offline setup correction these were N-Ary-Summation = 2.4/3.7/2.2 mm, {sigma} = 2.9/4.1/2.7 mm, and M{sub heart} = 1.6/2.1/1.4 mm. Cardiac motion induced by breathing was {sigma}{sub resp} = 1.4/2.9/1.4 mm for LR/CC/AP. The PRV D{sub max} underestimated the accumulated heart D{sub max} for 9.1% patients using online and 13.6% patients using offline bony anatomy setup correction, which validated that PRV margin size was adequate. Conclusion: Considerable cardiac position variability relative to the bony anatomy was observed in breast cancer patients. A PRV margin can be used during treatment planning to take these uncertainties into account.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the plutonium hold-up in glove box before dismantling - 15111

The French Bruyeres-Le-Chatel CEA (Commissariat a l'Energie Atomique et aux Energies Alternatives - French Alternatives Energies and Atomic Energy Commission) research center is going through a period of cleaning and dismantling of theses old treatment facilities on fissile materials and others associated nuclides. Some very large glove boxes contained some machines like melting furnace which can't be moved and are dismantled in situ. We need to evaluate the quantity of fissile materials to prevent criticality risk, to bring the evidence to the safety authority, to manage for the best the radioprotection of the workers and to manage waste production. A melting furnace in a glove box was dismantled. Measurements by gamma spectrometry with an HPGe detector (High Purity Germanium) and passive neutron counting (coincidence counting with shift register) are done in situ (furnace in the glove box). In order to refine the measurements, some data acquisitions by sector of glove box were carried out. In view of the geometries to characterize, some modelings have been created, in order to correct the different attenuations and to determine the plutonium masses content in the glove box, including the use of infinite energy technique. For the measurement by passive neutron counting (coincidence counting with shift register), we have used two slabs in high density polythene including nine He3 counters in each slab. This measurement technique is complementary to gamma spectrometry, and allows quantizing the fissile material which would be included in interstice of high Z material. The 100-L and 200-L drums produced during the dismantling were also measured. Based on simplified assumptions to analyze in situ measurements, plutonium weight could be evaluated. This approach of measurement in amount, during and after dismantling, has allowed to quantize the fissile material mass present in the glove box and didn't produce waste package which wouldn't respected the technical specifications of storage outlets. The results show good agreement between in situ and waste measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-11: Radiobiologically Optimized Patient Localization During Prostate External Beam Localization

Purpose: To present a novel positioning strategy which optimizes radiation delivery with radiobiological response knowledge, and to evaluate its application during prostate external beam radiotherapy. Methods: Ten patients with low or intermediate risk prostate cancer were evaluated retrospectively in this IRB-approved study. For each patient, a VMAT plan was generated on the planning CT (PCT) to deliver 78 Gy in 39 fractions with PTV = prostate + 7 mm margin, except for 5mm in the posterior direction. Five representative pretreatment CBCT images were selected for each patient, and prostate, rectum, and bladder were delineated on all CBCT images. Each CBCT was auto-registered to the corresponding PCT. Starting from this auto-matched position (AM-position), a search for optimal treatment position was performed utilizing a score function based on radiobiological and dosimetric indices (D98-DTV, NTCP-rectum, and NTCP-bladder) for the daily target volume (DTV), rectum, and bladder. DTV was defined as prostate + 4 mm margin to account for intra-fraction motion as well as contouring variability on CBCT. We termed the optimal treatment position the radiobiologically optimized couch shift position (ROCS-position). Results: The indices, averaged over the 10 patients’ treatment plans, were (mean±SD): 77.7±0.2 Gy (D98-PTV), 12.3±2.7% (NTCP-rectum), and 53.2±11.2% (NTCP-bladder). The corresponding values calculated on all 50 CBCT images at the AM-positions were 72.9±11.3 Gy (D98-DTV), 15.8±6.4% (NTCP-rectum), and 53.0±21.1% (NTCP-bladder), respectively. In comparison, calculated on CBCT at the ROCS-positions, the indices were 77.0±2.1 Gy (D98-DTV), 12.1±5.7% (NTCP-rectum), and 60.7±16.4% (NTCP-bladder). Compared to autoregistration, ROCS-optimization recovered dose coverage to target volume and lowered the risk to rectum. Moreover, NTCPrectum for one patient remained high after ROCS-optimization and therefore could potentially benefit from adaptive planning. Conclusion: These encouraging results illustrate the potential utility of applying radiobiologically optimized correction for online image-guided radiotherapy of prostate patients.

60 APPLIED LIFE SCIENCES↗

Prospective Study of Alternating Chemoradiotherapy Consisting of Extended-Field Dynamic Conformational Radiotherapy and Systemic Chemotherapy Using 5-FU and Nedaplatin for Patients in High-Risk Group With Cervical Carcinoma

Purpose: To assess the efficacy of alternating chemoradiotherapy combined with extended-field conformal radiotherapy for patients with high-risk cervical cancer. Methods and Materials: Patients with previously untreated cervical cancer, with Stage III/IVA disease, or Stage IB/II with high-risk factor (primary tumor diameter {>=}50 mm or positive lymph node) were entered into this study. Three cycles of chemotherapy with 3,500 mg/m{sup 2} of 5-fluorouracil (5-FU) and nedaplatin (NDP) were accompanied with pelvic irradiation of 45.6-51.3 Gy in 24-27 fractions over 6 weeks. Prophylactic (36 Gy/20 fractions) or definitive (45-56 Gy) irradiation for para-aortic region was followed by pelvic irradiation. Results: Between 1998 and 2004, 40 patients were recruited for this protocol study. Eighteen patients from Phase I setting were registered. Twenty-two patients were treated with NDP of 140 mg/m{sup 2} (the recommended dose) in the Phase II segment. Twenty-five patients had T3 disease, and 25 patients had nodal disease including para-aortic involvement (n = 5). Overall/progression-free survival rates at 5 years were 78.8 and 66.5%, respectively. The median follow-up time was 61.8 months (25.5-106.7). Hematologic and gastrointestinal Grade 3 or more toxicities were relatively high rate (27.5-45%); however, they were well manageable. Two for bladder toxicity of Grade 3 were noted. Comparing the data from historical control group evaluated by magnetic resonance imaging, alternating chemoradiotherapy revealed a significant favorable factor for survival and disease recurrence in multivariate analysis (p < 0.05). Conclusion: Acquired results from our unique protocol for cervical cancer with high-risk factor were thought to be promising, considering that the majority of our cohort consisted of high-risk population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The lifetime risk and impact of vitiligo across sociodemographic groups: a UK population-based cohort study

Abstract Background Vitiligo is an autoimmune skin disorder characterized by depigmented patches of skin, which can have significant psychological impacts. Objectives To estimate the lifetime incidence of vitiligo, overall, by ethnicity and across other sociodemographic subgroups, and to investigate the impacts of vitiligo on mental health, work and healthcare utilization. Methods Incident cases of vitiligo were identified in the Optimum Patient Care Database of primary care records in the UK between 1 January 2004 and 31 December 2020. The lifetime incidence of vitiligo was estimated at age 80 years using modified time-to-event models with age as the timescale, overall and stratified by ethnicity, sex and deprivation. Depression, anxiety, sleep disturbance, healthcare utilization and work-related outcomes were assessed in the 2 years after vitiligo diagnosis and compared with matched controls without vitiligo. The study protocol for this retrospective observational study was registered with ClinicalTrials.gov (NCT06097494). Results In total, 9460 adults and children were newly diagnosed with vitiligo during the study period. The overall cumulative lifetime incidence was 0.92% at 80 years of age [95% confidence interval (CI) 0.90–0.94]. Cumulative incidence was similar in female (0.94%, 95% CI 0.92–0.97) and male patients (0.89%, 95% CI 0.86–0.92). There were substantial differences in lifetime incidence across ethnic groups, listed by Office for National Statistics criteria [Asian 3.58% (95% CI 3.38–3.78); Black 2.18% (95% CI 1.85–2.50); Mixed/multiple 2.03% (95% CI 1.58–2.47); Other 1.05% (95% CI 0.94–1.17); and White 0.73% (95% CI 0.71–0.76)]. Compared with matched controls, people with vitiligo had an increased risk of depression [adjusted odds ratio (aOR) 1.08, 95% CI 1.01–1.15]; anxiety (aOR 1.19, 95% CI 1.09–1.30); depression or anxiety (aOR 1.10, 95% CI 1.03–1.17); and sleep disturbance [adjusted hazard ratio (aHR) 1.15, 95% CI 1.02–1.31]. People with vitiligo also had a greater number of primary care encounters (adjusted incidence rate ratio 1.29, 95% CI 1.26–1.32) and a greater risk of time off work (aHR 1.15, 95% CI 1.06–1.24). There was little evidence of disparities in vitiligo-related impacts across ethnic subgroups. Conclusions Clinicians should be aware of the markedly increased incidence of vitiligo in people belonging to Asian, Black, Mixed/multiple and Other groups. The negative impact of vitiligo on mental health, work and healthcare utilization highlights the importance of monitoring people with vitiligo to identify those who need additional support.

Eleftheriadou, Viktoria↗

SNF Data Visualization on the Centralized Used Fuel Resource for Information Exchange (CURIE) Website

To better inform stakeholders regarding the nature of spent nuclear fuel (SNF) at utility sites, an online data visualization system has been created for the U.S. Department of Energy's Office of Nuclear Energy (DOENE). The data visualization system is part of the Centralized Used Fuel Resource for Information Exchange (CURIE) website, hosted by the Oak Ridge National Laboratory (ORNL) for DOE-NE. The visualization employs a database that is part of an analysis tool known as the Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST[and]DARDS). Because many of the previous document management and sharing tools related to SNF have been terminated (or are inaccessible), a new tool, the CURIE, was developed for DOE-NE and launched on March 1, 2013 at http://curie.ornl.gov. In addition to supporting DOE SNF programs, CURIE is a national resource that is accessible to industry, vendor, federal, and laboratory partners, as well as other stakeholders. CURIE's architecture was initially based on previous work that supported DOE's Bioenergy Technologies Office on the Bioenergy Knowledge Discovery Framework (KDF). The site uses an open-source search engine, Apache Solr, which provides intuitive search results based on a faceted search method similar to that used by Amazon.com{sup R}. This algorithm helps to ensure that finding documents and data is straightforward. SNF data visualization capability was added to the CURIE website which provides a capability to post and access documents and data related to the management of SNF. CURIE currently maintains over 4,100 documents and the Siting Experience Database (SED), which was developed in response to a near-term recommendation by the Blue Ribbon Commission on America's Nuclear Future (BRC). The SED is a database of the experience that has been gained and relevant documentation that has been produced in efforts to site nuclear waste facilities, both in the US and abroad. Most of these documents are publicly accessible. In addition, CURIE maintains a current calendar of related events, an SNF image gallery, featured documents, and external links to related databases and websites. CURIE also maintains private groups (or communities) to facilitate collaborative development through sharing and editing documents that are not publicly available. There are more than 250 registered users in 23 different communities within CURIE.ORNL has also been developing UNF-ST[and]DARDS to provide a controlled source of technical data for various waste management system analysis/evaluation tools, access to key technical data, and analysis capabilities for characterizing the SNF inventory. UNF-ST[and]DARDS also provides enhanced capabilities to assess safety, risk, and uncertainty throughout the integrated waste management system. This paper describes the UNF-ST[and]DARDS data available for visualization and the associated visualization techniques used by CURIE to display this data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC{sup Registered-Sign }, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic{sup TM} EBT and EBT2) in PMMA and in a Solid Water{sup Registered-Sign} phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon{sup Registered-Sign} and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any 'squircle-shaped' field. When one side of the rectangular field is held constant and the second side is reduced, both R{sub 50} and R{sub max} move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 Multiplication-Sign 4.4 cm{sup 2} square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 Multiplication-Sign 9 cm{sup 2} 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%). Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Second Quarter Hanford Seismic Report for Fiscal Year 2009

The Hanford Seismic Assessment Program (HSAP) provides an uninterrupted collection of high-quality raw and processed seismic data from the Hanford Seismic Network for the U.S. Department of Energy and its contractors. The HSAP is responsible for locating and identifying sources of seismic activity and monitoring changes in the historical pattern of seismic activity at the Hanford Site. The data are compiled, archived, and published for use by the Hanford Site for waste management, natural phenomena hazards assessments, and engineering design and construction. In addition, the HSAP works with the Hanford Site Emergency Services Organization to provide assistance in the event of a significant earthquake on the Hanford Site. The Hanford Seismic Network and the Eastern Washington Regional Network consist of 44 individual sensor sites and 15 radio relay sites maintained by the Hanford Seismic Assessment Team. The Hanford Seismic Network recorded over 800 local earthquakes during the second quarter of FY 2009. Nearly all of these earthquakes were detected in the vicinity of Wooded Island, located about eight miles north of Richland just west of the Columbia River. Most of the events were considered minor (magnitude (Mc) less than 1.0) with 19 events in the 2.0-2.9 range. The estimated depths of the Wooded Island events are shallow (averaging less than 1.0 km deep) with a maximum depth estimated at 1.9 km. This places the Wooded Island events within the Columbia River Basalt Group (CRBG). The low magnitude and the shallowness of the Wooded Island events have made them undetectable to most area residents. However, some Hanford employees working within a few miles of the area of highest activity, and individuals living in homes directly across the Columbia River from the swarm center, have reported feeling some movement. The Hanford SMA network was triggered numerous times by the Wooded Island swarm events. The maximum acceleration values recorded by the SMA network were approximately 2-3 times lower than the reportable action level for Hanford facilities (2% g) and no action was required. The swarming is likely due to pressures that have built up, cracking the brittle basalt layers within the Columbia River Basalt Formation (CRBG). Similar earthquake “swarms” have been recorded near this same location in 1970, 1975 and 1988. Prior to the 1970s, swarming may have occurred, but equipment was not in place to record those events. Quakes of this limited magnitude do not pose a risk to Hanford cleanup efforts or waste storage facilities. Since swarms of the past did not intensify in magnitude, seismologists do not expect that these events will increase in intensity. However, PNNL will continue to monitor the activity continuously. Outside of the Wooded Island swarm, four earthquakes were recorded. Three earthquakes were classified as minor and one event registered 2.3 Mc. One earthquake was located at intermediate depth (between 4 and 9 km, most likely in the pre-basalt sediments) and three earthquakes at depths greater than 9 km, within the basement. Geographically, two earthquakes were located in known swarm areas and two earthquakes were classified as random events.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗